Key Features At A Glance

  • Available as 2-channel (HD302MSO) or 4-channel (HD304MSO) models, each with 16 digital channels (MSO) standard
  • Bandwidth from 200 MHz to 1 GHz across the series via immediate license upgrades — no return to factory
  • 14-bit ADC, increasing to 16 bits of vertical resolution using the built-in bandwidth-limit filters
  • Up to 100 Mpts capture memory per channel with dedicated per-channel memory and no interleaving
  • 3.2 GSa/s sample rate per channel and an uncompromised update rate over 1,300,000 waveforms/sec
  • 10.1-inch capacitive, gesture-enabled touch display (1280 x 800)
  • LAN (10/100/1000Base-T), USB 3.0 host, and USB 2.0 device (USBTMC) interfaces standard
  • Standard functions include zone trigger, segmented memory, mask testing, FFT, histograms, and Fault Hunter
View full details

The Keysight InfiniiVision HD3 Series is a portable oscilloscope line that brings high-performance measurement capability into a high-volume, bench-portable form factor across a 200 MHz to 1 GHz bandwidth span. It leverages custom hardware technology drawn from the UXR Series, including a custom 14-bit ADC and a low-noise front end, delivering four times the vertical accuracy and half the noise floor of the prior generation, paired with twenty-five times more memory. The result is an instrument built to capture small signals with high vertical resolution and present a realistic view of the signals inside a device.

With its 14-bit architecture and built-in bandwidth filters, the HD3 is designed to analyze every signal in a design with high vertical accuracy, resolving small signals — such as a 2 µV, –100 dBm tone in an FFT — that would be lost in a higher-noise-floor instrument. The series supports mixed-signal work through 16 integrated digital channels, and the Fault Hunter application automatically evaluates a signal's characteristics against user-definable criteria to find and log errors over test windows ranging from a few minutes up to two days. Optional licensed software extends the platform to embedded serial decode and triggering (I2C, SPI, and UART/RS-232/422/485) and to automotive buses (CAN, CAN FD, CAN XL, and LIN).

ValueTronics has supplied new and used test and measurement equipment since 1992, holding its own stock in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Because we carry our inventory in-house, every order ships from equipment we hold and control.

Brand Heritage

Keysight Technologies traces its test and measurement heritage to Hewlett-Packard, whose instrument business was spun off as Agilent Technologies in 1999 and then established as Keysight Technologies in 2014. Instruments carrying the Keysight name continue a measurement lineage that spans the Hewlett-Packard and Agilent eras.

Compare Other Models in This Series

The InfiniiVision HD3 Series comprises two models that share a common architecture and differ in analog channel count: the HD302MSO with two analog channels and the HD304MSO with four. Both models include 16 digital channels with the MSO interface enabled as standard, and both come standard with a minimum 200 MHz bandwidth.

Across the series, the custom 14-bit ADC, low-noise front end, 3.2 GSa/s sample rate, up to 100 Mpts of per-channel memory, and the MegaZoom 5 ASIC are shared. The models are configured by selecting analog channel count first, then layering bandwidth, memory, and software licenses to match the application.

Each new model in the HD3 Series is listed on its own dedicated product page with condition-matched pricing. Select the model and configuration that fits your requirement, and review the comparison table below to confirm the analog channel count and configuration before ordering.

The primary difference between the two models is analog channel count: the HD302MSO provides two analog channels and the HD304MSO provides four, while both carry the same 16 digital channels. The comparison table below details the per-model specifications.

Bandwidth is selectable across the series at 200 MHz, 350 MHz, 500 MHz, and 1 GHz, with corresponding calculated rise times, and is set by license rather than by hardware exchange. Capture memory is likewise configurable from a standard 20 Mpts to 50 Mpts or 100 Mpts per channel, so two units of the same model number can differ in bandwidth and memory according to the licenses applied.

Model Standard Bandwidth (upgradeable to 1 GHz) Analog Channels Digital Channels
HD302MSO 200 MHz 2 16
HD304MSO 200 MHz 4 16

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • N2843A Passive probe 500 MHz 10:1 attenuation (1 per channel)
  • Soft copy of Certificate of Calibration (CoC), 3-year calibration interval

Product Core & Specifications

Specification Value
Specification Overview
Bandwidth (-3 dB) 200 MHz / 350 MHz / 500 MHz / 1 GHz (200 MHz standard, license-upgradeable)
Calculated rise time (10 to 90%) ≤ 2.0 ns (200 MHz) / ≤ 1.3 ns (350 MHz) / ≤ 900 ps (500 MHz) / ≤ 450 ps (1 GHz)
Maximum sample rate 3.2 GSa/s per channel
Maximum memory depth 100 Mpts per channel
Display size and type 10.1-inch capacitive touch gesture-enabled display
Waveform update rate Uncompromised > 1,300,000 waveforms per second
Input channels (analog / digital) HD302MSO: 2 analog, 16 digital; HD304MSO: 4 analog, 16 digital
Vertical System — Analog Channels
Hardware bandwidth limits 5, 10, 20, 50, 100, 200, 350 MHz (selectable) Global; 40 MHz Each Channel
Input coupling AC, DC
Input impedance 50 Ω ± 1.5%; 1 MΩ ± 1% ‖ ~24 pF
Input sensitivity range 50 Ω: 500 µV/div to 1 V/div; 1 MΩ: 500 µV/div to 10 V/div
Vertical resolution 14 bits (16 bits using bandwidth limits)
Maximum input voltage 135 Vrms; 190 Vpk
DC vertical gain accuracy ±1.5% full scale
DC voltage measurement accuracy Dual cursor: ± [(DC gain accuracy) + 0.16% full scale]; Single cursor: ± [(DC gain accuracy) + (offset accuracy) + 0.08% full scale]
DC vertical offset accuracy ± 0.1 div ± 1 mV ± 1.5% of offset setting
Channel-to-channel isolation > 100:1 from DC to maximum specified bandwidth of each model (same V/div and coupling)
Offset range 50 Ω: 500 µV/div to 100 mV/div: ±1.5 V; >100 mV/div to 1 V/div: ±5 V. 1 MΩ: 500 µV/div to 100 mV/div: ±1.5 V; >100 mV/div to 1 V/div: ±15 V; >1 V/div to 10 V/div: ±150 V
Noise density (101 MHz, 1 MHz span, 15 kHz RBW) -38 dBm: -161.2 dBm/Hz; 0 dBm: -141.5 dBm/Hz; 6 dBm: -133.1 dBm/Hz
Signal-to-noise dynamic range 96 dB (0 dBm 100 MHz carrier, 0 dBm input range (80 mV/div), 100 MHz CF, 50 MHz span, 15 kHz RBW, at +15 MHz from CF)
Spurious free dynamic range (SFDR) 79 dB (0 dBm 100 MHz carrier, 0 dBm input range (80 mV/div), 500 MHz span, 300 MHz CF, 150 kHz RBW)
Amplitude accuracy 0.3 dB (0 to 1 GHz)
Deviation from linear phase 10° (0 to 1 GHz)
Vertical System — Digital Channels
Digital input channels 16 digital (D0 to D15; pod 1: D3~D0, pod 2: D7~D4, pod 3: D11~D8, pod 4: D15~D12)
Threshold selections TTL (+1.4 V), 5 V CMOS (+2.5 V), ECL (–1.3 V), user-defined (selectable by pod)
User-defined threshold range ± 8.0 V in 10 mV steps
Maximum input voltage ± 40 V peak
Threshold accuracy ± (100 mV + 3% of threshold setting)
Maximum input dynamic range ± 10 V about threshold
Minimum voltage swing 500 mVpp
Input impedance 100 kΩ ± 2% at probe tip
Input capacitance ~8 pF
Vertical resolution 1 bit
RMS Noise Floor (VRMS AC) on 50 Ω inputs
500 µV/div, 2 mV/div (20/100/200/350/500 MHz/1 GHz) 13u / 20u / 26u / 30u / 35u / 48u
5 mV/div 16u / 25u / 33u / 38u / 44u / 59u
10 mV/div 24u / 35u / 49u / 56u / 67u / 87u
20 mV/div 44u / 63u / 89u / 104u / 124u / 159u
50 mV/div 92u / 141u / 202u / 239u / 286u / 366u
100 mV/div 189u / 278u / 399u / 474u / 568u / 723u
200 mV/div 442u / 638u / 898u / 1.06m / 1.26m / 1.60m
500 mV/div 942u / 1.41m / 2.03m / 2.41m / 2.88m / 3.66m
1 V/div 1.78m / 2.82m / 4.04m / 4.79m / 5.74m / 7.26m
RMS Noise Floor (VRMS AC) on 1 MΩ inputs
500 µV/div, 2 mV/div (20/100/200/350/500 MHz) 21u / 34u / 50u / 76u / 96u
5 mV/div 24u / 37u / 53u / 80u / 100u
10 mV/div 31u / 46u / 64u / 92u / 112u
20 mV/div 51u / 72u / 97u / 132u / 154u
50 mV/div 150u / 146u / 198u / 263u / 295u
100 mV/div 204u / 280u / 330u / 505u / 560u
200 mV/div 454u / 686u / 947u / 1.29m / 1.51m
500 mV/div 926u / 1.42m / 1.95m / 2.60m / 2.92m
1 V/div 1.96m / 2.77m / 3.78m / 5.01m / 5.58m
2 V/div 4.42m / 6.76m / 9.42m / 13.0m / 15.1m
5 V/div 9.63m / 14.2m / 19.5m / 26.1m / 29.2m
10 V/div 20.2m / 27.9m / 38.0m / 50.3m / 55.9m
ENOB (Normal Sample Mode, 100 mV/div, 1 MΩ, 10 MHz 90% full-screen sine)
50 Ω (20/50/100/200/350/500 MHz/1 GHz) 10.4 / 9.9 / 9.5 / 9.0 / 8.8 / 8.5 / 8.2
1 MΩ (20/50/100/200/350/500 MHz/1 GHz) 10.3 / 9.9 / 9.5 / 8.9 / 8.8 / 8.4 / N/A
Horizontal System — Analog Channels
Time base range 500 ps/div to 50 s/div
Time base accuracy ± 1.6 ppm + aging factor (1 year: ± 0.5 ppm, 2 years: ± 0.7 ppm, 5 years: ± 1.5 ppm, 10 years: ± 2.0 ppm)
Time base delay range Pre-trigger: Maximum of 20M/sample rate, no more than 200 s; Post-trigger: Up to 500 sec
Channel-to-channel deskew range ± 100 ns
Δ Time accuracy (using cursors) Same channel: ± (time base accuracy × reading) ± (0.0016 × screen width) ± 50 ps; Channel-to-channel: ± (time base accuracy × reading) ± (0.0016 × screen width) ± 100 ps
Modes Main, zoom
Horizontal System — Digital Channels
Minimum detectable pulse width 5 ns
Channel-to-channel skew 2 ns (typical); 3 ns (maximum)
Acquisition System
Maximum analog channels sample rate 3.2 GSa/s all channel
Maximum analog channels record length (every channel) 20 Mpt standard; 50 Mpt with 50 Mpt license; 100 Mpt with 100 Mpt license
Important: Maximum input voltage: 135 Vrms; 190 Vpk. Use this instrument only for measurements within its specified measurement category (not rated for CAT II, III, IV); no transient overvoltage allowed.
Important: Probing technology allows testing of higher voltages; for example, the included N2843A 10:1 probe supports testing up to 300 Vrms.
Important: The 16 digital channel MSO cable (HD3MSO) is listed as an optional accessory and is not part of the standard delivery (the base unit ships with N2843A passive probes only); it must be ordered separately to connect the instrument's 16 digital MSO channels.
Important: Standard memory depth is 20 Mpts/channel; 50 Mpts and 100 Mpts depths are available as license-only upgrades. Check your instrument's configuration for the installed depth on this unit.
Usage tip: the HD3 includes the N2843A 500 MHz 10:1 passive probe (one per channel); add the HD3MSO 16-channel digital cable to enable mixed-signal probing on the 16 digital channels.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Factory New

Manufacturer

Keysight

Osc_ch

2

Osc_freq

200 MHz

Osc_r

50 Ω / 1 MΩ

Osc_sampl

3.2 GSa/s per channel

1 GHz

1 GHz bandwidth and standard memory

350 MHz

350 MHz bandwidth and standard memory

500 MHz

500 MHz bandwidth and standard memory

HD3MSO

MSO Logic Cable Probe , 16-Channel