Keysight EXR108A 1 GHz 8-Channel Oscilloscope

Keysight EXR108A 1 GHz 8-Channel Oscilloscope

Regular price $56,431
Sale price $56,431 Regular price $0
Shipping calculated at checkout.
Request a Quote

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Keysight EXR108A 1 GHz 8-Channel Oscilloscope

Key Features At A Glance

  • Eight models from 500 MHz to 2.5 GHz in 4- or 8-channel configurations, all fully upgradeable via license key
  • 16 GSa/s sample rate on every analog channel with a 10-bit ADC, up to 16 bits in high-resolution mode
  • 100 Mpts standard memory per channel, upgradeable to 400 Mpts or 1.6 Gpts combined flexible memory
  • >200,000 waveforms/sec update rate driven by a 100M+ gate CMOS ASIC
  • 4-digit DVM and 10-digit counter standard; logic analysis, 50 MHz AWG, and FRA optional
  • 15.6-inch full-HD capacitive touchscreen with independent second-monitor support
  • LAN (10/100/1000Base-T), USB 3.0, and LXI Class C for remote control and test automation
  • Standard Fault Hunter, history mode, and segmented memory for capturing intermittent events
View full details

The Keysight Infiniium EXR-Series is a family of real-time oscilloscopes offered in eight models that range in performance from 500 MHz to 2.5 GHz, with four or eight analog channels and dozens of hardware and software options. Positioned as powerful, easy to own, and intuitive to use, the series pairs a 10-bit front end with a 15.6-inch full-HD touch display and a deep set of integrated measurement tools.

The EXR-Series documents a broad set of measurement applications. The Power Measurements package supports automated switched-mode power supply characterization — including input, switching-device, and output analysis plus frequency response analysis for control loop response and PSRR — while the Power Rail and PMIC integrity package targets power-supply-induced jitter and DC-rail noise. Protocol trigger and decode packages debug and test serial digital designs, and physical-layer tools address signal integrity on high-speed interfaces where eye diagrams close due to ISI, noise, and loss.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.

Brand Heritage

The test and measurement business behind this instrument traces a well-known corporate lineage: Hewlett-Packard spun out its test and measurement operations as Agilent Technologies in 1999, and that business became Keysight Technologies in 2014.

Compare Other Models in This Series

The Infiniium EXR-Series is a single oscilloscope family spanning eight models, organized by bandwidth tier — 500 MHz, 1 GHz, 2 GHz, and 2.5 GHz — and by channel count, with both four- and eight-channel versions of each tier. Across the family the architecture is shared: 16 GSa/s sampling on every channel, a 10-bit ADC, 100 Mpts of standard memory, and a 15.6-inch full-HD touch display.

Because the series is fully upgradeable by license key, a four-channel, lower-bandwidth model can later gain bandwidth, additional channels, memory, integrated instruments, and analysis software without hardware replacement. This lets a lab buy for today's project and expand the same frame as requirements grow.

Each new model in the EXR-Series family below is its own dedicated product page with condition-matched pricing. Select the specific bandwidth and channel configuration you need to view its individual specifications and availability.

The models differ along two axes the comparison table makes explicit: bandwidth and channel count. Bandwidth runs from 500 MHz on the EXR05xA models to 2.5 GHz on the EXR25xA models, with corresponding typical rise/fall times that shorten as bandwidth increases, while channel count is set by the model suffix — a '4' for four channels and an '8' for eight.

Model numbers encode the configuration directly: EXR054A and EXR058A are 500 MHz, EXR104A/EXR108A are 1 GHz, EXR204A/EXR208A are 2 GHz, and EXR254A/EXR258A are 2.5 GHz. Sample rate (16 GSa/s), standard memory, resolution, and the integrated instrument set are common across the family; see the comparison table for the per-model bandwidth, channel, and rise-time figures.

Model Bandwidth Analog Channels Sample Rate
EXR108A 1 GHz 8 16 GSa/s
EXR054A 500 MHz 4 16 GSa/s
EXR058A 500 MHz 8 16 GSa/s
EXR104A 1 GHz 4 16 GSa/s

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Passive Probe, 10:1, 500 MHz (N2873A) — Qty 8
  • 50 Ω Calibration Cable, 1 meter (54609-61609)
  • Accessory Pouch (54925-62301)
  • Protective Front Cover (54925-44101)
  • Local Power Cord
  • Full-Size Keyboard (0960-3245)
  • Optical Scroll Wheel Mouse (0960-3246)
  • 1 Year Factory Calibration Certificate
  • Safety Leaflets, if Applicable
  • Probe Selection Guide

Product Core & Specifications

Specification Value
Model-Specific Performance
Bandwidth (-3 dB), 50 Ω 1 GHz
Bandwidth (-3 dB), 1 MΩ 500 MHz
Typical rise/fall time (10/90%) 430 ps
Typical rise/fall time (20/80%) 310 ps
Input channels 8 channels analog, 16 channels digital (optional)
Intra-channel Intrinsic Jitter (8 channel model)
100 ns/div 150 fsRMS
1 µs/div 156 fsRMS
10 µs/div 172 fsRMS
100 µs/div 175 fsRMS
1 ms/div 181 fsRMS
Trigger jitter 531 fsRMS
Power, Acoustic, Weight
Max power dissipated 650 Watts
Acoustic noise, operator position 49.9 dB
Acoustic noise, bystander position 42.9 dB
Weight, frame 14.50 kg (32.0 lbs.)
Weight, shipping 21.90 kg (48.3 lbs.)
Important: Maximum input voltage is ±5 VMAX on the 50 Ω path and 30 VRMS or ±40 VMAX (DC + peak) on the 1 MΩ path; the included N2873A 10:1 probe supports 300 VRMS or ±400 VMAX (DC + peak). No transient overvoltage is allowed in either path, with or without probes.
Important: Combining two EXR-Series oscilloscopes for 16-channel Multiscope operation requires software revision 11.10 or greater and a separately ordered cabling kit.
Important: All EXR-Series models are calibrated to 2.5 GHz at the factory, so bandwidth upgrades require no further calibration outside the standard recommended interval.
Important: Channel upgrades from 4 to 8 channels (EXR28CH series) require return to a Keysight service center; the model and serial number are kept and the cost of upgrade does not include shipping.
Recommended pairing: the Keysight N7020A or N7024A Power Rail Probe works with the D9010POWA power and PMIC integrity package for measuring and analyzing power-rail noise and power-supply-induced jitter.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Factory New

Manufacturer

Keysight

Osc_ch

8

Osc_freq

1 GHz

Osc_r

50 Ω / 1 MΩ

Osc_sampl

16 GSa/s

EXR2MSO 16-Channel Logic Analysis (MSO) Option for Infiniium EXR-Series (includes N2756A probe)

EXR2MSO

EXR2RACK 8U Rackmount Kit for Infiniium EXR-Series

EXR2RACK