Key Features At A Glance

  • High-band frequency range of 10 MHz to 160 MHz with 1 Hz minimum step resolution
  • Low-band frequency range of 1 MHz to 12 MHz with 0.1 Hz minimum step resolution
  • Adjustable main output from +3 dBm to +13 dBm into 50 ohms, maintained ±1 dB
  • Non-harmonic spurious performance to -100 dBc in the 1 to 20 MHz range
  • Frequency division architecture: highest internally-generated frequency is the output VCO (80 to 160 MHz), simplifying servicing and reducing UHF EMC issues
  • Built-in remote programming via DTL/TTL, BCD, positive true logic or contact closures using 34 parallel lines
  • GPIB/IEEE-488 compatibility available via the Fluke 1120A Translator with the 6XXXA-529 Interface
  • Switching speed of less than 800 microseconds to be within 50 Hz of final frequency (80 MHz to 160 MHz range)
Share on
View full details

The Fluke 6160B Frequency Synthesizer is a VHF signal generator producing frequencies from 1 MHz to 160 MHz across two ranges: 1 MHz to 12 MHz with 0.1 Hz resolution, and 10 MHz to 160 MHz with 1 Hz resolution. The instrument is recognized in the industry for its high spectral purity in the VHF range.

A defining architectural characteristic of the 6160B is that the highest internally-generated frequency is that of the output VCO operating from 80 to 160 MHz. For coverage of lower frequencies, the instrument employs frequency division by contact closures rather than upconversion. This approach simplifies servicing, eliminates UHF EMC problems, and produces improved spurious specifications and reduced phase noise for frequencies below 80 MHz.

ValueTronics International has supported the test and measurement community since 1992, with all inventory stored, inspected, and performance-tested at our 20,000 square foot secure facility at 1675 Cambridge Drive in Elgin, Illinois. Legacy synthesizers such as the 6160B remain in active service in many established RF labs and production test environments, and our in-house technical resources allow us to verify these instruments against their original published specifications before shipment.

Brand Heritage

Fluke's test and measurement product portfolio has evolved through several corporate transitions over the decades. Fluke Corporation became part of the Danaher Corporation group, and certain product families have moved between brand identities over time. Instruments from the 6160B era reflect Fluke's established heritage in precision signal generation and frequency synthesis.

Accessories Supplied

  • Manual
  • Power cord
  • Mating connector for programming input lines
  • Serialized and dated calibration certificate

Product Core & Specifications

Parameter Specification
FREQUENCY
High Band Range 10 MHz to 160 MHz
High Band Minimum Step 1 Hz
Low Band Range 1 MHz to 12 MHz
Low Band Minimum Step 0.1 Hz
Local Control Front panel rotary switches
Remote Control BCD per decade, TTL, DTL positive true logic or contact closures. Logic "0" = 0 to 0.9V dc. Logic "1" = 2V to +5V dc or open circuit.
Spectral Purity Non-Harmonic, Spurious 1 to 20 MHz: -100 dBc; 20 to 40 MHz: -95 dBc; 40 to 80 MHz: -89 dBc; 80 to 160 MHz: -83 dBc
Harmonic, Spurious <-25 dBc, typically <-30 dBc
Amplitude Noise** <-94 dBc (typical)
Absolute Phase Noise** <-62 dBc (typical)
Residual Phase Noise** <-74 dBc (typical)
Phase Noise* Spectral Density 1 Hz Bandwidth Offset from Carrier 1.2 kHz: SSB Noise <-115 dBc; 32 kHz: <-121 dBc; 600 kHz: <-135 dBc
OUTPUTS
Main Output Adjustable from +3 dBm to +13 dBm into 50 Ω (0.3V to 001V rms) with front-panel control or external dc voltage. Level maintained ±1 dB into 50 Ω.
Other Outputs 5 MHz at nominally 1V rms into 50 Ω
Output Options Rear Panel, Opt -04
MISCELLANEOUS
Reference Frequency External, 5 MHz at 0 dBm to +16 dBm into 50 Ω
Level Control External, 0.1 to 0.8V dc nominal into >2 kΩ produces an output level change of from +3 dBm to +13 dBm
Switching Speed <800 µs to be within 50 Hz of final frequency (applies for frequencies from 80 MHz to 160 MHz. Improves at lower frequencies)
Internal 5 MHz Frequency Aging Rate (Option -02) ±2 x 10⁻⁹/day
Internal 5 MHz Frequency Aging Rate (Option -05) ±5 x 10⁻⁶/yr
Temp. Stability 1 x 10⁻⁸, 0°C to 50°C; 1 x 10⁻⁶, 0°C to 50°C
GENERAL
Altitude To 3048 meters (10,000 feet), operating; 15,240 meters (50,000 feet), non-operating
Temperature 0°C to 50°C, operating; -62°C to +70°C, non-operating
Relative Humidity ≤80% to 50°C
Power 115V or 230V ac ±10%, switch-selectable, 50 to 440 Hz, 80W
Size 48.3 cm W x 17.8 cm H x 50.8 cm L (19 in W x 7 in H x 20 in L)
Weight 20.5 kg (45 lb)

*Noise specifications are for frequencies from 80 MHz to 160 MHz. Noise performance improves for lower frequencies.
**Measured in a 30 kHz band excluding the 1 Hz band centered on the signal frequency.

Important: Requires an internal frequency standard (Option -02 or -05) or an external 5 MHz time base for operation. Options -02 and -05 are installable at the factory.Important: Option -02, -05 or an external 5 MHz time base is required. Option -02 and -05 Frequency Standards are installable at Factory.Important: Option -529 IEEE-488 Interface requires 1120A IEEE-488 Translator. Includes 6XXXA-522K and Y7205 Cable.Important: GPIB/IEEE-488 compatibility is achieved using the Fluke 1120A Translator and 6XXXA-529 Interface.Recommended pairing: use the Fluke 1120A IEEE-488 Translator together with the 6XXXA-529 Interface to enable GPIB/IEEE-488 automated control of the 6160B per the datasheet's stated compatibility path.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Fluke

Condition

Used

Manufacturer

Fluke

Frequency

160 MHz