The Fluke 752A Reference Divider is a precision ratio standard offering two divider outputs — 10:1 and 100:1 — with output uncertainties of 0.2 ppm and 0.5 ppm respectively. It sets a reference standard for ratio accuracy and ease of use in the calibration laboratory, providing a stable, self-calibrating means of dividing a known voltage with traceable confidence.
The 752A is used as a stand-alone divider, where an input applied to the INPUT terminals is switched by the MODE switch to either the 10:1 or 100:1 position with output available at the OUTPUT terminals. When augmented with a 10 V reference source such as the Fluke 732B and a null detector, the resulting system becomes a 5-decade cardinal point voltage calibrator with facilities for comparing input voltages of 1000 V, 100 V, 10 V, 1 V, and 0.1 V to the 10 V reference. The MODE switch reconfigures the system for each of these ranges with no manual lead changes necessary.
Fluke Calibration is the precision metrology division of Fluke Corporation, which has operated as part of Fortive Corporation since Fortive's 2016 spin-off from Danaher Corporation. The 752A Reference Divider is documented and supported under the Fluke Calibration brand.
| Specification | Value |
|---|---|
| Ratio Uncertainty (18 °C to 28 °C, within ±1 °C of calibration temperature, up to 8 hours after calibration) | |
| 10:1 ratio, 100 V input | 0.2 ppm; Null uncertainty ± 0.5 µV |
| 100:1 ratio, 1000 V input | 0.5 ppm; Null uncertainty ± 1.0 µV |
| Temperature Coefficient of Ratio | |
| Operating range | < ± 1 ppm/°C |
| Typical 15 °C to 30 °C | 0.1 ppm/°C |
| Input Resistance | |
| 10:1 ratio | 380 kΩ ± 1 % |
| 100:1 ratio — Divider | 4 MΩ |
| 100:1 ratio — Driver Guard | 4 MΩ |
| 100:1 ratio — Total | 2 MΩ ± 1 % |
| Maximum Input Voltage | |
| 10:1 ratio | 200 V (safety only; maximum voltage for best accuracy is 100 V) |
| 100:1 range | 1100 V |
| Power Coefficient Effect on Ratio | |
| 10:1 ratio | < 0.05 ppm of output with 100 V applied |
| 100:1 ratio | < 0.3 ppm of output with 1000 V applied |
| Weight | |
| Net | 8.4 kg (18.5 lb) |
| Shipping | 13.6 kg (30 lb) |
| Size | |
| Dimensions | 60.3 cm L x 22.1 cm W x 19.1 cm H (23.75 in L x 8.69 in W x 7.53 in H) |
| Compliance with Standards | |
| Standards | ANSI C39.5, 1980. IEC 348, 2nd edition, 1978 |
| Temperature and Humidity | |
| Non-operating temperature | -40 °C to +75 °C (humidity not controlled); 0 °C to 50 °C (95 ± 5 % RH max, non-condensing) |
| Operating temperature | 0 °C to 40 °C (75 ± 5 % RH max); 40 °C to 50 °C (45 ± 5 % RH max), non-condensing |
| Altitude | |
| Non-operating | 0 to 12,000 m (40,000 ft) |
| Operating | 0 to 3,050 m (10,000 ft) |
| Vibration | |
| Standard | Per MIL-T-288800C, Type III, Class 5, Style E |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.