Skip to product information
1 of 1
Used

Fluke 5520A High Performance Multi-Product Calibrator (Pre-Owned)

Fluke 5520A High Performance Multi-Product Calibrator (Pre-Owned)

Calibrations
Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Fluke 5520A High Performance Multi-Product Calibrator (Pre-Owned)

Key Features At A Glance

  • Multi-function calibration covering DC/AC voltage, DC/AC current, resistance, capacitance, frequency, temperature (thermocouple and RTD), and DC/AC power from a single instrument
  • DC voltage output from 0 to 1000V with two channels available in dual output mode (auxiliary output 0 to 7V on 5520A, 0 to 3.29999V on 5500A)
  • DC current output to 20.5A on the 5520A and to 10.9999A on the 5500A, extendable to 11A via the optional 5725A Amplifier (5500A)
  • Resistance output continuously variable from 0 to 1.1 GΩ (5520A) or 0 to 330 MΩ (5500A) with 2-wire, 4-wire, and compensated modes
  • Thermocouple simulation across types B, C, E, J, K, L, N, R, S, T, and U; RTD simulation including Pt 385, Pt 3926, Pt 3916, Ni120, and Cu 427 with ITS-90 or IPTS-68 selectable
  • Capacitance output continuously variable from 190 pF to 110 mF (5520A) or 330 pF to 1.1 mF (5500A), compatible with both DC charge/discharge and AC RCL meters
  • Standard IEEE-488 (GPIB) and RS-232 interfaces for automated calibration system integration
  • Specified absolute uncertainty includes stability, temperature coefficient, linearity, line and load regulation, and traceability of external standards used for calibration
Share on
View full details

The Fluke 5520A is a multi-product calibrator designed to calibrate a broad range of electronic test and measurement instruments from a single workstation. The 5520A consolidates DC and AC voltage, DC and AC current, resistance, capacitance, frequency, temperature (thermocouple and RTD), and DC and AC power sourcing into one instrument, with two-channel output capability for power and phase applications. The 5500A is the companion model in the family, with a similar functional footprint at reduced output ranges in several functions.

A calibrator of this class is the reference instrument behind a calibration laboratory. Where a digital multimeter, oscilloscope, clamp meter, or power analyzer measures an unknown signal, a multi-product calibrator sources a known, traceable signal that the meter under test is verified against. The 5520A's listed output functions correspond to the input ranges of the instruments most commonly handled in a general-purpose calibration lab — DMMs, clamp meters, electronic thermometers using thermocouples or RTDs, LCR meters, frequency counters, and power and energy meters. The instrument also supports automated calibration workflows through GPIB and RS-232 interfaces.

Calibration laboratories that adopt the 5520A or 5500A typically run them for a decade or more, which makes both the instrument itself and the support behind it a long-term decision. ValueTronics stores and tests every unit at our 20,000 sq ft facility at 1675 Cambridge Drive in Elgin, Illinois, where calibrators of this class are powered up, evaluated against the published Fluke specifications referenced in this datasheet, and prepared for shipment with documented condition and accessory inventory. We have been a working source for Fluke metrology equipment since 1992, and the value of buying from an in-house tested source — rather than from a drop-ship listing — is that the unit you receive has been through technician hands before it reaches yours.

Brand Heritage

Fluke Corporation has manufactured precision electrical test and calibration instruments since 1948 and remains the brand of record for handheld and bench calibration equipment across North American metrology labs. Fluke acquired Hart Scientific (temperature calibration) and other adjacent calibration businesses over the years, and the 5520A and 5500A sit within the company's long-running multi-product calibrator line alongside the later 5522A and 5502A successor models.

Compare Other Models in This Series

The 5520A and 5500A are two members of Fluke's multi-product calibrator family, sharing the same chassis, the same operator interface, the same IEEE-488 and RS-232 interfaces, and the same overall set of functions — DC and AC voltage, DC and AC current, resistance, capacitance, frequency, thermocouple and RTD temperature simulation, and DC and AC power. The datasheet presents them side-by-side because most calibration laboratories evaluating one model are also evaluating the other.

The 5520A is the higher-performance member of the pair, with tighter absolute uncertainty on most ranges, higher current output (20.5A vs. 10.9999A), broader resistance range (to 1.1 GΩ vs. 330 MΩ), broader capacitance range (to 110 mF vs. 1.1 mF), and a wider AC voltage frequency range in dual-output mode (30 kHz vs. 10 kHz). The 5500A targets a slightly different price/performance point and supports the external 5725A Amplifier for current and high-voltage extension.

Each pre-owned model in this family is listed as its own product page with condition-matched pricing. The links below take you to the specific model and condition pages where you can review current availability, accessories, and ordering details for the configuration you need.

The 5520A is described in the datasheet as the high-performance multi-product calibrator in the pair, with the wider current range (to 20.5A), the wider resistance range (to 1.1 GΩ), the wider capacitance range (to 110 mF), and the tighter absolute uncertainty specifications across most functions. Pressure module support via the FLUKE-700PCK kit is listed under the 5520A, not the 5500A.

The most visible differences between the 5520A and the 5500A are in the headline output ranges. DC current goes to 20.5A on the 5520A versus 10.9999A on the 5500A. Resistance extends to 1.1 GΩ on the 5520A versus 330 MΩ on the 5500A. Capacitance extends to 110 mF on the 5520A versus 1.1 mF on the 5500A.

The 5500A supports the 5725A Amplifier as an external accessory to extend high-current AC output to 11A and high-voltage AC output to 750V (with specifications listed separately in the AC voltage and AC current tables). The 5520A is listed with pressure module compatibility through the FLUKE-700PCK kit and the FLUKE-700P-series modules, which the 5500A is not. Refer to the comparison table that follows for the specific specifications cited in the datasheet for each model.

Model DC Voltage Range DC Current Range AC Voltage Bandwidth
5520A 0 to 1000 V 0 to 20.5 A 10 Hz to 500 kHz
5500A 0 to 1000 V 0 to 10.9999 A (to 11 A with 5725A Amplifier) 10 Hz to 500 kHz

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification 5520A
DC Voltage Range 0 to 1000 V (max 1020 V)
DC Voltage Best 1 Year Uncertainty 11 ppm + 2 µV (3.3 V range)
DC Current Range 0 to 20.5 A (full 20.5 A available continuously for 20 minutes at 20°C)
DC Current Best 1 Year Uncertainty 150 ppm + 0.02 µA (329.999 µA range)
Resistance Range 0 to 330 MΩ (continuously variable)
Resistance Best 1 Year Uncertainty 28 ppm + floor
AC Voltage Range 1.0 mV to 1000 V
AC Voltage Frequency Range 10 Hz to 500 kHz (extended bandwidth to 2 MHz typical)
AC Current Range 29 µA to 20.5 A
AC Current Frequency Range 10 Hz to 30 kHz
Capacitance Range 190 pF to 110 mF (continuously variable)
Frequency Range 0.01 Hz to 2.000 MHz
Frequency 1 Year Uncertainty 2.5 ppm, ±5 µHz
Frequency Jitter 100 nS
Phase 1 Year Uncertainty (10 to 65 Hz) 0.10°
Phase Resolution (Dual AC Outputs) 0.01 degrees
Max Frequency of Dual Output 30 kHz
Thermocouple Types B, C, E, J, K, L, N, R, S, T, U
RTD Types Pt 385 (100/200/500/1000 Ω), Pt 3926 100Ω, Pt 3916 100Ω, Ni120 120Ω, Cu 427 10Ω
Temperature Standard ITS-90 or IPTS-68 selectable
DC Power 1 Year Uncertainty (best) 0.023%
AC Power 1 Year Uncertainty (best, PF=1) 0.08%
Warmup Time Twice time since last warmed up, max 30 minutes
Settling Time Less than 5 seconds (all functions/ranges except as noted)
Standard Interfaces IEEE-488 (GPIB), RS-232
Operating Temperature 0°C to 50°C
Calibration Temperature (tcal) 15°C to 35°C
Storage Temperature -20°C to 70°C
Relative Humidity (Operating) <80% to 30°C, <70% to 40°C, <40% to 50°C
Altitude (Operating) 3,050 m (10,000 ft) maximum
Safety IEC 1010-1 (1992-1); ANSI/ISA-S82.01-1994; CAN/CSA-C22.2 No. 1010.1-92
Analog Low Isolation 20 V
EMC Designed to comply with IEC 61326-1/1997
Line Voltage (selectable) 100 V, 120 V, 220 V, 240 V
Line Frequency 47 to 63 Hz
Power Consumption 600 VA
Dimensions (H × W × D) 17.8 × 43.2 × 47.3 cm (7 × 17 × 18.6 in)
Weight (without options) 22 kg (49 lb)
Specification Confidence Interval >99%
Important: Maximum voltage output is 1020V. Analog Low isolation is 20V. At 20 °C, full 20.5A output on the 5520A (and full 11A output on the 5500A via the 5725A Amplifier) is available continuously for 20 minutes.Important: Maximum voltage output is 1020V.Important: At 20°C, full 20.5A output is available continuously for 20 minutes (5520A).Important: For optimal 5520A performance at full dual outputs (e.g. 1000V, 20A), choose a line voltage setting that is ±7.5% from nominal.Important: After long periods of storage at high humidity, a drying out period (with the power on) of at least one week may be required.Important: 5520A/5500A uncertainty specifications include stability, temperature coefficient, linearity, line and load regulation and the traceability of the external standards used for calibration. No additional adders are needed to determine the total uncertainty for the indicated temperature range.Important: Oscilloscope Calibration Options (5500A-SC300, 5500A-SC600, 5500A-SC1100) are ordered separately and are required for oscilloscope calibration capability.Important: Pressure modules (FLUKE-700P series) and the FLUKE-700PCK Pressure Module Calibration Kit are required for pressure calibration with the 5520A and are not included with the base calibrator.Important: The 5725A Amplifier (for 5500A only) is required to extend voltage and current ranges beyond the base 5500A specifications.Important: Test leads, current coil, transit case, side handle, rack mount kit, and calibration software are listed as separate accessories and must be ordered separately if required.Recommended pairing: the 5500A oscilloscope calibration options (5500A-SC300, 5500A-SC600, 5500A-SC1100) extend the calibrator into scope calibration at 300 MHz, 600 MHz, and 1.1 GHz respectively. For pressure work on the 5520A, the FLUKE-700PCK Pressure Module Calibration Kit is required to use any of the FLUKE-700P-series pressure modules.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Fluke

Condition

Used

Manufacturer

Fluke

PQ

Power Quality Option

SC600

600 MHz/300 ps Oscilloscope Calibration Option