Key Features At A Glance

  • 9 kHz to 43 GHz frequency range, tunable to 0 Hz; preamplifier coverage 100 kHz to 43 GHz
  • Dynamic range greater than 104 dB in 1 Hz RBW (TOI-DANL at 2.4 GHz)
  • DANL to -160 dBm in 1 Hz RBW with preamp on (10 MHz to 4 GHz)
  • SSB phase noise -100 dBc/Hz at 10 kHz offset (1 GHz carrier); RBW 1 Hz to 10 MHz
  • Internal preamplifier and AM/FM/SSB audio demodulation standard
  • LAN (10/100), dual USB, and 10 MHz external reference I/O; MST Remote Access Tool for remote control
  • Frequency accuracy of +-25 ppb with GPS On (GPS receiver optional)
  • Optional cellular and wireless signal analyzers including LTE, TD-LTE, GSM/EDGE, W-CDMA, CDMA, and WiMAX
View full details

The Spectrum Master MS2726C is a high performance handheld spectrum analyzer covering 9 kHz to 43 GHz (tunable to 0 Hz), built to deliver the performance needed for demanding measurements in harsh RF and physical environments. In a portable 315 mm x 211 mm x 77 mm chassis weighing 3.8 kg (8.5 lb), it brings spectrum and interference analysis to the field while retaining the measurement capability associated with bench-class instruments.

A spectrum analyzer displays the amplitude of signals across a span of frequencies, letting an engineer see where energy sits in the spectrum and how it behaves over time. The MS2726C is positioned for spectrum monitoring, broadcast proofing, interference analysis, RF and microwave measurements, regulatory compliance, and Wi-Fi and wireless network measurements, making it suited to wireless professionals who need fast and reliable results away from the bench.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, which lets us move quickly on quotes and shipments and stand behind what we sell. Every used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Accessories Supplied

  • Handheld Instruments Documentation Disc (10920-00060)
  • Spectrum Master User Guide, includes GPS Receiver (10580-00277)
  • Master Software Tools (MST) CD Disc (2300-498)
  • Soft Carrying Case (2000-1685-R)
  • Rechargeable Li-Ion Battery, for replacement use high-capacity battery 633-75 (633-44)
  • AC/DC Power Supply (40-187-R)
  • Automotive Cigarette Lighter 12 Volt DC Adapter (806-141-R)
  • Ethernet Cable, 7 feet/213 cm (2000-1371-R)
  • USB A-mini B Cable, 10 feet/305 cm (3-2000-1498)
  • MS2726C Spectrum Master Technical Data Sheet (11410-00527)
  • One Year Warranty (Including battery, firmware, and software)
  • Certificate of Calibration and Conformance

Product Core & Specifications

Specification Value
Frequency
Frequency Range 9 kHz to 43 GHz (tunable to 0 Hz), Preamp 100 kHz to 43 GHz
Tuning Resolution 1 Hz
Frequency Reference Aging ±1.0 ppm/10 years
Frequency Reference Accuracy ±0.3 ppm (25 °C ±25 °C) + aging
Auto-sensing External Frequency Reference 1, 1.2288, 1.544, 2.048, 2.4576, 4.8, 4.9152, 5, 9.8304, 10, 13, 19.6608 MHz
Frequency Span 10 Hz to 43 GHz including zero span
Sweep Time 10 µs to 600 seconds in zero span
Sweep Time Accuracy ±2 % in zero span
Bandwidth (Performance Sweep Mode)
Resolution Bandwidth (RBW) 1 Hz to 10 MHz in 1–3 sequence ±10 % (–3 dB bandwidth)
Video Bandwidth (VBW) 1 Hz to 10 MHz in 1–3 sequence (–3 dB bandwidth)
RBW with Quasi-Peak Detection 200 Hz, 9 kHz, 120 kHz (–6 dB bandwidth)
VBW with Quasi-Peak Detection Auto VBW is On, RBW/VBW = 1
Spectral Purity
SSB Phase Noise at 1 GHz @ 10 kHz offset –100 dBc/Hz (–104 dBc/Hz typical)
SSB Phase Noise at 1 GHz @ 100 kHz offset –102 dBc/Hz (–107 dBc/Hz typical)
SSB Phase Noise at 1 GHz @ 1 MHz offset –107 dBc/Hz (–114 dBc/Hz typical)
SSB Phase Noise at 1 GHz @ 10 MHz offset –120 dBc/Hz (–129 dBc/Hz typical)
Amplitude Ranges
Dynamic Range > 104 dB @ 2.4 GHz, 2/3 (TOI-DANL) in 1 Hz RBW
Measurement Range DANL to +30 dBm
Display Range 1 to 15 dB/div in 1 dB steps, ten divisions displayed
Reference Level Range –150 dBm to +30 dBm
Attenuator Resolution 0 to 65 dB, 5 dB steps
Amplitude Units Log Scale: dBm, dBV, dBmv, dBµV; Linear Scale: nV, µV, mV, V, kV, nW, µW, mW, W, kW
Maximum Continuous Input +30 dBm Peak, ±50 VDC (≥10 dB Attn); +23 dBm Peak, ±50 VDC (< 10 dB Attn); +13 dBm Peak, ±50 VDC (Preamp On)
Amplitude Accuracy (single sine wave input < Ref level, > DANL, auto attenuation, Performance Sweep Mode)
20 °C to 30 °C after 30 minute warm-up Typical: ±0.5 dB, 100 kHz to 40 GHz; Maximum: ±1.3 dB, 100 kHz to 13 GHz; Add ±1.0 dB, 13 GHz to 40 GHz
–10 °C to 50 °C after 60 minute warm-up Add ±1.0 dB, 100 kHz to 32 GHz; Add ±2.0 dB, 32 GHz to 40 GHz
Displayed Average Noise Level (DANL) in 1 Hz RBW, 0 dB attenuation
10 MHz to 4 GHz Preamp Off: –141 dBm; Preamp On: –160 dBm
> 4 GHz to 9 GHz Preamp Off: –134 dBm; Preamp On: –156 dBm
> 9 GHz to 13 GHz Preamp Off: –129 dBm; Preamp On: –152 dBm
> 13 GHz to 20 GHz Preamp Off: –123 dBm; Preamp On: –145 dBm
> 20 to 32 GHz Preamp Off: –134 dBm; Preamp On: –154 dBm
> 32 GHz to 40 GHz Preamp Off: –127 dBm; Preamp On: –147 dBm
Third-Order Intercept (TOI) (–20 dBm tones 100 kHz apart, –20 dBm Ref level, 0 dB input attenuation, Preamp Off)
2.4 GHz +15 dBm
50 MHz to 20 GHz +20 dBm typical
20 GHz to 32 GHz +15 dBm typical
32 GHz to 43 GHz +20 dBm typical
P1 dB
< 4 GHz +5 dBm typical
4 GHz to 20 GHz +12 dBm typical
20 GHz to 32 GHz +7 dBm typical
32 GHz to 43 GHz +12 dBm typical
Second Harmonic Distortion
50 MHz –54 dBc
< 4 GHz –60 dBc typical
> 4 GHz –75 dBc typical
Residual Spurs
Preamp Off (RF input terminated) –90 dBm 9 kHz to 13 GHz; –85 dBm 13 GHz to 20 GHz; –80 dBm 20 GHz to 43 GHz
Preamp On (RF input terminated) –100 dBm 1 MHz to 32 GHz; –95 dBm 32 GHz to 43 GHz
Input-Related Spurs (–30 dBm input, span < 1.7 GHz) –60 dBc, –70 dBc typical
VSWR (> 10 dB input attenuation)
< 20 GHz 1.5:1 typical
> 20 GHz to 43 GHz 2.0:1 typical
Memory
Internal Trace/Setup Memory > 13,000 traces
External Trace/Setup Memory Limited by size of USB Flash drive
Connectors
RF In Type K, male, 50 Ω, Maximum Input +30 dBm, ±50 VDC
GPS SMA Female
External Power 5.5 mm barrel connector, 12 to 15 VDC, < 5.0 Amps
LAN Connection RJ48C, 10/100 Mbps
USB Interface (2) Type A, Connect Flash Drive and Power Sensor
USB Interface 5-pin mini-B, Connect to PC for data transfer
Headset Jack 2.5 mm 3-wire headset jack
External Reference In BNC, female, 50 Ω, Maximum Input –10 dBm to +10 dBm
External Reference Out BNC, female, 50 Ω, 10 MHz
External Trigger BNC, female, 50 Ω, Maximum Input ±5 VDC
IF Out BNC, female, 50 Ω, 140 MHz
Display
Size 8.4 in
Resolution 800 x 600
Battery
Type Li-Ion
Battery Operation 2.5 hours, typical
Electromagnetic Compatibility
European Union CE Mark, EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC and Low Voltage Directive 73/23/EEC, 93/68/EEC
Australia and New Zealand C-tick N274
Interference EN 61326-1
Emissions EN 55011
Immunity EN 61000-4-2/-3/-4/-5/-6/-11
Safety
Safety Class EN 61010-1 Class 1
Product Safety IEC 60950-1 when used with Company supplied Power Supply
Environmental
Operating Temperature –10 °C to 55 °C
Maximum Humidity 85 %
Shock MIL-PRF-28800F Class 2
Storage –51 °C to 71 °C
Altitude 4600 meters, operating and non-operating
Size and Weight
Size 315 mm x 211 mm x 77 mm (12.4 in x 8.3 in x 3.0 in)
Weight 3.8 kg (8.5 lb)
Important: Maximum continuous input: +30 dBm peak, +-50 VDC (>=10 dB attenuation); +13 dBm peak with preamp on.
Important: High Accuracy Power Meter (Option 19) requires an external USB Power Sensor, which is not included with the base unit and must be ordered separately (e.g., PSN50, MA24105A, MA24106A, MA24108A, MA24118A, or MA24126A).
Important: GPS Receiver (Option 31) requires a GPS antenna ordered separately (P/N 2000-1528-R or 2000-1652-R); Anritsu GPS antennas 2000-1528-R and 2000-1652-R require 5 VDC.
Important: Secure Data Operation (Option 7): once configured for secure data operation, the Spectrum Master cannot be switched between secure and non-secure operation by the user.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Anritsu

Condition

Pre-Owned

Manufacturer

Anritsu

Spec_ana_freq

9 kHz to 43 GHz