The Anritsu Spectrum Master MS2723C is a high performance handheld spectrum analyzer covering 9 kHz to 13 GHz. It is built to deliver the performance needed for demanding measurements in harsh RF and physical environments, packaged in a portable instrument measuring 315 mm x 211 mm x 77 mm (12.4 in x 8.3 in x 3.0 in) and weighing 3.5 kg (7.8 lb).
The MS2723C is positioned for spectrum monitoring, broadcast proofing, interference analysis, RF and microwave measurements, regulatory compliance, and Wi-Fi and wireless network measurements. As a field instrument, it is intended for the wireless professional making fast and reliable measurements where bench equipment is impractical.
ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house by our technicians before it ships, while new units ship factory-sealed exactly as received from the manufacturer. Holding our own stock lets us match the right instrument and condition to your application quickly and back the sale with our own support.
| Specification | Value |
|---|---|
| Frequency | |
| Frequency Range | 9 kHz to 13 GHz (tunable to 0 Hz), Preamp 100 kHz to 13 GHz |
| Tuning Resolution | 1 Hz |
| Frequency Reference Aging | ±1.0 ppm/10 years |
| Frequency Reference Accuracy | ±0.3 ppm (25 °C ±25 °C) + aging |
| Auto-sensing External Frequency Reference | 1, 1.2288, 1.544, 2.048, 2.4576, 4.8, 4.9152, 5, 9.8304, 10, 13, 19.6608 MHz |
| Frequency Span | 10 Hz to 13 GHz including zero span |
| Sweep Time | 10 µs to 600 seconds in zero span |
| Sweep Time Accuracy | ±2 % in zero span |
| Bandwidth (Performance Sweep Mode) | |
| Resolution Bandwidth (RBW) | 1 Hz to 10 MHz in 1–3 sequence ±10 % (–3 dB bandwidth) |
| Video Bandwidth (VBW) | 1 Hz to 10 MHz in 1–3 sequence (–3 dB bandwidth) |
| RBW with Quasi-Peak Detection | 200 Hz, 9 kHz, 120 kHz (–6 dB bandwidth) |
| VBW with Quasi-Peak Detection | Auto VBW is On, RBW/VBW = 1 |
| Spectral Purity — SSB Phase Noise at 1 GHz | |
| @ 10 kHz offset from carrier | –100 dBc/Hz (–104 dBc/Hz typical) |
| @ 100 kHz offset from carrier | –102 dBc/Hz (–107 dBc/Hz typical) |
| @ 1 MHz offset from carrier | –107 dBc/Hz (–114 dBc/Hz typical) |
| @ 10 MHz offset from carrier | –120 dBc/Hz (–129 dBc/Hz typical) |
| Amplitude Ranges | |
| Dynamic Range | > 104 dB @ 2.4 GHz, 2/3 (TOI-DANL) in 1 Hz RBW |
| Measurement Range | DANL to +30 dBm |
| Display Range | 1 to 15 dB/div in 1 dB steps, ten divisions displayed |
| Reference Level Range | –150 dBm to +30 dBm |
| Attenuator Resolution | 0 to 65 dB, 5 dB steps |
| Amplitude Units | Log Scale Modes: dBm, dBV, dBmv, dBµV; Linear Scale Modes: nV, µV, mV, V, kV, nW, µW, mW, W, kW |
| Maximum Continuous Input | +30 dBm Peak, ±50 VDC (≥10 dB Attn); +23 dBm Peak, ±50 VDC (< 10 dB Attn); +13 dBm Peak, ±50 VDC (Preamp On) |
| Amplitude Accuracy (single sine wave input < Ref level, > DANL, auto attenuation, Performance Sweep Mode) | |
| 20 °C to 30 °C after 30 minute warm-up | Typical: ±0.5 dB, 100 kHz to 13 GHz; Maximum: ±1.3 dB, 100 kHz to 13 GHz |
| –10 °C to 50 °C after 60 minute warm-up | Add ±1.0 dB, 100 kHz to 13 GHz |
| Displayed Average Noise Level (DANL) in 1 Hz RBW, 0 dB attenuation | |
| 10 MHz to 4 GHz | Preamp Off: –141 dBm; Preamp On: –160 dBm |
| > 4 GHz to 9 GHz | Preamp Off: –134 dBm; Preamp On: –156 dBm |
| > 9 GHz to 13 GHz | Preamp Off: –129 dBm; Preamp On: –152 dBm |
| Distortion and Spurious | |
| Third-Order Intercept (TOI) @ 2.4 GHz | +15 dBm |
| Third-Order Intercept (TOI) 50 MHz to 13 GHz | +20 dBm typical |
| P1 dB < 4 GHz | +5 dBm typical |
| P1 dB 4 GHz to 13 GHz | +12 dBm typical |
| Second Harmonic Distortion 50 MHz | –54 dBc |
| Second Harmonic Distortion < 4 GHz | –60 dBc typical |
| Second Harmonic Distortion > 4 GHz | –75 dBc typical |
| VSWR (> 10 dB input attenuation), < 13 GHz | 1.5:1 typical |
| Residual Spurs (Preamp Off, RF input terminated) | –90 dBm, 9 kHz to 13 GHz |
| Residual Spurs (Preamp On, RF input terminated) | –100 dBm, 1 MHz to 13 GHz |
| Input-Related Spurs (–30 dBm input, span < 1.7 GHz) | –60 dBc, –70 dBc typical |
| Memory | |
| Internal Trace/Setup Memory | > 13,000 traces |
| External Trace/Setup Memory | Limited by size of USB Flash drive |
| Connectors | |
| RF In | Type N, female, 50 Ω, Maximum Input +30 dBm, ±50 VDC |
| GPS | SMA female |
| External Power | 5.5 mm barrel connector, 12 to 15 VDC, < 5.0 Amps |
| LAN Connection | RJ48C, 10/100 Mbps |
| USB Interface (2) | Type A, Connect Flash Drive and Power Sensor |
| USB Interface | 5-pin mini-B, Connect to PC for data transfer |
| Headset Jack | 2.5 mm 3-wire headset jack |
| External Reference In | BNC, female, 50 Ω, Maximum Input –10 dBm to +10 dBm |
| External Reference Out | BNC, female, 50 Ω, 10 MHz |
| External Trigger | BNC, female, 50 Ω, Maximum Input ±5 VDC |
| IF Out | BNC, female, 50 Ω, 140 MHz |
| Display | |
| Size | 8.4 in |
| Resolution | 800 x 600 |
| Battery | |
| Type | Li-Ion |
| Battery Operation | 3 hours, typical |
| Electromagnetic Compatibility | |
| European Union | CE Mark, EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC and Low Voltage Directive 73/23/EEC, 93/68/EEC |
| Australia and New Zealand | C-tick N274 |
| Interference | EN 61326-1 |
| Emissions | EN 55011 |
| Immunity | EN 61000-4-2/-3/-4/-5/-6/-11 |
| Safety | |
| Safety Class | EN 61010-1 Class 1 |
| Product Safety | IEC 60950-1 when used with company-supplied Power Supply |
| Environmental | |
| Operating Temperature | –10 °C to 55 °C |
| Maximum Humidity | 85 % |
| Shock | MIL-PRF-28800F Class 2 |
| Storage | –51 °C to 71 °C |
| Altitude | 4600 meters, operating and non-operating |
| Size and Weight | |
| Size | 315 mm x 211 mm x 77 mm (12.4 in x 8.3 in x 3.0 in) |
| Weight | 3.5 kg (7.8 lb) |
Important: Maximum continuous input: +30 dBm peak, ±50 VDC (≥10 dB attenuation); +23 dBm peak, ±50 VDC (<10 dB attenuation); +13 dBm peak, ±50 VDC (preamp on).
Important: The High Accuracy Power Meter (Option 19) requires an external USB Power Sensor, which is not included with the base unit and must be ordered separately (e.g., PSN50, MA24105A, MA24106A, MA24108A, MA24118A, or MA24126A).
Important: The GPS Receiver (Option 31) requires an Anritsu GPS antenna (P/N 2000-1528-R or 2000-1652-R), which requires 5 VDC.
Important: Recommended calibration cycle is 12 months.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Anritsu
Condition
Pre-Owned
Manufacturer
Anritsu
Spec_ana_freq
9 kHz to 13 GHz
Request A Quote