Anritsu MS2687B Spectrum Analyzer, 9 kHz to 30 GHz (Pre-Owned)

Anritsu MS2687B Spectrum Analyzer, 9 kHz to 30 GHz (Pre-Owned)

Calibrations
Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Anritsu MS2687B Spectrum Analyzer, 9 kHz to 30 GHz (Pre-Owned)

Key Features At A Glance

  • Frequency range from 9 kHz to 30 GHz, extendable to 110 GHz with external mixers
  • Maximum resolution bandwidth of 20 MHz for wideband signal analysis including Wireless LAN signals
  • Average noise level of ≤–146 dBm/Hz from 1 MHz to 2.5 GHz
  • Sweep refresh rate of 20 trace/s with GPIB data transfer rate of 120 kbytes/s
  • Standard interfaces include GPIB, RS-232C, and Centronics; optional 10BASE-T Ethernet
  • 6.5-inch color TFT-LCD display with PC-compatible memory card slot for measurement data
  • Optional measurement software (sold separately) for W-CDMA, GSM, cdma2000, Wireless LAN, TD-SCDMA and other communication standards
  • Optional rubidium reference oscillator with 7-minute warm-up (Option 05) for field deployment
Share on
View full details

The Anritsu MS2687B is a microwave spectrum analyzer covering 9 kHz to 30 GHz, designed for evaluation of wireless LAN equipment and devices and a broad range of microwave measurement applications. The frequency coverage extends measurement capability up to fifth-order harmonics on 5 GHz Wireless LAN signals, and the instrument can be extended to 110 GHz through the use of external mixers from Anritsu's MA2741A through MA2746A series.

Applications listed for the MS2687B include evaluation of wireless LAN equipment and devices, installation and maintenance of radio stations, maintenance of microwave entrance lines, and development and production line testing of various high-frequency parts. The MS2687B addresses one-touch measurement of occupied bandwidth, channel power, and adjacent channel leakage power, and supports analysis of broadband signals through its wide resolution bandwidth.

ValueTronics International, LLC stocks, tests, and ships test and measurement equipment from our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Every instrument moving through our facility is handled by our team rather than drop-shipped from a third party, which means inventory is verifiable, condition is documented from direct inspection, and questions about a specific unit reach the technicians who actually evaluated it.

Brand Heritage

Anritsu Corporation is a Japanese precision measurement company with roots reaching to 1895. Anritsu's 1993 acquisition of Wiltron Company brought significant RF and microwave measurement technology into the Anritsu portfolio, and current Anritsu RF instruments trace much of their North American commercial presence to that combination.

Accessories Supplied

  • Power cord, 2.6 m (1 pc)
  • J0996B RS-232C cable (1 pc)
  • Z0744 Memory card (32 MB) (1 pc)
  • F0014 Fuse, 6.3 A (1 pc)
  • MX268001A File Transfer Utility (1 pc)
  • W1754AE MS2681A/83A/87B operation manual (1 copy)

Product Core & Specifications

Category Specification Value
Frequency Frequency range 9 kHz to 30 GHz
Frequency band 0 9 kHz to 3.2 GHz (Mixer harmonics order N=1)
Frequency band 1− 3.15 to 6.3 GHz (N=1)
Frequency band 1+ 6.2 to 7.9 GHz (N=1)
Frequency band 2+ 7.8 to 15.3 GHz (N=2)
Frequency band 4+ 15.2 to 30 GHz (N=4)
Pre-selector range 3.15 to 30 GHz (band 1−, 1+, 2+, 4+)
Frequency counter resolution 1 Hz, 10 Hz, 100 Hz, 1 kHz
Frequency span 0 Hz, and 5 kHz to 30 GHz; accuracy ±1.0% (band 0,1), ±2.5% (band 2,4)
Resolution & Video Bandwidth RBW setting range (standard) 300 Hz to 3 MHz (1, 3 sequence), 5 MHz, 10 MHz, 20 MHz (0 band)
RBW accuracy ±20% (300 Hz to 10 MHz), ±40% (20 MHz)
RBW selectivity (60 dB:3 dB) ≤15:1
Video bandwidth (VBW) 1 Hz to 3 MHz (1, 3 sequence), Off
Signal Purity Noise sideband ≤−108 dBc/Hz (1 GHz, 10 kHz offset); ≤−120 dBc/Hz (1 GHz, 100 kHz offset)
Spurious resulting from local cause ≤−65 dBc (at harmonic mixing order 1)
Reference Oscillator (Standard) Frequency 10 MHz
Start-up characteristics ≤5 × 10⁻⁸ (after 10 min warm-up)
Aging rate ≤2 × 10⁻⁸/day, ≤1 × 10⁻⁷/year
Temperature characteristics ±5 × 10⁻⁸ (0 to 50°C, ref. 25°C)
Amplitude Measurement range Average noise level to +30 dBm
Max continuous average power +30 dBm (RF ATT: ≥10 dB)
Peak pulse input +47 dBm (pulse width ≤1 µs, duty ≤1%, RF ATT ≥30 dB)
Max DC voltage 0 Vdc
Average noise level (1 MHz to 2.5 GHz, band 0) ≤−124 dBm + f[GHz] dB
Average noise level (3.15 to 7.9 GHz, band 1) ≤−115 dBm
Average noise level (7.8 to 15.3 GHz, band 2) ≤−113 dBm
Average noise level (15.2 to 30 GHz, band 4) ≤−103 dBm
Reference Level & Attenuator Log scale range −100 to +40 dBm or equivalent level
Linear scale range 2.24 µV to 22.4 V
Reference level accuracy ±0.5 dB (−49.9 to 0 dBm); ±0.75 dB (+0.1 to +30 dBm, −69.9 to −50 dBm); ±1.5 dB (−80 to −70 dBm)
Input attenuator (RF ATT) 0 to 70 dB (10 dB step)
RF ATT switching uncertainty ±0.3 dB (10 to 50 dB), ±0.5 dB (50 to 70 dB)
Frequency Response Relative flatness band 0 ±1.0 dB (9 kHz to 3.2 GHz)
Relative flatness band 1 / 2 / 4 ±1.5 dB / ±3.0 dB / ±4.0 dB
Absolute flatness (RF ATT 10 dB, ref. 50 MHz) ±5.0 dB (9 kHz to 30 GHz)
Spurious Response 2nd harmonic distortion (1.6 to 15 GHz) ≤−90 dBc or lower than average noise level (Mixer input: −10 dBm)
Two-signal third-order intermodulation distortion (0.1 to 3.2 GHz, band 0) ≤−85 dBc (Mixer input: −30 dBm, freq. diff. ≥50 kHz)
Image response ≤−65 dBc (≤18 GHz), ≤−60 dBc (≤22 GHz), ≤−55 dBc (≤30 GHz)
1 dB gain compression ≥0 dBm (≥100 MHz); ≥+3 dBm (≥500 MHz, band 0); ≥−5 dBm (≥3150 MHz, band 1,2,4)
Frequency Sweep Sweep mode Continuous, single
Sweep time 10 ms to 1000 s
Sweep time accuracy ±3%
Trigger source Wide IF video, external (TTL), external (±10 V), line
Gate sweep delay range 0 to 65.5 ms (resolution 1 µs)
Gate length range 2 µs to 65.5 ms (resolution 1 µs)
Time Sweep Sweep mode Continuous, single
Sweep time range 1 to 50 µs (1,2,5 seq.); 100 µs to 4.9 ms; 5.0 ms to 1 s; 1 to 1000 s
Sweep time accuracy ±1%
Trigger source Wide IF video, video, external (TTL), external (±10 V), line
Functions Number of data points Selectable between 501 and 1001
Detection mode NORMAL, POSITIVE PEAK, NEGATIVE PEAK, SAMPLE, AVERAGE
Display functions TRACE A, TRACE B, TRACE A/BG, TRACE A/TIME
Storage functions NORMAL, VIEW, MAX HOLD, MIN HOLD, AVERAGE, CUMULATIVE, OVER WRITE
Multi marker 10 max. (highest 10, harmonics, manually set)
Measure Functions Noise power units dBm/Hz, dBm/CH, dBµV/√Hz
C/N units dBc/Hz, dBc/CH
Occupied bandwidth methods power N% method, X-dB down method
Adjacent channel leakage power REF total power / reference level / in-band level method
Frequency response correction up to 150 points
Display & Storage Display Color TFT-LCD, VGA 17 cm (6.5 inch)
Number of colors 4096, RGB, each 16-scale settable
Intensity Settable in 5 steps (display off included)
Save/recall Internal memory (max. 12) or memory card
PC card interface Type I or Type II PC card (3.3/5 V)
Hard copy PCL level 3 or lower, ESC/P-J83, J84 compatible
Interfaces GPIB Meets IEEE488.2; SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E2
GPIB transfer rate 120 kbytes/s
Parallel interface Centronics-compatible, D-sub 25 pin
RS-232C baud rate 1200, 2400, 4800, 9600, 19.2 k, 38.4 k, 56 k, 115 kbps
Input/Output Connectors RF input connector K-J, 50 Ω nominal, VSWR ≤2.3 Typical (RF ATT ≥10 dB)
Video output analog RGB, D-sub 15-pin
IF output BNC, 50 Ω, 66/10.69 MHz, −10 dBm Typical
Broadband IF output BNC, 50 Ω, 60.69/66 MHz, 0 dB Typical gain
Probe source 4-pole connector, +12 V, −12 V, ±10% each, 110 mA max each
External reference input BNC, 10 MHz ± 10 Hz or 13 MHz ± 13 Hz, ≥0 dBm
General External mixer frequency range 18 to 110 GHz
Dimensions 320 (W) × 177 (H) × 411 (D) mm (handle, leg, front cover, fan cover excluded)
Weight ≤16 kg (nominal value)
Power 100 to 120 / 200 to 240 Vac (−15%/+10%, 250 V max., wide range input); 47.5 to 63 Hz, ≤400 VA
Ambient temperature and humidity 0° to +50°C, RH ≤85% (no condensation allowed)
Important: Maximum input level: continuous average power +30 dBm with RF ATT ≥10 dB; peak pulse input +47 dBm at pulse width ≤1 µs and duty ratio ≤1% with RF ATT ≥30 dB; DC voltage 0 Vdc.Important: Specified values are obtained after warming up the equipment for 30 minutes at a constant ambient temperature and then performing calibration. The typical values are given for reference, and are not guaranteed.Important: Power sensor is optionally available and required for use of the optional power meter function. Applicable power sensors include MA4601A, MA4701A, MA4703A, and MA4705A — these must be ordered separately.Important: External mixers (MA2741A through MA2746A) must be ordered separately to extend frequency coverage up to 110 GHz.Important: Measurement software (MX268xxx series) is sold separately and is required to perform modulation analysis for the various communication systems described in the datasheet.Recommended pairing: when extending coverage above 30 GHz, use the Anritsu MA2741A through MA2746A external mixers listed in the MS2687B ordering information to reach up to 110 GHz.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Anritsu

Condition

Used

Manufacturer

Anritsu

Frequency

30 GHz