Key Features At A Glance

  • Frequency coverage from 1 MHz up to 8, 14, 20, 30, or 40 GHz, depending on the selected frequency option
  • True four-channel receiver design delivering up to 110 dB dynamic range (20 MHz to 40 GHz) and 1 Hz frequency resolution
  • Sweep speed of 650 μs per data point with 1-port RL, VSWR, Cable Loss, DTF, Phase, and Smith Chart measurements
  • 8.4 in daylight-viewable touchscreen in a compact 273 x 199 x 91 mm chassis weighing 3.0 kg (6.6 lb) with battery
  • Ethernet (RJ-45, 10/100) and dual USB interfaces standard for data transfer and PC control
  • Optional Vector Network Analyzer (Option 0440) and Vector Voltmeter (Option 0441) operating modes
  • Standard High Accuracy Power Meter mode (requires external USB power sensor, sold separately)
View full details

The Anritsu S820E Microwave Site Master is a portable handheld cable and antenna analyzer that covers a continuous frequency range starting at 1 MHz and extending up to 8, 14, 20, 30, or 40 GHz depending on the selected frequency option. Built on a true four-channel receiver design, it delivers vector network analyzer performance in a battery-powered, field-portable package, and adds optional VNA and Vector Voltmeter operating modes for users who need capabilities beyond cable-and-antenna line sweeping.

In its standard Cable and Antenna Analyzer role, the S820E performs 1-port measurements including Return Loss, VSWR, Cable Loss, Distance-to-Fault (DTF), Phase, and Smith Chart, along with 2-port Transmission and Cable Loss measurements. Distance-to-Fault locates faults along a transmission line out to a maximum horizontal range of 1500 m (4921 ft), while Phase and Smith Chart measurements are available in Advanced Mode for more detailed impedance characterization.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Holding instruments like the S820E in-house lets our team manage availability and fulfillment directly; every pre-owned unit is handled accordingly, with used units inspected and functionally verified by our technicians while new units ship factory-sealed exactly as received.

Accessories Supplied

  • 2000-1654-R Soft Carrying Case
  • 10920-00060 Anritsu Handheld Instruments Documentation Disc
  • 2300-577 Anritsu Software Tool Box for Handheld RF Instruments Disc
  • 71693-R Ruggedized K(f) to N(f), 2 pcs (included only with S820E-0720)
  • 633-75 Rechargeable Li-Ion Battery
  • 40-187-R AC-DC Adapter
  • 806-141-R Automotive Power Adapter, 12 VDC, 60 W
  • 2000-1691-R Stylus with Coiled Tether
  • 2000-1797-R Screen Protector Film (one factory installed, one spare)
  • 3-2000-1498 USB A/5-pin Mini-B Cable, 3.05 m (10 ft)
  • 2000-1371-R Ethernet Cable, 2.13 m (7 ft)
  • Certificate of Calibration and Conformance

Product Core & Specifications

Specification Value
Frequency (Cable & Antenna Analyzer)
Frequency Range 1 MHz to 8 GHz, 14 GHz, 20 GHz, 30 GHz, 40 GHz (frequency option dependent)
Frequency Accuracy ± 1.0 ppm at 23 °C
Stability ± 1.0 ppm from –10 °C to +55 °C, typical
Aging ± 1.0 ppm/yr, typical
Frequency Resolution 1 Hz
IFBW (Advanced Mode Only) 10 Hz, 100 Hz, 1 kHz, 100 kHz
Output Power High –3 dBm, typical
Output Power Low –20 dBm, typical
RF Immunity +17 dBm, typical (+13 dBm for interfering signals landing in-band)
Measurement (Cable & Antenna Analyzer)
Measurement Speed (Reflection/Transmission) ≤ 650 μs/data point, RF immunity low, typical
Dynamic Range (1 MHz to 20 MHz) ≥ 85 dB (105 dB, typical)
Dynamic Range (>20 MHz to 8 GHz) ≥ 100 dB (115 dB, typical)
Dynamic Range (>8 GHz to 40 GHz) ≥ 100 dB (110 dB, typical)
Receiver Compression (1 MHz to 40 GHz) +5 dBm (0.1 dB compression), typical
High Level Noise Magnitude ± 0.006 dB (± 0.001 dB, typical) rms
High Level Noise Phase ± 0.090° (± 0.060°, typical)
Smoothing Range 0 % to 20 %
System Impedance (Port 1 or Port 2) 50 Ω standard, 75 Ω with 50 Ω to 75 Ω adapter
Measurement Display Ranges
Return Loss 0 dB to 1000 dB, resolution 0.01 dB
VSWR 1 to 1000, resolution 0.01
Cable Loss 0 dB to 500 dB, resolution 0.01 dB
Distance-to-Fault Vertical Range (Return Loss) 0 dB to 1000 dB
Distance-to-Fault Vertical Range (VSWR) 1 to 1000
Distance-to-Fault Horizontal Range 0 to (Data Points – 1) x Fault Resolution, to a maximum of 1500 m (4921 ft)
1-Port Phase –450 ° to +450 °, resolution 0.01 °
Smith Chart Impedance 50 Ω, 75 Ω, resolution 0.01
Cable Loss 2-Port (Classic Mode Only) –1000 dB to +1000 dB, resolution 0.01 dB
Transmission (Advanced Mode Only) –1000 dB to +1000 dB, resolution 0.01 dB
Measurement Accuracy (TOSLK50A-40 or TOSLKF50A-40 calibration kit, Transmission Port 1 to Port 2)
1 MHz to 10 GHz Directivity ≥ 42 dB; Source Match ≥ 33 dB; Load Match ≥ 42 dB; Reflection Tracking ± 0.08 dB; Transmission Tracking ± 0.06 dB
> 10 GHz to 20 GHz Directivity ≥ 36 dB; Source Match ≥ 26 dB; Load Match ≥ 36 dB; Reflection Tracking ± 0.04 dB; Transmission Tracking ± 0.03 dB
> 20 GHz to 30 GHz Directivity ≥ 32 dB; Source Match ≥ 22 dB; Load Match ≥ 32 dB; Reflection Tracking ± 0.04 dB; Transmission Tracking ± 0.03 dB
> 30 GHz to 40 GHz Directivity ≥ 30 dB; Source Match ≥ 20 dB; Load Match ≥ 30 dB; Reflection Tracking ± 0.04 dB; Transmission Tracking ± 0.03 dB
Vector Network Analyzer (Option 0440)
Measurement (S-Parameter) S11, S21, S12, S22
Graph Types Log Magnitude, SWR, Phase, Real, Imaginary, Group Delay, Smith Chart, Inverted Smith Chart, Log Mag/2, Real/Imaginary Impedance
Data Points 2 to 4001 (arbitrary setting)
Data Averaging Sweep-by-Sweep, 1 to 1000
IF Bandwidth (Hz) 10, 20, 50, 100, 200, 500, 1k, 2k, 5k, 10k, 20k, 50k, 100k
Measurement Speed ≤ 650 μs/pt (S11 and S21, 1001 points, 100 kHz IFBW, RF immunity low, typical)
Timebase Reference Internal (default), External 10 MHz (Auto-sense, BNC female, Max +10 dBm)
Vector Voltmeter (Option 0441)
Reference Level Input Range (A/B and B/A) +5 dBm to –60 dBm (auto ranging), typical
Ratio Accuracy (1 MHz to 1 GHz) ≤ ± 0.2 dB typical (DUT loss <10 dB)
Ratio Accuracy (>1 GHz to 20 GHz) ≤ ± 0.5 dB typical (DUT loss <10 dB)
Ratio Accuracy (>20 GHz to 40 GHz) ≤ ± 1.0 dB typical (DUT loss <10 dB)
Phase Display Range ± 180°
General Specifications
Internal Trace/Setup Memory >2000 files
Display Type High Resolution Resistive Touchscreen
Display Size 8.4 in daylight viewable color LCD
Display Resolution 800 x 600
Port 1 / Port 2 (models up to 14 GHz) Type N, female, 50 Ω, Maximum Input +23 dBm, ±50 VDC
Port 1 / Port 2 (models > 14 GHz) Type Ruggedized K, male, 50 Ω, Maximum Input +23 dBm, ±50 VDC
External Reference In BNC female, 50 Ω, 10 MHz, Maximum +10 dBm
External Trigger In BNC female, 50 Ω, 3.3 V or 5 V TTL triggers on positive edge, Maximum +5 VDC
External Power 5.5 mm barrel connector, +11 VDC to +14 VDC, ≤ 4.0 A
USB Interface (2) Type A (USB Flash Drive, GPS Module, Power Sensor, other)
USB Interface 5-pin Mini-B (Connect to PC for data transfer and/or control)
Ethernet RJ-45, Category 5, 10/100 MB/s
Battery Type Li-Ion
Battery Operation 6.0 hr, typical
Operating Temperature –10 ºC to +55 ºC
Storage Temperature –51 ºC to +71 ºC
Maximum Relative Humidity 95 %, non-condensing
Mechanical Shock MIL-PRF-28800F Class 2
Altitude 4600 m (15092 ft), operating and non-operating
EMC CE Mark; Emissions EN 55011:2009 +A1:2010 Group 1 Class A; Immunity EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-11
Safety CE Mark; EN 61010-1:2010
Size 273 mm x 199 mm x 91 mm (10.7 in x 7.8 in x 3.6 in)
Weight 3.0 kg (6.6 lb), including battery
Important: Maximum input: +23 dBm, ±50 VDC (Port 1 and Port 2).
Important: The High Accuracy Power Meter mode requires an external Anritsu USB power sensor, which is sold separately (see USB Power Sensors ordering information).
Important: 2-port cable loss / transmission (external sensor) measurements require an external USB transmission sensor (e.g. SC8268) or USB power sensor, sold separately.
Important: The S820E requires one Frequency Option (0708, 0714, 0720, 0730, or 0740) to be selected; ports are Type N(f) on models up to 14 GHz and Type Ruggedized K(m) on models above 14 GHz.
Important: Standard configuration includes a Three Year Warranty (One year on battery).

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Anritsu

Condition

Pre-Owned

Manufacturer

Anritsu

Cabant_ana_freq

1 MHz to 40 GHz