Skip to content

The Amprobe PM55A is a compact precision digital multimeter built around two signature features: AutoTect and VolTect. It is described as a shirt-pocket sized meter, only 3/8 inch thick and weighing less than 3 ounces, that delivers full multimeter functionality in a form factor far smaller than typical bench or field DMMs. Despite its size, it is fully autoranging and offers nine different measurement functions.
A digital multimeter measures fundamental electrical parameters — voltage, current, resistance, and related quantities — making it one of the most universal diagnostic tools on an electronics or electrical bench. The PM55A covers AC and DC voltage, AC and DC current, resistance, capacitance, frequency, diode test, and continuity with beeper, and adds non-contact AC voltage detection. Its AutoTect feature directs the meter to recognize whether it is measuring AC volts, DC volts, or resistance based on the test point the leads are connected to, with no user interface step required.
ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Holding our own inventory lets us match the right instrument and condition to a customer's application and ship it directly.
Amprobe is a long-established test-tools brand that became part of the Fluke family of brands following its acquisition by Danaher Corporation in 2007; the Fluke group subsequently moved under Fortive Corporation when that company was spun off from Danaher in 2016.
| Specification | Value |
|---|---|
| DC Voltage | |
| 6.000 V | ± (0.5 % + 3 dgt) |
| 60.00 V | ± (1.0 % + 5 dgt) |
| 600 V (AutoTect™ Lo-Z) | 2.0 % |
| 600 V (Hi-Z only) | 1.5 % + 5 dgt |
| NMRR | > 30 dB @ 50 Hz/60 Hz |
| CMRR | > 100 dB @ DC, 50 Hz/60 Hz; Rs=1 kΩ |
| Input impedance (AutoTect™ Lo-Z V DC) | 833 kΩ (4.2 kΩ when displaying AUTO), 90 pF nom. |
| V DC AutoTect™ threshold | > +1.2 V DC or < -0.6 V DC nominal (Hi-Z V DC only) |
| AC Voltage (50 Hz - 60 Hz) | |
| 6.000 V, 60.00 V, 600 V | ± (1.5 % + 5 dgt) |
| CMRR | > 60 dB @ DC to 60 Hz, Rs=1 kΩ |
| Input impedance (AutoTect™ Lo-Z V AC) | 160 kΩ, 160 pF nominal |
| Hi-Z ACV | 5 MΩ, 90 pF nominal |
| ACV AutoTect™ threshold | > 1.5 V ac (50 Hz/60 Hz) nominal |
| Capacitance | |
| 100.0 nF, 1000 nF, 10.0 µF, 100.0 µF, 2000 µF | ± (3.5 % + 6 dgt) |
| Notes | Accuracy below 50 nF is not specified; accuracies with film capacitor or better; updates > 1 minute on large values; specified with battery voltage above 2.8 V (half full battery), accuracy decreases gradually to 12% at low battery warning voltage of approx. 2.4 V. |
| Resistance | |
| 600.0 Ω | ± (2.0 % + 6 dgt) |
| 6.000 kΩ | ± (1.2 % + 6 dgt) |
| 60.00 kΩ, 600.0 kΩ | ± (1.0 % + 4 dgt) |
| 6.000 MΩ | ± (2.0 % + 4 dgt) |
| Open circuit voltage | 0.4 V DC typical |
| AutoTect™ range | 6.000 kΩ ~ 6.000 MΩ ranges |
| Note | Add 40 dgt to specified accuracy while reading is below 20 % of range |
| Frequency | |
| 10.00 Hz - 30.00 kHz | ± (0.5 % + 4 dgt), < 20 V Sine-rms |
| 10.00 Hz - 999.9 Hz | ± (0.5 % + 4 dgt), < 600 V Sine-rms |
| DC µA Current | |
| 400.0 µA | ± (1.5 % + 3 dgt); Burden voltage 6 mV/µA |
| 2000 µA | ± (1.2 % + 3 dgt); Burden voltage 6 mV/µA |
| AC µA Current | |
| 400.0 µA | ± (2.0 % + 3 dgt); Burden voltage 6 mV/µA |
| 2000 µA | ± (1.5 % + 3 dgt); Burden voltage 6 mV/µA |
| VolTect™ | |
| 15 V to 55 V | – |
| 30 V to 85 V | – – |
| 55 V to 145 V | – – – |
| 85 V to 190 V | – – – – |
| above 120 V | – – – – – |
| Indication | Bar graph segments & audible beep tones proportional to field strength |
| Detection frequency | 50/60 Hz |
| Detection antenna | Top left corner of the meter |
| Audible Continuity Tester (600 Ω range) | |
| Open circuit voltage | 0.4 V DC typical |
| Audible threshold | 50 Ω to 300 Ω |
| Diode Test | |
| Diode test current | 0.48 mA |
| Open circuit voltage | < 1.6 V DC |
| General Specifications | |
| Display and update rate | 3-5/6 digits 6000 counts; Updates 5 per second nominal |
| RF field @ 3 V/m | Specified accuracy + 45 d (capacitance not specified) |
| Operating temperature | 0 °C - 40 °C |
| Relative humidity | Max. 80 % R.H. up to 31 °C, decreasing linearly to 50 % R.H. at 40 °C |
| Altitude | Operating below 2000 m |
| Storage temperature | -20 °C ~ 60 °C, < 80 % R.H. (with battery removed) |
| Temperature coefficient | Nominal 0.15 x (specified accuracy)/ °C @ (0 °C ~ 18 °C or 28 °C ~ 40 °C) |
| Sensing | Average sensing |
| Overload protection | 600 V DC and V AC RMS |
| Low battery | Below approx. 2.4 V |
| Power supply | 3 V standard button battery x 1 (IEC-CR2032; ANSI-NEDA-5004LC) |
| Power consumption (typical) | 6 mA for voltage functions on Auto-V Ω position & 2 mA for other functions |
| Automatic Power Off (APO) timing | Idle for 3 minutes |
| APO consumption (typical) | 2.2 µA |
| Dimension | L 113 mm x W 53 mm x H 10.2 mm (4.4 x 2.1 x 0.4 in) |
| Weight | Approx. 78 g (3 oz) |
| Special features | AutoTect™ (Automatic V & Ω selection) and VolTect™ (Electric Field Detection) |
| Agency approvals | CE, cULus |
| Safety | Meets IEC61010-1, UL61010B-1, CAN/CSA-C22.2 No. 1010.1-92, CAT II 600 V and CAT III 300 V, Pollution Degree 2, Class 2 |
| E.M.C. | Meets EN61326 |
Important: Overload protection: 600 V DC and AC RMS.
This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Amprobe
Condition
Factory New
Manufacturer
Amprobe
Multi_met_acv
600 V
Multi_met_dcv
600 V
Multi_met_dig
3-5/6 digits (6000 counts)
Request A Quote