HP 85644A 300 kHz to 6.5 GHz Tracking Source (Pre-Owned)

Key Features At A Glance

  • Frequency range from 300 kHz to 26.5 GHz (HP 85645A); 300 kHz to 6.5 GHz (HP 85644A)
  • Maximum leveled power output up to +10 dBm depending on band and model
  • Selectable AC or DC coupling on HP 85645A; AC coupling on HP 85644A
  • Offset frequency tracking range up to ±200 MHz with spectrum analyzer hosts
  • Compatible with HP 8560 Series, 8566A/B, 8590 Series spectrum analyzers and HP 8340A/B, 8350 Series sources
  • Stand-alone CW signal generation with 250 kHz frequency resolution; no host instrument required
  • Power sweep capability over greater than 16 dB range (bands 0-3) for saturation characterization
  • Maximum sweep speed of 250 MHz/ms with 0.01 dB amplitude resolution
Share on
View full details

The HP 85645A is a tracking source covering 300 kHz to 26.5 GHz, designed as a general-purpose accessory for spectrum analyzers (referred to as the host instrument). Combined with a host spectrum analyzer, the tracking source enables measurement of the swept amplitude response of devices such as amplifiers and filters. Because the spectrum analyzer is a tuned receiver, these measurements deliver high dynamic range and speed and are not affected by spurious signals or harmonics. The HP 85645A allows the user to choose either AC or DC coupling and provides selectable RF output power.

Listed applications for the HP 85644A and HP 85645A tracking sources include swept amplitude response measurements of amplifiers and filters, amplitude response measurements of frequency translation devices such as mixers and of systems with delays such as satellite links (using offset tracking), swept third-order-intercept (TOI) measurements when two tracking sources are set to appropriate offset frequencies, and power sweep measurements for characterizing the saturation effects of devices under test. The tracking sources can also generate stand-alone, non-synthesized CW signals at fixed frequencies of the user's choosing with no connections to a host instrument required. Combined with a transducer, the tracking source can perform swept measurements of circuit immunity to electromagnetic interference (EMC).

Brand Heritage

Hewlett-Packard's test and measurement division was spun out as Agilent Technologies in 1999, and the electronic measurement portion of Agilent became Keysight Technologies in 2014. HP-branded instruments such as the HP 85644A and HP 85645A trace through this lineage; service, calibration, and documentation references that originated under HP are typically continued through the Keysight organization today.

Compare Other Models in This Series

The HP 85644A and HP 85645A are companion tracking sources sharing the same operating concept: pair the source with a host spectrum analyzer to perform swept amplitude response measurements of amplifiers, filters, and other components. Both models offer a configuration menu, accessible from the front panel or via HP-IB, that selects the compatible host instrument and matches the source's behavior to that host.

The two models differ in two principal dimensions: frequency coverage and coupling. The HP 85644A covers 300 kHz to 6.5 GHz and is AC coupled. The HP 85645A extends coverage to 26.5 GHz and allows the user to choose AC or DC coupling. Both share the same I/O architecture, the same offset tracking and power sweep features, and the same environmental and calibration specifications.

Each pre-owned HP 85644A or HP 85645A in our inventory is listed as a separate product page with its own condition assessment, accessory list, and pricing. The model best suited to a given application depends on the customer's frequency coverage requirement, coupling preference, and host instrument; the linked pages below allow direct comparison of the two models within the family.

The HP 85645A is the wider-coverage model in the family, reaching 26.5 GHz with selectable AC or DC coupling. Its maximum leveled power output reaches +10 dBm in band 1 (2.0 to 7.0 GHz), and its dynamic range with an HP 8566A/B host reaches 141 dB in band 0. The HP 85645A uses an SMA (f) front-panel RF output.

The HP 85644A's 6.5 GHz coverage is appropriate for applications confined to the lower microwave range; the HP 85645A's 26.5 GHz coverage adds bands 2, 3, and 4 (covering ranges that extend through 13.5 GHz, 20.0 GHz, and 26.5 GHz respectively, with maximum leveled output of +5 dBm, +5 dBm, and -2 dBm). The HP 85645A's selectable DC coupling is the option to specify when measurements must extend below the AC-coupled lower limit of 10 MHz down to 300 kHz.

Other differences follow from this: the HP 85644A has a 70 dB attenuator range with characteristic accuracy of 1.2 dB maximum; the HP 85645A has a 60 dB range with 1.9 dB maximum characteristic accuracy. The HP 85644A is rated at <150 VA / <80 W and 10 kg nominal weight; the HP 85645A is rated at <200 VA / <110 W and 12 kg nominal weight. See the comparison table below for the band-by-band specifications.

Model Frequency Range Max Leveled Power Min Leveled Power
85644A 300 kHz to 6.5 GHz +10 dBm -80 dBm
85645A 300 kHz to 26.5 GHz +10 dBm -70 dBm

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification Value
Amplitude
Maximum Leveled Power Output, band 0 (300 kHz to 1.8 GHz) +10 dBm
Maximum Leveled Power Output, band 0 (1.8 to 2.9 GHz) +4 dBm
Maximum Leveled Power Output, band 1 (2.0 to 6.5 GHz) +5 dBm
Minimum Leveled Power Output (characteristic) -80 dBm
Amplitude Resolution 0.01 dB
Vernier Range, Bands 0 to 3 (characteristic) >16 dB
Output Signal Flatness ±2 dB
Amplitude Accuracy (at -2 dBm, 20-30°C) ±1 dB
Attenuator Range 70 dB
Attenuator Accuracy (characteristic) 1.2 dB maximum, over 70 dB
Power Sweep Maximum Range (0 to 10 V), band 0 to 3 >16 dB
Power Sweep Slope 0 to 3 dB/V
Harmonics, band 0 (>5 MHz) -25 dBc
Harmonics, band 1 -15 dBc
Maximum Sweep Speed 250 MHz/ms
External AM rates (characteristic) >1 kHz, up to 50 kHz available in some settings
Frequency
Frequency Range 300 kHz to 6.5 GHz
Coupling AC coupled
CW Frequency Accuracy (characteristic) ±5 MHz × N
CW Frequency Resolution 250 kHz
Maximum Offset Tracking Range (spectrum analyzer hosts) ±200 MHz
Offset Tracking Resolution 10 Hz × N
Inputs and Outputs (Front Panel, characteristic)
RF Output Connector Type N (f)
VSWR, 300 kHz to 2.9 GHz (0 dB attenuation) 1.8:1
VSWR, 2.9 GHz to 6.5 GHz (0 dB attenuation) 1.6:1
LO Input SMA (f), >-10 dBm, required for tracking
LO Output SMA (f), >+7 dBm, used for tracking with second tracking source
Rear Panel (characteristic)
10 MHz Input BNC (f), >-10 dBm
SWP + TUNE IN BNC (f), required for tracking
SWP + TUNE OUT BNC (f)
HI SWEEP IN/OUT BNC (f)
BLANK IN BNC (f)
SWEEP IN BNC (f), 0 to 10 V
EXT ALC BNC (f)
AUX 9-pin, D-type connector
General
Warmup 30 minutes, from ambient temperature
Calibration Interval 2 years
Temperature (Operating) -10°C to 55°C
Temperature (Non-operating) -51°C to 71°C
Humidity Type tested at 95% relative humidity and 40°C for 5 days
Altitude (Operating) 15,000 feet
Altitude (Non-operating) 50,000 feet
Power Requirements 115 V ac 110 V ±10% / 120 V ±10%, 1.6 A rms max, 47 to 66 Hz, 400 Hz
Power Requirements 230 V ac 220 V ±10% / 240 V ±10%, 0.8 A rms max, 47 to 66 Hz
Power Dissipation (nominal) <150 VA, <80 W
Weight (nominal) 10 kg (22 lb)
Dimensions Standard (H × W × D) 138 mm (5.5 in) × 337 mm (13.5 in) × 461 mm (18.3 in)
Important: Tracking operation requires an external 10 MHz reference input (>-10 dBm) at the rear-panel 10 MHz Input for narrower resolution bandwidths and for the low-frequency band (band 0), an LO Input of >-10 dBm at the front-panel SMA connector, and the rear-panel SWP+TUNE IN connection. HI SWEEP IN/OUT is also required for tracking with some hosts, including the HP 8590 Series spectrum analyzers.Important: A host instrument (spectrum analyzer or sweep oscillator) is required for tracking operation. Compatible hosts listed in the datasheet include HP 8560 Series, HP 8566A/B, HP 8590 Series portable spectrum analyzers, HP 8340A/B synthesized sweepers, and HP 8350 Series sweep oscillators.Important: An LO Input signal of >-10 dBm is required at the front-panel SMA connector for tracking operation.Important: A 10 MHz reference input of >-10 dBm at the rear-panel BNC connector is required for tracking in narrower resolution bandwidths and for the low frequency band (band 0).Important: Frequency ranges of the bands vary with the host instrument selected.Important: Specifications apply with the instrument ac coupled and on a 2-year calibration cycle after 30 minutes of warmup from ambient temperature.Recommended pairing: configure the HP 85645A with one of the datasheet's listed compatible host instruments — the HP 8560 Series portable spectrum analyzers, HP 8566A/B spectrum analyzers, HP 8590 Series portable spectrum analyzers, HP 8340A/B synthesized sweepers, or HP 8350 Series sweep oscillators — using the front-panel configuration menu or HP-IB.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

HP

Condition

Used

Manufacturer

Agilent