Key Features At A Glance

  • 12-bit, 40 MSa/s direct digital synthesis with four 16k-deep arbitrary waveform memories
  • 15 MHz sine and square wave outputs, with a 100 µHz low-frequency floor
  • Built-in sine, square, triangle, ramp, noise, sin(x)/x, exponential rise/fall, cardiac, and DCV waveforms
  • Internal AM/FM/FSK/Burst modulation plus internal linear and logarithmic sweep
  • Output isolated from earth ground (42 Vpk maximum) to minimize ground loops and common-mode noise
  • C-size, 1-slot, message-based VXI module with VXIplug&play Win 95/NT framework support
  • Optional high-stability TCXO timebase and external phase lock (Option 001) for 0.1 ppm/month stability
View full details

The Agilent E1441A is an arbitrary waveform generator implemented as a C-size, single-slot, message-based VXI module. It uses direct digital synthesis to generate its output, an approach that lets it deliver broad waveform functionality from a compact modular form factor. Beyond fixed standard functions, it allows the user to design and store custom arbitrary waveforms.

An arbitrary waveform generator produces user-defined and standard electrical waveforms that serve as controllable stimulus signals for a device or system under test. The E1441A's output is isolated from earth ground, which minimizes ground loops and other common-mode noise in the measurement setup.

ValueTronics stocks and holds its own test-and-measurement inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit we offer is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer. Keeping inventory on hand in our own facility lets us match the right instrument and condition to each customer's requirement directly.

Brand Heritage

Agilent Technologies originated as the test-and-measurement business of Hewlett-Packard, which was spun out as a separate company named Agilent Technologies in 1999. That electronic measurement business was subsequently established as Keysight Technologies in 2014.

Product Core & Specifications

Specification Value
Frequency Characteristics
Sine 100 µHz - 15 MHz
Square 100 µHz - 15 MHz
Triangle 100 µHz - 100 kHz
Ramp 100 µHz - 100 kHz
Noise (Gaussian) 10 MHz bw
Waveforms (points): 8 to 8,192 100 µHz - 5 MHz
Waveforms (points): 8,193 to 12,287 100 µHz - 2.5 MHz
Waveforms (points): 12,288 to 16,000 100 µHz - 200 kHz
Resolution 10 µHz or 10 digits
Resolution accuracy (18 to 28° C), 90 days 10 ppm
Resolution accuracy (18 to 28° C), 1 year 20 ppm
Temperature coefficient <2 ppm/°C
Aging <10 ppm/yr
Sinewave Spectral Purity
Harmonic distortion: dc to 20 kHz <-70 dBc
Harmonic distortion: 20 kHz to 100 kHz <-60 dBc
Harmonic distortion: 100 kHz to 1 MHz <-45 dBc
Harmonic distortion: 1 MHz to 15 MHz <-35 dBc
Total harmonic distortion: dc to 20 kHz <0.04%
Spurious (non-harmonic): Output (dc to 1 MHz) <-65 dBc
Spurious (non-harmonic): Output (>1 MHz) <-65 dBc + 6dB/octave
Phase noise <-52 dBc in a 30 kHz band
Signal Specifications
Square wave: Rise/fall time <20 ns
Square wave: Overshoot <4%
Square wave: Asymmetry <1% + 5 ns
Square wave: Duty cycle 20% to 80% (to 5 MHz), 40% to 60% (to 15 MHz)
Triangle, ramp, arbitrary: Rise/fall time <100 ns (typical)
Triangle, ramp, arbitrary: Linearity <0.1% of peak output
Triangle, ramp, arbitrary: Settling time <250 ns to 0.5% of final value
Triangle, ramp, arbitrary: Jitter <25 ns
Output Characteristics
Amplitude (into 50 Ω) 50 mVp-p to 10 Vp-p, 100 mVp-p to 20 Vp-p into open-circuit load
Accuracy (at 1 kHz) ± 1% of specified output
Flatness (sine wave relative to 1 kHz): <100 kHz ± 1% (0.1 dB)
Flatness: 100 kHz to 1 MHz ± 1.5% (0.15 dB)
Flatness: 1 MHz to 15 MHz ± 2% (0.2 dB)
Offset (into 50 Ω) (Offset ≤2X peak-to-peak amplitude) ± 5 Vpk ac + dc
Offset Accuracy (for square wave outputs, add 2% of output amplitude additional error) ± 2% of setting + 2 mV
Output impedance 50 Ω fixed
Resolution 3 digits, amplitude and offset
Output units Vp-p, Vrms, dBm
Isolation 42 Vpk maximum to earth
Protection Short-circuit protection, ± 15 Vpk overdrive <1 minute
Waveforms (Product Specifications)
Built-in waveforms Sine, square, triangle, ramp, noise, DCV, sine(x)/x, negative ramp, exponential rise, exponential fall, cardiac
Arbitrary waveform: Length 8 to 16,000 points
Arbitrary waveform: Resolution 12 bits (including sign)
Arbitrary waveform: Sample rate 40 MSa/s
Non-volatile memory Four (4) 16k waveforms
Modulation Specifications
AM modulation: Carrier (3 dB frequency) 15 MHz (typical)
AM modulation: Modulation Any internal waveform plus arbitrary
AM modulation: Frequency 10 mHz to 20 kHz (± 0.05% to 2.5 kHz, then decreases linearly to ± 0.4% at upper limit)
FM modulation: Modulation Any internal waveform plus arbitrary
FM modulation: Frequency 10 mHz to 10 kHz (± 0.05% to 600 Hz, then decreases linearly to ± 0.8% at upper limit)
FM modulation: Peak deviation 10 mHz to 15 MHz
FM modulation: Source Internal only
Burst modulation: Carrier frequency 5 MHz max.
Burst modulation: Count 1 to 50,000 cycles, or infinite
Burst modulation: Start phase -360° to + 360°
Burst modulation: Internal rate 10 mHz to 50 kHz ± 1%
Burst modulation: Gate source Internal or external gate
Burst modulation: Trigger source Single, external, or internal rate
FSK modulation: Frequency range 10 mHz to 15 MHz (± 0.05% to 600 Hz, then decreases linearly to ± 4% at upper limit)
FSK modulation: Internal rate 10 mHz to 50 kHz
FSK modulation: Source Internal/external (1 MHz max.)
FSK modulation: Internal rate 10 mHz to 50 kHz ± 1%
Auxiliary Inputs
External AM modulation ± 5 Vpk = 100% modulation
Input resistance 5 kΩ nominal
Ext. trigger/FSK/Burst rate (Trigger source ignored when External Gate is selected) TTL (high true)
Ext. trigger/FSK/Burst rate: Latency 1.3 µs
Ext. trigger/FSK/Burst rate: Jitter 25 ns
VXI TTL Trigger/FSK/Burst rate TTL (low true)
VXI TTL Trigger/FSK/Burst rate: Latency 1.15 µs
VXI TTL Trigger/FSK/Burst rate: Jitter 25 ns
General Characteristics
Function change (Modulation or sweep off) 80 mS
Frequency change (Modulation or sweep off) 30 mS
Amplitude change 30 mS
Offset change 20 mS
Modulation parameter change <350 mS
Select user arbitrary 550 mS
Warm-up time 30 min
Arbitrary waveforms Stored separately
User-configurable stored states 4
Option 001 Phase Lock/TCXO Timebase
Description Adds high stability reference, phase lock to second E1441A and control phase offset
Stability ± 1 ppm, 0 to 50° C
Aging <2 ppm/month in first 30 days, 0.1 ppm/month after 30 days
Ext. ref. input lock range 10 MHz ± 50 Hz
Phase offset -360° to + 360°, 0.001° resolution
VXI Characteristics
VXI device type Message based
Data transfer bus A16, slave only
Size C
Slots 1
Connectors P1/P2
Shared memory No
VXI buses No
Important: Output isolation: 42 Vpk maximum to earth.
Important: Output amplitude and offset specifications apply over 18° C to 28° C; add 1/10th of the output amplitude and offset specification per ° C for operation outside this range.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Pre-Owned

Manufacturer

Agilent Technologies

Arb_gen_freq

15 MHz

E1441A-001

Phase lock/TCXO timebase.