Agilent 33522A 30 MHz 2-Channel Function/Arbitrary Waveform Generator (Pre-Owned)

Agilent 33522A 30 MHz 2-Channel Function/Arbitrary Waveform Generator (Pre-Owned)

Calibrations
Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Agilent 33522A 30 MHz 2-Channel Function/Arbitrary Waveform Generator (Pre-Owned)

Key Features At A Glance

  • 30 MHz sine, square, and pulse bandwidth covers a broad range of bench and design applications
  • Less than 40 ps rms cycle-to-cycle jitter on square/pulse and 0.04% THD (20 Hz to 20 kHz) for high signal fidelity
  • 250 MSa/s sample rate with 16-bit vertical resolution for arbitrary waveform generation
  • True point-by-point arbitrary waveforms with multi-segment sequencing (up to 512 steps)
  • 1 MSa standard arbitrary waveform memory per channel, expandable to 16 MSa with Option 002
  • Dual-channel operation with independent, coupled, combined, equal, or differential modes
  • AM, FM, PM, FSK, BPSK, PWM, and Sum modulation; Gaussian noise and PRBS standard waveforms
  • LXI Class C compliant with 10/100Base-T LAN and USB 2.0 standard; GPIB available as Option 400
Share on
View full details

The Agilent 33522A is a two-channel 30 MHz function/arbitrary waveform generator in the 33500 Series, designed to generate sine, square, pulse, ramp, triangle, Gaussian noise, PRBS, and DC waveforms as well as user-defined arbitrary waveforms. The instrument combines a 250 MSa/s sample rate with 16-bit vertical resolution and provides 1 MSa of arbitrary waveform memory per channel as standard, with expansion to 16 MSa available through Option 002.

A function/arbitrary waveform generator creates the controlled stimulus signals used to characterize and verify electronic circuits and systems. The 33522A targets applications cited on its datasheet including dual-tone multi-frequency (DTMF) signal generation for telecommunications device test, and dual-channel testing scenarios such as pacemaker validation where the timing and interaction of two distinct signals must be controlled. The 33500 Series is positioned for both R&D engineers characterizing new designs and test system engineers validating production units.

ValueTronics International has supported the test and measurement community since 1992 and stocks new, used, and refurbished instruments at our 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit moves through our facility for inspection, functional verification, and condition grading by our own technicians before listing—work that drop-shipping resellers and broker marketplaces cannot replicate because they never physically handle the equipment. Buyers who need a signal source backed by a real US facility, a real technician's measurement, and a real phone number for post-sale questions get all three from ValueTronics.

Brand Heritage

Hewlett-Packard's test and measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent's electronic measurement business became Keysight Technologies, while Agilent retained life sciences and chemical analysis. Instruments originally branded Agilent—including the 33521A and 33522A—are part of the lineage that continues today under Keysight Technologies.

Compare Other Models in This Series

The Agilent 33500 Series consists of two 30 MHz function/arbitrary waveform generators that share the same core architecture, signal fidelity specifications, and modulation capabilities. Both models deliver 250 MSa/s sample rate, 16-bit vertical resolution, less than 40 ps rms cycle-to-cycle jitter on square and pulse outputs, and less than 0.04% THD on sine outputs from 20 Hz to 20 kHz.

The two models differ in channel count. The 33521A is a single-channel instrument; the 33522A is a two-channel instrument that adds parameter coupling, combined-output, equal-channel, and differential operation modes. Both models accept the same option set: Option 002 (16 MSa memory per channel), Option 010 (OCXO high-stability timebase), and Option 400 (GPIB interface).

Each pre-owned model in the 33500 Series is listed on its own product page with condition-matched pricing. Use the links below to navigate to the model that fits the channel count, options, and budget for your application.

The 33522A is the dual-channel member of the 33500 Series. In addition to all single-channel capabilities, it supports independent operation per channel, parameter coupling (frequency ratio or difference, amplitude, and DC offset), combined output (Ch 1 + Ch 2), equal channels (Ch 2 = Ch 1), and differential operation (Ch 2 = -Ch 1). Relative phase is settable from 0° to 360° in 0.1° steps with typical skew under 200 ps when performing identical operations and typical crosstalk below -85 dB.

The primary architectural difference between the 33521A and 33522A is channel count: one channel versus two. The 33522A's dual-channel modes enable applications that require two phase-correlated or differential signals from a single instrument, including the DTMF and dual-signal device test scenarios cited on the datasheet.

Beyond channel count, both models share identical specifications for bandwidth, sample rate, jitter, THD, modulation capability, memory depth (with the same Option 002 expansion path), connectivity, and operating environment. The comparison table below lists the key parameters that differ between the two models.

Model Channels Bandwidth Sample Rate
33522A 2 30 MHz 250 MSa/s
33521A 1 30 MHz 250 MSa/s

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Category Specification Value
Waveforms Standard Sine, square, ramp, pulse, triangle, Gaussian noise, PRBS (Pseudorandom Binary Sequence), DC
Built-in arbitrary Cardiac, exponential fall, exponential rise, Gaussian pulse, Haversine, Lorentz, D-Lorentz, negative ramp, sinc
User-defined arbitrary Up to 1 MSa (16 MSa with Option 002) with multi-segment sequencing
Operating modes Continuous, modulate, frequency sweep, burst, output gate
Modulation types AM, FM, PM, FSK, BPSK, PWM, Sum (carrier + modulation)
Sine Frequency range 1 μHz to 30 MHz, 1-μHz resolution
Amplitude flatness (relative to 1 kHz) < 100 kHz: ±0.10 dB; 100 kHz to 5 MHz: ±0.15 dB; 5 to 20 MHz: ±0.30 dB; 20 to 30 MHz: ±0.40 dB
Harmonic distortion (typ) < 20 kHz: < -70 dBc; 20 to 100 kHz: < -65 dBc; 100 kHz to 1 MHz: < -50 dBc; 1 to 20 MHz: < -40 dBc; 20 to 30 MHz: < -35 dBc
THD (typ) 20 Hz to 20 kHz: < 0.04%
Non-harmonic spurious (typ) Standard: < -75 dBc, increasing +20 dB/decade above 2 MHz; Option 010: < -75 dBc, increasing +20 dB/decade above 10 MHz
Phase noise (SSB) (typ) 1 kHz offset: -105 dBc/Hz (std), -110 dBc/Hz (Opt 010); 10 kHz offset: -115 dBc/Hz (std), -125 dBc/Hz (Opt 010); 100 kHz offset: -125 dBc/Hz (std), -135 dBc/Hz (Opt 010)
Square & Pulse Frequency range 1 μHz to 30 MHz, 1 μHz resolution
Rise and fall times (nom) Square: 8.4 ns fixed; Pulse: 8.4 ns to 1 μs, independently variable, 100-ps or 3-digit resolution
Overshoot (typ) < 2%
Duty cycle 0.01% to 99.99%
Jitter (cycle-to-cycle, typ) < 40 ps rms
Ramp & Triangle Frequency range 1 μHz to 200 kHz, 1 μHz resolution
Ramp symmetry 0.0% to 100.0%, 0.1% resolution
Nonlinearity (typ) < 0.05% from 5% to 95% of signal amplitude
Gaussian Noise Bandwidth (typ) 1 mHz to 30 MHz, variable
Crest factor (nom) 4.6
Repetition period > 50 years
PRBS Bit rate 1 mbps to 50 Mbps, 1 mbps resolution
Sequence length 2^m -1, m=7, 9, 11, 15, 20, 23
Rise and fall times (nom) 8.4 ns to 1 μs, variable, 100-ps or 3-digit resolution
Arbitrary Waveform Waveform length 8 Sa to 1 MSa (16 MSa with Option 002) in increments of 1 sample
Sample rate 1 μSa/s to 250 MSa/s, 1 μSa/s resolution
Voltage resolution 16 bits
Bandwidth (-3 dB, nom) Filter Off: 40 MHz; "Normal" Filter On: 0.27 × Sample Rate; "Step" Filter On: 0.13 × Sample Rate
Rise and fall time 0.35 / Bandwidth (10 ns min) with Normal or Step filter On
Settling time (typ) < 200 ns to 0.5% of final value
Jitter (typ) Filter Off: < 40 ps rms; Normal or Step filter On: < 5 ps
Waveform Sequencing Segment length 8 Sa to 1 MSa (16 MSa with Option 002) in increments of 1 sample
Sequence length 1 to 512 steps
Segment repeat count 1 to 1×10^6, or infinite
Signal Output Output impedance (nom) 50 Ω
Amplitude range 1 mVpp to 10 Vpp into 50 Ω; 2 mVpp to 20 Vpp into open circuit
Amplitude accuracy (spec) ±1% of setting ±1 mVpp at 1 kHz
Isolation Maximum allowable voltage on isolated connector shells is ±42 Vpk
DC Offset Range ±(5 VDC - Peak AC) into 50 Ω; ±(10 VDC - Peak AC) into open circuit
Resolution 4 digits
Accuracy (spec) ±1% of Offset setting ±0.25% of Amplitude setting ±2 mV
Frequency Accuracy Standard, 1 year, 23°C ± 5°C ±1 ppm of setting ± 15 pHz
Standard, 1 year, 0°C to 55°C ±2 ppm of setting ± 15 pHz
Option 010, 1 year, 0°C to 55°C ±0.1 ppm of setting ± 15 pHz
Computer Interfaces LXI-C (rev 1.3) 10/100Base-T Ethernet (Sockets & VXI-11 protocol)
USB USB 2.0 (USB-TMC488 protocol)
GPIB IEEE-488.1, IEEE-488.2 (Option 400)
Web user interface Remote operation and monitoring
Programming language SCPI-1999, IEEE-488.2; Agilent 33210A / 33220A compatible
Display Graphical 4.3" Color TFT WQVGA (480x272) with LED backlight
Mechanical Size 261.1 mm W × 103.8 mm H × 303.2 mm D (with bumpers); 212.8 mm W × 88.3 mm H × 272.3 mm D (no bumpers); 2U × ½ rack width
Weight (nom) 3.3 kg (7.2 lbs)
Environmental Operating temperature 0°C to 55°C
Storage temperature -40°C to 70°C
Operating humidity 5% to 80% RH, non-condensing
Operating altitude up to 3000 meters
Warm-up time 1 hour
Line Power Voltage 100 V - 240 V 50/60 Hz -5%, +10%; 100 V - 120 V 400 Hz ±10%
Power consumption (typ) < 45 W, < 130 VA
Acoustic noise (nom) SPL 35 dB(A)
Memory Non-volatile File system file space limited to 64 MB (~32 MSa of arbitrary waveform records)
Important: Maximum allowable voltage on the isolated connector shells (channel outputs, Sync, and Mod In) is ±42 Vpk.Important: Unless otherwise stated, all specifications apply with a 50 Ω resistive load and auto range ON.Important: Maximum allowable voltage on isolated connector shells (channel output, Sync, and Mod In) is ±42 Vpk.Important: Add 1/10th of the output amplitude and offset accuracy specification per °C for operation at temperatures beyond 23°C ± 5°C.Important: Counted Burst operation is not allowed for Gaussian Noise.Important: External trigger only for sweep time > 8000 sec.Recommended pairing: the 33522A is the two-channel version of the 33500 Series; the 33521A provides the same architecture in a single-channel configuration for applications that do not require dual-channel coupling, combined, equal, or differential operation.

About this used unit

  • Warranty included on every pre-owned unit
  • Functional verification performed by ValueTronics technicians before shipment
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.