Agilent E1366A Dual 1x4 50 Ω RF Multiplexer (Pre-Owned)

Key Features At A Glance

  • Dual 1x4 multiplexer architecture — two independent banks (Bank 0 and Bank 1) of 1x4 one-wire multiplexers in a single module
  • 50 Ohm characteristic impedance with BNC connectors for RF signal switching applications
  • Signal switching up to 1.3 GHz with insertion loss under 3.0 dB at 1.3 GHz and under 0.3 dB at 10 MHz
  • Tree-switched relay configuration providing high isolation (channel-to-channel crosstalk under -90 dB at 10 MHz)
  • Off-channels terminated to 50 Ohm — termination resistors removable if desired
  • B-size, 1-slot, register-based VXI module (A16, slave only) — C-size compatibility via E1403C adapter
  • Non-latching armature relays with rated load life of 100,000 operations and no-load life of 5,000,000 operations
  • Maximum input ratings of 42 V, 1 A AC/DC, and 24 W DC / 24 VA AC per channel or common
Share on
View full details

The Agilent E1366A is a Dual 1x4 50 Ohm RF Multiplexer in a B-size, 1-slot, register-based VXI form factor. The module is arranged as two independent banks of channels — Bank 0 and Bank 1 — each acting as a 1x4 one-wire multiplexer. Switching consists of connecting a channel to its common terminal, with only one channel in each bank connected to its common at any time. At power-on or reset, all channels are open and connected to their 50 Ohm termination resistors.

The E1366A is positioned as the ideal choice for switching test signals to oscilloscopes, spectrum analyzers, network analyzers, distortion analyzers, and other RF equipment. The multiplexer can easily be used with SCPI commands to scan multiple channels, where each channel is switched to its common one at a time. The tree-switched relay configuration provides high isolation and low VSWR — supporting applications where signal integrity across multiple RF test paths is essential.

ValueTronics International has supported test and measurement professionals since 1992, operating from a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every instrument that passes through our facility is inspected and tested by our in-house technicians before it ships — a meaningful distinction from drop-shippers and pass-through brokers who never physically handle the equipment they sell. For VXI modules like the E1366A, that hands-on verification matters: register-based modules with relay-based switching paths need to be confirmed functional and within specification before they enter a customer's test system.

Brand Heritage

The E1366A originated within Hewlett-Packard's test and measurement division. HP spun out its test and measurement business as Agilent Technologies in 1999, which subsequently transferred its electronic measurement business to Keysight Technologies in 2014. Modules carrying the Agilent brand from this product generation are part of that continuous HP-to-Agilent-to-Keysight lineage.

Product Core & Specifications

Important: Maximum input ratings: 42 V (center or shield-to-center, shield or chassis), 1 A AC/DC per channel or common, 24 W DC or 24 VA AC maximum power per channel or common.Important: C-size mainframe installation requires the E1403C active adapter (sold separately).Important: BNC cables and adapters for connecting to the front-panel BNC connectors are not included; various 50 Ω cables and adapters are available separately from the manufacturer.Important: For AC performance specifications, ZL=ZS=ZO, ≤40 °C, RH ≤95% for C-size and RH ≤65% for B-size.Important: Derate crosstalk specifications by 6 dB if all channels are unterminated.Recommended pairing: for installation in a C-size mainframe, use the Agilent E1403C active adapter as specified in the datasheet.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Used

Manufacturer

Agilent