Skip to content
The economy-class EXA is the fastest way to maximize throughput on the production line. From measurement speed to code compatibility, it makes every millisecond count and helps you reduce your overall cost of test. They can’t predict the future, but Keysight Agilent HP can help you shape it with our future-ready test assets. The X-Series is an evolutionary approach to signal analysis that spans instrumentation, measurements and software. It gives you the flexibility to satisfy your business and technical requirements across multiple products and programs—now and in the future.
Model No
N9010A
Condition
Used
Manufacturer
Agilent
205
Basic VSA-lite
235
Pre-amplifier
333
X-Series analyzer connectivity
3FP
Amplitude correction and limit lines
4FP
TOI and harmonics
503
9 kHz to 3.0 GHz Frequency Range
507
Frequency range , 9 kHz to 7.0 GHz
513
Frequency range , 10 Hz to 13.6 GHz
526
20 Hz to 26.5 GHz
550
Frequency range , 3 Hz to 50 GHz
5FP
ACP 18 Carrier
6FP
TV Trigger and IQ Analyzer
AYA
Vector modulation analysis
B1X
Increase analysis bandwidth from 10/25 to 160 MHz
B25
25MHz Maximum bandwidth
B40
40MHz Maximum bandwidth
BBA
Baseband Analog I/Q
CRP
Arbitrary IF output
DP2
Digital processor with 2 GB capture memory
EA3
Electronic attenuator (Frequency range 20 Hz to 3.6 GHz)
EDP
Enhanced display package
EMC
Basic precompliance EMI features
EP1
Enhanced Phase Noise Performance
EP3
Enhanced phase noise
EP4
Enhanced phase noise performance , CXA
ESC
External source control
FS1
Fast sweep capability
FSA
Mechanical attenuator , 2 dB steps , 0 to 70 dB
LFE
Low Frequency Enabled (allows frequency range to 3 Hz)
LNP
Low noise path
LOT 772664
550 , DP2 , EA3 , EP1 , FS1 , FSA , LFE , LNP , MPB , NFE , NUL , P50 , DFR , RTL N9060A2-7FP , N9068A AFP AND CFP , N9069A AFP
LOT 793953
508 , B25 , B40 , BBA , DP2 , EP2 , FS1 , MPB , NF2 , P08 , PFR , RTL. N9060A 3 to 7 FP. N9060B 2FP. N9064A AFP. N9068A CFP. N9071A CFP. N9073A A to E FP. N9077A BFP. N9079A CFP. N9080B BFP. N9082B AFP
MPB
Microwave preselector bypass
N6060A 2FP
Spectrum Analyzer Measurement Application
N9020A-B25
Analysis bandwidth , 25 MHz
N9060A 2 TO 7 FP
2FP Spectrum Analyzer Measurement , 3FP Amplitude Correction and Limit Lines , 4FP TOI and Harmonics , 5FP ACP 18 Carrier , 6FP TV Trigger and IQ Analyzer Enhancement , 7FP Zero Span , Register , Trace , and Spurious Enhancements
N9060A-2FP
Spectrum Analyzer Measurement Application
N9060A-3FP
Amplitude correction and Limit Lines
N9060A-4FP
TOI and Harmonics
N9060A2-4FP
TOI and Harmonics
N9060A2FP
Spectrum Analyzer Measurement Application
N9060B2FP
Spectrum Analyzer Measurement Application
N9060B2FR
Spectrum Analyzer Measurement Application
N9068A AFP
Phase Noise Feature Enhancements
N9069A AFP
Phase Noise Feature Enhancements
N9073A-1FP
Standard-based , one-button W-CDMA measurements; supports analog baseband analysis with Option BBA (BBIQ inputs)
N9073A-2FP
Adds HSPA measurements; requires 1FP/1TP
N9075A-2FP
Standard-based , one-button Mobile WiMAX measurements; supports analog baseband analysis with Option BBA (BBIQ inputs)
NFE
Noise Floor Extension
NUL
LO/IM nulling , Minimizes the LO feed-thru and intermodulation distortion
P03
Preamplifier , 100 kHz to 3.6 GHz
P08
8.4 GHz Preamplifier
P50
Preamplifier , 50 GHz
PC4
Upgrade to dual core processor with removable solid state drive
PC5
Single core 64-bit performance processor , 4GB RAM , removable SSD
PFR
Precision frequency reference 10 MHz
PLUS
Includes: N9060A 3 TO 7FP , N9068A 2FP , N9069A 1 AND 2FP , N9071A 2 AND 3FP , N9072A 2FP AND 2TP , N9073A 1FP , 1TP , 2 AND 3 FP , A TO DFP , N9075A 2FP , N9076A 1FP , N9077A 2FP , N9079A 1 AND 2FP , N9080A 1FP , N9082A 1FP
PRC
Portable configuration
RTL
Real-time link
T03
9 kHz to 3 GHz Tracking Generator Frequency
UK6
Commercial calibration test data
YAS
Y-axis screen video output