Skip to product information
1 of 1
Used
lab tested

N9000A Agilent Analyzer Used

N9000A Agilent Analyzer Used

Regular price $2,795
Sale price $2,795 Regular price
In Stock
Shipping calculated at checkout.
Options
Calibrations
Request a Quote
Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Additional Features:

Functionality

  • 9 kHz to 3 or 7.5 GHz; internal preamplifier options up to 7.5 GHz
  • Optional built-in tracking generator 3 or 6 GHz
  • 10 MHz (standard), 25 MHz (optional) analysis bandwidth
Share on
View full details

Performance

  • ±0.5 dB absolute amplitude accuracy
  • +17 dBm third order intercept (TOI)
  • -163 dBm displayed average noise level (DANL)
  • -66 dB W-CDMA ACLR dynamic range (with noise correction on)

Measurement Application & Software

  • CXA supports over 25 measurement applications, covering cellular communication, wireless connectivity, digital video, and general purpose.
  • Advanced analysis of up to 70 signal formats, software runs inside the CXA.
  • Agilent's PowerSuite one-button power measurements included as standard

Automation & Communication Interface

  • LXI class C compliant, SCPI, and IVI-COM
  • USB 2.0, 1000 Base-T LAN, GPIB
  • Programming remote language compatibility with ESA and other X-Series
  • Common X-Series user interface / Open Windows® XP operating system

A great low-cost signal analyzer surpasses the basics and covers what's essential. That's the strength of the CXA signal analyzer, the leading low-cost tool for essential signal characterization. Its capabilities provide a foundation for cost-effective testing and seamless integration with the other X-Series models. The CXA is also an excellent teaching tool for RF technology and signal analysis. Get must-have capability with X-Series expandability in the CXA - and master the essentials. The CXA signal analyzer is a member of the X-Series, which is an evolutionary approach to signal analysis that spans instrumentation, measurements, and software. It gives you the flexibility to satisfy your business and technical requirements across multiple products and programs —now and in the future.

Model No

N9000A

Condition

Used

Manufacturer

Agilent

205

Basic VSA-lite

235

Pre-amplifier

333

X-Series analyzer connectivity

3FP

Amplitude correction and limit lines

4FP

TOI and harmonics

503

9 kHz to 3.0 GHz Frequency Range

507

Frequency range , 9 kHz to 7.0 GHz

513

Frequency range , 10 Hz to 13.6 GHz

526

20 Hz to 26.5 GHz

550

Frequency range , 3 Hz to 50 GHz

5FP

ACP 18 Carrier

6FP

TV Trigger and IQ Analyzer

AYA

Vector modulation analysis

B1X

Increase analysis bandwidth from 10/25 to 160 MHz

B25

25MHz Maximum bandwidth

B40

40MHz Maximum bandwidth

BBA

Baseband Analog I/Q

CRP

Arbitrary IF output

DP2

Digital processor with 2 GB capture memory

EA3

Electronic attenuator (Frequency range 20 Hz to 3.6 GHz)

EDP

Enhanced display package

EMC

Basic precompliance EMI features

EP1

Enhanced Phase Noise Performance

EP3

Enhanced phase noise

EP4

Enhanced phase noise performance , CXA

ESC

External source control

FS1

Fast sweep capability

FSA

Mechanical attenuator , 2 dB steps , 0 to 70 dB

LFE

Low Frequency Enabled (allows frequency range to 3 Hz)

LNP

Low noise path

LOT 772664

550 , DP2 , EA3 , EP1 , FS1 , FSA , LFE , LNP , MPB , NFE , NUL , P50 , DFR , RTL N9060A2-7FP , N9068A AFP AND CFP , N9069A AFP

LOT 793953

508 , B25 , B40 , BBA , DP2 , EP2 , FS1 , MPB , NF2 , P08 , PFR , RTL. N9060A 3 to 7 FP. N9060B 2FP. N9064A AFP. N9068A CFP. N9071A CFP. N9073A A to E FP. N9077A BFP. N9079A CFP. N9080B BFP. N9082B AFP

MPB

Microwave preselector bypass

N6060A 2FP

Spectrum Analyzer Measurement Application

N9020A-B25

Analysis bandwidth , 25 MHz

N9060A 2 TO 7 FP

2FP Spectrum Analyzer Measurement , 3FP Amplitude Correction and Limit Lines , 4FP TOI and Harmonics , 5FP ACP 18 Carrier , 6FP TV Trigger and IQ Analyzer Enhancement , 7FP Zero Span , Register , Trace , and Spurious Enhancements

N9060A-2FP

Spectrum Analyzer Measurement Application

N9060A-3FP

Amplitude correction and Limit Lines

N9060A-4FP

TOI and Harmonics

N9060A2-4FP

TOI and Harmonics

N9060A2FP

Spectrum Analyzer Measurement Application

N9060B2FP

Spectrum Analyzer Measurement Application

N9060B2FR

Spectrum Analyzer Measurement Application

N9068A AFP

Phase Noise Feature Enhancements

N9069A AFP

Phase Noise Feature Enhancements

N9073A-1FP

Standard-based , one-button W-CDMA measurements; supports analog baseband analysis with Option BBA (BBIQ inputs)

N9073A-2FP

Adds HSPA measurements; requires 1FP/1TP

N9075A-2FP

Standard-based , one-button Mobile WiMAX measurements; supports analog baseband analysis with Option BBA (BBIQ inputs)

NFE

Noise Floor Extension

NUL

LO/IM nulling , Minimizes the LO feed-thru and intermodulation distortion

P03

Preamplifier , 100 kHz to 3.6 GHz

P08

8.4 GHz Preamplifier

P50

Preamplifier , 50 GHz

PC4

Upgrade to dual core processor with removable solid state drive

PC5

Single core 64-bit performance processor , 4GB RAM , removable SSD

PFR

Precision frequency reference 10 MHz

PLUS

Includes: N9060A 3 TO 7FP , N9068A 2FP , N9069A 1 AND 2FP , N9071A 2 AND 3FP , N9072A 2FP AND 2TP , N9073A 1FP , 1TP , 2 AND 3 FP , A TO DFP , N9075A 2FP , N9076A 1FP , N9077A 2FP , N9079A 1 AND 2FP , N9080A 1FP , N9082A 1FP

PRC

Portable configuration

RTL

Real-time link

T03

9 kHz to 3 GHz Tracking Generator Frequency

UK6

Commercial calibration test data

YAS