Key Features At A Glance

  • 100 kHz to 7 GHz frequency range, tunable down to 9 kHz (AC coupled)
  • Field-ready handheld operating from -10 to +50 °C; 3.2 kg with a 6.5 in TFT color display
  • Displayed average noise level to -142 dBm with preamp off (specified measurement conditions apply)
  • Resolution bandwidth from 10 Hz to 3 MHz in a 1-3-10 sequence
  • LAN (RJ-45, 10Base-T), USB host, and USB device interfaces standard
  • Up to 4 hours of battery operating time on a fully charged battery
  • Optional tracking generator, RF preamplifier, cable & antenna test, modulation analysis, and GPS
  • Optional task planner automates test setup and reporting, reducing setup time by 95%
View full details

The Agilent N9342C is a handheld spectrum analyzer (HSA) covering a frequency range of 100 kHz to 7 GHz, tunable down to 9 kHz, on an AC-coupled, 50 Ω Type-N input. Built for field use, it pairs benchtop measurement performance with a rugged, portable form factor: a 6.5 in (170 mm) TFT color display at 640 × 480 resolution, a weight of 3.2 kg, and battery operation, so the instrument can be carried into the environments where signals actually live.

Designed to make field measurements easier, the N9342C operates across a -10 to +50 °C temperature range and runs up to four hours on a fully charged battery, suiting it to routine field testing where bench instruments cannot go. Through its option set it extends into cable and antenna test, channel scanning, AM/FM and ASK/FSK modulation analysis, time-gated spectrum analysis, and high-accuracy power measurement, letting a single handheld cover a broad span of field tasks.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned instrument is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer, so buyers get the right instrument in the condition they expect, backed by people who know the equipment.

Brand Heritage

The Agilent name traces to Hewlett-Packard, whose test and measurement business was spun off as Agilent Technologies in 1999. Agilent's electronic measurement division was subsequently established as Keysight Technologies in 2014.

Product Core & Specifications

Specification Value
Frequency
Frequency range 100 kHz to 7 GHz (tunable to 9 kHz), AC coupled
Internal 10 MHz frequency reference - aging rate ± 1 ppm/year
Internal 10 MHz frequency reference - temperature stability ± 1 ppm (referenced to frequency reading at 25 °C, temperature varied at max. 2 °C per minute)
Frequency readout marker resolution (frequency span)/(sweep points - 1)
Frequency readout uncertainty ± (frequency indication × frequency reference uncertainty + 1% × span + 20% × resolution bandwidth + marker resolution + 1 Hz)
Marker frequency counter - resolution 1 Hz
Marker frequency counter - accuracy ± (marker frequency × frequency reference uncertainty + counter resolution)
Frequency span - range 0 Hz (zero span), 100 Hz to 7 GHz
Frequency span - resolution 1 Hz
Frequency span - accuracy ± (0.22% × span + span/(sweep points - 1))
SSB Phase Noise (Nominal, center frequency 500 MHz, 20 to 30 °C)
30 kHz offset < -86 dBc/Hz, typical -89 dBc/Hz
100 kHz offset < -97 dBc/Hz, typical -99 dBc/Hz
1 MHz offset < -115 dBc/Hz, typical -119 dBc/Hz
Resolution Bandwidth (RBW)
-3 dB bandwidth 10 Hz to 3 MHz (1-3-10 sequence)
Accuracy ± 5%, RBW = 10 Hz to 1 MHz; ± 10%, RBW = 3 MHz (nominal)
Resolution filter shape factor < 5:1 (nominal; 60 dB/3 dB bandwidth ratio; digital, Gaussian-like)
Video Bandwidth (VBW)
-3 dB bandwidth 1 Hz to 3 MHz (1-3-10 sequence)
Accuracy ± 10%, VBW = 1 Hz to 1 MHz (nominal)
Amplitude
Measurement range (100 kHz to 2 MHz) Displayed average noise level (DANL) to +10 dBm (preamp off)
Measurement range (2 MHz to 7 GHz) Displayed average noise level (DANL) to +20 dBm (preamp off)
Input attenuator range 0 to 50 dB, in 1 dB steps
Maximum safe input - average continuous power +33 dBm, 3 minutes maximum (input attenuator setting ≥ 20 dB, 2 MHz to 7 GHz)
Maximum safe input - DC voltage ± 50 VDC maximum
Displayed Average Noise Level (DANL), Preamp Off
100 kHz to 1 MHz -108 dBm, typical -127 dBm
1 to 10 MHz -128 dBm, typical -146 dBm
10 to 500 MHz -142 dBm, typical -146 dBm
500 MHz to 2.5 GHz -141 dBm, typical -145 dBm
2.5 to 4 GHz -140 dBm, typical -144 dBm
4 to 6 GHz -138 dBm, typical -142 dBm
6 to 7 GHz -136 dBm, typical -140 dBm
Displayed Average Noise Level (DANL), Preamp On
100 kHz to 1 MHz -131 dBm, typical -150 dBm
1 to 10 MHz -148 dBm, typical -163 dBm
10 to 500 MHz -161 dBm, typical -164 dBm
500 MHz to 2.5 GHz -159 dBm, typical -162 dBm
2.5 to 4 GHz -158 dBm, typical -161 dBm
4 to 6 GHz -155 dBm, typical -158 dBm
6 to 7 GHz -150 dBm, typical -154 dBm
Amplitude Display and Detection
Level display range - log scale 10 to 100 dB, 10 divisions displayed, 1, 2, 5, 10 dB/division
Level display range - linear scale 0 to 100%, 10 divisions displayed
Scale units dBm, dBmV, dBμV, W, V, dBmV EMF, dBμV EMF, V EMF
Sweep (trace) points 461
Marker level readout resolution - log scale 0.01 dB
Marker level readout resolution - linear scale ≤ 1% of signal level (nominal)
Detectors Normal, positive peak, sample, negative peak, average (video, RMS, voltage)
Number of traces 4
Trace functions Clear/write, maximum hold, minimum hold, average
Level measurement error ± 1.5 dB (excluding input VSWR mismatch; 20 to 30 °C, 30 to 70% RH, peak detector, preamp off, input signal -50 to 0 dBm, 95th percentile, Swp Time Rule set to Accuracy; adds ± 0.3 dB when Swp Time Rule set to Speed)
Reference Level
Setting range -100 to 30 dBm (steps of 1 dB)
Setting resolution - log scale 0.01 dB
Setting resolution - linear scale Same as log (2.236 µV to 7.07 V)
Accuracy 0
RF Input VSWR (at tuned frequency)
10 MHz to 3 GHz < 1.5:1 (nominal, 10 or 20 dB attenuation)
3 to 7 GHz < 2.0:1
Spurious Response
Second harmonic distortion < -65 dBc, 50 MHz to 3 GHz; < -70 dBc, 3 to 7 GHz (mixer signal level at -30 dBm, input attenuation 0 dB, preamp off, 20 to 30 °C)
Third order intermodulation distortion (third order intercept) +7 dBm, 50 to 300 MHz; +10 dBm, 300 MHz to 7 GHz
Input related spurious < -75 dBc (-30 dBm signal at input mixer)
Inherent residual response < -90 dBm, typical -98 dBm (input terminated and 0 dB RF attenuation, preamplifier off)
Sweep
Sweep time range 2 ms to 1000 s (span ≥ 100 Hz); 600 ns to 200 s (zero span)
Sweep mode Continuous, single
Sweep time rule Accuracy, speed
Trigger source Free run, video, external, RF burst
Trigger slope Selectable positive or negative edge
Trigger delay ± 12 ms to ± 12 s (nominal, zero span)
Front Panel Input/Output
RF input - connector and impedance Type-N female, 50 Ω (nominal)
10 MHz reference/external trigger input - reference input frequency 10 MHz
10 MHz reference/external trigger input - reference input amplitude 0 to +10 dBm
External trigger voltage 5 V TTL level (nominal)
10 MHz reference/external trigger connector BNC female, 50 Ω (nominal)
Probe power - voltage/current +15 Vdc, ± 7% at 0 to 150 mA (nominal); -12.6 Vdc, ± 10% at 0 to 150 mA (nominal)
Connectivity
USB host USB Type-A female, compatible with USB 2.0 full speed
USB device USB Type-mini AB female, compatible with USB 2.0 full speed
LAN RJ-45, 10 Base-T
General - Display
Resolution 640 pixels x 480 pixels
Size and type 170 mm (6.5 in) TFT color display
Languages (on-screen GUI) English, Simplified Chinese, Traditional Chinese, French, German, Italian, Japanese, Korean, Russian, Spanish, Portuguese
General - Power Requirements and Calibration
Adaptor voltage 100 to 240 V AC, 50 to 60 Hz, auto-ranging; 15 V DC, 5.3 A, 80 W max
Power consumption 15 W (typical)
Battery operating time (fully charged battery) 4 hours (tracking generator off, preamplifier on); 3 hours (tracking generator on, preamplifier on)
Important: Maximum safe input level: +33 dBm average continuous power (3 minutes maximum, input attenuator setting ≥ 20 dB, 2 MHz to 7 GHz) and ±50 VDC maximum.
Important: High accuracy power measurement (Option PWM) requires an Agilent U2000 Series USB power sensor; frequency range (9 kHz to 24 GHz) and dynamic range (-60 to +44 dBm) are sensor dependent.
Important: Option GPS uses a built-in GPS antenna; an external GPS antenna (N934xC-GPA) is offered as an optional accessory and is connected via the SMA-F external GPS antenna connector.
Important: Specifications apply to temperatures ranging from -10 to 50 °C unless otherwise noted, and require the analyzer to be within its calibration cycle and turned on at least 30 minutes.
Recommended pairing: the optional high-accuracy power measurement capability supports the Agilent U2000 Series USB power sensor for power measurements from 9 kHz to 24 GHz.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Pre-Owned

Manufacturer

Agilent

Spec_ana_freq

100 kHz to 7 GHz

506

6 GHz frequency range

P06

Preamp

TG6

Tracking Generator