The Agilent N5242A is a 2-port or 4-port PNA-X vector network analyzer covering 10 MHz to 26.5 GHz, with a companion N5241A model covering 10 MHz to 13.5 GHz. The PNA-X platform is built around a configurable test set architecture: the base 2-port (Option 200) and 4-port (Option 400) units provide standard S-parameter measurement capability with front-panel access loops, while extended-power options (219, 419) add source and receiver attenuators along with bias-tees, and the 224 and 423 options add an internal second source, signal combiner, and mechanical switches for advanced application work. Option 029 adds dedicated hardware and firmware for high-accuracy noise figure measurements at Port 2.
The N5242A is used for vector network analysis applications that require S-parameter measurement, including reflection and transmission measurements on RF and microwave components, amplifier characterization, filter and passive component test, and — with Option 029 — noise figure measurement up to 26.5 GHz. The internal second-source options (224/423) and combiner support measurements that require two simultaneous stimulus signals through a single test port in combine mode. The instrument supports both filtered-mode operation (signal path through filters to minimize harmonics below 3.2 GHz) and high-power mode (signal bypasses the filters to maximize output power).
ValueTronics has supplied new and used test and measurement equipment from its 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois since 1992. Every {{CONDITION}} N5242A PNA-X analyzer that ships from our facility has been received, inventoried, and handled by our own team — not drop-shipped through a broker pipeline. This direct stewardship of the inventory is how we maintain accountability for what we sell, and why we are able to commit to specific instrument identification, option-string verification, and accessory completeness before a quote leaves the building.
Hewlett-Packard's test and measurement division was spun out as Agilent Technologies in 1999. In 2014, Agilent split its electronic measurement business into a separate company, Keysight Technologies, which is the current manufacturer for the PNA-X product line and its successors. Instruments originally branded Agilent — including the N5241A and N5242A covered by this datasheet — are part of the same engineering and product lineage that continues under Keysight today.
The PNA-X family covered by this datasheet consists of two analyzer models — the N5241A and the N5242A — that share a common test set architecture but differ in their upper frequency limit. Both models are available in 2-port and 4-port physical configurations, and both accept the same set of test set options (200, 219, 224, 400, 419, 423) and the same Option 029 for noise figure measurement. The choice between the two models is driven primarily by the highest frequency the application requires.
Beyond the base model selection, configuration is defined by the test set options that determine power range, attenuator presence, bias-tee inclusion, second-source presence, and combiner availability. The 2-port options (200, 219, 224) and 4-port options (400, 419, 423) are functionally parallel — the 4-port options add the additional two test ports and supporting receivers but otherwise mirror their 2-port counterparts in capability.
Each pre-owned N5242A model below is its own dedicated product page with condition-matched pricing and option-specific availability. Because the PNA-X test set options materially change what the instrument can do — extended power range, internal second source, noise figure capability — confirming the exact option string (e.g., 200, 219, 224, 400, 419, 423, with or without 029) is the first qualification step for any quote on a unit in this family.
The N5242A covers the full 10 MHz to 26.5 GHz range published in this datasheet, providing measurement capability through K-band (18–26.5 GHz). At the upper end of the band, specifications change: maximum leveled power on Ports 1/3 from 24 GHz to 26.5 GHz is 5 dBm (Options 200/400), and the test port noise floor specification is -107 dBm at 10 Hz IF bandwidth, compared to -114 dBm from 500 MHz through 20 GHz.
The base test set options (200, 400) provide the standard measurement capability with the highest maximum leveled output power on the 'A' ports (Ports 1, 3) — 13 dBm in high-power mode across most of the band. The 219/419 options add source and receiver step attenuators plus bias-tees, which give a wider power sweep range and DC bias capability through the test port at the cost of a small reduction in maximum leveled power. The 224/423 options add an internal second source, combiner, and mechanical switches, enabling combine-mode measurements where Source 1 and Source 2 are summed at Port 1.
Option 029 is a separate add-on that requires one of options 219, 224, 419, or 423 and adds the hardware and firmware needed for high-accuracy noise figure measurement at Port 2. With Option 029 engaged in noise mode, the Port 2 RF damage level reduces from >+30 dBm to >+27 dBm, and the maximum leveled power available at the test ports is reduced by approximately 1 dB in most bands compared to the same option without 029. The comparison table that follows shows the option-by-option differences in maximum leveled power, system dynamic range, and the key uncorrected performance parameters.
| Model | Frequency Range | Test Ports | Max Test Port Power |
|---|---|---|---|
| N5242A | 10 MHz to 26.5 GHz | 2-Port or 4-Port (configurable) | +5 dBm (typical, Filtered Mode, 24 to 26.5 GHz) |
| N5241A | 10 MHz to 13.5 GHz | 2-Port or 4-Port (configurable) | +13 dBm (typical, Filtered Mode, 3.2 to 13.5 GHz) |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Frequency | |
| Frequency Range | 10 MHz to 26.5 GHz |
| Frequency Resolution | 1 Hz |
| Frequency Accuracy | +/- 1 ppm |
| Frequency Stability | +/-0.05 ppm, -10° to 70° C; +/-0.1 ppm/yr maximum (typical) |
| Test Port Output Power (Specification, Filtered Mode, Options 200/400) | |
| 10 MHz to 50 MHz | 8 dBm (Ports 1, 3); 13 dBm (Ports 2, 4) |
| 50 MHz to 500 MHz | 10 dBm (Ports 1, 3); 13 dBm (Ports 2, 4) |
| 500 MHz to 3.2 GHz | 10 dBm (Ports 1, 3); 13 dBm (Ports 2, 4) |
| 3.2 GHz to 10 GHz | 13 dBm (all ports) |
| 10 GHz to 13.5 GHz | 13 dBm (all ports) |
| 13.5 GHz to 16 GHz | 13 dBm (all ports) |
| 16 GHz to 20 GHz | 13 dBm (Ports 1, 3); 10 dBm (Ports 2, 4) |
| 20 GHz to 24 GHz | 12 dBm (Ports 1, 3); 7 dBm (Ports 2, 4) |
| 24 GHz to 26.5 GHz | 5 dBm (Ports 1, 3); 2 dBm (Ports 2, 4) |
| Nominal (Preset) Power | 0 dBm (Options 200, 400); -5 dBm (Options 219, 224, 419, 423) |
| Power Resolution | 0.01 dB |
| Test Port Input | |
| Noise Floor (10 Hz IFBW) | -114 dBm spec / -117 dBm typ (500 MHz to 20 GHz); -110 dBm spec / -115 dBm typ (20-24 GHz); -107 dBm spec / -113 dBm typ (24-26.5 GHz) |
| 0.1 dB Compression at Test Port | 13 dBm (500 MHz to 16 GHz); 12 dBm (16-20 GHz); 10.5 dBm (20-24 GHz); 10 dBm (24-26.5 GHz) |
| Damage Input Level (Test Ports 1-4) | > +30 dBm RF; 40 V DC |
| System Dynamic Range (Specification, Options 200/400) | |
| 3.2 GHz to 13.5 GHz | 127 dB |
| 13.5 GHz to 20 GHz | 127 dB |
| 20 GHz to 24 GHz | 122 dB |
| 24 GHz to 26.5 GHz | 112 dB |
| IF / Receiver | |
| System IF Bandwidth Range | 1 Hz to 15 MHz, nominal (7/10/15 MHz IFBWs available only with FW A.09.42+ and DSP v5) |
| Front Panel | |
| Test Port Connectors | 3.5 mm (male), 50 ohm nominal |
| Display | 26.3 cm (10.4 in) diagonal color active matrix LCD, 1024 x 768 |
| USB 2.0 Ports (Front) | 4 (USB Type-A female) |
| Rear Panel | |
| 10 MHz Reference In | BNC female, -15 dBm to +20 dBm, 200 Ω nominal |
| 10 MHz Reference Out | BNC female, +10 dBm ±4 dB into 50 Ω, sine wave |
| GPIB | Two ports (controller and talker/listener), IEEE-488 compatible |
| LAN | 10/100BaseT Ethernet |
| LXI | Class C (FW A.08.20+) |
| CPU | Intel 2.0 GHz Core i7 (some instruments may vary) |
| Power | |
| Line Frequency/Voltage | 50/60/400 Hz for 100-120 VAC; 50/60 Hz for 220-240 VAC (auto-switching) |
| Max Power | 450 watts |
| Dimensions and Weight | |
| Height (with bottom feet) | 279.1 mm (11.0 in) |
| Width (with handles and rack-mount flanges) | 482.9 mm (19.0 in) |
| Depth (with hardware and handles) | 578.0 mm (22.7 in) |
| Net Weight (2-port) | 27 kg (60 lb) |
| Net Weight (4-port) | 37 kg (82 lb) |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Agilent
Condition
Used
Manufacturer
Agilent
Frequency
26.5 GHz
7
Automatic Fixture Removal
8
Pulsed-RF Measurements
10
Time-domain measurements
15
Dynamic Uncertainty for S-Parameter Measurements
20
Add IF inputs
21
Add pulse modulator to internal first source
22
Add pulse modulator to internal second source
25
Internal pulse generators , Add 4
28
Noise figure measurements using standard receivers
29
Fully-corrected noise-figure measurements to 13.5 GHz
80
Frequency offset measurements
82
Scalar calibrated converter measurements
83
Vector and scalar calibrated converter measurements
84
Add embedded LO measurements
86
Gain compression measurements
87
Intermodulation distortion measurements
88
Source phase control
89
Differential and I/Q devices application
90
Spectrum Analyzer
118
Fast CW mode
1CM
Rack mount kit for installation without handles
1CP
Rack mount kit for installation with handles
200
2 ports , single source
201
2-ports , single source , with configurable test set
219
Add extended power range and bias-tees to 2 port analyzer
224
Add internal second source , combiner and mechanical switches to 2-port analyzer
301
Application for use with standard CalPods
302
Application for use with temperature-characterized CalPods
400
4 ports , dual source
417
4-ports , dual source , with extended power range
419
Add extended power range and bias-tees to 4 port analyzer
423
Add internal combiner and mechanical switches to 4-port analyzer
460
Integrated true-mode stimulus application
510
Nonlinear component characterization , full frequency range
514
Nonlinear X-Parameters
518
Nonlinear Pulse Envelope Domain
520
Arbitrary load impedance X-parameters
551
N-port calibrated measurements
WIN7
Windows 7
Request A Quote