RIGOL DSA815-TG 9 kHz to 1.5 GHz Spectrum Analyzer with Tracking Generator (Factory Installed)

Key Features At A Glance

  • Frequency coverage spanning 9 kHz up to 7.5 GHz across the DSA815, DSA832, and DSA875 models
  • All-digital IF technology lowers displayed average noise level and improves amplitude accuracy and sweep speed
  • Resolution bandwidth from 10 Hz to 1 MHz across the series in a 1-3-10 sequence
  • LAN (LXI) plus USB Host and USB Device standard; GPIB (IEEE 488.2) available via USB-GPIB option for ATE
  • 8-inch WVGA (800x480) TFT display with three traces plus a math trace
  • Optional tracking generator (to 7.5 GHz) and preamplifier extend reflection and low-level measurements
  • Optional kits add advanced measurements, EMI filter & quasi-peak detection, and VSWR measurement
  • Maximum input 50 V DC and +20 dBm CW RF at 30 dB attenuation; +30 dBm maximum damage level
View full details

The DSA800 is a series of spectrum analyzers from RIGOL Technologies built on an all-digital IF design. The series comprises three models - the DSA815, DSA832, and DSA875 - covering frequency ranges from 9 kHz up to 1.5 GHz, 3.2 GHz, and 7.5 GHz respectively, each with 1 Hz frequency resolution and an 8-inch WVGA (800x480) display in a compact, lightweight enclosure.

A spectrum analyzer displays the amplitude of input signals across a span of frequencies, letting an engineer characterize a signal's frequency content, power, and spectral purity. Across the DSA800 series the available measurement functions - supplied as an optional advanced measurement kit - include harmonic distortion, third-order intercept (TOI), channel power, adjacent channel power, occupied bandwidth, emission bandwidth, time-domain power, and carrier-to-noise ratio. EMI pre-compliance work is supported through an optional EMI filter and quasi-peak detector kit with pass/fail limits, and an optional VSWR measurement kit supports reflection measurements.

ValueTronics stocks and holds the DSA800 series in our own 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.

Compare Other Models in This Series

The DSA800 series groups three spectrum analyzers that share the same all-digital IF platform, 8-inch WVGA display, and connectivity set while differing chiefly in frequency coverage: the DSA815 reaches 1.5 GHz, the DSA832 reaches 3.2 GHz, and the DSA875 reaches 7.5 GHz, each starting at 9 kHz.

Beyond frequency range, the DSA832 and DSA875 extend the resolution bandwidth down to 10 Hz and tighten the phase-noise and level-measurement specifications, so the choice among models is driven by the span and resolution a given measurement requires.

Each model below links to its own dedicated product page with condition-matched pricing for the new unit you select, so you can compare the DSA815, DSA832, and DSA875 individually and choose the frequency tier and condition that fit your application and budget.

The clearest difference is the upper frequency limit - 1.5 GHz on the DSA815, 3.2 GHz on the DSA832, and 7.5 GHz on the DSA875 - with the comparison table below listing each model's coverage alongside its bandwidth and amplitude specifications.

The DSA815 provides a resolution bandwidth from 100 Hz to 1 MHz and an SSB phase noise specification below -80 dBc/Hz at 10 kHz offset, and ships with a preamplifier as standard. The DSA832 and DSA875 provide a resolution bandwidth from 10 Hz to 1 MHz and phase noise below -98 dBc/Hz at 10 kHz offset, with the preamplifier offered as an option; consult each model's row in the table for its specific values.

Model Frequency Range Min RBW Phase Noise @10 kHz Offset
DSA815-TG 9 kHz to 1.5 GHz 100 Hz <-80 dBc/Hz
DSA815 9 kHz to 1.5 GHz 100 Hz <-80 dBc/Hz
DSA832 9 kHz to 3.2 GHz 10 Hz <-98 dBc/Hz
DSA875 9 kHz to 7.5 GHz 10 Hz <-98 dBc/Hz

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Quick guide (hard copy)
  • CD-ROM (user's guide, programming guide)
  • Power cable

Product Core & Specifications

Specification Value
Frequency
Frequency range DSA815: 9 kHz to 1.5 GHz; DSA832: 9 kHz to 3.2 GHz; DSA875: 9 kHz to 7.5 GHz
Frequency resolution 1 Hz
Internal Reference Frequency
Reference frequency 10 MHz
Accuracy ± [(time since last adjustment × aging rate) + temperature stability + calibration accuracy]
Initial calibration accuracy <1 ppm
Temperature stability (0℃ to 50℃, reference to 25℃) DSA815: <2 ppm; DSA832/DSA875: <0.5 ppm
Aging rate DSA815: <2 ppm/year; DSA832/DSA875: <1 ppm/year
Frequency Readout Accuracy
Marker resolution span/(number of sweep points - 1)
Marker uncertainty ± (frequency indication × frequency reference uncertainty + 1% × span + 10% × resolution bandwidth + marker resolution)
Frequency Counter
Resolution 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz
Uncertainty ± (frequency indication × reference frequency accuracy + counter resolution)
Frequency Span
Range 0 Hz, 100 Hz to maximum frequency of instrument
Uncertainty ±span/(number of sweep points - 1)
SSB Phase Noise (20℃ to 30℃, fc = 1 GHz)
Carrier offset 10 kHz DSA815: <-80 dBc/Hz; DSA832/DSA875: <-98 dBc/Hz
Carrier offset 100 kHz <-100 dBc/Hz (typ.)
Residual FM (20℃ to 30℃, RBW = VBW = 1 kHz)
Residual FM DSA815: <50 Hz (nom.); DSA832/DSA875: <20 Hz (nom.)
Bandwidths (Auto SWT set to Accy)
Resolution bandwidth (-3 dB) DSA815: 100 Hz to 1 MHz, in 1-3-10 sequence; DSA832/DSA875: 10 Hz to 1 MHz, in 1-3-10 sequence
RBW uncertainty <5% (nom.)
Resolution filter shape factor (60 dB : 3 dB) <5 (nom.)
Video bandwidth (-3 dB) 1 Hz to 3 MHz, in 1-3-10 sequence
Resolution bandwidth (-6 dB) (EMI-DSA800 option) 200 Hz, 9 kHz, 120 kHz
Amplitude — Measurement Range
Range (fc ≥ 10 MHz) DANL to +20 dBm
Maximum input level — DC voltage 50 V
Maximum input level — CW RF power (attenuation = 30 dB) +20 dBm (100 mW)
Max. damage level +30 dBm (1 W)
Displayed Average Noise Level (DANL) — DSA815 (attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average ≥ 50, tracking generator off, 20℃ to 30℃, input impedance = 50 Ω)
PA off, 100 kHz to 1 MHz <-90 dBm, <-110 dBm (typ.)
PA off, 1 MHz to 1.5 GHz <-110 dBm + 6 × (f/1GHz) dB, <-115 dBm (typ.)
PA on, 100 kHz to 1 MHz <-110 dBm, <-130 dBm (typ.)
PA on, 1 MHz to 1.5 GHz <-130 dBm + 6 × (f/1GHz) dB, <-135 dBm (typ.)
Displayed Average Noise Level (DANL) — DSA832 / DSA875 (attenuation = 0 dB, RBW = VBW = 10 Hz, sample detector, trace average ≥ 50, tracking generator off, 20℃ to 30℃, input impedance = 50 Ω)
PA off, 9 kHz to 100 kHz <-110 dBm (typ.)
PA off, 100 kHz to 5 MHz <-125 dBm, <-128 dBm (typ.)
PA off, 5 MHz to 3.2 GHz <-130 dBm, <-134 dBm (typ.)
PA off, 3.2 GHz to 6 GHz (DSA875) <-126 dBm, <-130 dBm (typ.)
PA off, 6 GHz to 7.5 GHz (DSA875) <-121 dBm, <-125 dBm (typ.)
PA on, 100 kHz to 1 MHz <-142 dBm (typ.)
PA on, 1 MHz to 5 MHz <-142 dBm, <-145 dBm (typ.)
PA on, 5 MHz to 3.2 GHz <-147 dBm, <-151 dBm (typ.)
PA on, 3.2 GHz to 6 GHz (DSA875) <-143 dBm, <-147 dBm (typ.)
PA on, 6 GHz to 7.5 GHz (DSA875) <-138 dBm, <-142 dBm (typ.)
Displayed Average Noise Level (DANL), Normalized to 1 Hz (attenuation = 0 dB, sample detector, trace average ≥ 50, tracking generator off, normalized to 1 Hz, 20℃ to 30℃, input impedance = 50 Ω)
PA off, 9 kHz to 100 kHz (DSA832/DSA875) <-120 dBm (typ.)
PA off, 100 kHz to 1 MHz DSA815: <-110 dBm, <-130 dBm (typ.); DSA832/DSA875: <-135 dBm, <-138 dBm (typ.)
PA off, 1 MHz to 5 MHz (DSA815) <-130 dBm + 6 × (f/1GHz) dB, <-135 dBm (typ.)
PA off, 5 MHz to 1.5 GHz (DSA815) / 5 MHz to 3.2 GHz (DSA832/DSA875) <-140 dBm, <-144 dBm (typ.)
PA off, 3.2 GHz to 6 GHz (DSA875) <-136 dBm, <-140 dBm (typ.)
PA off, 6 GHz to 7.5 GHz (DSA875) <-131 dBm, <-135 dBm (typ.)
PA on, 100 kHz to 1 MHz DSA815: <-130 dBm, <-150 dBm (typ.); DSA832/DSA875: <-152 dBm (typ.)
PA on, 1 MHz to 5 MHz DSA815: <-150 dBm + 6 × (f/1GHz) dB, <-155 dBm (typ.); DSA832/DSA875: <-152 dBm, <-155 dBm (typ.)
PA on, 5 MHz to 1.5 GHz (DSA815) / 5 MHz to 3.2 GHz (DSA832/DSA875) <-157 dBm, <-161 dBm (typ.)
PA on, 3.2 GHz to 6 GHz (DSA875) <-153 dBm, <-157 dBm (typ.)
PA on, 6 GHz to 7.5 GHz (DSA875) <-148 dBm, <-152 dBm (typ.)
Level Display
Logarithmic level axis 1 dB to 200 dB
Linear level axis 0 to reference level
Number of display points 601
Number of traces 3 + math trace
Trace detectors normal, positive-peak, negative-peak, sample, RMS, voltage average; quasi-peak (with EMI-DSA800 option)
Trace functions clear write, max hold, min hold, average, view, blank
Units of level axis dBm, dBmV, dBμV, nV, μV, mV, V, nW, μW, mW, W
Frequency Response (relative to 50 MHz, 20℃ to 30℃)
PA off, 100 kHz to 1.5 GHz (fc ≥ 100 kHz, attenuation = 10 dB) DSA815: <0.7 dB; DSA832/DSA875: <0.5 dB, <0.3 dB (typ.)
PA off, 1.5 GHz to 3.2 GHz DSA832/DSA875: <0.5 dB, <0.3 dB (typ.)
PA off, 3.2 GHz to 7.5 GHz (DSA875) <0.7 dB, <0.3 dB (typ.)
PA on, 100 kHz to 1.5 GHz (fc ≥ 1 MHz, attenuation = 10 dB) DSA815: <1.0 dB; DSA832/DSA875: <0.7 dB, <0.3 dB (typ.)
Important: Maximum input level: 50 V DC and +20 dBm CW RF at 30 dB attenuation; maximum damage level +30 dBm (1 W).
Important: Specifications are valid only when the instrument is within its calibration period, has been stored for at least two hours at 0 ℃ to 50 ℃, and has been warmed up for 40 minutes. Unless otherwise noted, the specifications include the measurement uncertainty.
Important: Mass memory uses an internal flash disk; a USB storage device for external mass memory is not supplied.
Important: RF cables, adaptors, attenuators, antennas, and VSWR bridges are optional accessories. The standard delivery includes only the quick guide, CD-ROM (user's guide and programming guide), and power cable — connection accessories to a device under test must be ordered separately (see Optional accessories / Ordering Information).
Recommended pairing: add a RIGOL VSWR bridge (VB1020, VB1032, VB1040, or VB1080) with the optional VSWR measurement kit (VSWR-DSA800) for reflection and VSWR measurements.

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

RIGOL

Condition

Factory New

Manufacturer

RIGOL

Spec_ana_freq

1.5 GHz

AMK

Advanced measurement kit

EMI

EMI Filter & Quasi-Peak Detector Kit

NFP-3

Near Field Probe Kit

PREAMP

Preampliier (PA)

S1210

S1210 EMI Pre-compliance

SSC

Real Time signal capture option for the spectrum analyzer. Enables 1.5 MHz of real time capture for signals like FSK. Works on the DSA700 series and the DSA815 or DSA815-TG

ULTRA

Ultra Spectrum Software for controlling and analyzing data from RIGOL spectrum analyzers

VSWR

VSWR Measurement License Only (DSA800s with TG Only)