Key Features At A Glance

  • Frequency range 100 kHz to 3 GHz, tunable to 9 kHz with optional low-frequency enhancement (Option XDM or IBC)
  • DANL of -124 dBm (30 Hz RBW, 10 MHz-1.5 GHz), improving to -144 dBm with the optional 20 dB preamplifier
  • Narrowest-in-class 30 Hz resolution bandwidth with resolution filter shape factor < 5:1
  • SSB phase noise < -87 dBc/Hz at 30 kHz offset; amplitude accuracy +/- 1.5 dB
  • Fast sweep time of 10 ms to 1000 s, and under 120 ms at full span
  • USB and LAN connectivity with SCPI remote control for ATE integration and PC data transfer
  • 6.5-inch 640x480 TFT display, back-lit keys, 4-hour battery, MIL-PRF 28800F Class 2 compliance
  • Standard spectrogram, spectrum emission mask, and one-button OBW, channel power and ACPR measurements
View full details

The Agilent N9340B is a handheld spectrum analyzer covering 100 kHz to 3 GHz, tunable down to 9 kHz, built for field testing. It is designed to provide a reliable, accurate and detailed picture of the communication spectrum for users handling military communications, wireless service provision and spectrum management, with the goal of avoiding impaired communication.

The N9340B addresses several field-test applications. In aerospace and defence it supports radio and radar test, interference analysis and on-site repair; wireless service providers use it for interference analysis and on-site repair; TV and broadcasting users apply it to interference analysis and channel power checks; and spectrum management authorities use it for spectrum monitoring. A central task is identifying interfering signals, which often arise from illegal transmissions and may impair services for authorized users.

ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, giving buyers direct access to instruments we keep on hand. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

Hewlett-Packard spun off its test and measurement business as Agilent Technologies in 1999. In 2014, Agilent's electronic measurement division was established as Keysight Technologies.

Accessories Supplied

  • Multi-language Quick Start Tutorial
  • CD-ROM of the manual
  • Soft carrying case

Product Core & Specifications

Important: Options XDM (low-frequency enhancement with xDSL measurement) and IBC (IBOC AM/FM measurement) are not available as upgrades and must be ordered at the time of instrument purchase.
Important: Specifications apply after a warm-up time of 30 minutes and at least two hours of operation or storage at operating temperature, and within a valid calibration period. Data with no given tolerances are typical values only; data designated as 'typical' is not covered by the product warranty.
Important: Maximum safe input level: average continuous power ≥ +33 dBm (3 minutes maximum, input attenuator setting ≥ 20 dB) and 50 VDC maximum.
Important: An xDSL probe from Vierling is required to connect the N9340B analyzer to xDSL networks for measurements in the field (not included; required for option XDM xDSL measurements).
Important: High-accuracy USB power measurement requires an Agilent U2000 series USB power sensor (sold separately).

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Pre-Owned

Manufacturer

Agilent

Spec_ana_freq

100 kHz to 3 GHz

PA3

3 GHz preamplifier

TG3

3 GHz tracking generator