Skip to product information
1 of 1
Used

Agilent E1616A 1.5/45 Mb/s (DS1/DS3) Line Interface Module (Pre-Owned)

Agilent E1616A 1.5/45 Mb/s (DS1/DS3) Line Interface Module (Pre-Owned)

Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Agilent E1616A 1.5/45 Mb/s (DS1/DS3) Line Interface Module (Pre-Owned)

Key Features At A Glance

  • Selectable DS1 (1.544 Mb/s) or DS3 (44.736 Mb/s) operation in a single module
  • Selectable direct or PLCP mapping per ANSI, ITU-T G.804, UNI 3.0, and Bellcore TR-TSV-000773
  • Cell-based ATM generation and analysis at the physical and ATM cell layers
  • Internal traffic generator with 1 foreground channel and up to 100 background channels
  • Three operating modes: Terminal, Repeater, and Local Loopback
  • Physical layer error and alarm generation including AIS, Yellow, IDLE, and bit error injection
  • ATM cell capture (1,500 cells) and PLCP frame capture (256 frames) with manual or event triggering
  • Single-slot C-size VXI card designed for the E4200/E4210 BSTS chassis
Share on
View full details

The Agilent E1616A 1.5/45 Mb/s (DS1/DS3) Line Interface is a single-slot module for the Broadband Series Test System (BSTS) that generates and analyzes ATM cell streams contained within DS1 or DS3 framing formats. Operating as part of the modular E4200/E4210 BSTS platform, the E1616A delivers test capability at both the physical and ATM cell layers, supporting direct and PLCP mapping schemes across the two transmission rates from a single instrument.

The datasheet identifies the E1616A's applications across the Broadband Series Test System ecosystem: R&D engineering, product development, quality assurance, performance testing, type approval, and conformance testing of ATM and B-ISDN equipment. The module is used for transmission test functionality including traffic generation, cell error/loss/delay measurements, and traffic capture and playback. It pairs with other BSTS line interfaces, the E4209 Cell Protocol Processor for ATM and adaptation layer testing, and the E4219 ATM Network Impairment Emulator for impairment-based performance characterization.

ValueTronics International specializes in legacy modular test platforms like the Agilent Broadband Series Test System and the line interface modules built for it. Modules like the E1616A are inventoried, inspected, and tested at our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois, where our technicians verify functional operation of these cards against the documented performance and confirm the accessory and configuration details before shipment. For labs maintaining established BSTS installations or sourcing replacement modules for production test systems built around this platform, having a domestic source that handles the hardware professionally — rather than relying on unverified marketplace listings for a discontinued modular platform — meaningfully reduces the risk of receiving a non-functional card.

Brand Heritage

The E1616A was originally developed and sold by Hewlett-Packard's test and measurement division and carries the Agilent Technologies branding from the 1999 spin-out of HP's test and measurement business. Agilent's electronic measurement business was subsequently transferred to Keysight Technologies in 2014. The Broadband Series Test System product line, including line interface modules like the E1616A, has been discontinued and is no longer in active production; documentation and historical product information remain associated with the Agilent and Keysight names depending on the era.

Product Core & Specifications

Category Parameter Specification
Modes Tx/Rx Modes Terminal, Repeater, Local Loopback
Total Bandwidth (DS1) 1.413 Mb/s
Total Bandwidth (DS3) 40.704 Mb/s
ATM Cell Generation Modes User-Network Interface (UNI) or Network-Node Interface (NNI)
HEC Automatic generation
Fill Cells Idle or unassigned
Channel Priority Order Foreground, background, CPP (highest to lowest priority)
Channel Control VCI, VPI, GFC, Payload Type, Cell Loss Priority
SAR-PDU Support AAL-0, AAL-1
Foreground Channel Bandwidth DS1: 100 b/s to 1.413 Mb/s; DS3: 100 b/s to 40.704 Mb/s
Accuracy +/- 0.02 ppm
Distribution Off, Single burst, Periodic (according to specified bandwidth)
Channel Depth 1500 cells (variable)
Cell Payload Timestamp, Single cell PRBS, Cross cell PRBS, Data pattern, Byte access
Background Channels Number of Channels Up to 100
Bandwidth DS1: 3 kb/s to 1.413 Mb/s; DS3: 3 kb/s to 40.704 Mb/s
Accuracy +/- 10 ppm
Distribution Off, Periodic
Channel Depth 16 cells
Cell Payloads Payloads Timestamp (32-bit departure timestamp with 100 ns resolution), Cross cell PRBS-9, PRBS-15 (inverted and not inverted), PRBS-23, Single cell PRBS-9, Data pattern or byte access
Data Patterns User edit; AA55h or FF00; Incrementing (each successive byte +1)
Byte Access Payload of all cells in selected channel editable in active channel environment or off-line as sequence of PDUs; AAL-1 automatically inserts first payload byte containing SN/SNP values and CSI bit
Erroring Control Error Stressing Control Off; On; Pulse On; Pulse Off; Sequence On; Sequence Off
ATM Error Injection Cell header or payload bytes with bit error masking
Cell Loss Sequence Number in SAR-PDU is skipped and a fill cell is inserted
PRBS Error Add Single bit error add to PRBS pattern in cell payload
DS1, DS3 & PLCP Stressing DS1/PLCP Alarm Generation AIS, Yellow
DS3/PLCP Alarm Generation AIS, IDLE, Yellow
DS1 Error Injection DS1 bit errors
DS3 Error Injection F-bit invert, P-bit invert, CP-bit invert, C-bit FEBE, DS3 bit errors
PLCP Error Injection BPI error add, FEBE generation, C1 bit masking (DS3 only)
PLCP Overhead Stressing Normal and alternative values can be defined for overheads; Pulse or sequence controls over normal and alternative overheads
Measurements Measurement Period 1 second to 3 days in resolutions of 1 second
Result Types Cumulative or latched (based on most recent measurement period)
Result Formats Count, Ratio, Seconds
ATM Cell Measurements Bad Headers, Selected Cell Count, Corrected headers, Cell loss count, Selected Cell bandwidth, Select Cell Not Received (SCNR) errored seconds
Cell Delay Measurements Cell delay, Inter-arrival time, Cell delay variation
Virtual Channel Errors AAL-1 SN/SNP errors, Cell loss, PRBS errors, PRBS sync loss alarm seconds
DS1 Measurements Code errors, CRC-6 errors, Loss of signal alarm seconds, Out-of-frame alarm seconds, AIS alarm seconds, Yellow alarm seconds, Frame count
DS3 Measurements Coding violations, Parity errors, C-bit parity errored seconds, FEBE errors, Loss of signal errored seconds, Out-of-frame errored seconds, AIS errored seconds, IDLE errored seconds, Yellow errored seconds, Frame count
PLCP Measurements PLCP Measurements BIP errors, FEBE errors, Trailer mismatches, OOF errored seconds, Yellow errored seconds, Frame count
ATM Capture Capacity 1500 cells from selected ATM cell stream; Manual triggering captures 1500 cells after trigger; Event triggering captures 750 cells pre-trigger and 750 cells post-trigger
ATM Cell Triggers Manual (user request); Cell loss; Header error; PRBS error; SN/SNP byte error
PLCP Capture Capacity 256 PLCP frames (overhead and ATM cell payload); Manual triggering captures 256 frames after trigger; Event triggering captures 128 frames before and 128 frames after trigger
On Change Trigger Triggered when change detected in value of selected overhead byte; selected bits of trigger byte can be disabled
On Value Trigger Triggered when user-defined value is detected in selected overhead byte; any PLCP overhead byte can be selected as trigger byte
On Event Trigger Triggered when defined PLCP event occurs (Yellow Alarm, FEBE, BIP, Error, Trailer Error)
Front Panel Connectors DS1 Input RJ48C or Bantam connector; 100 ohm impedance; 1.544 Mb/s; 0 dB or -20 dB relative to High, Xconnect and Low levels
DS1 Output RJ48C or Bantam connector; 75 ohm impedance; 1.544 Mb/s; Peak voltage may be set to High (9.5V), Xconnect (6.0V), Low (3.8V) transmit levels; Internal (stratum 3), External, and Recovered clock modes
DS3 Input BNC connector; 75 ohm impedance; 44.736 Mb/s +/- 10 ppm; B3ZS code; 0 dB or -20 dB relative to High, Xconnect and Low levels
DS3 Output BNC connector; 75 ohm impedance; 44.736 Mb/s; B3ZS code; Peak voltage may be set to High (850 mV), Xconnect (710 mV), Low (300 mV) transmit levels; Internal (stratum 3), External, and Recovered clock modes
External Clock Input SNB connector; TTL input; Nominal 50 ohm impedance
Trigger Output SNB connector; TTL output; Nominal 50 ohm impedance
LED Indicators Failed, Error, Access, Gating, Signal, OOF, AIS, BIP, Yellow, SCNR, Reference Clock
Physical Size 1 slot C-size VXI card
Weight 1.3 kg (2.9 lb) nominal
Power Dissipation 25 Watts (max)
Applicable Standards ATM Cells ITU-T Recommendation I.361 1995 B-ISDN ATM layer specification; Bellcore TA-NWT-001113 1993 ATM and AAL Protocols Generic Requirements
DS1/DS3 Frames ANSI T1.107-1995; ITU-T G.703 1991; Bellcore TR-TSY-000499 Issue 5 Dec. 1993
PLCP Frames IEEE 802.6 1994; Bellcore TR-TSV-000773 1993; ITU-T G.804 1993; ATM Forum UNI Version 3.0 1993
Input & Output Signal ANSI T1.102-1993 Digital Hierarchy Electrical Interfaces
PRBS Patterns PRBS-9 as per ITU-T O.153 1992; PRBS-23 as per ITU-T O.151 1992
EMC Meets FTZ 1046/1984 (CISPR11, EN 55011)
Mappings Supported DS3 direct (ANSI draft T1S1/94-243); DS3 PLCP (UNI Version 3.0); DS1 direct (ITU G.804); DS1 PLCP (Bellcore TR-TSV-000773 Issue 1, June 1991)
Important: Designed for the Agilent E4200/E4210 Broadband Series Test System chassis. Requires a BSTS chassis to operate.Important: The E1616A is a 1-slot C-size VXI card that requires a Broadband Series Test System chassis (E4200A/B Form-7 Transportable Chassis or E4210A/B Form-13 Mainframe Chassis) to operate; the chassis is not included with this module.Important: Operation with the E4209 Cell Protocol Processor is required to access ATM and adaptation layer protocol testing functions performed via optional protocol testing software applications.Recommended pairing: combine with the E4209 Cell Protocol Processor for ATM and AAL protocol testing, or with the E4219 ATM Network Impairment Emulator for impairment-based performance characterization, as described in the datasheet's configuration guidance.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No