Skip to product information
1 of 1
Used
lab tested

8564EC Agilent Spectrum Analyzer Used

8564EC Agilent Spectrum Analyzer Used

Calibrations
Check Pricing

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Key Features at a Glance

  • Portable swept-tuned spectrum analyzer — 9 kHz (30 Hz with Option 006) to 40 GHz internal mixing
  • External mixing extends coverage to 325 GHz
  • Resolution bandwidth: 1 Hz to 1 MHz (1, 3, 10 sequence) plus 2 MHz; selectivity < 15:1
  • Displayed average noise level down to −149 to −140 dBm (1 Hz RBW, frequency dependent)
  • Reference level range: −120 to +30 dBm (log), 0.1 dB steps
  • 300 MHz, −10 dBm calibrator output for absolute amplitude reference
  • GPIB (IEEE-488), HP-IB plotter/printer support; sweep out, blanking/gate I/O
  • Time-gated spectrum analysis (edge and level modes)
Share on
View full details

Overview

In summary, the Agilent (HP) 8564EC is a portable swept-tuned RF/microwave spectrum analyzer covering 9 kHz (30 Hz with Option 006) to 40 GHz with internal mixing, and up to 325 GHz with external waveguide mixers. The 8564EC provides resolution bandwidths from 1 Hz to 2 MHz, displayed average noise level performance suitable for low-level signal work, and a complete suite of trigger, sweep, and time-gated measurement modes.

What is the Agilent 8564EC used for?

The 8564EC is used for RF and microwave signal observation in the frequency domain — identifying signals, measuring their power, characterizing harmonics and spurious emissions, performing EMC pre-compliance measurements, monitoring transmitter output, and hunting interference. With the appropriate option, the 8564EC also performs time-gated spectrum analysis for burst signals and TDMA waveforms.

How does the 8560 family compare to modern analyzers?

The 8560 E-Series predates the current X-Series (Keysight N9000 family). The architecture is swept-tuned rather than FFT-based, which means the 8564EC is at its best with narrowband signals, harmonic searches, and CW measurements rather than wide-instantaneous-bandwidth modulated-signal analysis. For traditional swept spectrum measurements, the 8564EC remains a fully capable, well-supported, well-documented instrument with a deep installed base and extensive aftermarket support.

Technical Grounding

Frequency reference accuracy with the standard timebase is ±1 × 10−7/year aging plus ±1 × 10−8 temperature stability over −10 to +55 °C. With Option 103 the aging tightens to ±1 × 10−7/year and initial achievable accuracy to ±2.2 × 10−8. Noise sidebands at 1 GHz center, 10 kHz offset are ≤ −113 dBc/Hz. Marker counter accuracy at 1 GHz with 1 Hz resolution is ±225 Hz after 5-minute warm-up.

Industry Position

The 8560 family was Hewlett-Packard's (later Agilent's) flagship portable spectrum analyzer line in the late 1990s and 2000s. Even today, the family remains heavily represented in defense, aerospace, calibration laboratory, and university research environments where existing test procedures, fixtures, and remote-control programs are written specifically around 8560-series command sets. The product is fully compatible with HP/Agilent 33330D/E external detectors, 85370 series external mixers (up to 325 GHz), and standard IEEE-488 automation.

Notable Capabilities

  • Time-gated spectrum analysis with edge mode (gate delay 3 µs to 65.535 ms, 1 µs resolution) and level mode (≤ 0.5 µs gate delay).
  • Demodulation: AM and FM with speaker, phone jack, and adjustable marker pause time (100 ms to 60 s).
  • Spurious response performance: residual responses ≤ −90 dBm from 200 kHz to 6.46 GHz (no input, 0 dB attenuation).
  • Multiple display traces, max-hold, min-hold, and average modes with full marker functionality.

Accessories Supplied

The 8564EC is supplied with the standard accessory complement for the instrument. Optional external waveguide mixers (for coverage above 18 GHz internal limit), tracking generators, frequency reference cables, and rack-mount kits are configured on a per-order basis. Contact your Test Architect to confirm the connector type, option set, and any required adapters for your test setup.

Core Specifications

Frequency

Internal mixing range 9 kHz (30 Hz with Option 006) to 40 GHz
External mixing range 18 GHz to 325 GHz (with external mixers)
Frequency span range 0 Hz, 100 Hz to full span
Frequency span accuracy ±5% (span > 2 MHz × N); ±1% (span ≤ 2 MHz × N)
Marker counter resolution Selectable 1 Hz to 1 MHz

Resolution & Video Bandwidth

RBW range 1 Hz to 1 MHz (1, 3, 10 sequence) plus 2 MHz (3 MHz at −6 dB)
RBW accuracy 1 Hz to 300 kHz ±10%; 1 MHz ±25%; 2 MHz +50%/−25%
RBW selectivity (−60 dB / −3 dB) < 15:1 (RBW ≥ 300 Hz); < 5:1 (RBW ≤ 100 Hz)
VBW range 1 Hz to 3 MHz (1, 3, 10 sequence)

Amplitude

Displayed average noise level (0 dB atten, 1 Hz RBW, in band) ≤ −145 dBm
Reference level range (log) −120 to +30 dBm in 0.1 dB steps
Maximum safe input (average) +30 dBm (1 W) with input attenuation ≥ 10 dB
Peak pulse input +50 dBm (100 W, ≤ 10 µs pulse width, < 1% duty cycle, with input attenuation ≥ 30 dB)
Maximum DC input voltage (DC coupled) ±0.2 VDC
Maximum DC input voltage (AC coupled) ±50 VDC

Noise Sidebands (1 GHz center, dBc/Hz)

Offset Standard Option 103
100 Hz ≤ −88 ≤ −70
1 kHz ≤ −97 ≤ −90
10 kHz ≤ −113 ≤ −113
100 kHz ≤ −117 ≤ −117

Sweep Time

  • Span = 0 Hz: 50 µs to 6000 s
  • Span ≠ 0 Hz, RBW ≥ 300 Hz: 50 ms to 2000 s
  • Span ≠ 0 Hz, RBW ≤ 100 Hz: 50 ms to 100 ks
  • Trigger modes: delayed, free run, single, line, video, external

Inputs & Outputs (front panel)

RF input Type N female (8560E/61E/62E/63E); APC 3.5 mm male (8563E Option 026); APC 2.4 mm male (8564E/65E)
Input VSWR (≥ 10 dB atten) < 1.5:1 from 30 Hz to 2.9 GHz; < 2.3:1 from 2.9 to 50 GHz
LO emission level ≤ −80 dBm (average, 10 dB attenuation)
IF input SMA female, 50 Ω, 310.7 MHz, full-screen level −30 dBm
1st LO output SMA female, 50 Ω, 3.000–6.8107 GHz, +16.5 dBm ±2.0 dB
Cal output 300 MHz at −10 dBm ±0.3 dB
Probe power +15 VDC, −12.6 VDC, GND (150 mA max each)

Rear Panel I/O

  • 10 MHz reference in/out (shared BNC); output 0 dBm, input −2 to +10 dBm
  • Video output (BNC, 50 Ω, 0 to +1 V full scale at RBW ≥ 300 Hz)
  • LO sweep / V-per-GHz analog output (BNC, 120 Ω)
  • Blanking/gate output; external/gate trigger input (selectable high/low TTL)
  • GPIB (IEEE-488) with full talker/listener capability; direct printer (HP 2225/3630) and plotter (HP 7440/7470/7475/7550) support

General Specifications

Operating temperature −10 °C to +55 °C
Storage temperature −51 °C to +71 °C
Humidity 95% RH at 40 °C for 5 days
Power requirements 115 VAC (90–140 V) or 230 VAC (180–250 V); 47–440 Hz at 115 V, 47–66 Hz at 230 V
Maximum power dissipation 260 W
Dimensions (no handle/cover) 337 mm W × 187 mm H × 461 mm D
Weight 21 kg (46 lb)
Per MIL-T-28800, Type III, Class 5, Style C
Important Note: Maximum safe average continuous input power is +30 dBm (1 W) with input attenuation ≥ 10 dB. Peak pulse power of +50 dBm requires input attenuation ≥ 30 dB and pulse widths ≤ 10 µs with < 1% duty cycle. Maximum DC input is ±0.2 VDC (DC coupled) or ±50 VDC (AC coupled). Exceeding these limits will damage the first mixer or input attenuator. Always confirm signal levels and use external attenuation as appropriate.

About This Pre-Owned Unit

  • Warranty included.
  • Functional verification included.
  • Calibration available as an optional add-on service.
  • Unnecessary accessories may not be included; contact a Test Architect to confirm anything specific.

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

8564EC

Condition

Used

Manufacturer

Agilent

Frequency

40 GHz

1

Second IF Output (310.7 MHz) provided at rear panel connector J10

5

Add alternate sweep output

6

Extends lower frequency coverage to 30 Hz

7

Digitized fast time domain sweeps

8

Adds signal identification

26