The Agilent 6628A is a precision multiple-output system DC power supply. Its 2 isolated outputs are integrated into one 3U package, conserving rack space and GPIB addresses; dual ranges allow for more current at lower voltage levels, and the outputs can be connected in parallel or series.
The Agilent 6628A is controlled from the front panel keypad or, for automated testing, from the GPIB with industry standard SCPI commands and VXIplug&play drivers. An active down-programmer can sink the full rated current, and on the R&D bench the accuracy of the programming and measurement systems allows precise control and monitoring of prototype bias power.
Conditions the data sheet sets for its specifications:
| Parameter | Value |
|---|---|
| Output type | 50 W output |
| Total number of outputs | 2 |
| Number of 25 W outputs | — |
| Number of 50 W outputs | 2 |
| Parameter | Value | Conditions |
|---|---|---|
| Low range voltage | 0 to 16 V | — |
| Low range current | 0 to 200 mA | — |
| High range voltage, current | 0 to 50 V, 0 to 1 A | printed as one cell: 0 to 50 V, 0 to 1 A or 0 to 16 V, 0 to 2 A |
| High range voltage, current, alternative | 0 to 16 V, 0 to 2 A | printed as one cell: 0 to 50 V, 0 to 1 A or 0 to 16 V, 0 to 2 A |
Conditions: at 25 °C ± 5 °C
| Parameter | Value |
|---|---|
| Voltage, low range: 0.16% + | 3 mV |
| Voltage, high range: 0.16% + | 10 mV |
| Current, low range: 0.04% + | 185 μA |
| Current, high range: 0.04% + | 500 μA |
Conditions: at 25 °C ± 5 °C
| Parameter | Value |
|---|---|
| Voltage, low range: 0.16% + | 3.5 mV |
| Voltage, high range: 0.16% + | 10 mV |
| ± Current, low range: 0.03% + | 250 μA |
| ± Current, high range: 0.03% + | 550 μA |
| Parameter | Value | Conditions |
|---|---|---|
| Constant voltage ripple and noise, rms | 500 μV | rms, 20 Hz to 10 MHz |
| Constant voltage ripple and noise, peak-to-peak | 3 mV | peak-to-peak, 20 Hz to 20 MHz |
| Constant current ripple and noise, rms | 0.1 mA | rms, 20 Hz to 10 MHz |
| Parameter | Value |
|---|---|
| Load regulation, voltage | 0.5 mV |
| Load regulation, current | 0.01 mA |
| Load cross regulation, voltage | 0.25 mV |
| Load cross regulation, current | 0.01 mA |
| Line regulation, voltage | 0.5 mV |
| Line regulation, current | 0.01 mA |
Conditions: for the output voltage to recover to within 75 mV of nominal value following a load change within specifications
| Parameter | Value |
|---|---|
| Transient response time | Less than 75 μs |
The Agilent 6628A has 2 outputs, and the output combinations table lists 2 of them as 50 W outputs and none as 25 W outputs. Count the separate rails your device needs; the outputs can also be connected in parallel or series.
Each 50 W output of the Agilent 6628A has a low range of 0 to 16 V and 0 to 200 mA, and a high range of 0 to 50 V, 0 to 1 A or 0 to 16 V, 0 to 2 A. Check your device's highest voltage and current, including any start-up peak, against the range you will use.
The Agilent 6628A low-range current readback accuracy at 25 °C ± 5 °C is 0.03% + 250 μA on each 50 W output, and the average current programming resolution on the low range is 13 μA.
The Agilent 6628A remote sensing allows up to 10 V drop per load lead; the drop in the load leads is subtracted from the voltage available for the load, so allow for it at the top of the range.
The Agilent 6628A output terminals can be floated up to ± 240 VDC from chassis ground.
The Agilent 6628A input power is stated as 550 W max., 720 VA max., and the line input is set by option: Option 100 sets 87 to 106 VAC, 47 to 66 Hz, 6.3 A (Japan only); Option 120 sets 104 to 127 VAC, 47 to 63 Hz; Option 220 sets 191 to 233 VAC, 47 to 66 Hz, 3.0 A; Option 240 sets 209 to 250 VAC, 47 to 66 Hz, 3.0 A. Check which option a unit has before connecting it.
Voltage, current and power envelope. DC power = voltage × current. The required voltage and current, including any start-up peak, must both lie inside the stated ranges, and their product inside the stated power — on autoranging outputs the power limit is lower than maximum voltage × maximum current. Rule of thumb, not a specification.
Example with the Agilent 6628A: Each 50 W output of the Agilent 6628A has a high range of 0 to 50 V, 0 to 1 A; 50 V × 1 A = 50 W, equal to its 50 W rating, so full voltage and full current are available at the same time.
The line-voltage, relay-control, remote-inhibit and documentation options, rack-mount kits and accessories for the Agilent 6628A are listed on the Options tab.
| Parameter | Value | Conditions |
|---|---|---|
| Average programming resolution, voltage, low range | 1 mV | — |
| Average programming resolution, voltage, high range | 3.2 mV | — |
| Average programming resolution, current, low range | 13 μA | — |
| Average programming resolution, current, high range | 131 μA | — |
| Average programming resolution, OVP | 230 mV | — |
| Output programming response time | 6 ms | time to settle within 0.1% of full scale output, after Vset command has been processed |
| Parameter | Value | Conditions |
|---|---|---|
| DC floating voltage | up to ± 240 VDC | output terminals from chassis ground |
| Remote sensing | Up to 10 V drop per load lead | The drop in the load leads is subtracted from the voltage available for the load |
| Command processing time | 7 ms typical with front-panel display disabled | — |
| Parameter | Value |
|---|---|
| Input power | 550 W max., 720 VA max. |
| Software driver | VXIplug&play |
| Size | 425.5 mm W x 132.6 mm H x 497.8 mm D (16.75 in x 5.22 in x 19.6 in) |
| Net weight | 15.5 kg (34 lb) |
| Shipping weight | 20.8 kg (46 lb) |
| Output terminal strip screw size | M3.5 x 0.6 |
| Parameter | Value |
|---|---|
| Series | 6620A Series Precision Multiple-Output, 25-50 W DC Power Supplies, GPIB |
| Outputs | Two or four isolated outputs are integrated into one package, conserving rack space and GPIB addresses |
| Dual ranges | Dual ranges allow for more current at lower voltage levels |
| Parallel or series connection | The outputs can be connected in parallel or series |
| Programming | industry standard SCPI commands; VXIplug&play drivers |
| Down-programming | active down-programmer which can sink the full rated current |
| Bench use | The accuracy of both the programming and the measurement systems allow precise control and monitoring of prototype bias power |
| Control | front panel keypad or, for automated testing, from the GPIB |
| Package | Up to four fully isolated power supplies in a 3U package |
| Protection | Protection features to ensure DUT safety |
The Agilent 6628A has 2 isolated outputs, all of them 50 W outputs (2 in the data sheet's output combinations table).
Each 50 W output of the Agilent 6628A has a low range of 0 to 16 V and 0 to 200 mA, and a high range of 0 to 50 V, 0 to 1 A or 0 to 16 V, 0 to 2 A.
Each 50 W output of the Agilent 6628A has a voltage programming accuracy at 25 °C ± 5 °C of 0.16% + 3 mV on the low range and 0.16% + 10 mV on the high range, and a current programming accuracy of 0.04% + 185 μA (low) and 0.04% + 500 μA (high). Readback accuracy is 0.16% + 3.5 mV (low) and 0.16% + 10 mV (high) for voltage, and 0.03% + 250 μA (low) and 0.03% + 550 μA (high) for current.
The Agilent 6628A constant voltage ripple and noise on each 50 W output is 500 μV rms (20 Hz to 10 MHz) and 3 mV peak-to-peak (20 Hz to 20 MHz); constant current ripple and noise is 0.1 mA rms.
The Agilent 6628A output voltage recovers to within 75 mV of nominal value in less than 75 μs following a load change within specifications.
The Agilent 6628A is programmed with industry standard SCPI commands over GPIB or from the front panel keypad, with a VXIplug&play software driver; command processing time is 7 ms typical with front-panel display disabled, and the output programming response time is 6 ms (time to settle within 0.1% of full scale output after the Vset command has been processed).
The Agilent 6628A has remote sensing that allows up to 10 V drop per load lead; the drop in the load leads is subtracted from the voltage available for the load.
The Agilent 6628A is used in automated test systems, where its isolated outputs in one package conserve rack space and GPIB addresses, and on the R&D bench, where the accuracy of the programming and measurement systems allows precise control and monitoring of prototype bias power.
The Agilent 6628A measures 425.5 mm W x 132.6 mm H x 497.8 mm D (16.75 in x 5.22 in x 19.6 in); its net weight is 15.5 kg (34 lb) and its shipping weight 20.8 kg (46 lb).
The Agilent 6628A rack mounts with the 1CM003A rack mount flange kit or the 1CP002A flange and handle kit, both 132.6 mm H (3U); support rails are required, such as the E3663AC support rails for Agilent rack cabinets.
The Agilent 6628A and the other 6620A Series models differ in how many 25 W and 50 W outputs they combine; the 6628A has 2 outputs, all of them 50 W, and no 25 W outputs. The compare table on this page lists each model.
The Agilent 6628A sources DC power to a device at a programmed voltage or current; an electronic load does the opposite and absorbs power from a source under test, such as a power supply or a battery.
Specifications are from the manufacturer's data sheet (Agilent 6620A Series Precision Multiple-Output, 25-50 W DC Power Supplies, GPIB Data Sheet, 5991-0033EN, March 26, 2012). Questions? Contact your Test Architect.
Updated 2026-11-25
Model No
Agilent
Condition
Used
Manufacturer
Agilent
Current
1 A
Voltage
50 V
Power
50 W
100
87 to 106 VAC, 47 to 66 Hz, 6.3 A (Japan only).
120
104 to 127 VAC, 47 to 63 Hz.
220
191 to 233 VAC, 47 to 66 Hz, 3.0 A.
240
209 to 250 VAC, 47 to 66 Hz, 3.0 A.
750
Relay control and DFI/RI.
S50
Similar to Option 750, however the remote inhibit does not latch.
0L1
Printed operating manual.
0B3
Printed service manual.
1CM003A
Rack mount flange kit 132.6 mm H (3U) – two flange brackets. Support rails required.
1CP002A
Rack mount flange and handle kit 132.6 mm H (3U) – two brackets and front handles. Support rails required.
E3663AC
Support rails for Agilent rack cabinets.
1494-0059
Rack slide kit.