Key Features At A Glance

  • 10,000 count display with true RMS AC voltage and current measurement
  • 0.09% basic DC voltage accuracy
  • CAT III 1000 V overvoltage protection; certified to CE, UL, and CSA standards
  • Measures ACV, DCV, ACI, DCI, resistance, frequency, diode, and continuity
  • Capacitance, temperature to 1000 °C, and MIN/MAX recording functions
  • Adjustable backlighting with two intensity levels for subdued conditions
  • Manual data logging, harmonic ratio, and differential temperature on the U1242A
  • Includes certificate of calibration and test report at no extra cost
View full details

The Agilent U1240A Series handheld digital multimeters are designed to check more across wide measurement ranges, presenting readings on a 10,000 count display. The series comprises the U1241A and U1242A, both delivering true RMS AC measurement so that complex and non-sinusoidal waveforms are read accurately. A dual display reserves a secondary 4-digit readout for the temperature function, and automatic polarity indication is provided.

These handheld meters target field and bench maintenance work where wide-range electrical measurement is needed in a single portable instrument. Adjustable backlighting lets the operator complete jobs in subdued lighting while helping to prolong battery life. Built-in capabilities such as the switch counter, harmonic ratio, and dual and differential temperature readings (on the U1242A) are accessed with a single button press to simplify routine maintenance tasks.

ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer. This combination of held inventory and in-house verification lets engineers and technicians source the right instrument with confidence in its condition.

Brand Heritage

Agilent Technologies was spun off from Hewlett-Packard in 1999. In 2014, Agilent's electronic test and measurement business was transferred to a new company, Keysight Technologies, which now carries that product line forward.

Compare Other Models in This Series

The U1240A Series is offered in two models, the U1241A and the U1242A. Both share the same 10,000 count display, true RMS AC measurement, 0.09% basic DC voltage accuracy, and CAT III 1000 V safety rating, so the core measurement performance is common across the series.

The two models differ in their set of advanced and convenience functions rather than in their fundamental ranges or accuracy. The comparison table below lists each function alongside the model that provides it.

Each model below is its own dedicated product page with pre-owned-matched pricing. Select the model that fits your measurement needs, then choose the condition and configuration on that model's page.

The U1242A extends the shared feature set with manual data logging, harmonic ratio measurement, dual and differential T1–T2 temperature capability, and J-type thermocouple support, in addition to the K-type support common to both models.

The U1241A and U1242A share identical voltage, current, resistance, frequency, diode, capacitance, and K-type temperature specifications. The differences lie in the U1242A's additional functions: manual data logging, harmonic ratio, dual and differential temperature, and J-type thermocouple support.

Refer to the comparison table that follows for a function-by-function breakdown of which capabilities each model provides, so the selection can be matched to the specific maintenance and measurement tasks at hand.

Model Display Count Data Logging Harmonic Ratio
U1241A 10,000 No No
U1242A 10,000 Yes (Manual) Yes

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Four 1.5 V AAA alkaline batteries
  • Certificate of Calibration (CoC)
  • Test leads
  • Quick Start Guide
  • Product Reference CD

Product Core & Specifications

Specification Value
DC Voltage Accuracy ± (% of reading + No. of LSD), Input impedance 10 MΩ nominal
1000.0 mV range Resolution 0.1 mV; Accuracy 0.09% + 5
10.000 V range Resolution 0.001 V; Accuracy 0.09% + 2
100.00 V range Resolution 0.01 V; Accuracy 0.09% + 2
1000.0 V range Resolution 0.1 V; Accuracy 0.15% + 5
DC Current Accuracy ± (% of reading + No. of LSD)
1000.0 µA range Resolution 0.1 µA; Burden voltage < 0.06 V (50 Ω); Accuracy 0.1% + 3
10000 µA range Resolution 1 µA; Burden voltage < 0.55 V (50 Ω); Accuracy 0.1% + 3
100.00 mA range Resolution 0.01 mA; Burden voltage < 0.18 V (0.5 Ω); Accuracy 0.2% + 3
440.0 mA range Resolution 0.1 mA; Burden voltage < 0.8 V (0.5 Ω); Accuracy 0.5% + 3
10.000 A range Resolution 0.001 A; Burden voltage < 0.4 V (0.01 Ω); Accuracy 0.6% + 5
Resistance Accuracy ± (% of reading + No. of LSD), Max open voltage < 2.8 V
1000.0 Ω range Resolution 0.1 Ω; Test current 0.5 mA; Accuracy 0.3% + 3
10.000 kΩ range Resolution 0.001 kΩ; Test current 50 µA; Accuracy 0.3% + 3
100.00 kΩ range Resolution 0.01 kΩ; Test current 4.91 µA; Accuracy 0.3% + 3
1000.0 kΩ range Resolution 0.1 kΩ; Test current 447 nA; Accuracy 0.3% + 3
10.000 MΩ range Resolution 0.001 MΩ; Test current 112 nA; Accuracy 0.8% + 3
100.00 MΩ range Resolution 0.01 MΩ; Test current 112 nA; Accuracy 1.5% + 3
Diode Test
1 V range Resolution 0.001 V; Test current approximately 0.5 mA; Accuracy 0.3% + 2
AC Voltage Accuracy ± (% of reading + No. of LSD), True RMS, AC coupled, valid 5% to 100% of range
1000.0 mV range Resolution 0.1 mV; 1% + 5 (40 Hz–500 Hz); 2% + 5 (500 Hz–1 kHz)
10.000 V range Resolution 0.001 V; 1% + 5 (40 Hz–500 Hz); 2% + 5 (500 Hz–1 kHz)
100.00 V range Resolution 0.01 V; 1% + 5 (40 Hz–500 Hz); 2% + 5 (500 Hz–1 kHz)
1000.0 V range Resolution 0.1 V
AC Current Accuracy ± (% of reading + No. of LSD), True RMS, AC coupled
1000.0 µA range Resolution 0.1 µA; Burden voltage < 0.06 V (50 Ω); 1% + 5 (40 Hz–500 Hz); 1.5% + 5 (500 Hz–1 kHz)
10000 µA range Resolution 1 µA; Burden voltage < 0.55 V (50 Ω); 1% + 5 (40 Hz–500 Hz); 1.5% + 5 (500 Hz–1 kHz)
100.00 mA range Resolution 0.01 mA; Burden voltage < 0.18 V (0.5 Ω); 1% + 5 (40 Hz–500 Hz); 1.5% + 5 (500 Hz–1 kHz)
440.0 mA range Resolution 0.1 mA; Burden voltage < 0.8 V (0.5 Ω); 1% + 5 (40 Hz–500 Hz); 1.5% + 5 (500 Hz–1 kHz)
10.000 A range Resolution 0.001 A; Burden voltage < 0.4 V (0.01 Ω); 1% + 5 (40 Hz–500 Hz); 1.5% + 5 (500 Hz–1 kHz)
Temperature Accuracy ± (% of reading + offset error)
Type K (U1241A and U1242A) –40 to 1000 ºC / –48 to 1832 ºF; Resolution 0.1 ºC / 0.1 ºF; Accuracy 1% + 1 ºC / 1% + 1.8 ºF
Type J (U1242A only) –40 to 1000 ºC / –48 to 1832 ºF; Resolution 0.1 ºC / 0.1 ºF; Accuracy 1% + 1 ºC / 1% + 1.8 ºF
Capacitance Accuracy ± (% of reading + No. of LSD)
1000.0 nF range Resolution 0.1 nF; Accuracy 1.2% + 4
10.000 µF range Resolution 0.001 µF; Accuracy 1.2% + 4
100.00 µF range Resolution 0.01 µF; Accuracy 1.2% + 4
1000.0 µF range Resolution 0.1 µF; Accuracy 2% + 4
10.000 mF range Resolution 0.001 mF; Accuracy 2% + 4
Harmonic Ratio (U1242A only)
Range 0.0% to 99.9%
Frequency 40 Hz to 500 Hz
Voltage 100 mVAC to 1000 VAC
Frequency Accuracy
100.00 Hz range Resolution 0.01 Hz; Accuracy 0.03% + 3; Minimum input frequency 1 Hz
1000.0 Hz range Resolution 0.1 Hz; Accuracy 0.03% + 3
10.000 kHz range Resolution 0.001 kHz; Accuracy 0.03% + 3
100.00 kHz range Resolution 0.01 kHz; Accuracy 0.03% + 3
1000.0 kHz range Resolution 0.1 kHz; Accuracy 0.03% + 3
Frequency Sensitivity During Voltage Measurement (Minimum Sensitivity, RMS Sine-Wave)
1000.0 mV range 0.3 V (20 Hz–50 kHz); 0.6 V (50 kHz–200 kHz)
10.000 V range 0.5 V (20 Hz–50 kHz); 1.8 V (50 kHz–200 kHz)
100.00 V range 5 V (20 Hz–50 kHz); 10 V (<100 kHz)
1000.0 V range 50 V (20 Hz–50 kHz); 100 V (<100 kHz)
Frequency Sensitivity During Current Measurement (Minimum Sensitivity, RMS Sine-Wave, 20 Hz to 20 kHz)
1000.0 µA range 100 µA
10000 µA range 500 µA
100.00 mA range 10 mA
440.00 mA range 50 mA
10.000 A range 1 A
Operating Measuring Rate (Times/second)
ACV 7
DCV (V or mV) 7
Resistance (Ω) 14
Diode 14
Capacitance 4 (< 100 µF)
DCA (µA, mA, A) 7
ACA (µA, mA, A) 7
Temperature 7 (single)
Frequency 1 (> 10 Hz)
General Specifications
Power Supply 4 single standard 1.5 V AAA batteries (Alkaline or Zinc Chloride type)
Display Dual display (secondary display for temperature function only); 4-digit LCD with maximum reading of 11,000 counts; automatic polarity indication
Power Consumption 0.22 VA maximum
Operating Environment Full accuracy at –10 ºC to 55 ºC; full accuracy to 80% RH for temperature up to 30 ºC, decreasing linearly to 50% RH at 55 ºC
Storage Compliance –20 ºC to 70 ºC
Altitude 0 – 2000 meters per IEC 61010-1 2nd Edition CAT III, 1000 V
Safety Compliance IEC 61010-1:2001 / EN61010-1:2001; USA: UL 61010-1:2004; Canada: CSA C22.2 No. 61010-1:2004
Measurement Category CAT III 1000 V Overvoltage Protection, Pollution Degree 2
Important: After measuring current above 10 A, allow the meter to cool for 60 seconds before applying a low-current measurement. Continuous 10 A measurement applies at a maximum operating temperature of 50 °C.
Important: Manual data logging, harmonic ratio, and dual/differential temperature (T1–T2) capabilities are available on the U1242A only; the J-type thermocouple is supported on the U1242A only.
Important: The U1240A Series comes with a certificate of calibration and test report at no extra cost.
Recommended pairing: the optional U1583A AC current clamp extends the current measurement range up to 400 A.
Important: For the 100 MΩ range, relative humidity is specified for < 60%; the temperature coefficient is 0.15 times the specified accuracy when above 50 MΩ.
Recommended pairing: add the U1185A/U1186A J-type and K-type thermocouple probes for temperature work.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Pre-Owned

Manufacturer

Agilent

Multi_met_acv

1000 V

Multi_met_dcv

1000 V

Multi_met_type

True RMS