{"product_id":"tos9320-new-kikusui-hipot-new","title":"Kikusui TOS9320 High Voltage Scanner NEW","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput can be expanded to four channels with one high-voltage scanner. The electric potential of each channel can be arbitrarily set to high, low, or open, and can be tested at any of these four points.\u003c\/li\u003e\n\u003cli\u003eUp to four high voltage scanners (total 16 channels) can be connected to each unit.\u003c\/li\u003e\n\u003cli\u003eOutput of each channel and contact with testing points can be easily monitored.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe high-voltage scanner TOS9320 is a specialized option for the TOS9300 series, capable of rapidly distributing test voltage from the main unit to multiple testing points for withstanding voltage and insulation resistance testing. Channels can be controlled with an external device through the back panel CONTROLLER INTERFACE connector. Remote control is not limited to the TOS9300 series, but is also compatible with previous models such as the TOS5300 series hipot\/insulation resistance tester. The TOS9320 high-voltage scanner is an essential tool for the automation of highly reliable testing of electronic devices among multiple channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eItem\u003c\/th\u003e\n\u003cth\u003eTOS9320\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eMaximum Operating Voltag\u003c\/th\u003e\n\u003cth\u003eAC\u003c\/th\u003e\n\u003ctd\u003e5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC\u003c\/th\u003e\n\u003ctd\u003e7.2kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eNumber of channels\u003c\/th\u003e\n\u003ctd\u003e4 (Each channel can be set to high, low, or open.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eMaximum connections\u003c\/th\u003e\n\u003ctd\u003e4 units. Channel numbers are assigned according to the order in which connections are made to the TOS93 series tester. 1st scanner: CH1 to CH4, 2nd scanner:CH5 to CH8, 3rd scanner: CH9 to CH12, 4th scanner: CH13 to CH16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eContact check function\u003c\/th\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDisplay\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eTOS9320\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDANGER\u003c\/th\u003e\n\u003ctd\u003eLights up in sync with the TOS9300 series tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCHANNEL\u003c\/th\u003e\n\u003ctd\u003eIndicates the setting of each channel with color. Red: High, Green: Low, Orange: Contact being checked, Off: Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEXTERNAL\u003c\/th\u003e\n\u003ctd\u003eLights up when external control is on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePOWER\u003c\/th\u003e\n\u003ctd\u003eLights up when the power is on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInterface and other functions\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eItem\u003c\/th\u003e\n\u003cth\u003eTOS9320\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eControl switch\u003c\/th\u003e\n\u003ctd\u003eEXTERNAL I\/O switch for switching the following controls. ON: External control through the CONTROLLER INTERFACE OFF: Control from the TOS93 series tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eCONTROLLER INTERFACE (external control)\u003c\/th\u003e\n\u003ctd\u003eD-sub 25-pin connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eSets each channel to high or low or all channels to open. Outputs the setting of each channel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"5\"\u003eInput\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003ctd\u003eThe input signals are all low-active control. The input terminal is pulled up to +12 V by a resistor. Leaving the input terminal open is equivalent to applying a high level signal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHigh-level input voltage\u003c\/th\u003e\n\u003ctd\u003e11 V to 15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLow-level input voltage\u003c\/th\u003e\n\u003ctd\u003e0 V to 4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLow-level input current\u003c\/th\u003e\n\u003ctd\u003e-5 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput time width\u003c\/th\u003e\n\u003ctd\u003e5 ms min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"4\"\u003eOutput\u003c\/th\u003e\n\u003cth\u003eOutput method\u003c\/th\u003e\n\u003ctd\u003eOpen collector output (4.5 Vdc to 30 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput withstanding voltage\u003c\/th\u003e\n\u003ctd\u003e30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput saturation voltage\u003c\/th\u003e\n\u003ctd\u003eApprox. 1.1 V (25 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum output current\u003c\/th\u003e\n\u003ctd\u003e400 mA(TOTAL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eTOS9300 series tester interface\u003c\/th\u003e\n\u003ctd\u003eMINI DIN 8-pin connector. Accuracy guaranteed up to 4 units (16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eGeneral specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eItem\u003c\/th\u003e\n\u003cth\u003eTOS9320\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"7\"\u003eEnvironment\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eInstallation location\u003c\/th\u003e\n\u003ctd\u003eIndoors, 2000 m or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eWarranty range\u003c\/th\u003e\n\u003cth\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003e5°C to 35°C (41°F to 95°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e20%rh to 70%rh (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eOperating range\u003c\/th\u003e\n\u003cth\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003e0°C to 40°C (32°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e20 %rh to 80 %rh (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eStorage range\u003c\/th\u003e\n\u003cth\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C to 70 °C (-4 °F to 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e90 %rh or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"3\"\u003eAC line power requirements\u003c\/th\u003e\n\u003cth colspan=\"2\"\u003eNominal voltage range (allowable voltage range)\u003c\/th\u003e\n\u003ctd\u003e100 Vac to 240 Vac (90 Vac to 250 Vac)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e50 VA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eAllowable frequency range\u003c\/th\u003e\n\u003ctd\u003e47 Hz to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eInsulation resistance (between AC LINE and chassis)\u003c\/th\u003e\n\u003ctd\u003e30 MΩ or more (500 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eWithstanding voltage (between AC LINE and chassis)\u003c\/th\u003e\n\u003ctd\u003e1500 Vac, 1 minute, 20 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eEarth continuity\u003c\/th\u003e\n\u003ctd\u003e25 Aac\/0.1 Ω or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApprox. 8 kg (17.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eAccessories\u003c\/th\u003e\n\u003ctd\u003ePower cord (1 pc., length: 2.5 m: The attached power cord varies depending on the shipment destination.) High-voltage test lead [TL31-TOS] (8 red), Lead for high voltage parallel connection TL33-TOS (1 pair), Interface cable (1 pc.), CONTROLLER INTERFACE plug (1 set), High-voltage warning sticker (2 pc.), Channel labels (For the panel (1 sheet), For the test leads (1 sheet)), User’s manual (1 copy), Safety Information (1 copy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eElectromagnetic compatibility\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*2\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003eComplies with the requirements of the following directive and standards. EMC Directive 2014\/30\/EU, EN 61326-1 (Class A\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*3\u003c\/span\u003e), EN 55011 (Class A\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*3\u003c\/span\u003e, Group 1\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*4\u003c\/span\u003e), EN 61000-3-2, EN 61000-3-3 Applicable under the following conditions The maximum length of all cabling and wiring connected to this product is less than 2.5 m. A shielded cable is used for the connection to the CONTROLLER INTERFACE. The high-voltage test lead TL31-TOS is in use. Electrical discharges are applied only to the EUT.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eComplies with the requirements of the following directive and standards. Low Voltage Directive 2014\/35\/EU\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*2\u003c\/span\u003e, EN 61010-1 (Class I\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*5\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e, Pollution Degree 2\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*6\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"ps\"\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDoes not apply to specially ordered or modified products.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*2\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOnly on models that have CE\/UKCA marking on the panel.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*3\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*4\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis is a Group 1 instrument. This product does not generate and\/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and\/or capacitive coupling, for the treatment of material or inspection\/analysis purpose.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*5\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*6\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ePollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non- conductive pollution will occur except for an occasional temporary conductivity caused by condensation.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-ascii-font-family: Aptos; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Aptos; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi;\"\u003e*The image is for reference only. See product specification for details.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Kikusui","offers":[{"title":"Default Title","offer_id":51100634448119,"sku":"70867","price":2920.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/Kikusui_TOS9320.jpg?v=1788720048","url":"https:\/\/valuetronics.com\/products\/tos9320-new-kikusui-hipot-new","provider":"ValueTronics","version":"1.0","type":"link"}