{"product_id":"tos9311-new-kikusui-hipot-new","title":"Kikusui TOS9311 Multifunctional Safety Analyzer (10 kV model) NEW","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA new model of our latest multifunctional high voltage safety analyzer. A single unit allows for three types of tests: ACW\/DCW\/IR.\u003c\/li\u003e\n\u003cli\u003eMaximum voltage for AC withstand voltage testing: 10 kV\/50 mA\u003c\/li\u003e\n\u003cli\u003eMaximum voltage for DC withstand voltage testing: 5 kV\/20 mA, 10 kV\/10 mA (100 W)\u003c\/li\u003e\n\u003cli\u003eMeasurement range of insulation resistance testing: 0.001 MΩ to 100.0 GΩ (DC-25 V to -1,000 V\/DC+50 V to +10,000 V)\u003c\/li\u003e\n\u003cli\u003eA Withstanding voltage test can also be used for quick NG judgment. The detection sensitivity can be selected from 5 levels.\u003c\/li\u003e\n\u003cli\u003eLAN\/USB\/RS232C included as standard\u003c\/li\u003e\n\u003cli\u003eEasy to read LCD display for real time monitoring during tests. All measurement values and standard outlines displayed in each test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"swrnkkn\"\u003e\u003cstrong\u003eThis product generates high voltage!\u003c\/strong\u003eThe use of this product requires knowledge of electricity.Improper handling or operation of this product can be very dangerous, so be sure to read the instruction manual carefully and use this product properly.\u003c\/p\u003e\n\u003ch3\u003eOutput\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"14\"\u003eAC voltage\u003c\/th\u003e\n\u003cth rowspan=\"3\"\u003eOutput range\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003ctd\u003e0.050 kV to 10.000 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting accuracy\u003c\/th\u003e\n\u003ctd\u003e±(1.2% of setting + 0.02kV) (at no load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eMax. rated load\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003e500 VA（10 kV \/ 50 mA）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eMax. rated current\u003c\/th\u003e\n\u003ctd\u003e50 mA (When the output voltage is 0.5 kV or higher)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eTransformer rating\u003c\/th\u003e\n\u003ctd\u003e500 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eOutput voltage waveform\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*2\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003ctd\u003eSine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDistortion Rate\u003c\/th\u003e\n\u003ctd\u003e2 % or less (When the output voltage is 1.0 kV or more and the pure resistive load is 200 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eCrest factor\u003c\/th\u003e\n\u003ctd\u003e√2 ± 3 %(1500 V or more)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eFrequency\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003ctd\u003e50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eVoltage regulation\u003c\/th\u003e\n\u003ctd\u003e±3 % or less (When changing from maximum rated load to no load.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eShort-circuit current\u003c\/th\u003e\n\u003ctd\u003e100 mA or more (Output voltage 1.0 kV or higher)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eOutput method\u003c\/th\u003e\n\u003ctd\u003ePWM switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"10\"\u003eDC voltage\u003c\/th\u003e\n\u003cth rowspan=\"3\"\u003eOutput range\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003ctd\u003e0.100 kV to 10.000 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting accuracy\u003c\/th\u003e\n\u003ctd\u003e±(1.2 % of setting + 0.02 kV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eMax. rated load\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003e100 W (5 kV\/20 mA, 10 kV\/10 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eMax. rated current\u003c\/th\u003e\n\u003ctd\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eRipple\u003c\/th\u003e\n\u003cth\u003e10 kV no load\u003c\/th\u003e\n\u003ctd\u003e30 Vp-p Typ．\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. rated load\u003c\/th\u003e\n\u003ctd\u003e100 Vp-p Typ．\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eVoltage regulation\u003c\/th\u003e\n\u003ctd\u003e1 % or less (When changing from maximum rated load to no load.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eShort-circuit current\u003c\/th\u003e\n\u003ctd\u003e50 mA（100 mA peak）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eDischarge function\u003c\/th\u003e\n\u003ctd\u003eForced discharge after test completion (Discharge resistance: 125 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\" colspan=\"2\"\u003eStart voltage\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003ctd\u003eThe voltage at the start of the test can be set.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting range\u003c\/th\u003e\n\u003ctd\u003e1 % to 99 % of the test voltage (1% resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eOutput voltage monitor function\u003c\/th\u003e\n\u003ctd\u003eIf the output voltage exceeds ±(10 % of setting + 0.05 kV), the output is turned off, and the protection function is activated.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"ps\"\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhen tests are performed consecutively, output time limit and rest time may become necessary depending on the upper limit setting.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*2\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIf an AC voltage is applied to a capacitive load, the output voltage may rise higher than at no load depending on the load capacitance. Further, waveform distortions may occur if an EUT whose capacitance is dependent on voltage (for example, an EUT that consists of ceramic capacitors) is connected as the load. However, if the test voltage is 1.5 kV, the effect of a capacitance of 1 000 pF or less can be ignored. Because the product’s high-voltage power supply uses the PWM switching method, if the test voltage is 500 V or less, the switching and spike noise proportions are large. The lower the test voltage, the greater the waveform is distorted.\u003c\/p\u003e\n\u003ch3\u003eVoltmeter\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003ctd\u003e0.000 kV to 10.500 kV AC \/ DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±(1.2 % of reading + 5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse\u003c\/th\u003e\n\u003ctd\u003eCan be switched between true rms and mean-value response rms conversion.\u003cbr\u003ePeak-value response in a separate system (the peak-value response is for measuring the dielectric breakdown voltage while rising)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHold function\u003c\/th\u003e\n\u003ctd\u003eThe voltage measurement after a test is finished is held while the pass\/fail judgment is displayed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAmmeter\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range\u003c\/th\u003e\n\u003ctd\u003eAC: 0.00 mA to 55 mA (Current including the active component and reactive component)\u003cbr\u003eDC: 0.00 mA to 22 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±(1 % of reading + 2 μA) (active component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse\u003c\/th\u003e\n\u003ctd\u003eCan be switched between true rms and mean-value response rms conversion.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHold function\u003c\/th\u003e\n\u003ctd\u003eThe current measurement after a test is finished is held while the pass judgment is displayed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOffset cancel function\u003c\/th\u003e\n\u003ctd\u003eCancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across output cables and the like (resistance component only for DC tests). OFF function available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCalibration\u003c\/th\u003e\n\u003ctd\u003eActive component: Calibrated with the rms of a sine wave using a pure resistive\u003cbr\u003eload.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"ps\"\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDuring AC voltage tests, current also flows in the stray capacitance of items such as the test leads and tools.\u003c\/p\u003e\n\u003ch3\u003eJudgment feature\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eUpper limit setting range\u003c\/th\u003e\n\u003ctd\u003eAC: 0.01 mA to 55.00 mA, DC: 0.01 mA to 21.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLower limit setting range\u003c\/th\u003e\n\u003ctd\u003eAC: 0.00 mA to 54.99 mA, DC: 0.00 mA to 20.99 mA, OFF.\u003cbr\u003eSetting 0.00 is equivalent to OFF.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJudgment accuracy\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003e±(1 % of setting + 5 μA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent detection method\u003c\/th\u003e\n\u003ctd\u003eComparison with reference values using the following methods:\u003cbr\u003eCalculating true RMS value \/ Converting the average response to RMS value \/ Measuring the wave height.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse speed (filter)\u003cbr\u003eswitching\u003c\/th\u003e\n\u003ctd\u003eSwitches the current detection response speed (sensitivity) used in UPPER FAIL judgment between five levels in ACW and DCW tests.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"ps\"\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eDuring AC voltage tests, current also flows in the stray capacitance of items such as the test leads and tools.\u003c\/p\u003e\n\u003ch3\u003eTimer function\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage rise time settings range\u003c\/th\u003e\n\u003ctd\u003e0.1 s to 200.0 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage fall time setting time\u003c\/th\u003e\n\u003ctd\u003e0.1 s to 200.0 s, OFF (valid only for determining PASS)\u003cbr\u003eDuring DC withstand voltage testing, the voltage may not fall entirely during the set time due to the internal capacitance and the capacitance of the test object.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTest time setting range\u003c\/th\u003e\n\u003ctd\u003e0.1 s to 1000.0 s, OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJudgment delay (Judge Delay) setting range\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\n\u003c\/th\u003e\n\u003ctd\u003e0.1 s to 100.0 s, AUTO (DCW only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±(100 ppm of setting + 20 ms) (excluding the fall time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"ps\"\u003e\u003cspan class=\"kome\"\u003e*1\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eLess than the sum of the rise time and fall time.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"kome\"\u003e*2\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWhen “Delay Auto” is set to ON, UPPER determination will not be performed until the charging time ends.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-ascii-font-family: Aptos; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Aptos; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi;\"\u003e*The image is for reference only. See product specification for details.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Kikusui","offers":[{"title":"Default Title","offer_id":51100634415351,"sku":"70866","price":9700.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/valuetronics.com\/products\/tos9311-new-kikusui-hipot-new","provider":"ValueTronics","version":"1.0","type":"link"}