{"product_id":"tca-bnc-tektronix-probe-adapter-new","title":"Tektronix TCA-BNC TekConnect-to-TekProbe BNC 50 Ω Adapter","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eTektronix TCA-BNC TekConnect-to-TekProbe BNC 50 Ω Adapter\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eTekConnect interface with one-button release and locking mechanism for quick probe, amplifier, and adapter changes\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eBandwidth from DC to ≥4 GHz up to DC to ≥25 GHz across the series (maximum frequency limited by the host instrument)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eLow-VSWR 50 Ω environment preserved across the 50 Ω adapters (TCA-BNC, TCA-SMA, TCA-N, TCA-292MM)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eConnector options span 75 Ω BNC, TekProbe BNC 50 Ω, SMA, N, and 2.92 mm interfaces\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eTCA75 offers a 75 Ω input with automatic attenuation factor correction for correctly displayed signal magnitudes\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003e2.92 mm adapter is SMA-compatible; locking screw required for full bandwidth performance\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEach adapter includes an instruction manual and Certificate of Compliance and carries a 1-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe TekConnect TCA Series is a family of adapters that connect signals into Tektronix high-performance, real-time oscilloscopes equipped with a TekConnect interface. The TekConnect interface delivers signal fidelity with useful bandpass up to 25 GHz and preserves a low-VSWR 50 Ω environment along with a reliable electrical connection, while a one-button release and locking mechanism allows quick installation and removal of probes, amplifiers, and adapters. The family comprises the TCA75, TCA-BNC, TCA-SMA, TCA-N, and TCA-292MM, each translating the TekConnect interface to a different connector standard with less signal distortion and better performance than traditional connection methods such as BNC to N or BNC to SMA.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eListed applications span signal integrity, jitter, and timing analysis; verification, characterization, and debug of sophisticated designs; and work with high-speed digital devices and circuits. The series is also applied to power supplies and inverters, semiconductor devices, electronic ballasts, industrial and consumer electronics, mobile communications, motor drives, transportation systems, and disk drive analysis. Additional use cases include investigation of transient phenomena, spectral analysis, and video design and development, including HDTV and streaming digital video.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments and accessories we list are equipment we keep on hand rather than source on demand.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe TekConnect TCA Series is a family of adapter systems that expand the functionality of Tektronix high-performance oscilloscopes by moving a signal from one connector environment to another with less signal distortion and better performance than traditional connections such as BNC to N or BNC to SMA. Built on the TekConnect interface — which supports useful bandpass up to 25 GHz and a low-VSWR 50 Ω environment — the series lets an engineer match the oscilloscope's input to the connector standard the device under test requires.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model below links to its own dedicated product page with new-condition pricing. Select the adapter whose connector type and bandwidth tier match your measurement; every page reflects the configuration and condition-matched price for that specific new unit.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe TCA75 is the family's 75 Ω member: it allows a TekConnect oscilloscope to access and measure 75 Ω terminated circuitry, presenting a 75 Ω ±1.5% input with 2.46X ±1.5% attenuation accuracy at DC. Its attenuation factor is automatically corrected so the end user sees correctly displayed signal magnitudes.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe models differ primarily in connector type, input impedance, and bandwidth. The TCA75 provides a 75 Ω BNC input, while the TCA-BNC, TCA-SMA, TCA-N, and TCA-292MM are 50 Ω only, terminating in TekProbe BNC 50 Ω, SMA, N, and 2.92 mm connectors respectively. The TCA-BNC additionally supports Tektronix high-speed active and differential probes through its TekProbe BNC 50 Ω interface.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eTypical (–3 dB) bandwidth rises with connector capability: DC to ≥4 GHz for the TCA75 and TCA-BNC, DC to ≥11 GHz for the TCA-N, DC to ≥18 GHz for the TCA-SMA, and DC to ≥25 GHz for the TCA-292MM, in each case limited by the host instrument. Minimum rise time follows the same ordering, and the 2.92 mm interface — robust and SMA-compatible — reaches the highest frequencies. The comparison table below lists the per-model connector, impedance, bandwidth, and rise-time figures.\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Connector\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMax Bandwidth (–3 dB)\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eInput Impedance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003eTCA-BNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTekProbe BNC 50 Ω\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC to 4 GHz, limited by host instrument\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTCA75\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e75 Ω BNC\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC to 4 GHz (adapter only)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e75 Ω ±1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTCA-SMA\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eSMA 50 Ω\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC to ≥18 GHz, limited by host instrument\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTCA-N\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eN 50 Ω\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC to ≥11 GHz, limited by host instrument\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAccessories Supplied\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eInstruction manual\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eCertificate of Compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eCharacteristic\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eTCA75\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eTCA-BNC\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eTCA-SMA\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eTCA-N\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eTCA-292MM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAttenuation Accuracy at DC\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e2.46X ±1.5%\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eInput Resistance at DC\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e75 Ω ±1.5%\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 Ω\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 Ω\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 Ω\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eBandwidth (–3 dB), Typical\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC to 4 GHz (adapter only)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC to 4 GHz (maximum frequency), limited by host instrument\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC to ≥18 GHz (maximum frequency), limited by host instrument\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC to ≥11 GHz (maximum frequency), limited by host instrument\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC to ≥25 GHz (maximum frequency), limited by host instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRMS Noise\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eVSWR (Return Loss)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRF Insertion Loss (adapter only)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6.05 dB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.25 dB max\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.06×SQRT (F) (GHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.3 dB max\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.04×SQRT (F) (GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRise Time (minimum rise time, limited by host instrument)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u0026lt;50 ps\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e≤100 ps\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e≤22 ps\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e≤36 ps\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e≤16 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum Input Voltage (Derated with frequency)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e≤12 V DC or ≤12 VRMS (2 W max)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to host instrument specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eInputs (Nominal)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 (BNC 75 Ω)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 (TekProbe BNC 50 Ω)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 (SMA 50 Ω)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 (N 50 Ω)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 (2.92 mm 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAdapter Model Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to TekConnect amplifier, adapters, and probes compatibility table\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to TekConnect amplifier, adapters, and probes compatibility table\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to TekConnect amplifier, adapters, and probes compatibility table\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to TekConnect amplifier, adapters, and probes compatibility table\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRefer to TekConnect amplifier, adapters, and probes compatibility table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 year\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 year\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 year\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 year\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cblockquote style=\"background:#FFFDF0; border:1px solid #d4c79a; padding:14px 18px; margin:18px 0; clear:both; border-radius:4px;\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e TCA-292MM: the locking screw must be used to ensure full bandwidth performance.\u003c\/blockquote\u003e\u003cblockquote style=\"background:#FFFDF0; border:1px solid #d4c79a; padding:14px 18px; margin:18px 0; clear:both; border-radius:4px;\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e TCA-292MM: The 2.92 mm connector is compatible with SMA connectors, but the electrical performance will be limited to the bandwidth of the SMA connector.\u003c\/blockquote\u003e\u003cblockquote style=\"background:#FFFDF0; border:1px solid #d4c79a; padding:14px 18px; margin:18px 0; clear:both; border-radius:4px;\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e Firmware version 2.1 or greater is required on all referenced oscilloscopes for use with these TekConnect adapters.\u003c\/blockquote\u003e\u003cblockquote style=\"background:#FFFDF0; border:1px solid #d4c79a; padding:14px 18px; margin:18px 0; clear:both; border-radius:4px;\"\u003eRecommended pairing: use the P6150 9 GHz, 1X\/10X 50 Ω divider probe with the TCA-SMA, as named in the recommended accessories list.\u003c\/blockquote\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.\u003c\/p\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233218109687,"sku":"tektro_tca-bnc_new","price":869.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_tca-bnc-new_bd017850-fca9-4e9d-a41f-991490b2e639.jpg?v=1735333149","url":"https:\/\/valuetronics.com\/products\/tca-bnc-tektronix-probe-adapter-new","provider":"ValueTronics","version":"1.0","type":"link"}