{"product_id":"rto-k17-new-rohdes-unassigned-new","title":"RTO-K17 Rohde \u0026 Schwarz NEW","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor use with RTO2000 series oscilloscopes\u003c\/li\u003e\n\u003cli\u003e16bit max resolution\u003c\/li\u003e\n\u003cli\u003e9.4 ENOB\u003c\/li\u003e\n\u003cli\u003eMore signal details and more precise results with maximum acquisition rate\u003c\/li\u003e\n\u003cli\u003eAll analysis functions available in HD mode\u003c\/li\u003e\n\u003cli\u003eTrigger on smallest signal details in HD mode\u003c\/li\u003e\n\u003cli\u003eEasy to add HD mode to every R\u0026amp;S RTO oscilloscope via software option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12\"\u003e\n\u003cp\u003eThe high definition (HD) mode increases the vertical resolution of the R\u0026amp;S RTE (standard since serial number 300.000) and R\u0026amp;S RTO oscilloscopes to up to 16-bit. Waveforms are sharper and show signal details that would otherwise be masked by noise. Users benefit from even more precise analysis results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row align-items-center py-4\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cstrong\u003eIncreased resolution for precise measurement of small signal amplitudes\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe high definition mode increases the vertical resolution up to 16-bit. This is required to analyze signal details on a signal with high amplitude variations. One example is the characterization of switched-mode power supplies. Here you need to measure smallest signal elements on a several hundred volt signal. A resolution higher than 8-bit is a must for precise measurements in such situations.\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row align-items-center py-4\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cstrong\u003eSelect the bandwidth and gain up to 16-bit vertical resolution\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe HD mode increases the vertical resolution of the R\u0026amp;S RTO and R\u0026amp;S RTE oscilloscopes to up to 16-bit. To achieve this higher resolution, the signal is lowpass filtered after the A\/D converter. The hardware-implemented filter reduces the noise in realtime, thereby increasing the signal-to-noise ratio without any reduction of the update rate.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row align-items-center py-4\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\u003ccenter\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cstrong\u003eThe HD mode uses the full sample rate to avoid aliasing\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe high definition mode offers advantages over high-resolution decimation. You know exactly what signal bandwidth is available due to explicit lowpass filtering, and there are no unexpected aliasing effects. Since the HD mode is not based on decimation, the increase in resolution is not accompanied by a reduction in the sampling rate. When the HD mode is on, the full sampling rate is available, ensuring the best time resolution.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row align-items-center py-4\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cstrong\u003eTrigger on smallest signal details in HD mode\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe increased resolution in high definition mode makes it possible to reveal even the smallest signal details. The unique R\u0026amp;S digital trigger design allows you to trigger on signals with increased resolution. Each of the up to 16-bit samples is checked against the trigger condition and can initiate a trigger. This means that R\u0026amp;S RTE and R\u0026amp;S RTO oscilloscopes are able to trigger on even the smallest signal amplitudes and isolate relevant signal events.\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row align-items-center py-4\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cstrong\u003eHigh acquisition rate and full analysis functionality for fast measurement results\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eSwitching on high definition mode does not compromise measurement speed or functions. Since the lowpass filtering, which improves resolution and noise suppression, is implemented in realtime in the oscilloscope’s ASIC, acquisition and processing rates remain high. The oscilloscope enables smooth operation, and measurement results are available quickly. You can use all analysis tools in high definition mode, including automatic measurements and FFT.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Rohde \u0026 Schwarz","offers":[{"title":"Default Title","offer_id":49595091353847,"sku":"67249","price":2185.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/valuetronics.com\/products\/rto-k17-new-rohdes-unassigned-new","provider":"ValueTronics","version":"1.0","type":"link"}