{"product_id":"pfx2731s-new-kikusui-battery-new","title":"Kikusui PFX2731S Battery Testing System NEW","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003csection id=\"pfx2731s-backtext\"\u003e\n\u003cdiv class=\"grid js-anime container960 is-show\"\u003e\n\u003cdiv class=\"col-12\"\u003e\n\u003cp class=\"tenohira\"\u003eEnables high-rate charge\/discharge tests necessary for enhanced rapid charge\/discharge performance.\u003c\/p\u003e\n\u003cp\u003eThe PFX2731S is a 6 V-20 A 6-channel battery tester that supports high-rate charge\/discharge tests. It is operated with the application software BPChecker4000, which is exclusive to the PFX2731S. As one PC can operate up to 4 units (24 channels), one can construct a multi-channel charge\/discharge system according to the required number of channels.\u003c\/p\u003e\n\u003cp\u003eIn order to safely conduct long-term continuous testing, it also has 2-system independent protection functions for hardware and software, as well as various protection functions such as a connection confirmation function that detects incorrect wiring and integrated capacity protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-6_sm-12\"\u003e\n\u003cul\u003e\n\u003cli\u003e10 ms continuous measurement (at the fastest setting)\u003c\/li\u003e\n\u003cli\u003eSupports single cell evaluation (C-rate can be set)\u003c\/li\u003e\n\u003cli\u003eVarious charge\/discharge modes (9 modes in total)\n\u003cul\u003e\n\u003cli\u003eCharging: CC, CC-CV, CP, CP-CV\u003c\/li\u003e\n\u003cli\u003eDischarging: CC, CC-CV, CP, CP-CV\u003c\/li\u003e\n\u003cli\u003ePattern charge\/discharge (CC(+CV), CP(+CV))\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-6_sm-12\"\u003e\n\u003cul\u003e\n\u003cli\u003eWhen an error is found, a built-in path switch immediately terminates the test.\u003c\/li\u003e\n\u003cli\u003eFour thermostatic chambers (produced by Espec) can be operated synchronously\u003c\/li\u003e\n\u003cli\u003eA T-type thermocouple (optional) can be used to measure temperature.\u003c\/li\u003e\n\u003cli\u003eThe system can be set up by connecting a LAN cable.\u003c\/li\u003e\n\u003cli\u003eEnhanced protection functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"networkfeatures js-anime container1200 is-show\"\u003e\n\u003cdiv class=\"grid hazama\"\u003e\n\u003ch3 class=\"titlehe col-12\"\u003eSystem Configuration\u003c\/h3\u003e\n\u003cdiv class=\"col-6_md-12\"\u003e\n\u003ch4\u003eExample of PFX2731S x 1 unit connected with LAN cable\u003c\/h4\u003e\n\u003cimg src=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/pfx-sys2-en.jpg\" decoding=\"async\" alt=\"Example of PFX2731S x 1 unit connected with LAN cable\" width=\"846\" height=\"800\" class=\"entered litespeed-loaded\"\u003e\n\u003cp\u003eThe PFX2731S combines a control unit, a measurement unit, and a 6-channel 6 V-20 A charge\/discharge unit into a single housing, allowing the creation of a compact charge\/discharge system with up to 24 channels. Continuous data recording of 10 ms is possible for all channels due to the complete isolation and independent measurement functions of each channel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-6_md-12\"\u003e\n\u003ch4\u003eExample of PFX2731S x 4 units and constant temperature chamber x 4 units\u003cbr\u003econnected via LAN cable\u003c\/h4\u003e\n\u003cimg decoding=\"async\" src=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/pfx-sys1-en-3.jpg.webp\" alt=\"Example of PFX2731S x 4 units and constant temperature chamber x 4 units\u0026lt;br\u0026gt;connected via LAN cable”\u0026gt;\u0026lt;p class=\"\u003e*Either LAN or RS485 is used for the connection to the temperature chamber.A separate USB converter is needed for connection to a PC when using the RS485.\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"grid hazama tasai\"\u003e\n\u003ch3 class=\"titlehe col-12\"\u003eThe Charge-Discharge mode for the diverse applications\u003c\/h3\u003e\n\u003cdiv class=\"col-6_md-12\"\u003e\n\u003ch4\u003eCC Charge\u003c\/h4\u003e\n\u003cp\u003eIt is only for constant current charging. It supports -dV detection, and -dT\/dt detection by battery temperature.\u003c\/p\u003e\n\u003ca href=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/juuhoudenn-1-en-3.png\" class=\"venobox vbox-item\"\u003e\u003cimg src=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/juuhoudenn-1-en-3.png.webp\" decoding=\"async\" alt=\"CC Charge\" width=\"1160\" height=\"572\" class=\"entered litespeed-loaded\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-6_md-12\"\u003e\n\u003ch4\u003eCC Discharge\u003c\/h4\u003e\n\u003cp\u003eIt is a general constant current discharge. Termination by capacity (Ah) is another option in addition to voltage and battery temperature.\u003c\/p\u003e\n\u003ca href=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/juuhoudenn-2-en-3.png\" class=\"venobox vbox-item\"\u003e\u003cimg src=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/juuhoudenn-2-en-3.png.webp\" decoding=\"async\" alt=\"CC Discharge\" width=\"1160\" height=\"622\" class=\"entered litespeed-loaded\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-6_md-12\"\u003e\n\u003ch4\u003eCC-CV Charge\u003c\/h4\u003e\n\u003cp\u003eThis charge method switches from constant current to constant voltage automatically. It supports CV time and It current detection.\u003c\/p\u003e\n\u003ca href=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/juuhoudenn-3-en-3.jpg\" class=\"venobox vbox-item\"\u003e\u003cimg src=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/juuhoudenn-3-en-3.jpg.webp\" decoding=\"async\" alt=\"CC-CV Charge\" width=\"1342\" height=\"624\" class=\"entered litespeed-loaded\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-6_md-12\"\u003e\n\u003ch4\u003eCC-CV Discharge\u003c\/h4\u003e\n\u003cp\u003eThis discharge method switches from constant current to constant voltage automatically.\u003cbr\u003eIt supports CV time and It current detection. Since it is capable of a deeper discharge than the CC discharge profile, it can be used for high-precision discharge capacity measurement.\u003c\/p\u003e\n\u003ca href=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/juuhoudenn-4-en-3.jpg\" class=\"venobox vbox-item\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-ascii-font-family: Aptos; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Aptos; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi;\"\u003e*The image is for reference only. See product specification for details.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cimg src=\"https:\/\/kikusui.co.jp\/kiku\/wp-content\/uploads\/2026\/01\/juuhoudenn-4-en-3.jpg.webp\" decoding=\"async\" alt=\"CC-CV Discharge\" width=\"1360\" height=\"738\" class=\"entered litespeed-loaded\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-6_md-12\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-ascii-font-family: Aptos; mso-ascii-theme-font: minor-latin; mso-hansi-font-family: Aptos; mso-hansi-theme-font: minor-latin; mso-bidi-font-family: 'Times New Roman'; mso-bidi-theme-font: minor-bidi;\"\u003e*The image is for reference only. See product specification for details.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Kikusui","offers":[{"title":"Default Title","offer_id":51100660990199,"sku":"70890","price":30300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/Kikusui_PFX2731.jpg?v=1788629790","url":"https:\/\/valuetronics.com\/products\/pfx2731s-new-kikusui-battery-new","provider":"ValueTronics","version":"1.0","type":"link"}