{"product_id":"dp5786al-new-keysig-dc-supply-new","title":"DP5786AL Keysight DC Power Supply NEW","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003eThe DC power supply is the workhorse of the electronics lab — and at the system level, where supplies are stacked into automated test racks and asked to deliver kilowatts of clean, programmable power day after day, the bar rises substantially. The Keysight DP5700 Series is built for exactly that bar: a 68-model family of single-output programmable supplies engineered to maximize rack density without sacrificing the precision, protection, and programmability that production-test, R\u0026amp;D, EV-battery, and motor-controller engineers expect from a Keysight system supply.\u003c\/p\u003e\n\u003cp\u003eThree parameters define every DC power supply purchase — voltage, current, and programmability — and the DP5700 Series is positioned to win on all three. Voltage coverage spans 10 V through 600 V; current capability reaches 500 A; and programmability is standard across the entire series with LAN, USB, and GPIB interfaces plus SCPI command support and IVI.NET drivers. That puts the DP5700 squarely in the system \/ rack DC supply tier — the category that integrates into LabVIEW, Python, MATLAB, and custom test-executive environments, and the tier where the conversation shifts from \"bench instrument\" to \"test-system component.\"\u003c\/p\u003e\n\u003cp\u003eThe series ships in three power classes — 1.5 kW (half-rack 1U), 3.4 kW (full-rack 1U), and 5 kW (full-rack 1U) — and is one of the densest 1U system supply families currently on the market. Compact 1U sizing matters in production environments where every U of rack height is contested by oscilloscopes, DMMs, signal generators, and electronic loads. Stack the DP5700 directly above or below another instrument: front and rear air vents prevent airflow obstruction, which the datasheet calls out explicitly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeries Overview — Verbatim from Datasheet:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall high-density 1U package.\u003c\/li\u003e\n\u003cli\u003eBuilt-in voltage and current measurements.\u003c\/li\u003e\n\u003cli\u003eComprehensive protection from overvoltage and overcurrent.\u003c\/li\u003e\n\u003cli\u003eSingle-phase 100 – 240 VAC universal input for 1.5 kW models.\u003c\/li\u003e\n\u003cli\u003eSingle- and three-phase 200 – 240 VAC, and three-phase 380 – 480 VAC universal input for 3.4 kW and 5 kW models.\u003c\/li\u003e\n\u003cli\u003eStandard LAN, USB, and GPIB interfaces.\u003c\/li\u003e\n\u003cli\u003eFull compliance with the LXI Class C specification.\u003c\/li\u003e\n\u003cli\u003eRemovable SD card option for added security.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe removable SD card option deserves a specific call-out. Test equipment that moves between confidential spaces — DoD facilities, AS9100 production lines, classified R\u0026amp;D labs — has historically required either purpose-built secure instruments or formal sanitization procedures for general-purpose hardware. The DP5700 Series solves this with a removable SD memory that supports equipment sanitization and detailed record-keeping of cleaning processes, including the methods and materials used, to maintain a clear audit trail and ensure accountability. For customers in regulated environments, this single feature changes which instrument is procurable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDC Power Ratings — Verbatim by Power Class:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClass\u003c\/th\u003e\n\u003cth\u003eModels Available\u003c\/th\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003cth\u003eCurrent Range\u003c\/th\u003e\n\u003cth\u003eForm Factor\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1.5 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 single-output programmable models (DP5721A – DP5736A)\u003c\/td\u003e\n\u003ctd\u003e0 – 10 V to 0 – 600 V\u003c\/td\u003e\n\u003ctd\u003e0 – 150 A (max)\u003c\/td\u003e\n\u003ctd\u003e1U half-rack width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3.4 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 single-output programmable models (DP5741AS\/AL\/AH – DP5756AS\/AL\/AH)\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V to 0 to 600 V\u003c\/td\u003e\n\u003ctd\u003e0 to 340 A (max)\u003c\/td\u003e\n\u003ctd\u003e1U full-rack width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 single-output programmable models (DP5761AL\/AH – DP5776AL\/AH)\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V to 0 to 600 V\u003c\/td\u003e\n\u003ctd\u003e0 to 500 A (max)\u003c\/td\u003e\n\u003ctd\u003e1U full-rack width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSelecting the right model starts with the DUT's power profile. Voltage range determines which model family fits the application — 0–30 V general electronics, 0–60 V telecom and automotive ECUs, 0–100 V+ industrial and motor controllers, and 0–600 V for high-voltage analog, battery-stack simulation, and traction inverter test. Current capability must cover both steady-state draw and inrush; at the 500 A end of the DP5700 range, the supplies are sized for high-current battery emulation, motor controller bus simulation, and production burn-in stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScalability — Multiple Units in Parallel and Series:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor applications requiring higher power, the DP5700 Series delivers up to 5 kW per unit.\u003c\/li\u003e\n\u003cli\u003eTo increase output current, up to twelve identical units (3.4 kW and 5 kW models) can be connected in parallel.\u003c\/li\u003e\n\u003cli\u003eTwo units can be connected in series to increase output voltage (see output terminal isolation information).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTwelve 5 kW units in parallel yields 60 kW of single-output programmable DC power — the operating point of large motor controller benches, EV traction-inverter test stations, and high-current battery-pack simulation. The series-connection capability adds another path: pairing two 600 V units in series produces a 1,200 V test source for high-voltage device characterization. The output terminal isolation specification governs both modes: for 10 ~ 100 VDC rated output, no point may be at a greater potential of ±200 VDC from ground; for 150 ~ 600 VDC rated output, no point may be at a greater potential of ±600 VDC from ground.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Architecture:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvertemperature Protection (OTP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— shuts down the output when a fault occurs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection (OCP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— shuts down the output when a fault occurs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection (OVP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— shuts down the output when a fault occurs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUndervoltage Protection (UVP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— prevents voltage adjustment below a set limit. Combined, UVP and OVP create a protection window for sensitive load circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration \u0026amp; Programmability:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComputer Interface (standard):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10\/100 Base-T Ethernet (sockets, VXI-11 protocol, web user interface), USB 2.0 (USB-TMC488 protocol), GPIB (IEEE 488).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLXI version:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.5 LXI Device Specification 2023.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLXI extended functions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLXI IPv4, LXI HiSLIP, LXI VXI VXI-11 Discovery and Identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming language:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSCPI-1999, IEEE 488.2 compliant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrivers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIVI.NET drivers to simplify system development.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommand response time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 10 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSavable states:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog programming input range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 5 V or 0 to 10 V (selectable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog programming accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecified instrument accuracy ±0.2% of rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog programming input impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e150 kΩ (referenced to ground).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor automated test integration, the question to ask before recommending any supply is whether the test infrastructure uses GPIB, USB, or LAN. The DP5700 supports all three as standard. For new automated test builds where LXI hardware triggering matters — sequencing the supply with an oscilloscope acquisition, a relay enable, or an electronic load step — the series' LXI Class C compliance and HiSLIP support deliver the synchronization layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Sourcing Capabilities:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Internal Resistance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— simulates a voltage source with variable series resistance, enabling realistic source impedance emulation for testing devices under more representative operating conditions (e.g., battery behavior).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Arbitrary Generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— creates complex voltage or current waveforms that replicate real-world operating environments. Can be synchronized with other test instruments to support coordinated testing setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Slew Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— manages the rate of voltage change during operation, minimizing voltage overshoot and spikes for sensitive devices requiring carefully managed power ramp-up or ramp-down behavior.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAC Input — Verbatim by Model Group:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Group\u003c\/th\u003e\n\u003cth\u003eConnections\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eMax Phase Current (A RMS)\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1.5 kW — DP57xxA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eL1, L2, PE (1-phase with protective earth)\u003c\/td\u003e\n\u003ctd\u003e100 VAC -15% to 240 VAC +10%\u003c\/td\u003e\n\u003ctd\u003e19.7 A (100 VAC, 1-phase); 17.9 A (110-130 VAC, 1-phase); 10.4 A (190-240 VAC, 1-phase)\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3.4 kW — DP57xxAS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eL1, L2, PE (1-phase with protective earth)\u003c\/td\u003e\n\u003ctd\u003e200 VAC -15% to 240 VAC +10%\u003c\/td\u003e\n\u003ctd\u003e22.6 A\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3.4 kW and 5 kW — DP57xxAL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eL1, L2, L3, PE (3-phase with protective earth; no neutral)\u003c\/td\u003e\n\u003ctd\u003e200 VAC -15% to 240 VAC +10%, line-to-line\u003c\/td\u003e\n\u003ctd\u003e13.1 A\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3.4 kW and 5 kW — DP57xxAH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eL1, L2, L3, PE (3-phase with protective earth; no neutral)\u003c\/td\u003e\n\u003ctd\u003e380 VAC -10% to 480 VAC +10%, line-to-line\u003c\/td\u003e\n\u003ctd\u003e6.5 A\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: Due to the number of different line cords and terminations around the world, the DP5700 power supplies do not come with line cords or terminations. Users will need to supply their own depending on the local laws and codes of the country\/region where the power supply will be used.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Characteristics — Regulatory \u0026amp; Environmental:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eComplies with the European EMC Directive for test and measurement products. Complies with Australian standards and carries the C-Tick mark. This ISM device complies with Canadian ICES-001 \/ Cet appareil ISM est conforme à la norme NMB-001 du Canada.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eComplies with the European Low Voltage Directive and carries the CE-marking. Conforms to US and Canadian safety regulations. Not applicable for IT mains supply systems.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIndoor use, installation category II (for AC input), pollution degree 2.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e0 °C to 40 °C.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e20 to 90% (non-condensing).\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eStorage humidity\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e10 to 90% (non-condensing).\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eUp to 3000 meters, with 2% output current derating for every 100's above 2000 m, and derating maximum ambient temperature by 1 °C per every 100's above 2000 m.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eNon-operating altitude\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eUp to 1,200 m.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e–30 °C to 85 °C.\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp\u003e\u003cstrong\u003eAcoustic Noise Emission:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.5 kW Models\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— At max fan speed: LpA 59.2 dB at Operator Position, LpA 52.0 dB at Bystander Position. At idle: LpA 47.7 dB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.4 kW Models\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— At max fan speed: LpA 58.3 dB at Operator Position, LpA 56.8 dB at Bystander Position. At idle: LpA 50.4 dB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (All units are in millimeters):\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.5 kW Units:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e214.0 ±1.0 mm (W) × 43.9 +0.7\/−0.3 mm (H) × 662.6 ±3.5 mm (D).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.4 kW and 5 kW Units:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e422.9 ±0.10 mm (W) × 43.6 +0.70\/−0.30 mm (H) × 598.2 ±1.50 mm (D).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAccessories:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDP5701A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— 1U half rack — Rack-mount slide kit for 1.5 kW models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN5740A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— 1U full rack — Rack-mount slide kit for 3.4 kW and 5 kW models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDP5705A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Removable SD memory option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKeysight IO Libraries Suite ships with the DP5700 to establish error-free PC-to-instrument connections regardless of vendor.\u003c\/li\u003e\n\u003cli\u003eSCPI-1999, IEEE 488.2 compliant command language.\u003c\/li\u003e\n\u003cli\u003eIVI.NET drivers for system development.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eService \u0026amp; Support:\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThree years of extended warranty.\u003c\/li\u003e\n\u003cli\u003eThree years of KeysightCare technical support — unlimited access to technical experts with committed response times.\u003c\/li\u003e\n\u003cli\u003eKeysightCare Enhanced upgrade extends coverage up to five years and includes a calibration service of choice with prioritized turnaround times (available in select countries).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eIn summary,\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethe Keysight DP5700 Series is a 68-model family of single-output programmable DC power supplies engineered for high-density rack-mount integration in automated test, R\u0026amp;D, EV-battery, and motor-controller applications. The series spans 1.5 kW, 3.4 kW, and 5 kW power classes — all in 1U chassis — with voltage coverage from 10 V to 600 V and current capability to 500 A, plus standard LAN, USB, GPIB, and LXI Class C connectivity. Programmable internal resistance, a built-in arbitrary generator, adjustable slew control, and removable-SD-card security make it the right system supply for production test, classified environments, and automated test integration where rack density and software control are non-negotiable.\u003c\/p\u003e\n\u003ch2\u003eWhat is the Keysight DP5700 Series used for?\u003c\/h2\u003e\n\u003cp\u003eThe DP5700 Series is used in automated test systems, production-test lines, EV and battery-pack characterization, motor-controller test, and any laboratory or production environment that requires high-density programmable DC power with software control. It delivers up to 5 kW per 1U unit and scales to 60 kW via twelve-unit parallel operation, addressing applications from precision low-voltage device characterization through 600 V high-voltage stack simulation.\u003c\/p\u003e\n\u003cp\u003eProduction-test integrators choose this series because it consolidates voltage, current, measurement, and protection into a single 1U slot — freeing rack space for other instruments. R\u0026amp;D engineers choose it for the programmable internal resistance and arbitrary generator, which simulate real-world source impedance and dynamic load conditions during device characterization.\u003c\/p\u003e\n\u003ch3\u003eDoes the DP5700 work with LabVIEW, Python, and MATLAB?\u003c\/h3\u003e\n\u003cp\u003eYes. The DP5700 Series supports SCPI-1999 and IEEE 488.2 compliant commands and ships with IVI.NET drivers, making it directly compatible with LabVIEW, Python, MATLAB, TestStand, and any test executive that supports standard test-and-measurement instrument drivers. Standard LAN, USB 2.0 (USB-TMC488 protocol), and GPIB (IEEE 488) interfaces are included on every model — no interface option to specify at order.\u003c\/p\u003e\n\u003cp\u003eFull LXI Class C compliance — including LXI HiSLIP and LXI VXI VXI-11 Discovery and Identification per the 1.5 LXI Device Specification 2023 — adds hardware-triggered synchronization across networked instruments, which is the standard requirement for new automated test builds in 2026.\u003c\/p\u003e\n\u003ch3\u003eHow dense is the DP5700 compared to a conventional rack supply?\u003c\/h3\u003e\n\u003cp\u003eThe DP5700 delivers up to 5 kW in a single 1U full-rack chassis — substantially denser than conventional 2U or 3U system supplies at the same power level. The 1.5 kW models occupy only a 1U half-rack slot, which means two units fit side-by-side in a single 1U rack space for 3 kW total, with front and rear air vents that allow direct vertical stacking without airflow obstruction.\u003c\/p\u003e\n\u003cp\u003eCombined with up to twelve-unit parallel scaling on 3.4 kW and 5 kW models, a single rack can deliver 60 kW of programmable DC power — a footprint advantage that materially affects test-cell capacity planning.\u003c\/p\u003e\n\u003ch2\u003eFactual Grounding — Hard Numbers Buyers Quote\u003c\/h2\u003e\n\u003cp\u003eThe DP5700 Series operates over 0 °C to 40 °C, 20–90% relative humidity (non-condensing), at altitudes up to 3,000 m with derating. Command response time is under 10 ms, recovery time is 1 ms on 1.5 kW and 3.4 kW models (load change 10%–90% \/ 90%–10%), and the analog programming input has 150 kΩ input impedance with ±0.2% of rating accuracy.\u003c\/p\u003e\n\u003cp\u003eFor high-power production-test environments, audible noise matters: 1.5 kW models measure LpA 59.2 dB at the operator position at max fan speed and LpA 47.7 dB at idle; 3.4 kW models measure LpA 58.3 dB and LpA 50.4 dB respectively. These are below the OSHA 85 dB action level — relevant for 8-hour test-floor operator exposure compliance.\u003c\/p\u003e\n\u003ch2\u003eStandards \u0026amp; Compliance Alignment\u003c\/h2\u003e\n\u003cp\u003eThe DP5700 Series complies with the European EMC Directive, the European Low Voltage Directive (CE-marking), US and Canadian safety regulations, Australian standards (C-Tick mark), and Canadian ICES-001 for ISM devices. The programming layer aligns with the LXI Consortium's 1.5 LXI Device Specification 2023, the SCPI Consortium's SCPI-1999, and IEEE 488.2 — the three standards that define interoperable test-and-measurement automation.\u003c\/p\u003e\n\u003cp\u003eKeysight's instrument heritage traces to Hewlett-Packard's HP 6000 series, HP 721x, and HP E36xx lines — the lineage that established the modern programmable DC power supply category. Customers integrating into existing Keysight-based test architectures retain interface, command-set, and software-stack compatibility throughout the DP5700 family.\u003c\/p\u003e\n\u003ch2\u003eHow the DP5700 Compares to a Standard Industry Baseline\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDensity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 kW in 1U full-rack vs. a typical 5 kW supply in 2U or 3U — recovers 1–2U per channel in a production rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard LAN + USB + GPIB on every model vs. industry-typical \"USB standard, GPIB optional\" — no interface upgrade SKU to manage at order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 12 units in parallel (3.4 kW and 5 kW models) for up to 60 kW vs. typical 2–4 unit parallel limits on competing system supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemovable SD card option (DP5705A) standard across the line — most competing system supplies offer this only on dedicated secure-variant SKUs at premium pricing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSourcing capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable internal resistance + built-in arbitrary generator + adjustable slew control — features typically requiring an external SMU or arbitrary source on competing supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBuyer Decision Framework — The Three Questions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DP5700 covers 0–10 V through 0–600 V across 68 models — confirm the maximum, not the nominal, voltage the DUT requires, including any headroom for transient overshoot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent (and inrush):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 500 A on 5 kW models. Confirm steady-state draw\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eand\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003estartup inrush; capacitor charging on a DUT can pull 3–5× steady-state for tens to hundreds of milliseconds. Voltage × Current = Watts; size to peak, not average.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammability \u0026amp; interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard LAN, USB, GPIB, LXI Class C on every DP5700 model. Confirm the test-system software stack (LabVIEW \/ Python \/ MATLAB \/ TestStand) and existing infrastructure interface — then specify the DP5700 model whose voltage and current match the DUT envelope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003e*The image is for reference only. See product specification for details.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Keysight Technologies","offers":[{"title":"Default Title","offer_id":50748671066359,"sku":"70228","price":15247.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/KEYSIGHT_DP5700.jpg?v=1780768127","url":"https:\/\/valuetronics.com\/products\/dp5786al-new-keysig-dc-supply-new","provider":"ValueTronics","version":"1.0","type":"link"}