{"title":"Tektronix 2 Series MSO","description":"\u003cp\u003eMaximize your workspace without sacrificing performance with our ultra-compact, handheld portable oscilloscope. Just 1.5 inches thick and weighing under 4 pounds, the 2 Series MSO combines the convenience of a tablet with the powerful capabilities of a real-time touchscreen oscilloscope. Whether you're on the benchtop, in the classroom, or in the field, take it anywhere your measurement tasks demand.\u003c\/p\u003e","products":[{"product_id":"mso22-2-bw-200-tektronix-mixed-signal-oscilloscope-new","title":"MSO22 2-BW-200 Tektronix Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e200 MHz\u003c\/strong\u003e analog bandwidth on the MSO22 configuration with \u003cstrong\u003e2 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO22 configured at 200 MHz is a 2-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO22 (200 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO22 at 200 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 2 analog channels and 200 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 200 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 200 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 40 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO22 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO22 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (2 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO22 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233091297527,"sku":"tektro_mso22 2-bw-200_new","price":3600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso22.jpg?v=1735322869"},{"product_id":"mso22-2-bw-100-tektronix-mixed-signal-oscilloscope-new","title":"MSO22 2-BW-100 Tektronix Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e100 MHz\u003c\/strong\u003e analog bandwidth on the MSO22 configuration with \u003cstrong\u003e2 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO22 configured at 100 MHz is a 2-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO22 (100 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO22 at 100 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 2 analog channels and 100 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 100 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 100 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 20 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO22 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO22 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (2 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO22 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233074946295,"sku":"tektro_mso22 2-bw-100_new","price":2570.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso22_7222e2de-a46d-4857-b38b-0ad5bf09d509.jpg?v=1735322875"},{"product_id":"mso22-2-bw-350-tektronix-mixed-signal-oscilloscope-new","title":"MSO22 2-BW-350 Tektronix Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e350 MHz\u003c\/strong\u003e analog bandwidth on the MSO22 configuration with \u003cstrong\u003e2 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO22 configured at 350 MHz is a 2-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO22 (350 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO22 at 350 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 2 analog channels and 350 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 350 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 350 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 70 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO22 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO22 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (2 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO22 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233082810615,"sku":"tektro_mso22 2-bw-350_new","price":7480.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso22_e106a10c-7e85-4c36-a3a2-0355f606e76f.jpg?v=1735322880"},{"product_id":"mso24-2-bw-70-tektronix-mixed-signal-oscilloscope-new","title":"MSO24 2-BW-70 Tektronix Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e70 MHz\u003c\/strong\u003e analog bandwidth on the MSO24 configuration with \u003cstrong\u003e4 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO24 configured at 70 MHz is a 4-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO24 (70 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO24 at 70 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 4 analog channels and 70 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 70 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 70 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 14 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO24 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO24 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (4 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO24 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233076879607,"sku":"tektro_mso24 2-bw-70_new","price":2954.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso24.jpg?v=1735322909"},{"product_id":"mso24-2-bw-350-tektronix-mixed-signal-oscilloscope-new","title":"MSO24 2-BW-350 Tektronix Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e350 MHz\u003c\/strong\u003e analog bandwidth on the MSO24 configuration with \u003cstrong\u003e4 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO24 configured at 350 MHz is a 4-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO24 (350 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO24 at 350 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 4 analog channels and 350 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 350 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 350 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 70 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO24 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO24 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (4 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO24 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233074225399,"sku":"tektro_mso24 2-bw-350_new","price":7980.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso24_23a9e0d6-d2dd-428b-b1ba-9fe987fa2ee7.jpg?v=1735322936"},{"product_id":"mso24-2-bw-500-tektronix-mixed-signal-oscilloscope-new","title":"MSO24 2-BW-500 Tektronix Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e500 MHz\u003c\/strong\u003e analog bandwidth on the MSO24 configuration with \u003cstrong\u003e4 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO24 configured at 500 MHz is a 4-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO24 (500 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO24 at 500 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 4 analog channels and 500 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 500 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 500 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 100 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO24 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO24 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (4 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO24 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233082908919,"sku":"tektro_mso24 2-bw-500_new","price":12100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso24_013abc41-7784-4f82-bbb3-3a9feda211df.jpg?v=1735322945"},{"product_id":"mso22-2-bw-500-tektronix-mixed-signal-oscilloscope-new","title":"MSO22 2-BW-500 Tektronix Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e500 MHz\u003c\/strong\u003e analog bandwidth on the MSO22 configuration with \u003cstrong\u003e2 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO22 configured at 500 MHz is a 2-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO22 (500 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO22 at 500 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 2 analog channels and 500 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 500 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 500 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 100 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO22 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO22 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (2 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO22 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233076420855,"sku":"tektro_mso22 2-bw-500_new","price":10200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso22_7ba2a912-00f9-44fc-bc6a-63a90f6886bd.jpg?v=1735322978"},{"product_id":"mso24-2-bw-100-tektronix-mixed-signal-oscilloscope-new","title":"MSO24 2-BW-100 Tektronix Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e100 MHz\u003c\/strong\u003e analog bandwidth on the MSO24 configuration with \u003cstrong\u003e4 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO24 configured at 100 MHz is a 4-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO24 (100 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO24 at 100 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 4 analog channels and 100 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 100 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 100 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 20 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO24 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO24 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (4 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO24 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233124851959,"sku":"tektro_mso24 2-bw-100_new","price":3422.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso24_838fda8d-47d5-494d-b9d0-d6dec32496d2.jpg?v=1735322986"},{"product_id":"mso22-2-bw-70-tektronix-mixed-signal-oscilloscope-new","title":"MSO22 2-BW-70 Tektronix Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e70 MHz\u003c\/strong\u003e analog bandwidth on the MSO22 configuration with \u003cstrong\u003e2 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO22 configured at 70 MHz is a 2-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO22 (70 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO22 at 70 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 2 analog channels and 70 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 70 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 70 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 14 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO22 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO22 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (2 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO22 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233076682999,"sku":"tektro_mso22 2-bw-70_new","price":2060.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso22_5295fef2-4eb1-43f4-8604-c744a14f81a7.jpg?v=1735323050"},{"product_id":"mso24-2-bw-200-tektronix-mixed-signal-oscilloscope-new","title":"Tektronix MSO24 2-BW-200 Mixed Signal Oscilloscope New","description":"\u003cdiv class=\"vt-product-body\" style=\"text-align:left;font-family:Arial,Helvetica,sans-serif;line-height:1.6;font-size:16px;color:#1a1a1a;max-width:1100px;\"\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:18px 22px;margin:0 0 22px 0;clear:both;border-radius:4px;\"\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#7a5f1a;margin:0 0 12px 0;font-weight:700;\"\u003eKey Features at a Glance\u003c\/h3\u003e\n\u003cul style=\"list-style:disc;margin:0 0 16px 0;padding-left:28px;clear:both;\"\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e200 MHz\u003c\/strong\u003e analog bandwidth on the MSO24 configuration with \u003cstrong\u003e4 analog channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e2.5 GS\/s\u003c\/strong\u003e half-channel sample rate (1.25 GS\/s all channels interleaved).\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10 M points\u003c\/strong\u003e record length per channel for extended event capture.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003e\n\u003cstrong\u003e10.1-inch capacitive multi-touch WXGA\u003c\/strong\u003e (1280 × 800) color display.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eVertical resolution: \u003cstrong\u003e8-bit ADC\u003c\/strong\u003e, with up to 16 bits in high-resolution mode.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eStandard advanced triggers: edge, pulse width, runt, timeout, logic, setup \u0026amp; hold, rise\/fall time, parallel bus.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eCompact \u003cstrong\u003e~1.5-inch-thick\u003c\/strong\u003e form factor; optional battery pack with two slots and hot-swap for field use.\u003c\/li\u003e\n\u003cli style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 6px 0;list-style:disc;display:list-item;\"\u003eConnectivity: USB 2.0 host, two USB 2.0 device ports, 10\/100 Mb\/s Ethernet (LAN); VESA 100 × 100 mount and Kensington lock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eIn summary, the Tektronix MSO24 configured at 200 MHz is a 4-analog-channel mixed signal oscilloscope from the Tektronix 2 Series MSO family, designed as a compact, portable instrument that works on the bench, in the field with the optional battery pack, or rack-mounted using the VESA 100 mm interface. It pairs a 10.1-inch capacitive multi-touch WXGA display with a streamlined front panel of color-coded LED-ring knobs, and shares the user interface and SCPI command set of the Tektronix 3\/4\/5\/6 Series oscilloscopes.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eWhat is the MSO24 (200 MHz) used for?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe MSO24 at 200 MHz is used for daily electronics debug, embedded system development, serial-bus protocol decode, mixed-signal capture across up to 16 optional digital inputs, and field measurements where AC power is not available. With 4 analog channels and 200 MHz, it covers general debug, low- to mid-frequency digital design, and power electronics work; the higher-bandwidth members of the family (up to 500 MHz) address faster digital edges and tighter rise-time requirements.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHow does 200 MHz fit into the design workflow?\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eBy the 5× bandwidth-to-signal rule that Tektronix and the broader oscilloscope industry use for accurate waveform reconstruction, 200 MHz of analog bandwidth is matched to signals with fundamentals up to roughly 40 MHz. The 2.5 GS\/s half-channel sample rate (10× oversampling at 250 MHz, 5× at 500 MHz) provides ample margin for sin(x)\/x waveform reconstruction within the bandwidth limit. The 10 M points per-channel record length supports long captures at full sample rate — useful for protocol traces, glitch hunts, and capturing rarely occurring events with the Act-on-Event automation.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eOn the measurement side, the MSO24 provides 36 automated measurements with an unlimited number of measurement badges, statistics (mean, standard deviation, max, min, population), gating (screen, cursors, logic, search, time), basic and advanced waveform math (including arbitrary equation editing), and FFT with eight window functions (Hanning, rectangular, Hamming, Blackman-Harris, flattop2, gaussian, kaiser-bessel, and tekexp). Input impedance is 1 MΩ ± 1% with 14 pF ± 3 pF at the BNC, dropping to \u0026lt; 12 pF at the TPP0200 probe tip and \u0026lt; 8 pF at the P6139B probe tip. Maximum input voltage is 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO platform is built by Tektronix, the most recognized oscilloscope brand in the global electronics industry. The instrument is CE marked for the European Union, UL approved for the USA and Canada, and RoHS compliant. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. The MSO24 ships with a calibration certificate documenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration, and is backed by a one-year standard warranty.\u003c\/p\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003eAccessories Supplied\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTPP0200 passive voltage probe\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e200 MHz, 10:1 attenuation, BNC interface — one per analog channel (4 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstrument stand\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAdjustable rear stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInstallation and safety manual\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTranslated in English, Japanese, and Simplified Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEmbedded help\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eIntegrated on-instrument help system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eExternal power supply\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A AC adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDocumenting traceability to National Metrology Institute(s) and ISO 9001 \/ ISO 17025 quality system registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne-year standard, covering all parts and labor on the instrument; one-year on included probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"display:block;clear:both;text-align:left;font-size:22px;color:#0a3d62;margin:28px 0 12px 0;padding:0 0 6px 0;border-bottom:2px solid #D4C28A;font-weight:700;\"\u003e2 Series MSO Core Capabilities\u003c\/h2\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe 2 Series MSO is a compact, portable, optionally battery-operated mixed signal oscilloscope. It shares a user interface, programmatic command set, and analysis feature set with the 3 \/ 4 \/ 5 \/ 6 Series Tektronix oscilloscopes. A compatibility mode emulates the SCPI of the legacy TDS2000, TBS1000, and MSO\/DPO2000 families — useful when replacing an older Tektronix scope in an existing automated test system.\u003c\/p\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eStacked display mode gives each waveform its own graticule slice across the full ADC range, eliminating the overlap-versus-accuracy tradeoff of a single graticule. Bus waveforms time-correlate decoded serial packets with all displayed signals, and a bus decode results table lists every packet in the acquisition with columns per protocol component.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eModel Overview — 2 Series MSO\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAnalog Channels\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eAvailable Bandwidths\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eMax Sample Rate\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eRecord Length\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDigital Channels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO22\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMSO24\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e70 \/ 100 \/ 200 \/ 350 \/ 500 MHz\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2.5 GS\/s half \/ 1.25 GS\/s all\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 M points\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e16 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eVertical System — Analog Channels\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eBandwidth limits (limited by instrument BW)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e20 MHz, 70 MHz, 100 MHz, 200 MHz, 350 MHz, 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC, DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — BNC\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 MΩ ± 1%, 14 pF ± 3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — TPP0200 probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 12 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput impedance — P6139B probe tip\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10 MΩ, \u0026lt; 8 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eInput sensitivity range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1 mV\/div to 10 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e8 bit (up to 16 bit in high-resolution mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II with peaks \u0026lt; ±425 V (derated above 4.5 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDC gain accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±3%, derated 0.10%\/°C above 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100:1 at ≤100 MHz; 30:1 above 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOffset range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±1 V (1–63.8 mV\/div); ±10 V (63.9–999.5 mV\/div); ±100 V (1–10 V\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003e\u003cem\u003eNote:\u003c\/em\u003e per the manufacturer datasheet, 500 MHz bandwidth is guaranteed from 4 mV\/div to 10 V\/div on 500-MHz configurations.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eHorizontal System and Trigger\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e2 ns\/div to 1000 s\/div (all channels); 1 ns\/div to 1000 s\/div (half channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base delay range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−10 divisions to 5000 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eChannel-to-channel deskew range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e−95 ns to +95 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTime base accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e±25 ppm over any ≥1 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger modes\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAuto, Normal, Single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger holdoff range\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 s to 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger types (standard)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEdge, Pulse Width, Runt, Timeout, Logic, Setup \u0026amp; Hold, Rise\/Fall Time, Parallel Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger sensitivity (edge, DC coupled)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAnalog input: the greater of 6 mV or 0.8 div; Aux In: 500 mVpp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTrigger level ranges\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAny input channel: ±5 divisions from center of screen; Aux In: ±8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSerial Protocol Triggering and Analysis (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eWith the 2-SERIAL or 2-ULTIMATE option, the MSO24 supports trigger, decode, and analysis on I²C (to 10 Mb\/s), SPI (to 20 Mb\/s), RS-232\/422\/485\/UART (to 15 Mb\/s), CAN (to 1 Mb\/s), CAN FD, LIN (to 1 Mb\/s, with wakeup\/sleep frames), and SENT.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eArbitrary Function Generator (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-SOURCE (or 2-ULTIMATE) bundle enables a built-in 50 MHz arbitrary function generator multiplexed onto the AFG\/Aux Out BNC. Waveform types: Arbitrary (128k record), Sine (to 50 MHz), Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential rise\/fall, Sin(x)\/x, Random Noise, Haversine, and Cardiac. DC offset range is ±2.5 V into Hi-Z and ±1.25 V into 50 Ω.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eDisplay, I\/O, and Connectivity\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eInterface\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e10.1-inch LCD capacitive multi-touch, 1280 × 800 (WXGA); Overlay or Stacked display modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUSB\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eTwo USB 2.0 host ports; one USB device port (USBTMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOne port, 10\/100 Mb\/s (and 1000 Mbps in full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAux Out \/ Aux In\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eFront-panel BNC (multiplexed with AFG out); Aux In 300 V\u003csub\u003eRMS\u003c\/sub\u003e CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eProbe compensation\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 to 2.5 V at 1 kHz, source impedance 1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eSecurity \/ mounting \/ ground\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eKensington-style lock; VESA MIS-D 100 mm × 100 mm; ground lug for battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBattery Pack (optional)\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eThe optional 2-BP battery pack provides two battery slots with hot-swap. Typical usage with dual TEKBAT-01 (Li-Ion, 14.52 V\u003csub\u003eDC\u003c\/sub\u003e, 6700 mAh nominal) is up to 8 hours; single-battery is up to 4 hours. Batteries charge from AC power on the instrument or from the standalone TEKCHG-01 external charger. Charge: 0 to +45 °C; discharge: −20 to +60 °C.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003ePhysical, Power, and Environmental\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;clear:both;margin:0 0 18px 0;font-size:15px;line-height:1.5;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align:left;vertical-align:top;background-color:#F0F4F8;color:#0a3d62;border:1px solid #C8D2DD;padding:8px 10px;font-weight:700;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm (8.26 in), Width 344 mm (13.54 in), Depth 40.4 mm (1.59 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eDimensions (with battery pack)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eHeight 210 mm, Width 344 mm, Depth 78 mm (3.07 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (instrument only)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e1.8 kg (4 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eWeight (with one \/ two batteries)\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e3.2 kg \/ 3.6 kg (7 \/ 8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRackmount configuration\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5U (with optional 2-RK rack mount kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eLine power\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e100 to 240 V ±10% at 50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eAC adapter output\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e24 V DC, 2.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e60 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e0 °C to +50 °C (+32 °F to 120 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003e5% to 90% RH at up to +30 °C; 5% to 60% RH above +30 °C up to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eUp to 3,000 meters (9,842 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eRegulatory\u003c\/td\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;border:1px solid #C8D2DD;padding:8px 10px;\"\u003eCE marked (EU); UL approved (USA, Canada); RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eSoftware, Collaboration, and Remote Control\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eNative integration with TekDrive enables save and recall of waveforms, setups, and screenshots directly to a shared cloud workspace. VNC supports remote viewing and control over a network connection. An IVI driver supports LabVIEW, LabWindows\/CVI, Microsoft .NET, MATLAB, and Python \/ C via VISA. TekScope PC analysis software extends offline analysis to saved data.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eCompatible Probes and Accessories\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003ePassive voltage probes: TPP0100, TPP0200, P2221, P5050B, P6139B, P6101B, P3010, THP0301. Current probes: TCPA300 amplifier with TCP312A \/ TCP305A \/ TCP303 heads; TCPA400 with TCP404XL; TCP2020; A622; P6021A; P6022; TRCP3000; TRCP0600; TRCP0300; CT1; CT2; CT6. High-voltage single-ended probes: P5100A, P6015A, P5122, P5150. High-voltage differential: P5200A (50 MHz, 50:1\/500:1). Digital: P6316 (16-channel for MSO functionality). Other: 2-BP battery pack, TEKBAT-01 spare battery, TEKCHG-01 standalone charger, 2-RK rack-mount kit, 2-PC carrying bag, 2-HC hard case, and 119-9725-00 additional AC\/DC power supply.\u003c\/p\u003e\n\u003ch3 style=\"display:block;clear:both;text-align:left;font-size:18px;color:#0a3d62;margin:22px 0 10px 0;font-weight:700;\"\u003eBandwidth and Functionality Upgrades\u003c\/h3\u003e\n\u003cp style=\"text-align:left;font-size:16px;line-height:1.6;margin:0 0 14px 0;color:#1a1a1a;\"\u003eAnalog bandwidth is field-upgradable via license keys on MSO22 and MSO24 (e.g., SUP2-BW70T500-2 takes a 2-channel from 70 MHz to 500 MHz). Functionality bundles: 2-SOURCE (AFG), 2-SERIAL (I²C, SPI, UART, CAN, CAN-FD, SENT, LIN trigger\/decode\/analysis), and 2-ULTIMATE (2-SOURCE + 2-SERIAL). TekScope and TekDrive software subscriptions extend collaboration and offline analysis.\u003c\/p\u003e\n\u003cdiv style=\"background-color:#FFFDF0;border:1px solid #D4C28A;padding:14px 18px;margin:18px 0;clear:both;border-radius:4px;font-size:15px;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 6px 0;font-weight:700;color:#7a5f1a;text-align:left;\"\u003eImportant Note — AFG \/ Aux Out Multiplexing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eThe arbitrary function generator output is multiplexed with the front-panel Aux Out BNC. When the AFG is active, the Aux Out trigger-related signal is not simultaneously available. Plan accordingly for setups that depend on both signals at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align:left;font-size:13px;line-height:1.5;color:#666;margin:30px 0 6px 0;font-style:italic;border-top:1px solid #ddd;padding-top:12px;\"\u003eThis webpage was written by a human with an A.I. “Intern,” which may contain errors. Please review the Manufacturer’s Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tektronix","offers":[{"title":"Default Title","offer_id":49233080910071,"sku":"tektro_mso24 2-bw-200_new","price":3808.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/tektro_mso24_26308fb9-482f-41c4-9495-39efedd02266.jpg?v=1735323065"}],"url":"https:\/\/valuetronics.com\/collections\/tektronix-2seriesmso.oembed","provider":"ValueTronics","version":"1.0","type":"link"}