{"title":"DC Power Supplies","description":"\u003cp\u003eA direct current (DC) power supply gives electric energy of fixed polarity. DC power sources can provide either positive or negative electric energy. A DC power supply takes energy from a power input and gives it to a power output. Input can come from batteries, generators, fuel cells, solar power converters, or alternators. The DC power source harnesses the energy and gives it to an electrical load. You can power a DC supply with a DC or alternate current (AC) source.\u003c\/p\u003e\n\n\u003cp\u003eValueTronics buys and sells DC power supplies from top industry brands, such as BK Precision, Instek, Sorensen, and dozens more. A DC supply powers many types of test equipment.\u003c\/p\u003e","products":[{"product_id":"6012a-agilent-dc-power-supply-used","title":"6012A Agilent DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 0 to 60V\u003c\/li\u003e\n\u003cli\u003eCurrent: 0 to 50A\u003c\/li\u003e\n\u003cli\u003ePower: 1000 Watts\u003c\/li\u003e\n\u003cli\u003eAutoranging output\u003c\/li\u003e\n\u003cli\u003eHigh efficiency, compact and lightweight\u003c\/li\u003e\n\u003cli\u003eFast remote programming\u003c\/li\u003e\n\u003cli\u003eDesigned for system applications\u003c\/li\u003e\n\u003cli\u003eTen-turn voltage and current controls\u003c\/li\u003e\n\u003cli\u003eOperating mode status indicators\u003c\/li\u003e\n\u003cli\u003eLarge, easy-to-read voltage and current meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003eAgilent HP 6012A provides maximum output power capability over a wide and continuous range of voltage or current. This function is performed automatically, requiring no range selection by the operator.\u003c\/p\u003e\n\u003cp\u003eThe Agilent 6012A Autoranging Power Supply provides laboratory-grade performance with the high efficiency of switching regulation techniques. Autoranging allow the supply to provide at least 1000 watts output power over a wide range of output voltage and current combinations without the user having to select the proper output range. The output is adjustable throught the entire operating range of 0 to 60 volts and 0 to 50 amperes by 10-turn front-panel controls.\u003c\/p\u003e\n\u003cp\u003eThese single-output supplies can replace multiple units, saving rack space and reducing system cost and complexity.\u003c\/p\u003e\n\u003cp\u003eThis series of DC power supplies take the place of multiple power supplies on your test bench by providing maximum power at a variety of operating points. They have ten-turn front panel pots to allow precise local control. These power supplies also may beconnected in auto-parallel or series with their corresponding GPIB unit (6030 Series), as part of a test system.\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231638954231,"sku":"agilen_6012a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231638986999,"sku":"nist_traceable","price":210.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231639019767,"sku":"nist_traceable_data","price":280.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231639052535,"sku":"17025","price":315.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6012a.jpg?v=1735285829"},{"product_id":"6023a-agilent-dc-power-supply-used","title":"6023A Agilent DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 20V\u003c\/li\u003e\n\u003cli\u003eCurrent: 30A\u003c\/li\u003e\n\u003cli\u003ePower: 242W\u003c\/li\u003e\n\u003cli\u003eComplete front panel control\/display\u003c\/li\u003e\n\u003cli\u003eConstant current\/constant voltage protection\u003c\/li\u003e\n\u003cli\u003eRemote programming and sensing\u003c\/li\u003e\n\u003cli\u003eAutoranging output\u003c\/li\u003e\n\u003cli\u003eTen-turn voltage and current controls\u003c\/li\u003e\n\u003cli\u003eAuto-series, auto-parallel operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Agilent HP 6023A is part of the 602x series of autoranging power supplies which provide maximum power over a wide range of voltage and current combinations without having to manually select the proper output range.\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231619260663,"sku":"agilen_6023a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231619293431,"sku":"nist_traceable","price":210.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231619326199,"sku":"nist_traceable_data","price":280.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231619358967,"sku":"17025","price":315.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6023a.jpg?v=1735285834"},{"product_id":"6031a-agilent-dc-power-supply-used","title":"Agilent 6031A 1064 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eAgilent 6031A 1064 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutoranging output delivers maximum power across a wide range of voltage and current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-output configurations covering 0–20 V to 0–500 V and currents up to 120 A across the series\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower levels from 200 W (6033A, 6038A) to 1200 W (6010A, 6012B, 6030A, 6032A) across the family\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eGPIB-equipped models (6030A–6038A) support SCPI commands and VXIPlug\u0026amp;Play drivers for system integration\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUp to 16 GPIB units can be connected through one GPIB address via serial link\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAnalog modulation input accepts 0 to 5 V or 0 to 4 kΩ for external programming of voltage and current\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote sensing supports up to 2 V drop in each lead per datasheet specifications\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEither output terminal can be grounded or floated from chassis ground within rated dc floating voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 Series Autoranging DC Power Supplies are single-output bench and system power supplies designed to deliver maximum power across a variety of operating points rather than at a single fixed voltage and current pair. The autoranging output characteristic allows one supply to cover a wide span of voltage and current combinations, which the datasheet describes as taking the place of multiple fixed-range power supplies on a test bench or in a test system. The non-GPIB 6010A, 6011A, 6012B, and 6015A models use ten-turn front panel pots for precise local control, while the GPIB-equipped 6030A through 6038A models add SCPI command compatibility and VXIPlug\u0026amp;Play drivers for integration into automated test systems.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, these supplies are intended to save rack space by using fewer outputs, reduce cost by using fewer power supplies, and — for the non-GPIB models — provide control with external voltage through the analog modulation input. The GPIB models extend this to system-level applications where the datasheet notes that up to 16 power supplies can be connected through one GPIB address via the serial link, and that the supplies have excellent electrical efficiency making them a good choice for large systems. The non-GPIB units can also be connected in auto-parallel or auto-series with their corresponding GPIB unit (6030 Series) as part of a test system.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test \u0026amp; measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement business as Keysight Technologies. Instruments originally branded HP, then Agilent, and now sold or supported by Keysight share a continuous engineering lineage across all three brand names.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 and 6030 Series Autoranging DC Power Supplies are a related family of single-output supplies sharing the same autoranging output architecture. The non-GPIB 6010A, 6011A, 6012B, and 6015A models provide front-panel control with ten-turn pots and an analog modulation input. The GPIB-equipped 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A models add SCPI command compatibility, VXIPlug\u0026amp;Play drivers, and serial-link networking for automated test system integration.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the family, models are differentiated primarily by voltage range, current range, and maximum power. The 1000 W and 1200 W class supplies (6010A, 6011A, 6012B, 6015A, 6030A, 6031A, 6032A, 6035A) cover voltage ranges from 0–20 V up to 0–500 V depending on the model, while the 200 W class supplies (6033A and 6038A) provide lower-power capability in a half-rack form factor. The 6033A and 6038A also offer the Opt 800 rack-mount kit for two half-rack units side by side.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model linked below has its own dedicated product page with pre-owned-matched pricing, current availability, and complete specifications. Click through to the specific model that matches your application's voltage, current, and power requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe primary differentiator within the family is the GPIB and SCPI capability: the 6030 Series adds remote programming, readback, and the ability to network up to 16 supplies through one GPIB address. The non-GPIB 6000 Series models can be auto-paralleled or auto-seried with their corresponding GPIB units as part of a hybrid test system. The 6030 Series also carries a three-year warranty per the datasheet, compared to a one-year warranty on the non-GPIB models.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eVoltage and current ratings vary significantly across the family. Customers needing high voltage at lower currents should consider the 0–500 V models (6015A, 6035A). Customers needing high current at lower voltages should consider the 0–20 V, 0–120 A models (6011A, 6031A). Customers needing mid-range capability with high power should consider the 0–60 V models (6012B, 6032A, 6038A) or the 0–200 V models (6010A, 6030A).\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMaximum Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6031A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6010A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6011A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6012B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e6031A\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V1, I1\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e20 V, 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V2, I2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 V, 76 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V3, I3\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e7 V, 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.035% + 15 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.25% + 250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage rms (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e8 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage p-p\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Current rms\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.08% + 7 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.4% + 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response time (10% step change)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response level\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC floating voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 100 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 120 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 220 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 240 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e17.2 kg (38 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e22.7 kg (50 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Either output terminal can be grounded or floated from chassis ground within the rated dc floating voltage of ±240 V (6011A, 6012B, 6031A, 6032A, 6033A, 6038A) or ±550 V (6010A, 6015A, 6030A, 6035A).\u003cstrong\u003eImportant:\u003c\/strong\u003e A line cord option must be specified for the 6010A, 6011A, 6012B, 6015A (and for the 6030A-32A and 6035A). See pages 93-98 of the Agilent Power Products Catalog for ordering information.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 908 and Opt 909 rack-mount kits require support rails (e.g., E3663AC for Agilent rack cabinets).\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 100 (87 to 106 Vac line input) derates the power supply output to 75%.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt J01 (stabilization for loads up to 10 Henries) is not available on the 6033A.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231620997367,"sku":"agilen_6031a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231621030135,"sku":"nist_traceable","price":210.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231621062903,"sku":"nist_traceable_data","price":280.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231621128439,"sku":"17025","price":350.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/keysight_agilent_6031a.jpg?v=1735285847"},{"product_id":"1621a-b-k-precision-dc-power-supply-used","title":"1621A B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0-18 V\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-5 A\u003c\/li\u003e\n\u003cli\u003eOutput Power: 90 W\u003c\/li\u003e\n\u003cli\u003eContinuously monitor voltage and current output on two digital meters\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in parallel to double the current output\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in series to double the voltage output\u003c\/li\u003e\n\u003cli\u003eNew compact style\u003c\/li\u003e\n\u003cli\u003eReliable, Durable\u003c\/li\u003e\n\u003cli\u003eOperate continuously at full load without overheating\u003c\/li\u003e\n\u003cli\u003eFully overload protected\u003c\/li\u003e\n\u003cli\u003eCoarse and fine voltage controls\u003c\/li\u003e\n\u003cli\u003eGreat regulation\u003c\/li\u003e\n\u003cli\u003eVery low ripple\u003c\/li\u003e\n\u003cli\u003eConstant voltage or constant current operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Voltage Operation Voltage Regulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLine (120 VAC +10%, -6%): \u0026lt;0.02% + 3 mV\u003c\/li\u003e\n\u003cli\u003eLoad (no load - full load): \u0026lt;0.02% + 3 mV\u003c\/li\u003e\n\u003cli\u003eRecovery Time: \u0026lt;500 ms\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise: \u0026lt;1 mVrms\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: \u0026lt;300 ppm\/°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Current Operation Current Regulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable Current Range: 0-100%\u003c\/li\u003e\n\u003cli\u003eLine (120 VAC +10%, -6%): \u0026lt;0.02% + 3 mA\u003c\/li\u003e\n\u003cli\u003eLoad: \u0026lt;0.02% + 3 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Ripple: \u0026lt;3 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: 3-digit LED\u003c\/li\u003e\n\u003cli\u003eVoltmeter Range: 0-18 V\u003c\/li\u003e\n\u003cli\u003eVoltmeter Accuracy: ±2% + 2 digits\u003c\/li\u003e\n\u003cli\u003eAmmeter Range: 0-9.99 A\u003c\/li\u003e\n\u003cli\u003eAmmeter Accuracy: ±2% +2 digits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload Protection: Current, limiting, reverse polarity, overvoltage, short circuit\u003c\/li\u003e\n\u003cli\u003eAC Input: 120 VAC ±10%, 60 Hz (120\/220\/230\/24C VAC ±10%, 50\/60 Hz version available)\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 220 W\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 32 to 104 °F (0 to 40 °C), \u0026lt;75% R.H.\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: 5 to 158 °F (-15 to +70 °C), \u0026lt;85% R.H.\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 8.07” x 4.53” x 10.63\" (205 x 115 x 270 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision Analog and Digital series are high quality serial control type DC Regulated Power Supplies. These models can be operated at constant voltage or constant current mode whose output can be varied from 0 up to the rated values for respective model.\u003c\/p\u003e\n\u003cp\u003eThe BK Precision 1621A is a compact unit provided with separate voltage and current meter for monitoring the output voltage and current simultaneously. In terms of operability, these units enable high precision, continuous variability via coarse and fine adjust knobs. The BK Precision Analog and Digital series can be connected in parallel with multiple units of the same model set up a “master\/slave” configuration to increase the output current capability. Serial connection of multiple units can be used to increase the output voltage level.\u003c\/p\u003e\n\u003cp\u003eThis family of power supplies provides clean and stable DC output which is most suitable for many areas including laboratory, industrial, field service, hobby, and telecommunication applications.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231621652727,"sku":"bkprec_1621a","price":249.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231621685495,"sku":"nist_traceable","price":342.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231621718263,"sku":"nist_traceable_data","price":359.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231621751031,"sku":"17025","price":402.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1621a.jpg?v=1735285850"},{"product_id":"1550-b-k-precision-dc-power-supply-new","title":"1550 B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1-36 V, 0-3 A Main Isolated Output\u003c\/li\u003e\n\u003cli\u003eUSB Charging port on front panel**USB 1.1 Charging port will not charge products compliant with USB 2.0 only\u003c\/li\u003e\n\u003cli\u003eRear panel security loop\u003c\/li\u003e\n\u003cli\u003eCompact design\u003c\/li\u003e\n\u003cli\u003eOutput On\/Off control\u003c\/li\u003e\n\u003cli\u003eLarge bright easy to read LCD display\u003c\/li\u003e\n\u003cli\u003eConstant voltage and constant current operation\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne Year Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BK Precision 1550 is a compact 108 watt power supply delivering 1-36V and 0-3A from its main isolated output. A unique feature of the 1550 supply is the USB charging port located on the front panel allowing the user to charge a cell phone or MP3 player. Clean power and quiet operation make this power supply ideal for laboratories, work shops, and schools where bench space is limited.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231626797303,"sku":"bkprec_1550_new","price":215.0,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49231626830071,"sku":"nist_traceable","price":292.0,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49231626862839,"sku":"nist_traceable_data","price":306.0,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49231626895607,"sku":"17025","price":341.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1550-new_1.jpg?v=1735285852"},{"product_id":"6015a-agilent-dc-power-supply-used","title":"Agilent 6015A 1050 W Single-Output Autoranging DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eAgilent 6015A 1050 W Single-Output Autoranging DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutoranging output delivers maximum power across a wide range of voltage and current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-output configurations covering 0–20 V to 0–500 V and currents up to 120 A across the series\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower levels from 200 W (6033A, 6038A) to 1200 W (6010A, 6012B, 6030A, 6032A) across the family\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eGPIB-equipped models (6030A–6038A) support SCPI commands and VXIPlug\u0026amp;Play drivers for system integration\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUp to 16 GPIB units can be connected through one GPIB address via serial link\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAnalog modulation input accepts 0 to 5 V or 0 to 4 kΩ for external programming of voltage and current\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote sensing supports up to 2 V drop in each lead per datasheet specifications\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEither output terminal can be grounded or floated from chassis ground within rated dc floating voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 Series Autoranging DC Power Supplies are single-output bench and system power supplies designed to deliver maximum power across a variety of operating points rather than at a single fixed voltage and current pair. The autoranging output characteristic allows one supply to cover a wide span of voltage and current combinations, which the datasheet describes as taking the place of multiple fixed-range power supplies on a test bench or in a test system. The non-GPIB 6010A, 6011A, 6012B, and 6015A models use ten-turn front panel pots for precise local control, while the GPIB-equipped 6030A through 6038A models add SCPI command compatibility and VXIPlug\u0026amp;Play drivers for integration into automated test systems.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, these supplies are intended to save rack space by using fewer outputs, reduce cost by using fewer power supplies, and — for the non-GPIB models — provide control with external voltage through the analog modulation input. The GPIB models extend this to system-level applications where the datasheet notes that up to 16 power supplies can be connected through one GPIB address via the serial link, and that the supplies have excellent electrical efficiency making them a good choice for large systems. The non-GPIB units can also be connected in auto-parallel or auto-series with their corresponding GPIB unit (6030 Series) as part of a test system.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test \u0026amp; measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement business as Keysight Technologies. Instruments originally branded HP, then Agilent, and now sold or supported by Keysight share a continuous engineering lineage across all three brand names.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 and 6030 Series Autoranging DC Power Supplies are a related family of single-output supplies sharing the same autoranging output architecture. The non-GPIB 6010A, 6011A, 6012B, and 6015A models provide front-panel control with ten-turn pots and an analog modulation input. The GPIB-equipped 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A models add SCPI command compatibility, VXIPlug\u0026amp;Play drivers, and serial-link networking for automated test system integration.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the family, models are differentiated primarily by voltage range, current range, and maximum power. The 1000 W and 1200 W class supplies (6010A, 6011A, 6012B, 6015A, 6030A, 6031A, 6032A, 6035A) cover voltage ranges from 0–20 V up to 0–500 V depending on the model, while the 200 W class supplies (6033A and 6038A) provide lower-power capability in a half-rack form factor. The 6033A and 6038A also offer the Opt 800 rack-mount kit for two half-rack units side by side.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model linked below has its own dedicated product page with pre-owned-matched pricing, current availability, and complete specifications. Click through to the specific model that matches your application's voltage, current, and power requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe primary differentiator within the family is the GPIB and SCPI capability: the 6030 Series adds remote programming, readback, and the ability to network up to 16 supplies through one GPIB address. The non-GPIB 6000 Series models can be auto-paralleled or auto-seried with their corresponding GPIB units as part of a hybrid test system. The 6030 Series also carries a three-year warranty per the datasheet, compared to a one-year warranty on the non-GPIB models.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eVoltage and current ratings vary significantly across the family. Customers needing high voltage at lower currents should consider the 0–500 V models (6015A, 6035A). Customers needing high current at lower voltages should consider the 0–20 V, 0–120 A models (6011A, 6031A). Customers needing mid-range capability with high power should consider the 0–60 V models (6012B, 6032A, 6038A) or the 0–200 V models (6010A, 6030A).\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMaximum Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6015A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 500 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 5 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,050 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6010A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6011A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6012B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e6015A\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,050 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V1, I1\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e500 V, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V2, I2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e350 V, 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V3, I3\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e200 V, 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage rms (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage p-p\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e160 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Current rms\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 13 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response time (10% step change)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response level\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e200 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e125 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1.25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC floating voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±550 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 100 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 120 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 220 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 240 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e16.3 kg (36 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e21.8 kg (48 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Either output terminal can be grounded or floated from chassis ground within the rated dc floating voltage of ±240 V (6011A, 6012B, 6031A, 6032A, 6033A, 6038A) or ±550 V (6010A, 6015A, 6030A, 6035A).\u003cstrong\u003eImportant:\u003c\/strong\u003e A line cord option must be specified for the 6010A, 6011A, 6012B, 6015A (and for the 6030A-32A and 6035A). See pages 93-98 of the Agilent Power Products Catalog for ordering information.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 908 and Opt 909 rack-mount kits require support rails (e.g., E3663AC for Agilent rack cabinets).\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 100 (87 to 106 Vac line input) derates the power supply output to 75%.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt J01 (stabilization for loads up to 10 Henries) is not available on the 6033A.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231622177015,"sku":"agilen_6015a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231622209783,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231622242551,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231622275319,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6015a_1.jpg?v=1735285870"},{"product_id":"1611-b-k-precision-dc-power-supply-used","title":"1611 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0 to 50 VDC, coarse and fine adjustment\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0 to 2A, 0 to 0.5A\u003c\/li\u003e\n\u003cli\u003eLaboratory Quality: Excellent regulation, low ripple\u003c\/li\u003e\n\u003cli\u003ePower Requirements: 100\/120\/220\/240 VAC±10%, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Consumption: Approximately 190 Watts or les at full load\u003c\/li\u003e\n\u003cli\u003eProtection: Reverse polarity protection; current limiting\u003c\/li\u003e\n\u003cli\u003eTemperature Range\u003c\/li\u003e\n\u003cli\u003eOperation: 0° to 40° C \u0026lt; 80° RH\u003c\/li\u003e\n\u003cli\u003eStorage: -15 DEG to +70° C \u0026lt; 70° RH\u003c\/li\u003e\n\u003cli\u003eDimensions: 172 x 119 x 305 mm; 6-3\/4 x 4-11\/16 x 12\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Voltage Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Regulation: Line (108-132): ≤ 0.01% + 3mV; Load (no load to full load): ≤ 0.01% + 5 mV\u003c\/li\u003e\n\u003cli\u003eRecovery Time: ≤ 100µs typical\u003c\/li\u003e\n\u003cli\u003eRipple Voltage: RMS ≤1 mV\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient 0° to +40° C: ≤300 PPM\/° C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Current Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable Current Limits: 0% to 100% (0A to 2A)\u003c\/li\u003e\n\u003cli\u003eCurrent Regulation\u003c\/li\u003e\n\u003cli\u003eLine (108-132V): ≤0.2% + 3 mA\u003c\/li\u003e\n\u003cli\u003eLoad: ≤0.2% + 3 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Ripple: ≤3 mA typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eVoltmeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRange: 0 to 52V\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±-2.5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmmeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHi Range: 0 to 2.2A\u003c\/li\u003e\n\u003cli\u003eLo Range: 0 to 0.55A\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 2.5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Voltage or Constant Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003eProvides regulated dc voltage output or regulated dc current output. Crossover is smooth and automatic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Current Ranges\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHI-LO switch selects full output (0-2 A), or one quarter output (0-0.5 A). LO range improves current settability and meter resolution at lower current values. Switch simultaneously selects range of adjustment and corresponding meter scale.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Metering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTwo large, easy-to-read meters continuously monitor output voltage and current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAct as pilot light and identify mode of operation.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePre-Regulator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLimits internal dissipation for higher reliability.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEither polarity may be floated or grounded.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFully adjustable current limiting (from 0% to 100% of maximum output current) protects circuit under test and the power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePrevents damage to power supply from external voltage of reverse polarity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStyling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModern functional styling. Configuration conserves bench space and aids portability. Logical, convenient layout of controls.\u003c\/p\u003e\n\u003cp\u003eThe BK Preclsion Model 1611 DC Power Supply is a high quality general purpose dc power source. The power supply provides 0-50 volts dc output, adjustable with both coarse and fine controls for precise settability. The current output of the Model 1611 is 0-2 amps. Two current ranges, HI and LO, provide excellent current settability and meter resolution. Two large panel-mounted meters continuously monitor the output voltage and current.\u003c\/p\u003e\n\u003cp\u003eThe power supply exhibits excellent regulation and low ripple characteristics. The circuit design incorporates a preregulator, which greatly reduces internal power dissipation at low output voltages. The styling is both attractive and functional. The mechanical configuration conserves bench space and allows for easy portability.\u003c\/p\u003e\n\u003cp\u003eThe instrument may be used in constant voltage or constant current applications. The crossover from constant voltage to constant current modes is smooth and automatic. LED's indicate the \"CV\" (constant voltage) or \"CC\" (constant current) mode of operation. In constant voltage applications, a current limit may be preset. When load variations cause the current to reach the preset limit, the unit then regulates output current rather than output voltage. Current limits are adjustable from 0% to 100% of maximum. In constant current applications, the maximum voltage may be preset.\u003cbr\u003eWhen load variations cause current to drop below the regulated value, the unit reverts to regulated voltage operation at the preset value. Reverse polarity protection prevents accidental damage to the power supply from improper connection to an external voltage, and current limiting protects the equipment being powered, as well as the power supply.\u003c\/p\u003e\n\u003cp\u003eThe output is isolated from chassis and earth ground, which permits full flexibility of connections. When needed, the \u0026lt;+) or (-) polarity may be strapped to ground, or either polarity may be floated to an external voltage. Two supplies may be connected in series as a 0-to-100 volt power source, or two supplies may be connected in parallel, with suitable balancing resistors, for up to twice the output current. The power supply is well suited for a wide variety of electrical and electronics applications, including service shops, engineering labs, production testing, school laboratories, and home use by hobbyists.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231621783799,"sku":"bkprec_1611","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231621816567,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231621849335,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231621882103,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}]},{"product_id":"1685b-b-k-precision-dc-power-supply-new","title":"B\u0026K Precision 1685B 60V\/5A Switching Mode DC Power Supply","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eB\u0026amp;K Precision 1685B 60V\/5A Switching Mode DC Power Supply\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree output configurations across the series: 1–60V\/5A (1685B), 1–36V\/10A (1687B), 1–18V\/20A (1688B)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutomatic CV\/CC crossover operation with overvoltage, overtemperature, and overload protection\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRotary encoder control knobs with dual-action push for coarse and fine voltage\/current setting\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSave up to 3 user-defined voltage and current presets for quick recall via rear-panel switch\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUSB interface plus analog remote control terminal for PC software control or external voltage\/resistor programming\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eExternal timed programming: up to 20 voltage\/current steps, 99 min 59 sec step time, 999 running cycles\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFront panel auxiliary output (5A max) alongside main rear output terminals\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower factor correction \u0026gt;0.95 at optimal load; 81–86% efficiency depending on model and line voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe B\u0026amp;K Precision 1685B Series is a family of laboratory-grade switching mode DC power supplies designed to deliver high current output in a small, lightweight form factor. The series comprises three models that share a common chassis and control architecture while offering different output configurations: the 1685B (1–60V, 0–5A), the 1687B (1–36V, 0–10A), and the 1688B (1–18V, 0–20A). All three models measure 7.9 x 3.5 x 8.2 inches and weigh 5.2 pounds, making them practical for benches where space and portability matter.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThese supplies are positioned for production testing, telecommunications work, R\u0026amp;D benches, electronic field service, and university laboratory environments. The combination of high current output, compact form factor, and remote programming capability suits applications where a controllable DC source is needed but a full-size linear supply would be impractical. Each unit ships with a power cord, instruction manual, application software CD, USB cable, and remote control connector.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eB\u0026amp;K Precision was founded in 1951 in Chicago, Illinois, and is currently headquartered in Yorba Linda, California. The company has operated continuously under the B\u0026amp;K Precision name throughout its history.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe 1685B Series consists of three switching mode DC power supplies that share a common chassis, control interface, and feature set while differing in output voltage and current configuration. The 1685B provides the highest voltage at 60V with 5A current capacity, the 1687B occupies a middle position at 36V\/10A, and the 1688B delivers the highest current at 20A within an 18V range. Voltage × current works out to 300W for the 1685B, 360W for the 1687B, and 360W for the 1688B.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAcross the series, regulation specifications, ripple and noise levels, meter accuracy, switching frequency, transient response, and protection features are identical. The differentiation between the three models is purely in the output range — selection is driven by the voltage and current requirements of the device under test, not by performance tier.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model in the 1685B Series is offered on its own product page with new pricing matched to the specific configuration. The links below route to the dedicated page for each model, where current availability, accessories included, and any condition notes specific to that unit are documented.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe most important spec to match when choosing among the three models is the combination of voltage and current the DUT requires. The 1685B reaches 60V but is limited to 5A — appropriate for higher-voltage, lower-current devices. The 1688B reaches only 18V but delivers up to 20A — appropriate for lower-voltage, higher-current devices such as automotive electronics and certain RF amplifier supplies. The 1687B sits between them with a balance of 36V at 10A that suits a wider range of general-purpose bench applications.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eFull-load input current also varies slightly with model and line voltage. At 100 VAC, the 1685B draws 3.7A, while both the 1687B and 1688B draw 4.6A. At 230 VAC, the 1685B draws 1.7A and the 1687B\/1688B both draw 2.1A. Efficiency at 230 VAC is 86% for the 1685B and 1687B, and 85% for the 1688B.\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e1685B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 - 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 5 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1687B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 - 36 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 10 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e360 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1688B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 - 18 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 20 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e360 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAccessories Supplied\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower cord\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eInstruction manual\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eApplication software CD\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUSB cable\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote control connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e1685B\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eVariable Output Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 – 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eVariable Output Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 – 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eFull Load Input Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e3.7 A (100 VAC) \/ 1.7 A (230 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e82% (100 VAC) \/ 86% (230 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTracking Overvoltage Protections\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eO\/P 1-5 V: set voltage +2 V; O\/P 5-20 V: set voltage +3 V; O\/P 20-60 V: set voltage +4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Tracking OVP threshold varies with set voltage band — review the OVP table for the specific model before connecting a sensitive DUT.\u003cstrong\u003eImportant:\u003c\/strong\u003e All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 23 °C ± 5 °C.\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231624929527,"sku":"bkprec_1685b_new","price":459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1685b-new_2.jpg?v=1735285873"},{"product_id":"1670a-b-k-precision-dc-power-supply-used","title":"1670A B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne variable 0 to 30 VDC, 3 A section\u003c\/li\u003e\n\u003cli\u003eOne 12 VDC fixed section\u003c\/li\u003e\n\u003cli\u003eOne 5 VDC fixed section\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Voltage Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLine Regulation:  ≤0.05% + 10mV Main; ≤1% fixed output\u003c\/li\u003e\n\u003cli\u003eLoad Regulation: ≤0.05% + 10mV; ≤1% fixed output\u003c\/li\u003e\n\u003cli\u003eRecovery Time 100μs\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise: ≤5 mVrms\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient:  ≤300 ppm°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Current Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable Current Range: 5% to 100% (Main)\u003c\/li\u003e\n\u003cli\u003eLine Regulation: ≤0.4% + 10 mA\u003c\/li\u003e\n\u003cli\u003eLoad Regulation: ≤0.4% + 10 mA\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise: ≤10 mA rms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay: 3-digit LCD\u003c\/li\u003e\n\u003cli\u003eVoltmeter Range: 0 to 12 VDC 0 to 5 VDC\u003c\/li\u003e\n\u003cli\u003eVoltmeter Resolution: 0.1 V\u003c\/li\u003e\n\u003cli\u003eVoltmeter Accuracy: ± (1% reading + 2 digit)\u003c\/li\u003e\n\u003cli\u003eAmpmeter Resolution 0.01 A\u003c\/li\u003e\n\u003cli\u003eAmmeter Accuracy: ± (1% reading + 2 digit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eOverload Protection: Current limiting, Reverse polarity, overvoltage, Short circuit\u003c\/li\u003e\n\u003cli\u003ePower Requirements: 115\/230 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 165 W\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0 to 40°C ≤75% R.H.\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -15° to 70°C ≤85% R.H.\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 4.9” x 8.5” x 9.5\"; (124 x 216 x 242 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision 1670A Triple-Output 30 VDC, 3A Digital Display Power Supply is ideal for general electronic servicing, school electronics labs, and powering up hobbyist's projects.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231621521655,"sku":"bkprec_1670a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231621554423,"sku":"nist_traceable","price":77.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231621587191,"sku":"nist_traceable_data","price":91.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231621619959,"sku":"17025","price":126.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1670a.jpg?v=1735285882"},{"product_id":"1694-b-k-precision-dc-power-supply-new","title":"1694 B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLightweight and compact\u003c\/li\u003e\n\u003cli\u003eCurrent fold back circuitry with illuminated indicator prevents overloading the power supply\u003c\/li\u003e\n\u003cli\u003eOvertemperature protection circuitry\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection\u003c\/li\u003e\n\u003cli\u003eRemote sense\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe B\u0026amp;K Precision 1694 switching mode DC power supply provides high current output in a lightweight and compact package. It is suitable for a variety of uses, especially for powering DC operated mobile radio equipment on the bench. Voltage output is variable from 1V to 30V at 30A continuous operation. In addition, a remote sensing terminal is available for use to compensate for voltage drop across load leads. The output voltage level can also be externally controlled via an analog remote control terminal. Bright red and green LED displays provide for an accurate and highly readable indicator of settings.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231620440311,"sku":"bkprec_1694_new","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1694-new.jpg?v=1735285889"},{"product_id":"1670a-b-k-precision-dc-power-supply-new","title":"1670A B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne variable 0 to 30 VDC, 0 to 3 A variable section\u003c\/li\u003e\n\u003cli\u003eOne 12 VDC fixed section\u003c\/li\u003e\n\u003cli\u003eOne 5 VDC fixed section\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Voltage Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLine Regulation:  ≤0.05% + 10mV Main; ≤1% fixed output\u003c\/li\u003e\n\u003cli\u003eLoad Regulation: ≤0.05% + 10mV; ≤1% fixed output\u003c\/li\u003e\n\u003cli\u003eRecovery Time 100μs\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise: ≤5 mVrms\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient:  ≤300 ppm°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Current Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable Current Range: 5% to 100% (Main)\u003c\/li\u003e\n\u003cli\u003eLine Regulation: ≤0.4% + 10 mA\u003c\/li\u003e\n\u003cli\u003eLoad Regulation: ≤0.4% + 10 mA\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise: ≤10 mA rms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay: 3-digit LCD\u003c\/li\u003e\n\u003cli\u003eVoltmeter Range: 0 to 12 VDC 0 to 5 VDC\u003c\/li\u003e\n\u003cli\u003eVoltmeter Resolution: 0.1 V\u003c\/li\u003e\n\u003cli\u003eVoltmeter Accuracy: ± (1% reading + 2 digit)\u003c\/li\u003e\n\u003cli\u003eAmpmeter Resolution 0.01 A\u003c\/li\u003e\n\u003cli\u003eAmmeter Accuracy: ± (1% reading + 2 digit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eOverload Protection: Current limiting, Reverse polarity, overvoltage, Short circuit\u003c\/li\u003e\n\u003cli\u003ePower Requirements: 115\/230 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 165 W\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0 to 40°C ≤75% R.H.\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -15° to 70°C ≤85% R.H.\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 4.9” x 8.5” x 9.5\"; (124 x 216 x 242 mm)\u003c\/li\u003e\n\u003cli\u003eIncluded Accessories: Instruction Manual and spare fuse\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne-Year Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision 1670A Triple-Output 30 VDC, 3A Digital Display Power Supply is ideal for general electronic servicing, school electronics labs, and powering up hobbyist's projects.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231617196279,"sku":"bkprec_1670a_new","price":339.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1670a-new_2.jpg?v=1735285896"},{"product_id":"6032a-agilent-dc-power-supply-used","title":"Agilent 6032A 1200 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eAgilent 6032A 1200 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutoranging output delivers maximum power across a wide range of voltage and current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-output configurations covering 0–20 V to 0–500 V and currents up to 120 A across the series\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower levels from 200 W (6033A, 6038A) to 1200 W (6010A, 6012B, 6030A, 6032A) across the family\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eGPIB-equipped models (6030A–6038A) support SCPI commands and VXIPlug\u0026amp;Play drivers for system integration\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUp to 16 GPIB units can be connected through one GPIB address via serial link\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAnalog modulation input accepts 0 to 5 V or 0 to 4 kΩ for external programming of voltage and current\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote sensing supports up to 2 V drop in each lead per datasheet specifications\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEither output terminal can be grounded or floated from chassis ground within rated dc floating voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 Series Autoranging DC Power Supplies are single-output bench and system power supplies designed to deliver maximum power across a variety of operating points rather than at a single fixed voltage and current pair. The autoranging output characteristic allows one supply to cover a wide span of voltage and current combinations, which the datasheet describes as taking the place of multiple fixed-range power supplies on a test bench or in a test system. The non-GPIB 6010A, 6011A, 6012B, and 6015A models use ten-turn front panel pots for precise local control, while the GPIB-equipped 6030A through 6038A models add SCPI command compatibility and VXIPlug\u0026amp;Play drivers for integration into automated test systems.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, these supplies are intended to save rack space by using fewer outputs, reduce cost by using fewer power supplies, and — for the non-GPIB models — provide control with external voltage through the analog modulation input. The GPIB models extend this to system-level applications where the datasheet notes that up to 16 power supplies can be connected through one GPIB address via the serial link, and that the supplies have excellent electrical efficiency making them a good choice for large systems. The non-GPIB units can also be connected in auto-parallel or auto-series with their corresponding GPIB unit (6030 Series) as part of a test system.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test \u0026amp; measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement business as Keysight Technologies. Instruments originally branded HP, then Agilent, and now sold or supported by Keysight share a continuous engineering lineage across all three brand names.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 and 6030 Series Autoranging DC Power Supplies are a related family of single-output supplies sharing the same autoranging output architecture. The non-GPIB 6010A, 6011A, 6012B, and 6015A models provide front-panel control with ten-turn pots and an analog modulation input. The GPIB-equipped 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A models add SCPI command compatibility, VXIPlug\u0026amp;Play drivers, and serial-link networking for automated test system integration.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the family, models are differentiated primarily by voltage range, current range, and maximum power. The 1000 W and 1200 W class supplies (6010A, 6011A, 6012B, 6015A, 6030A, 6031A, 6032A, 6035A) cover voltage ranges from 0–20 V up to 0–500 V depending on the model, while the 200 W class supplies (6033A and 6038A) provide lower-power capability in a half-rack form factor. The 6033A and 6038A also offer the Opt 800 rack-mount kit for two half-rack units side by side.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model linked below has its own dedicated product page with pre-owned-matched pricing, current availability, and complete specifications. Click through to the specific model that matches your application's voltage, current, and power requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe primary differentiator within the family is the GPIB and SCPI capability: the 6030 Series adds remote programming, readback, and the ability to network up to 16 supplies through one GPIB address. The non-GPIB 6000 Series models can be auto-paralleled or auto-seried with their corresponding GPIB units as part of a hybrid test system. The 6030 Series also carries a three-year warranty per the datasheet, compared to a one-year warranty on the non-GPIB models.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eVoltage and current ratings vary significantly across the family. Customers needing high voltage at lower currents should consider the 0–500 V models (6015A, 6035A). Customers needing high current at lower voltages should consider the 0–20 V, 0–120 A models (6011A, 6031A). Customers needing mid-range capability with high power should consider the 0–60 V models (6012B, 6032A, 6038A) or the 0–200 V models (6010A, 6030A).\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMaximum Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6032A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6010A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6011A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6012B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e6032A\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V1, I1\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e60 V, 17.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V2, I2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e40 V, 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V3, I3\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e20 V, 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.035% + 40 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.2% + 85 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage rms (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e8 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage p-p\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e40 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Current rms\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.08% + 20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.36% + 35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response time (10% step change)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response level\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e12.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC floating voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 100 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 120 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 220 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 240 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e16.3 kg (36 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e21.8 kg (48 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Either output terminal can be grounded or floated from chassis ground within the rated dc floating voltage of ±240 V (6011A, 6012B, 6031A, 6032A, 6033A, 6038A) or ±550 V (6010A, 6015A, 6030A, 6035A).\u003cstrong\u003eImportant:\u003c\/strong\u003e A line cord option must be specified for the 6010A, 6011A, 6012B, 6015A (and for the 6030A-32A and 6035A). See pages 93-98 of the Agilent Power Products Catalog for ordering information.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 908 and Opt 909 rack-mount kits require support rails (e.g., E3663AC for Agilent rack cabinets).\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 100 (87 to 106 Vac line input) derates the power supply output to 75%.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt J01 (stabilization for loads up to 10 Henries) is not available on the 6033A.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231634497783,"sku":"120-agilen_6032a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231634530551,"sku":"120-nist_traceable","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49816653857015,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231634596087,"sku":"120-17025","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6032a_1_1.jpg?v=1735285906"},{"product_id":"1601-b-k-precision-dc-power-supply-used","title":"1601 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0-25, 0-50\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-2\u003c\/li\u003e\n\u003cli\u003eCurrent Limit Adjustment: 5%-100% of each current range\u003c\/li\u003e\n\u003cli\u003eLoad regulation: Maximum 0.1% Typical 0.07%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BK Precision 1601 uses integrated circuits, silicon transistors and diodes, and an SCR. It protects load and instrument against overload. Current limit is fully adjustable from approximately 2.5 mA to 2A. It automatically shuts down and the Overload lamp lights if the preset current limit is exceeded.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231618113783,"sku":"bkprec_1601","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231618146551,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231618179319,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231618212087,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1601_1.jpg?v=1735285909"},{"product_id":"1715a-b-k-precision-dc-power-supply-new","title":"1715A B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0-30 V\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-2 A\u003c\/li\u003e\n\u003cli\u003eContinuously monitor voltage and current output on two analog meters\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in parallel to double the current output\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in series to double the voltage output\u003c\/li\u003e\n\u003cli\u003eReliable, Durable\u003c\/li\u003e\n\u003cli\u003eOperate continuously at full load without overheating\u003c\/li\u003e\n\u003cli\u003eFully overload protected\u003c\/li\u003e\n\u003cli\u003eCoarse and fine voltage controls\u003c\/li\u003e\n\u003cli\u003eExcellent regulation\u003c\/li\u003e\n\u003cli\u003eVery low ripple\u003c\/li\u003e\n\u003cli\u003eConstant voltage or constant current operation\u003c\/li\u003e\n\u003cli\u003ecUL certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Regulation: Line (120 VAC ±10%) \u0026lt;0.01% + 3 mV; Load (no load - full load) \u0026lt;0.01% + 3 mV\u003c\/li\u003e\n\u003cli\u003eRecovery Time:  \u0026lt;100 μs\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise:  \u0026lt;1 mV rms\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: \u0026lt;300 ppm\/°C\u003c\/li\u003e\n\u003cli\u003eAdjustable Current Range: 5% to 100%\u003c\/li\u003e\n\u003cli\u003eCurrent Regulation: Line (120 VAC ±10%) \u0026lt;0.2% + 3 mA; Load \u0026lt;0.2% + 3 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Ripple: \u0026lt;3 mArms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: 4-digit LED\u003c\/li\u003e\n\u003cli\u003eVoltmeter Range: 0-99.99 V (green)\u003c\/li\u003e\n\u003cli\u003eVoltmeter Accuracy: ± (0.5% rdg +9 digits)\u003c\/li\u003e\n\u003cli\u003eAmmeter Range: 0-9.999 A\u003c\/li\u003e\n\u003cli\u003eAmmeter Accuracy: ± (0.5% rdg +9 digits)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload Protection: Current limiting, reverse polarity, overvoltage, short circuit\u003c\/li\u003e\n\u003cli\u003ePower Requirements: 120 VAC ±10%, 60 Hz only (120\/220\/230\/240 VAC ±10%, 50\/60 Hz version available)\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 210 W\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 32 to 104 °F (0 to 40 °C), \u0026lt;75% R.H.\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: 5 to 158 °F (-15 to +70 °C), \u0026lt;85% R.H.\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 6.2” x 5.5” x 12.5” (158 x 140 x 318 mm)\u003c\/li\u003e\n\u003cli\u003eIncluded Accessories Instruction manual \u0026amp; power cord\u003c\/li\u003e\n\u003cli\u003eTwo-Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision 1715A 4 Digit Display DC Power Supply (0-60V, 0-2A) continuously monitors voltage and current output on two analog meters. Connect two supplies in parallel to double the current output or connect two supplies in series to double the voltage output. The BK 1715A operates continuously at full load without overheating. \u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231625519351,"sku":"bkprec_1715a_new","price":631.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1715a-new.jpg?v=1735285911"},{"product_id":"6034a-agilent-dc-power-supply-used","title":"6034A Agilent DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent: 10A\u003c\/li\u003e\n\u003cli\u003eVoltage: 60V\u003c\/li\u003e\n\u003cli\u003ePower: 200W\u003c\/li\u003e\n\u003cli\u003e104 to 127 Vac; 47-63 Hz operation\u003c\/li\u003e\n\u003cli\u003eIdeal for a wide range of voltage\/current combinations\u003c\/li\u003e\n\u003cli\u003eSingle Output\u003c\/li\u003e\n\u003cli\u003eUL\/CSA\u003c\/li\u003e\n\u003cli\u003eGPIB (SCPI)\u003c\/li\u003e\n\u003cli\u003eSerial link connects 16 units to one GPIB address\u003c\/li\u003e\n\u003cli\u003eMeasured V \u0026amp; I readback over GPIB\u003c\/li\u003e\n\u003cli\u003eAutoranging outputs provide maximum power\u003c\/li\u003e\n\u003cli\u003eAnalog\/resistance control of output voltage and current\u003c\/li\u003e\n\u003cli\u003eSeries and auto-parallel connections of multiple supplies\u003c\/li\u003e\n\u003cli\u003eBuilt-in measurements and advanced programmable features\u003c\/li\u003e\n\u003cli\u003eProtection features to ensure DUT safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Agilent HP 6034A DC Power Supply has a combination of features and specifications that characterize it as a comprehensive solution to HPIB system power supply applications. The Agilent HP 6034A combines FET switching technology with an internal microprocessor based HPIB programmer to yield an excellent bidirectional programmable autoranging DC power supply.\u003c\/p\u003e\n\u003cp\u003eThe Agilent HP 6034A is part of the 603x family of power supplies which provide a wide and continuous range of output voltage and current levels at the rated power output. They provide great flexibility for applications with varied or changing needs.\u003c\/p\u003e\n\u003cp\u003eThe single-output, autoranging 200 W, GPIB 6034A provides analog\/resistance control of output voltage and current; series and auto-parallel connections of multiple supplies; and built-in measurements and advanced programmable features. The Agilent 200 W, single-output 6034A is an efficient solution for large demanding test systems that saves rack space and reduces system complexity.\u003c\/p\u003e\n\u003cp\u003eThis series of 200 watt and 1000 watt DC power supplies take the place of multiple power supplies in your test system by providing maximum power at a variety of operating points.\u003c\/p\u003e\n\u003cp\u003eIndustry standard SCPI commands and VXIPlug\u0026amp;Play drivers make system integration easy. Using the serial link, up to 16 power supplies can be connected through one GPIB address. These power supplies have excellent electrical efficiency, making them a good choice for large systems.\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231622963447,"sku":"agilen_6034a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231622996215,"sku":"nist_traceable","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231623028983,"sku":"nist_traceable_data","price":0.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231623061751,"sku":"17025","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6034a.jpg?v=1735285917"},{"product_id":"1621a-b-k-precision-dc-power-supply-new","title":"1621A B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0-18 V\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-5 A\u003c\/li\u003e\n\u003cli\u003eOutput Power: 90 W\u003c\/li\u003e\n\u003cli\u003eContinuously monitor voltage and current output on two digital meters\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in parallel to double the current output\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in series to double the voltage output\u003c\/li\u003e\n\u003cli\u003eNew compact style\u003c\/li\u003e\n\u003cli\u003eReliable, Durable\u003c\/li\u003e\n\u003cli\u003eOperate continuously at full load without overheating\u003c\/li\u003e\n\u003cli\u003eFully overload protected\u003c\/li\u003e\n\u003cli\u003eCoarse and fine voltage controls\u003c\/li\u003e\n\u003cli\u003eGreat regulation\u003c\/li\u003e\n\u003cli\u003eVery low ripple\u003c\/li\u003e\n\u003cli\u003eConstant voltage or constant current operation\u003c\/li\u003e\n\u003cli\u003eIncluded accessories: User manual and power cord\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne-Year Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Voltage Operation Voltage Regulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLine (120 VAC +10%, -6%): \u0026lt;0.02% + 3 mV\u003c\/li\u003e\n\u003cli\u003eLoad (no load - full load): \u0026lt;0.02% + 3 mV\u003c\/li\u003e\n\u003cli\u003eRecovery Time: \u0026lt;500 ms\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise: \u0026lt;1 mVrms\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: \u0026lt;300 ppm\/°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Current Operation Current Regulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable Current Range: 0-100%\u003c\/li\u003e\n\u003cli\u003eLine (120 VAC +10%, -6%): \u0026lt;0.02% + 3 mA\u003c\/li\u003e\n\u003cli\u003eLoad: \u0026lt;0.02% + 3 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Ripple: \u0026lt;3 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: 3-digit LED\u003c\/li\u003e\n\u003cli\u003eVoltmeter Range: 0-18 V\u003c\/li\u003e\n\u003cli\u003eVoltmeter Accuracy: ±2% + 2 digits\u003c\/li\u003e\n\u003cli\u003eAmmeter Range: 0-9.99 A\u003c\/li\u003e\n\u003cli\u003eAmmeter Accuracy: ±2% +2 digits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload Protection: Current, limiting, reverse polarity, overvoltage, short circuit\u003c\/li\u003e\n\u003cli\u003eAC Input: 120 VAC ±10%, 60 Hz (120\/220\/230\/24C VAC ±10%, 50\/60 Hz version available)\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 220 W\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 32 to 104 °F (0 to 40 °C), \u0026lt;75% R.H.\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: 5 to 158 °F (-15 to +70 °C), \u0026lt;85% R.H.\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 8.07” x 4.53” x 10.63\" (205 x 115 x 270 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision Analog and Digital series are high quality serial control type DC Regulated Power Supplies. These models can be operated at constant voltage or constant current mode whose output can be varied from 0 up to the rated values for respective model.\u003c\/p\u003e\n\u003cp\u003eThe BK Precision 1621A is a compact unit provided with separate voltage and current meter for monitoring the output voltage and current simultaneously. In terms of operability, these units enable high precision, continuous variability via coarse and fine adjust knobs. The BK Precision Analog and Digital series can be connected in parallel with multiple units of the same model set up a “master\/slave” configuration to increase the output current capability. Serial connection of multiple units can be used to increase the output voltage level.\u003c\/p\u003e\n\u003cp\u003eThis family of power supplies provides clean and stable DC output which is most suitable for many areas including laboratory, industrial, field service, hobby, and telecommunication applications.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231631122679,"sku":"bkprec_1621a_new","price":362.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1621a-new_1.jpg?v=1735285919"},{"product_id":"6002a-agilent-dc-power-supply-used","title":"HP 6002A Extended Range DC Power Supply, 0-50V\/0-10A 200W (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eHP 6002A Extended Range DC Power Supply, 0-50V\/0-10A 200W (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAdjustable 0–50V and 0–10A output with 200W maximum power available across a wide range of voltage\/current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eExtended range technique delivers full 200W from 20V\/10A up to 50V\/4A, not limited to a single rectangular operating locus\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eConstant Voltage \/ Constant Current (CV\/CC) automatic crossover with front panel mode indicators\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAdjustable overvoltage protection crowbar with trip point settable from 2.5V to 60V\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFront panel LED status indicators for Voltage Mode, Current Mode, Overvoltage, and Overrange conditions\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote programming, remote voltage sensing, and auto-parallel \/ auto-series \/ auto-tracking operation supported via rear terminals\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSwitchable AC input (100\/120\/220\/240Vac, 48-63Hz) via rear panel power module PC board\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eOptional HP-IB Interface (Option 001) for digital control of output voltage or current from a calculator, computer, or other controller\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe HP 6002A is a laboratory-type DC power supply that employs an extended range technique to furnish maximum output power over a wide range of voltage and current combinations. As described on the datasheet, the supply provides a full 200 watts of output from 20V\/10A up to 50V\/4A, with the output completely adjustable through the entire operating range of 0 to 50 volts and 0 to 10 amps via front panel voltage and current controls. The unit is a Constant Voltage \/ Constant Current (CV\/CC) type and is packaged in a System II modular enclosure.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, the 6002A is intended for general laboratory use where a single supply needs to cover a wide range of voltage and current combinations rather than being restricted to a single rectangular operating locus. Documented operating modes include local front panel control, remote voltage sensing at the load, remote programming by either resistance or voltage source, auto-parallel operation for greater current capacity, auto-series operation for greater voltage capability (up to three units), and auto-tracking operation where two or three supplies share a common negative bus and are simultaneously programmed from a master. With the optional HP-IB Interface (Option 001), output voltage or current can be programmed digitally from a calculator, computer, or other controller.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test and measurement business was spun off as Agilent Technologies in 1999, and Agilent's electronic measurement business was subsequently transferred to Keysight Technologies in 2014. Instruments originally manufactured under the HP brand — including the 6002A — therefore trace through Agilent to Keysight as the current corporate successor for legacy HP T\u0026amp;M product support.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe HP 6002A is documented in this datasheet as a single-model laboratory power supply with one optional configuration: Option 001, which adds an HP-IB Interface for digital control of output voltage or current from a calculator, computer, or other controller. The base unit and the Option 001 unit share the same DC output characteristics — 0 to 50V and 0 to 10A with 200W maximum output power — and the same regulation, PARD, and overvoltage protection specifications.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Option 001 modification involves the addition of three internal PC boards (A100 Input Board, A200 Digital Board, A300 Analog Board), two mode switches (CV\/CC\/LOCAL), and an HP-IB connector on the rear panel. Option 001 hardware does not change the supply's output performance — it adds a programming path. The datasheet specifies HP-IB programming speed of approximately 100msec (no load) to 200msec (full load) for output transitions between 0 and 100% or 100% to 0.1% of maximum rated output.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach pre-owned 6002A configuration shown is its own product page with condition-matched pricing. Select the base 6002A or the HP-IB-equipped Option 001 variant based on whether your application requires digital programming from a controller, then choose the condition tier that matches your quality system and budget requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe functional difference between the base 6002A and the Option 001 variant is the addition of HP-IB digital programming capability. The base unit is controlled exclusively via front panel knobs or rear terminal analog remote programming (resistance or voltage source). The Option 001 unit retains those local and analog control paths and adds HP-IB control through a 24-pin micro-ribbon connector on the rear panel, with a pair of CV\/CC\/LOCAL mode switches selecting the active control mode.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eProgramming resolution differs between the supply's two HP-IB programmable ranges (Option 001 only). The datasheet specifies high-range resolution of 50mV (CV) and 10mA (CC) and low-range resolution of 10mV (CV) and 2mA (CC); accuracy is 0.2% plus 25mV or 25mA depending on range and mode. Customers building automated test systems around legacy HP-IB infrastructure should specify Option 001; customers using the supply as a manually controlled bench instrument can use either configuration.\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6002A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 10 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAccessories Supplied\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\u003cli style=\"margin:0 0 6px 0;\"\u003e3-wire detachable line cord\u003c\/li\u003e\u003c\/ul\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eInput Power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e100\/120\/220\/240 Vac (-13%, +6%), 48-63 Hz. 3-wire detachable line cord supplied.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC Output\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAdjustable from 0-50V and 0-10A. Maximum output power is 200W from 20-50V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad Effect (Load Regulation), Constant Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 0.01% of output plus 1mV for a load change equal to the maximum current rating of the supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad Effect (Load Regulation), Constant Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 0.01% of output plus 1mA for a load change equal to the maximum voltage rating of the supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eSource Effect (Line Regulation), Constant Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 0.01% of output plus 1mV for any line voltage change within rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eSource Effect (Line Regulation), Constant Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 0.01% of output plus 1mA for any line voltage change within rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003ePARD (Ripple and Noise), Constant Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 1mV rms and 10mV p-p (20Hz to 20MHz).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003ePARD (Ripple and Noise), Constant Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 5mA rms.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTemperature Coefficient, Constant Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 0.02% plus 200µV change in output per degree Celsius change in ambient following a 30-minute warmup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTemperature Coefficient, Constant Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 0.02% plus 5mA change in output per degree Celsius change in ambient following a 30-minute warmup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDrift (Stability), Constant Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 0.05% of output plus 1mV (over 8-hour interval under constant line, load, and ambient temperature following a 30-minute warmup).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDrift (Stability), Constant Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 0.05% of output plus 5mA.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad Transient Recovery Time\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLess than 100µsec required for output voltage recovery (in constant voltage operation) to within 15mV of the nominal output following a change in output current from 50% to 100% or 100% to 50% of maximum current rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRemote Resistance Control\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eCV: 1KΩ\/V ±7%   CC: 100Ω\/A ±7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRemote Voltage Control\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eCV: 1V\/V ±20mV (-50mV offset)   CC: 50mV\/A ±10% 7.5 mV offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eResponse Time (UP)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNo Load - 100msec; Full Load - 100msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eResponse Time (DOWN)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNo Load - 400msec; Full Load - 200msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTrip voltage adjustable from 3.5V to 60V. Minimum setting above output voltage to avoid false tripping is 1 volt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC Output Isolation\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e150 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTemperature Ratings\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOperating: 0 to 55°C; Storage: -40 to +75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eCV: 10mV   CC: 10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTypical value is 0.5mΩ in series with 1µH.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOptions\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e001 HP-IB Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14.5 kg (32 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15.9 kg (35 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Maximum input voltage rating: ±35 V peak (AC+DC) does not apply to this unit. For the 6002A, the documented DC output isolation is 150Vdc — either output terminal can be grounded, or the output can be floated up to 150 volts above ground.\u003cstrong\u003eImportant:\u003c\/strong\u003e When the power supply is remote programmed with a voltage source, the programming voltage can appear at the output terminals when the AC input power is turned off. Do not contact the output terminals; the front panel meters will not indicate the presence of this voltage.\u003cstrong\u003eImportant:\u003c\/strong\u003e When using remote voltage sensing, it is possible to damage the supply by disconnecting a load lead while the sensing lead is still connected and the supply is energized. If a load lead becomes disconnected, current flows through internal protection diodes A2CR9-CR10, the sensing leads, and the load and may burn out the diodes or connecting track on the PC board.\u003cstrong\u003eImportant:\u003c\/strong\u003e Do not allow programming terminals A4 or A6 to become open-circuited while resistance programming the output current. If they do open, the supply's output current rises to a value that may damage the supply or the load.\u003cstrong\u003eImportant:\u003c\/strong\u003e Disconnect input AC power before changing any rear panel connections and make certain all wires and straps are properly connected and terminal strip screws are securely tightened before reapplying power.\u003cstrong\u003eImportant:\u003c\/strong\u003e Most of the attaching hardware in this unit is non-metric (sometimes called English or inch). The only metric fittings are strap handle screws (Qty. 2), strap handle nut (Qty. 1), and screws attaching side struts to front and rear chassis (Qty. 16).\u003cstrong\u003eImportant:\u003c\/strong\u003e Agilent (formerly Hewlett-Packard) no longer sells or supports this product. Service centers may be able to perform calibration if no repair parts are needed, but no other support from Agilent is available.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eValueTronics warranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Hewlett Packard","offers":[{"title":"None","offer_id":49231629320439,"sku":"agilen_6002a","price":0.0,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49231629353207,"sku":"nist_traceable","price":0.0,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49231629385975,"sku":"nist_traceable_data","price":0.0,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49231629418743,"sku":"17025","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6002a.jpg?v=1735285926"},{"product_id":"1693-b-k-precision-dc-power-supply-new","title":"1693 B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 60 A output current\u003c\/li\u003e\n\u003cli\u003eLightweight and compact\u003c\/li\u003e\n\u003cli\u003eDual 3-digit LED displays\u003c\/li\u003e\n\u003cli\u003eRemote sense terminal\u003c\/li\u003e\n\u003cli\u003eAnalog remote control via external voltage source or variable resistor\u003c\/li\u003e\n\u003cli\u003eCurrent foldback circuitry with illuminated indicator prevents overloading the power supply\u003c\/li\u003e\n\u003cli\u003eOvertemperature protection circuitry\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection\u003c\/li\u003e\n\u003cli\u003eFront panel auxiliary output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe B\u0026amp;K Precision 1693 switching mode DC power supply provides high current output in a lightweight and compact package. It is suitable for a variety of uses, especially for powering DC operated mobile radio equipment on the bench. Voltage output is variable from 1V to 15V at 60A continuous operation. In addition, a remote sensing terminal is available for use to compensate for voltage drop across load leads. The output voltage level can also be externally controlled via an analog remote control terminal. Bright red and green LED displays provide for an accurate and highly readable indicator of settings.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231622308087,"sku":"bkprec_1693_new","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1693-new.jpg?v=1735285928"},{"product_id":"6011a-agilent-dc-power-supply-used","title":"Agilent 6011A 1064 W Single-Output Autoranging DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eAgilent 6011A 1064 W Single-Output Autoranging DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutoranging output delivers maximum power across a wide range of voltage and current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-output configurations covering 0–20 V to 0–500 V and currents up to 120 A across the series\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower levels from 200 W (6033A, 6038A) to 1200 W (6010A, 6012B, 6030A, 6032A) across the family\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eGPIB-equipped models (6030A–6038A) support SCPI commands and VXIPlug\u0026amp;Play drivers for system integration\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUp to 16 GPIB units can be connected through one GPIB address via serial link\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAnalog modulation input accepts 0 to 5 V or 0 to 4 kΩ for external programming of voltage and current\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote sensing supports up to 2 V drop in each lead per datasheet specifications\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEither output terminal can be grounded or floated from chassis ground within rated dc floating voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 Series Autoranging DC Power Supplies are single-output bench and system power supplies designed to deliver maximum power across a variety of operating points rather than at a single fixed voltage and current pair. The autoranging output characteristic allows one supply to cover a wide span of voltage and current combinations, which the datasheet describes as taking the place of multiple fixed-range power supplies on a test bench or in a test system. The non-GPIB 6010A, 6011A, 6012B, and 6015A models use ten-turn front panel pots for precise local control, while the GPIB-equipped 6030A through 6038A models add SCPI command compatibility and VXIPlug\u0026amp;Play drivers for integration into automated test systems.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, these supplies are intended to save rack space by using fewer outputs, reduce cost by using fewer power supplies, and — for the non-GPIB models — provide control with external voltage through the analog modulation input. The GPIB models extend this to system-level applications where the datasheet notes that up to 16 power supplies can be connected through one GPIB address via the serial link, and that the supplies have excellent electrical efficiency making them a good choice for large systems. The non-GPIB units can also be connected in auto-parallel or auto-series with their corresponding GPIB unit (6030 Series) as part of a test system.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test \u0026amp; measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement business as Keysight Technologies. Instruments originally branded HP, then Agilent, and now sold or supported by Keysight share a continuous engineering lineage across all three brand names.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 and 6030 Series Autoranging DC Power Supplies are a related family of single-output supplies sharing the same autoranging output architecture. The non-GPIB 6010A, 6011A, 6012B, and 6015A models provide front-panel control with ten-turn pots and an analog modulation input. The GPIB-equipped 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A models add SCPI command compatibility, VXIPlug\u0026amp;Play drivers, and serial-link networking for automated test system integration.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the family, models are differentiated primarily by voltage range, current range, and maximum power. The 1000 W and 1200 W class supplies (6010A, 6011A, 6012B, 6015A, 6030A, 6031A, 6032A, 6035A) cover voltage ranges from 0–20 V up to 0–500 V depending on the model, while the 200 W class supplies (6033A and 6038A) provide lower-power capability in a half-rack form factor. The 6033A and 6038A also offer the Opt 800 rack-mount kit for two half-rack units side by side.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model linked below has its own dedicated product page with pre-owned-matched pricing, current availability, and complete specifications. Click through to the specific model that matches your application's voltage, current, and power requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe primary differentiator within the family is the GPIB and SCPI capability: the 6030 Series adds remote programming, readback, and the ability to network up to 16 supplies through one GPIB address. The non-GPIB 6000 Series models can be auto-paralleled or auto-seried with their corresponding GPIB units as part of a hybrid test system. The 6030 Series also carries a three-year warranty per the datasheet, compared to a one-year warranty on the non-GPIB models.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eVoltage and current ratings vary significantly across the family. Customers needing high voltage at lower currents should consider the 0–500 V models (6015A, 6035A). Customers needing high current at lower voltages should consider the 0–20 V, 0–120 A models (6011A, 6031A). Customers needing mid-range capability with high power should consider the 0–60 V models (6012B, 6032A, 6038A) or the 0–200 V models (6010A, 6030A).\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMaximum Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6011A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6010A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6012B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6015A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 500 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 5 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,050 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e6011A\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V1, I1\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e20 V, 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V2, I2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 V, 76 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V3, I3\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e7 V, 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage rms (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e8 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage p-p\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Current rms\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response time (10% step change)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response level\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC floating voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 100 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 120 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 220 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 240 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e17.2 kg (38 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e22.7 kg (50 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Either output terminal can be grounded or floated from chassis ground within the rated dc floating voltage of ±240 V (6011A, 6012B, 6031A, 6032A, 6033A, 6038A) or ±550 V (6010A, 6015A, 6030A, 6035A).\u003cstrong\u003eImportant:\u003c\/strong\u003e A line cord option must be specified for the 6010A, 6011A, 6012B, 6015A (and for the 6030A-32A and 6035A). See pages 93-98 of the Agilent Power Products Catalog for ordering information.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 908 and Opt 909 rack-mount kits require support rails (e.g., E3663AC for Agilent rack cabinets).\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 100 (87 to 106 Vac line input) derates the power supply output to 75%.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt J01 (stabilization for loads up to 10 Henries) is not available on the 6033A.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231617261815,"sku":"agilen_6011a","price":4663.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231617294583,"sku":"nist_traceable","price":4873.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231617327351,"sku":"nist_traceable_data","price":4943.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231617360119,"sku":"17025","price":4978.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6011a.jpg?v=1735285934"},{"product_id":"1737-b-k-precision-dc-power-supply-new","title":"1737 B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual range to accommodate applications requiring either a higher voltage or a higher current\u003c\/li\u003e\n\u003cli\u003eLow ripple and noise\u003c\/li\u003e\n\u003cli\u003eExcellent regulation\u003c\/li\u003e\n\u003cli\u003eConstant voltage (CV) and constant current (CC) mode operation\u003c\/li\u003e\n\u003cli\u003eTwo 4-digit LED displays provide good visibility in bright or low light\u003c\/li\u003e\n\u003cli\u003eLED indication for CV and CC modes\u003c\/li\u003e\n\u003cli\u003eAutomatic recall of last settings on power up\u003c\/li\u003e\n\u003cli\u003eRS-232 interface\u003c\/li\u003e\n\u003cli\u003eFront panel emulation software available for download\u003c\/li\u003e\n\u003cli\u003eIsolated output\u003c\/li\u003e\n\u003cli\u003eOverload protection\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe B\u0026amp;K Precision 1737 is a general purpose dual range DC power source. This power supply has two ranges and can output higher voltage at a lower current range or higher current at a lower voltage range. The BK Precision 1737 provides a 0-30 V, 0-3 A range and a 0-60 V, 0-2 A range. Voltage and current are both adjustable with coarse and fine control knobs. Two large LED meters continuously monitor the output voltage and current. The power supply can be operated locally from the front panel or remotely through the RS-232 interface.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231621488887,"sku":"bkprec_1737_new","price":579.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1737-new.jpg?v=1735285937"},{"product_id":"1747-b-k-precision-dc-power-supply-new","title":"1747 B\u0026K Precision DC Power Supply New","description":"\u003cp class=\"ui-tabs-panel ui-widget-content ui-corner-bottom\"\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"ui-tabs-panel ui-widget-content ui-corner-bottom\"\u003e\n\u003cul\u003e\n\u003cli\u003eLow ripple and noise\u003c\/li\u003e\n\u003cli\u003eExcellent regulation\u003c\/li\u003e\n\u003cli\u003eConstant voltage (CV) and constant current (CC) operation\u003c\/li\u003e\n\u003cli\u003eTwo large, easy-to-read LED displays provide good visibility in bright or low light\u003c\/li\u003e\n\u003cli\u003eLED indication for CV and CC modes\u003c\/li\u003e\n\u003cli\u003eAutomatic recall of last settings on power up\u003c\/li\u003e\n\u003cli\u003eRS-232 interface\u003c\/li\u003e\n\u003cli\u003eIsolated output\u003c\/li\u003e\n\u003cli\u003eOverload protection\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Accessories: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eInstruction Manual\u003c\/li\u003e\n\u003cli\u003eRS-232 cable\u003c\/li\u003e\n\u003cli\u003eshorting bar\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2 Year Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BK Precision 1747 is a general purpose dual range DC power source. This power supply has two ranges and can output higher voltage at a lower current range or higher current at a lower voltage range. The BK Precision 1747 provides a 0-35 V, 0-10 A range and a 0-60 V, 0-5 A range. Voltage and current are both adjustable with coarse and fine control knobs. Two large LED meters continuously monitor the output voltage and current. The power supply can be operated locally from the front panel or remotely through the RS-232 interface.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231624077559,"sku":"bkprec_1747_new","price":1161.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1747-new.jpg?v=1735285945"},{"product_id":"1730-b-k-precision-dc-power-supply-used","title":"1730 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLargest selection of voltage and current ratings ever offered\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in parallel to double the current output\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in series to double the voltage output\u003c\/li\u003e\n\u003cli\u003eReliable, Durable\u003c\/li\u003e\n\u003cli\u003eOperate continuously at full load without overheating\u003c\/li\u003e\n\u003cli\u003eFully overload protected\u003c\/li\u003e\n\u003cli\u003eCoarse and fine voltage controls\u003c\/li\u003e\n\u003cli\u003eExcellent regulation\u003c\/li\u003e\n\u003cli\u003eVery low ripple\u003c\/li\u003e\n\u003cli\u003eConstant voltage or constant current operation\u003c\/li\u003e\n\u003cli\u003eContinuously monitor voltage and current output on two meters\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231626141943,"sku":"bkprec_1730","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231626174711,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231626207479,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231626240247,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1730.jpg?v=1735285952"},{"product_id":"1670-b-k-precision-dc-power-supply-used","title":"1670 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput #1\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: Variable 0-30 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent: 0 to 2.5 Amps\u003c\/li\u003e\n\u003cli\u003ePolarity: Positive or Negative\u003c\/li\u003e\n\u003cli\u003eConnectors: Binding Posts\u003c\/li\u003e\n\u003cli\u003eRegulation Type: Constant Voltage or Constant Current\u003c\/li\u003e\n\u003cli\u003eConstant Voltage Mode\u003c\/li\u003e\n\u003cli\u003eLoad Regulation (0 to rated output): ≤ 0.05% + 10 mV\u003c\/li\u003e\n\u003cli\u003eLine Regulation (108 to 132 VAC): ≤ 0.05% to + 10 mV\u003c\/li\u003e\n\u003cli\u003eRipple and Noise: ≤5 mV rms\u003c\/li\u003e\n\u003cli\u003eConstant Current Mode\u003c\/li\u003e\n\u003cli\u003eLoad Regulation: ≤0.4% + 10 mA\u003c\/li\u003e\n\u003cli\u003eLine Regulation (108 to 132 VAC): ≤0.4% + 10 mA\u003c\/li\u003e\n\u003cli\u003eRipple and Noise: ≤10 mA rms\u003c\/li\u003e\n\u003cli\u003eProtection: Current limiting, short circuit protection, reverse polarity protection\u003c\/li\u003e\n\u003cli\u003eVoltage Indicator: 3 digit LCD\u003c\/li\u003e\n\u003cli\u003eVoltage Resolution: 0.1 V\u003c\/li\u003e\n\u003cli\u003eVoltage Accuracy: ± (0.5% reading + 1 digit)\u003c\/li\u003e\n\u003cli\u003eCurrent Indicator: 3 digit LCD\u003c\/li\u003e\n\u003cli\u003eAmmeter resolution: ±0.01A\u003c\/li\u003e\n\u003cli\u003eAmmeter Accuracy: ± (0.5% reading + 1 digit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput #2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: Fixed 12 VDC ±5%\u003c\/li\u003e\n\u003cli\u003eCurrent: 0 to 500 mA continuous\u003c\/li\u003e\n\u003cli\u003ePolarity: Positive or Negative\u003c\/li\u003e\n\u003cli\u003eConnectors: Wire Clips\u003c\/li\u003e\n\u003cli\u003eLoad Regulation (no load to 500 mA): ≤1%\u003c\/li\u003e\n\u003cli\u003eLine Regulation: ≤1%\u003c\/li\u003e\n\u003cli\u003eRipple and Noise: ≤5 mV rms\u003c\/li\u003e\n\u003cli\u003eProtection: Short circuit protection, thermal overload protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput #3\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: Fixed 5 VDC ±5%\u003c\/li\u003e\n\u003cli\u003eCurrent: 0 to 500 mA continuous\u003c\/li\u003e\n\u003cli\u003ePolarity: Positive or Negative\u003c\/li\u003e\n\u003cli\u003eConnectors: Wire Clips\u003c\/li\u003e\n\u003cli\u003eLoad Regulation (no load to 500 mA): ≤1%\u003c\/li\u003e\n\u003cli\u003eLine Regulation: ≤1%\u003c\/li\u003e\n\u003cli\u003eRipple and Noise: ≤5 mV rms\u003c\/li\u003e\n\u003cli\u003eProtection: Short circuit protection, thermal overload protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCooling: Convection\u003c\/li\u003e\n\u003cli\u003ePower Requirements: 108-132 VAC, 60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 170 W\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0° to 40°C, ≤75% RH\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -15°C, ≤85% RH\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 5-1\/2\" x 5-7\/8\" x 9-1\/2\" (140 x 150 x 240mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe BK Precision Model 1670 is a general purpose triple output DC power supply. The main output is a versatile constant voltage or constant current regulated power source that is variable from 0 to 30 volts and 0 to 2.5 amps. An indicator lights in the constant current mode, and serves as an overload indicator in the constant voltage mode.\u003c\/p\u003e\n\u003cp\u003eWhile the Model 1670 is competitively priced with most single output power supplies. it has the added advantage of fixed 5 volt and 12 volt outputs capable of providing up to 0.5 amp each. One common application for this power supply is powering of circuit boards while troubleshooting. Many circuit boards require two or three input coltages, with the most common values being 5 volts and 12 volts. This power supply can provide up to three outputs simultaneously. Since each output is fully isolated, any output can be connected for positive or negative polarity.\u003c\/p\u003e\n\u003cp\u003eThe main output voltage and current are continuously monitored by two digital LCD meters with resolution of 0.1 volt and 0.01 amp.\u003c\/p\u003e\n\u003cp\u003eThe Model 1670 can operate continuously at its maximum rated output and is fully overload protected.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231619850487,"sku":"bkprec_1670","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231619883255,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231619916023,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231619948791,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1670.jpg?v=1735285955"},{"product_id":"1760a-b-k-precision-dc-power-supply-new","title":"1760A B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0-30V (A \u0026amp; B) and 4-6.5 V (C)\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-2A (A \u0026amp; B) and 5A (C)\u003c\/li\u003e\n\u003cli\u003eConstant voltage (CV) and constant current (CC) operation\u003c\/li\u003e\n\u003cli\u003eIndependent or series tracking\/parallel mode operation to double voltage or current\u003c\/li\u003e\n\u003cli\u003eCoarse and fine voltage controls\u003c\/li\u003e\n\u003cli\u003eAdjustable current limiting\u003c\/li\u003e\n\u003cli\u003eDesigned to operate continuously at rated output\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection and reverse polarity protection\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTwo-Year Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cb\u003eConstant Voltage Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLine Regulation: (120 VAC ±10%): ≤0.01% +3 mV (A\u0026amp;B); ≤10 mV (C)\u003c\/li\u003e\n\u003cli\u003eLoad Regulation: ≤0.01% +3 mV (A\u0026amp;B); ≤10 mV (C)\u003c\/li\u003e\n\u003cli\u003eRecovery Time:  100 μs\u003c\/li\u003e\n\u003cli\u003eRipple: ≤1 mV rms\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: ≤300 ppm\/°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eConstant Current Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable Current Limit: 5% to 100% (A\u0026amp;B)\u003c\/li\u003e\n\u003cli\u003eLine Regulation (120 VAC ±10%): ≤0.2% + 3 mA\u003c\/li\u003e\n\u003cli\u003eLoad Regulation: ≤0.2% + 3 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Ripple: ≤3 mArms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMetering\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: Two 4-digit LED\u003c\/li\u003e\n\u003cli\u003eVoltmeter Resolution: 10 mV\u003c\/li\u003e\n\u003cli\u003eVoltmeter Accuracy: ± (0.5% rdg + 9 digits)\u003c\/li\u003e\n\u003cli\u003eAmmeter Resolution: 1 mA\u003c\/li\u003e\n\u003cli\u003eAmmeter Accuracy: ± (0.5% rdg + 9 digits)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eGeneral\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload Protection: Current limiting, reverse polarity, overvoltage, short circuit\u003c\/li\u003e\n\u003cli\u003eAC Input: 108-132 VAC 60 Hz 120\/220\/230\/240\/ VAC, ±10%, 50\/60 Hz version available\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 350 W\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0° to 40°C \u0026lt;= 85% R.H.\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -15° to 70°C \u0026lt;= 85% R.H.\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 10.5 x 5.7 x 15\" (267 x 145 x 381 mm)\u003c\/li\u003e\n\u003cli\u003eSupplied Accessories: User manual, spare fuse and power cord\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision 1760A Triple Output DC Power Supply offers outputs with two 0-30V, 0-2A and one 4-6.5V, 5A, outputs with two 4-digit LED displays. The BK 1760A 4-digit LED displays offer 10mV and 1mA resolution which provides higher accuracy. This makes it an ideal power supply for sensitive applications.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231621980407,"sku":"bkprec_1760a_new","price":928.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1760a-new_1.jpg?v=1735285958"},{"product_id":"1688b-b-k-precision-dc-power-supply-new","title":"B\u0026K Precision 1688B 18V\/20A Switching Mode DC Power Supply","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eB\u0026amp;K Precision 1688B 18V\/20A Switching Mode DC Power Supply\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eThree output configurations across the series: 1–60V\/5A (1685B), 1–36V\/10A (1687B), 1–18V\/20A (1688B)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutomatic CV\/CC crossover operation with overvoltage, overtemperature, and overload protection\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRotary encoder control knobs with dual-action push for coarse and fine voltage\/current setting\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSave up to 3 user-defined voltage and current presets for quick recall via rear-panel switch\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUSB interface plus analog remote control terminal for PC software control or external voltage\/resistor programming\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eExternal timed programming: up to 20 voltage\/current steps, 99 min 59 sec step time, 999 running cycles\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFront panel auxiliary output (5A max) alongside main rear output terminals\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower factor correction \u0026gt;0.95 at optimal load; 81–86% efficiency depending on model and line voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe B\u0026amp;K Precision 1685B Series is a family of laboratory-grade switching mode DC power supplies designed to deliver high current output in a small, lightweight form factor. The series comprises three models that share a common chassis and control architecture while offering different output configurations: the 1685B (1–60V, 0–5A), the 1687B (1–36V, 0–10A), and the 1688B (1–18V, 0–20A). All three models measure 7.9 x 3.5 x 8.2 inches and weigh 5.2 pounds, making them practical for benches where space and portability matter.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThese supplies are positioned for production testing, telecommunications work, R\u0026amp;D benches, electronic field service, and university laboratory environments. The combination of high current output, compact form factor, and remote programming capability suits applications where a controllable DC source is needed but a full-size linear supply would be impractical. Each unit ships with a power cord, instruction manual, application software CD, USB cable, and remote control connector.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eB\u0026amp;K Precision was founded in 1951 in Chicago, Illinois, and is currently headquartered in Yorba Linda, California. The company has operated continuously under the B\u0026amp;K Precision name throughout its history.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe 1685B Series consists of three switching mode DC power supplies that share a common chassis, control interface, and feature set while differing in output voltage and current configuration. The 1685B provides the highest voltage at 60V with 5A current capacity, the 1687B occupies a middle position at 36V\/10A, and the 1688B delivers the highest current at 20A within an 18V range. Voltage × current works out to 300W for the 1685B, 360W for the 1687B, and 360W for the 1688B.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAcross the series, regulation specifications, ripple and noise levels, meter accuracy, switching frequency, transient response, and protection features are identical. The differentiation between the three models is purely in the output range — selection is driven by the voltage and current requirements of the device under test, not by performance tier.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model in the 1685B Series is offered on its own product page with new pricing matched to the specific configuration. The links below route to the dedicated page for each model, where current availability, accessories included, and any condition notes specific to that unit are documented.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe most important spec to match when choosing among the three models is the combination of voltage and current the DUT requires. The 1685B reaches 60V but is limited to 5A — appropriate for higher-voltage, lower-current devices. The 1688B reaches only 18V but delivers up to 20A — appropriate for lower-voltage, higher-current devices such as automotive electronics and certain RF amplifier supplies. The 1687B sits between them with a balance of 36V at 10A that suits a wider range of general-purpose bench applications.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eFull-load input current also varies slightly with model and line voltage. At 100 VAC, the 1685B draws 3.7A, while both the 1687B and 1688B draw 4.6A. At 230 VAC, the 1685B draws 1.7A and the 1687B\/1688B both draw 2.1A. Efficiency at 230 VAC is 86% for the 1685B and 1687B, and 85% for the 1688B.\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e1688B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 - 18 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 20 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e360 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1685B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 - 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 5 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1687B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 - 36 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 10 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e360 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAccessories Supplied\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower cord\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eInstruction manual\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eApplication software CD\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUSB cable\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote control connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e1688B\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eVariable Output Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 – 18 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eVariable Output Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 – 20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eFull Load Input Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e4.6 A (100 VAC) \/ 2.1 A (230 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e81% (100 VAC) \/ 85% (230 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTracking Overvoltage Protections\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eO\/P 1-5 V: set voltage +2 V; O\/P 5-18 V: set voltage +3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Tracking OVP threshold varies with set voltage band — review the OVP table for the specific model before connecting a sensitive DUT.\u003cstrong\u003eImportant:\u003c\/strong\u003e All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 23 °C ± 5 °C.\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231625584887,"sku":"bkprec_1688b_new","price":459.0,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49231625617655,"sku":"nist_traceable","price":536.0,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49231625650423,"sku":"nist_traceable_data","price":564.0,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49231625683191,"sku":"17025","price":585.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1688b-new.jpg?v=1735285969"},{"product_id":"6030a-agilent-dc-power-supply-used","title":"Agilent 6030A 1200 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eAgilent 6030A 1200 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutoranging output delivers maximum power across a wide range of voltage and current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-output configurations covering 0–20 V to 0–500 V and currents up to 120 A across the series\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower levels from 200 W (6033A, 6038A) to 1200 W (6010A, 6012B, 6030A, 6032A) across the family\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eGPIB-equipped models (6030A–6038A) support SCPI commands and VXIPlug\u0026amp;Play drivers for system integration\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUp to 16 GPIB units can be connected through one GPIB address via serial link\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAnalog modulation input accepts 0 to 5 V or 0 to 4 kΩ for external programming of voltage and current\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote sensing supports up to 2 V drop in each lead per datasheet specifications\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEither output terminal can be grounded or floated from chassis ground within rated dc floating voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 Series Autoranging DC Power Supplies are single-output bench and system power supplies designed to deliver maximum power across a variety of operating points rather than at a single fixed voltage and current pair. The autoranging output characteristic allows one supply to cover a wide span of voltage and current combinations, which the datasheet describes as taking the place of multiple fixed-range power supplies on a test bench or in a test system. The non-GPIB 6010A, 6011A, 6012B, and 6015A models use ten-turn front panel pots for precise local control, while the GPIB-equipped 6030A through 6038A models add SCPI command compatibility and VXIPlug\u0026amp;Play drivers for integration into automated test systems.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, these supplies are intended to save rack space by using fewer outputs, reduce cost by using fewer power supplies, and — for the non-GPIB models — provide control with external voltage through the analog modulation input. The GPIB models extend this to system-level applications where the datasheet notes that up to 16 power supplies can be connected through one GPIB address via the serial link, and that the supplies have excellent electrical efficiency making them a good choice for large systems. The non-GPIB units can also be connected in auto-parallel or auto-series with their corresponding GPIB unit (6030 Series) as part of a test system.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test \u0026amp; measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement business as Keysight Technologies. Instruments originally branded HP, then Agilent, and now sold or supported by Keysight share a continuous engineering lineage across all three brand names.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 and 6030 Series Autoranging DC Power Supplies are a related family of single-output supplies sharing the same autoranging output architecture. The non-GPIB 6010A, 6011A, 6012B, and 6015A models provide front-panel control with ten-turn pots and an analog modulation input. The GPIB-equipped 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A models add SCPI command compatibility, VXIPlug\u0026amp;Play drivers, and serial-link networking for automated test system integration.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the family, models are differentiated primarily by voltage range, current range, and maximum power. The 1000 W and 1200 W class supplies (6010A, 6011A, 6012B, 6015A, 6030A, 6031A, 6032A, 6035A) cover voltage ranges from 0–20 V up to 0–500 V depending on the model, while the 200 W class supplies (6033A and 6038A) provide lower-power capability in a half-rack form factor. The 6033A and 6038A also offer the Opt 800 rack-mount kit for two half-rack units side by side.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model linked below has its own dedicated product page with pre-owned-matched pricing, current availability, and complete specifications. Click through to the specific model that matches your application's voltage, current, and power requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe primary differentiator within the family is the GPIB and SCPI capability: the 6030 Series adds remote programming, readback, and the ability to network up to 16 supplies through one GPIB address. The non-GPIB 6000 Series models can be auto-paralleled or auto-seried with their corresponding GPIB units as part of a hybrid test system. The 6030 Series also carries a three-year warranty per the datasheet, compared to a one-year warranty on the non-GPIB models.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eVoltage and current ratings vary significantly across the family. Customers needing high voltage at lower currents should consider the 0–500 V models (6015A, 6035A). Customers needing high current at lower voltages should consider the 0–20 V, 0–120 A models (6011A, 6031A). Customers needing mid-range capability with high power should consider the 0–60 V models (6012B, 6032A, 6038A) or the 0–200 V models (6010A, 6030A).\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMaximum Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6030A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6010A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6011A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6012B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e6030A\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V1, I1\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e200 V, 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V2, I2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e120 V, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V3, I3\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e60 V, 17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.035% + 145 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.2% + 25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage rms (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e22 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage p-p\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Current rms\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.08% + 80 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.36% + 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response time (10% step change)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response level\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e4.25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC floating voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±550 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 100 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 120 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 220 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 240 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e16.3 kg (36 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e21.8 kg (48 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Either output terminal can be grounded or floated from chassis ground within the rated dc floating voltage of ±240 V (6011A, 6012B, 6031A, 6032A, 6033A, 6038A) or ±550 V (6010A, 6015A, 6030A, 6035A).\u003cstrong\u003eImportant:\u003c\/strong\u003e A line cord option must be specified for the 6010A, 6011A, 6012B, 6015A (and for the 6030A-32A and 6035A). See pages 93-98 of the Agilent Power Products Catalog for ordering information.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 908 and Opt 909 rack-mount kits require support rails (e.g., E3663AC for Agilent rack cabinets).\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 100 (87 to 106 Vac line input) derates the power supply output to 75%.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt J01 (stabilization for loads up to 10 Henries) is not available on the 6033A.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49728264372471,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49728264405239,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49728264438007,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49728264470775,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6030a_1_1.jpg?v=1735285976"},{"product_id":"9116-b-k-precision-dc-power-supply-new","title":"9116 B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput rating up to 1200 W within 150 V\/ 30A\u003c\/li\u003e\n\u003cli\u003eCompact, high density, 1U rackmount form factor\u003c\/li\u003e\n\u003cli\u003eHigh programming and readback resolution of 1 mV\/1 mA\u003c\/li\u003e\n\u003cli\u003eAdjustable voltage rise and fall times\u003c\/li\u003e\n\u003cli\u003eSequence programming (list mode)\u003c\/li\u003e\n\u003cli\u003eStore and Recall up to 100 instrument settings\u003c\/li\u003e\n\u003cli\u003eStandard USB (USBTMC-compliant), RS-232, GPIB, and RS-485 interfaces supporting SCPI commands for remote control\u003c\/li\u003e\n\u003cli\u003eAnalog interface with control and monitoring functions\u003c\/li\u003e\n\u003cli\u003eRemote sense\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection (OVP), overpower protection (OPP), overtemperature protection (OTP), and key-lock function\u003c\/li\u003e\n\u003cli\u003eSoftpanel for remote control, test sequence generation and data logging. This software also integrates with Data Dashboard for LabVIEW apps enabling iOS, Android or Windows 8 compatible tablets or smart phones to remotely monitor select measurement indicators\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne Year Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eCertificate of calibration and test report\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision 9116 can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings, these multi-range power supplies automatically recalculate voltage and current limits for each setting. The 9116 provides 1200W output power in any Volt\/Amp combination within the rated voltage (150V) and current (30A) limits. By providing greatly expanded choices of maximum power Volt\/Amp combinations, users can cut down on the number of power supplies required and free up valuable bench space.\u003c\/p\u003e\n\u003cp\u003eFor benchtop applications, this model provides a numerical keypad for direct data entry along with convenient cursors and analog style knobs to quickly make incremental voltage or current changes. System integrators benefit from the standard USB (USBTMC-compliant), RS-232, GPIB, and RS-485 interfaces supporting SCPI commands.\u003c\/p\u003e\n\u003cp\u003eAlternatively, users can control the power supply, execute test sequences or log measurements using the provided PC software application. This software also integrates with Data Dashboard for LabVIEW apps enabling iOS, Android or Windows 8 compatible tablets or smart phones to remotely monitor select measurement indicators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Range Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe multi-ranging feature of the 9115 Series offers exceptional flexibility by providing any combination of the rated voltage and current up to the maximum output power of the supply. These wide ranges of voltage and current allow users to replace multiple supplies on a bench or system rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy-to-use interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe numeric keypad, rotary knobs, and cursors provide an easy way to set output levels quickly and precisely. With a push of a button, the display can be conveniently toggled between set and measured voltage and current values.\u003cbr\u003eAdditionally, the power supplies provide internal memory for storage of up to 100 different instrument settings that can be set and recalled via both the front panel and remote interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable voltage rise\/fall times\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power supply is capable of programming the slope of the output voltage during changes between voltage settings by allowing users to set the rising and falling edge times of the voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExternal analog control interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power supply output voltage and current can be controlled from zero to full range by either external DC voltage sources (0-5 V or 0- 10 V) or resistances (0-5 k Ω or 0-10 k Ω). The DB25 analog control interface also provides a source for monitoring the voltage and current output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaster\/Slave operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMore than one unit of the same power supply model can be connected in parallel or series connection to increase the overall current or voltage output respectively. Using the RS-485 interface, the power supplies can operate in master\/slave mode. In this mode, the master unit can control all other power supplies connected in parallel or series. Additionally, the RS-485 interface can be used for multi-unit control of up to 31 daisy chained units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication software\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePC software is provided for front panel emulation, generating and executing test sequences or logging measurement data without the need to write source code.\u003cbr\u003eAdditionally, this application software integrates with NI Data Dashboard for LabVIEW apps which allows users to create a custom dashboard on a tablet computer or smart phone to remotely monitor 9115 Series power supplies via this PC software.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote monitoring on iOS, Android or Windows 8 compatible tablets or smart phones via NI Data Dashboard for LabVIEW apps Quickly develop a custom dashboard consisting of one (smart phone) or several (tablet) indicators, charts or gauges to monitor your power supply\u003c\/li\u003e\n\u003cli\u003eLog voltage, current and power values as well as time stamp, CV\/CC and output status\u003c\/li\u003e\n\u003cli\u003eSave and load list files to\/from the power supply’s internal memory\u003c\/li\u003e\n\u003cli\u003eCreate an unlimited number of external list files to be executed from PC memory. Save and recall list files to\/from the PC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231624044791,"sku":"bkprec_9116_new","price":3050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_9116-new.jpg?v=1735285981"},{"product_id":"6024a-agilent-dc-power-supply-used","title":"6024A Agilent DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 60V\u003c\/li\u003e\n\u003cli\u003eCurrent: 10A\u003c\/li\u003e\n\u003cli\u003ePower: 230W\u003c\/li\u003e\n\u003cli\u003eRegulation: 0.01%\u003c\/li\u003e\n\u003cli\u003eMetered\u003c\/li\u003e\n\u003cli\u003eCV\/CC\u003c\/li\u003e\n\u003cli\u003eProgrammable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Agilent HP 6024A can provide 200 watts over a wide and continuous range of voltage and current combination with maximums of 60 volts and 10 amperes. The Agilent HP 6024A provides greater flexibility than traditional power supplies that have only one maximum power point.\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231637151991,"sku":"agilen_6024a","price":2430.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231637184759,"sku":"nist_traceable","price":2521.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231637217527,"sku":"nist_traceable_data","price":2556.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231637250295,"sku":"17025","price":2605.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6024a.jpg?v=1735285982"},{"product_id":"1711-b-k-precision-dc-power-supply-used","title":"1711 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"featurestext\"\u003e\n\u003cli\u003eOutput Voltage: 0-60 V\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-2A\u003c\/li\u003e\n\u003cli\u003eLargest selection of voltage and current ratings ever offered\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in parallel to double the current output\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in series to double the voltage output\u003c\/li\u003e\n\u003cli\u003eReliable, Durable\u003c\/li\u003e\n\u003cli\u003eOperate continuously at full load without overheating\u003c\/li\u003e\n\u003cli\u003eFully overload protected\u003c\/li\u003e\n\u003cli\u003eCoarse and fine voltage controls\u003c\/li\u003e\n\u003cli\u003eExcellent regulation\u003c\/li\u003e\n\u003cli\u003eVery low ripple\u003c\/li\u003e\n\u003cli\u003eConstant voltage or constant current operation\u003c\/li\u003e\n\u003cli\u003eContinuously monitor voltage and current output on two meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eVoltage Regulation\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eLine (120VAC ±10%): ≤0.01% + 3 mV\u003c\/li\u003e\n\u003cli\u003eLoad (no load - full load):  ≤0.01% + 3 mV\u003c\/li\u003e\n\u003cli\u003eRecovery Time: ≤100 us\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise: ≤1mV rms\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: ≤300 ppm\/0C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eConstant Current Operation\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable Current Range: 5% to 100%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCurrent Regulation\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eLine (120VAC +- 10%): ≤0.2% + 3 mA\u003c\/li\u003e\n\u003cli\u003eLoad: ≤0.2% + 3 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Ripple: ≤3mA rms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Bk Precision 1611 DC Power Supply has an output voltage range of 0-60 Volts and an output current range of 0-2 Amps. The BK Precision 1711 offers constant voltage or constant current operation is reliable and durable.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231625879799,"sku":"bkprec_1711","price":195.0,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49231625912567,"sku":"nist_traceable","price":288.5,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49231625945335,"sku":"nist_traceable_data","price":305.5,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49231625978103,"sku":"17025","price":348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1711.jpg?v=1735285984"},{"product_id":"6033a-agilent-dc-power-supply-used","title":"Agilent 6033A 242 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eAgilent 6033A 242 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutoranging output delivers maximum power across a wide range of voltage and current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-output configurations covering 0–20 V to 0–500 V and currents up to 120 A across the series\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower levels from 200 W (6033A, 6038A) to 1200 W (6010A, 6012B, 6030A, 6032A) across the family\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eGPIB-equipped models (6030A–6038A) support SCPI commands and VXIPlug\u0026amp;Play drivers for system integration\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUp to 16 GPIB units can be connected through one GPIB address via serial link\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAnalog modulation input accepts 0 to 5 V or 0 to 4 kΩ for external programming of voltage and current\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote sensing supports up to 2 V drop in each lead per datasheet specifications\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEither output terminal can be grounded or floated from chassis ground within rated dc floating voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 Series Autoranging DC Power Supplies are single-output bench and system power supplies designed to deliver maximum power across a variety of operating points rather than at a single fixed voltage and current pair. The autoranging output characteristic allows one supply to cover a wide span of voltage and current combinations, which the datasheet describes as taking the place of multiple fixed-range power supplies on a test bench or in a test system. The non-GPIB 6010A, 6011A, 6012B, and 6015A models use ten-turn front panel pots for precise local control, while the GPIB-equipped 6030A through 6038A models add SCPI command compatibility and VXIPlug\u0026amp;Play drivers for integration into automated test systems.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, these supplies are intended to save rack space by using fewer outputs, reduce cost by using fewer power supplies, and — for the non-GPIB models — provide control with external voltage through the analog modulation input. The GPIB models extend this to system-level applications where the datasheet notes that up to 16 power supplies can be connected through one GPIB address via the serial link, and that the supplies have excellent electrical efficiency making them a good choice for large systems. The non-GPIB units can also be connected in auto-parallel or auto-series with their corresponding GPIB unit (6030 Series) as part of a test system.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test \u0026amp; measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement business as Keysight Technologies. Instruments originally branded HP, then Agilent, and now sold or supported by Keysight share a continuous engineering lineage across all three brand names.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 and 6030 Series Autoranging DC Power Supplies are a related family of single-output supplies sharing the same autoranging output architecture. The non-GPIB 6010A, 6011A, 6012B, and 6015A models provide front-panel control with ten-turn pots and an analog modulation input. The GPIB-equipped 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A models add SCPI command compatibility, VXIPlug\u0026amp;Play drivers, and serial-link networking for automated test system integration.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the family, models are differentiated primarily by voltage range, current range, and maximum power. The 1000 W and 1200 W class supplies (6010A, 6011A, 6012B, 6015A, 6030A, 6031A, 6032A, 6035A) cover voltage ranges from 0–20 V up to 0–500 V depending on the model, while the 200 W class supplies (6033A and 6038A) provide lower-power capability in a half-rack form factor. The 6033A and 6038A also offer the Opt 800 rack-mount kit for two half-rack units side by side.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model linked below has its own dedicated product page with pre-owned-matched pricing, current availability, and complete specifications. Click through to the specific model that matches your application's voltage, current, and power requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe primary differentiator within the family is the GPIB and SCPI capability: the 6030 Series adds remote programming, readback, and the ability to network up to 16 supplies through one GPIB address. The non-GPIB 6000 Series models can be auto-paralleled or auto-seried with their corresponding GPIB units as part of a hybrid test system. The 6030 Series also carries a three-year warranty per the datasheet, compared to a one-year warranty on the non-GPIB models.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eVoltage and current ratings vary significantly across the family. Customers needing high voltage at lower currents should consider the 0–500 V models (6015A, 6035A). Customers needing high current at lower voltages should consider the 0–20 V, 0–120 A models (6011A, 6031A). Customers needing mid-range capability with high power should consider the 0–60 V models (6012B, 6032A, 6038A) or the 0–200 V models (6010A, 6030A).\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMaximum Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6033A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 30 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e242 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6010A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6011A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6012B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e6033A\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e242 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V1, I1\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e20 V, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V2, I2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 V, 17.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V3, I3\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6.7 V, 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.035% + 9 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.15% + 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage rms (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage p-p\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e30 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Current rms\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.07% + 6 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.3% + 25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 9 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response time (10% step change)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response level\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e7.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC floating voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 100 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 120 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 220 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e3.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 240 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e3.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e9.6 kg (21 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e11.4 kg (25 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Either output terminal can be grounded or floated from chassis ground within the rated dc floating voltage of ±240 V (6011A, 6012B, 6031A, 6032A, 6033A, 6038A) or ±550 V (6010A, 6015A, 6030A, 6035A).\u003cstrong\u003eImportant:\u003c\/strong\u003e A line cord option must be specified for the 6010A, 6011A, 6012B, 6015A (and for the 6030A-32A and 6035A). See pages 93-98 of the Agilent Power Products Catalog for ordering information.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 908 and Opt 909 rack-mount kits require support rails (e.g., E3663AC for Agilent rack cabinets).\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 100 (87 to 106 Vac line input) derates the power supply output to 75%.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt J01 (stabilization for loads up to 10 Henries) is not available on the 6033A.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231621226743,"sku":"agilen_6033a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231621259511,"sku":"nist_traceable","price":210.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231621292279,"sku":"nist_traceable_data","price":280.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231621325047,"sku":"17025","price":350.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6033a.jpg?v=1735285986"},{"product_id":"1743b-b-k-precision-dc-power-supply-new","title":"1743B B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0-35 V\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-4 A\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in parallel to double the current output\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in series to double the voltage output\u003c\/li\u003e\n\u003cli\u003eReliable, Durable\u003c\/li\u003e\n\u003cli\u003eOperate continuously at full load without overheating\u003c\/li\u003e\n\u003cli\u003eFully overload protected\u003c\/li\u003e\n\u003cli\u003eCoarse and fine voltage controls\u003c\/li\u003e\n\u003cli\u003eExcellent regulation\u003c\/li\u003e\n\u003cli\u003eVery low ripple\u003c\/li\u003e\n\u003cli\u003eConstant voltage or constant current operation\u003c\/li\u003e\n\u003cli\u003eIncluded Accessories: Instruction manual, spare fuse and power cord\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2-Year Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cb\u003eConstant Voltage Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Regulation: Line (120 VAC ±10%) \u0026lt;0.2% + 2 mV; Load (no load - full load) \u0026lt;0.04% + 2 mV\u003c\/li\u003e\n\u003cli\u003eRecovery Time:  \u0026lt;100 μs\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise: 1 mV rms (Typical)\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: \u0026lt;300 ppm\/°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eConstant Current Operation\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable Current Limit: 5% to 100%\u003c\/li\u003e\n\u003cli\u003eCurrent Regulation: Line (120 VAC ±10%) \u0026lt;0.4% + 5 mA; Load \u0026lt;0.4% + 5 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Ripple: \u0026lt;3 mArms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMetering\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: Dual 4-digit LED\u003c\/li\u003e\n\u003cli\u003eVoltmeter Range: 0-99.99 V (green)\u003c\/li\u003e\n\u003cli\u003e Voltmeter Accuracy: ± (0.5% + 9 digits)\u003c\/li\u003e\n\u003cli\u003eAmmeter Range: 0-9.999 A (red)\u003c\/li\u003e\n\u003cli\u003eAmmeter Accuracy: ± (0.5% + 9 digits)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eGeneral\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload Protection: Current limiting, reverse polarity, overvoltage, short circuit\u003c\/li\u003e\n\u003cli\u003eAC Input: 120\/220 VAC ±10%, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 450 W\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 32 to 104 °F (0 to 40 °C), \u0026lt;75% R.H.\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: 5 to 158 °F (-15 to +70 °C), \u0026lt;85% R.H.\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 5.7” x 10.5” x 15” (145 x 267 x 381 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision 1743B DC Power Supply is a high quality general purpose DC power source. The power supply provides 0-35 volts DC output, adjustable with both coarse and fine controls for precise settability. The BK 1743B current output is 0-6 amps, adjustable with both coarse and fine current controls. Two large LED meters continuously monitor the output voltage and current. The VOLTAGE meter is green, while the Current, meter is red.\u003cbr\u003e \u003cbr\u003e The 1743B power supply exhibits excellent regulation and low ripple characteristeics. The circuit design incorporates a pre-regulator, which greatly reduces internal power dissipation at low output voltages. The styling is both attractive and functional.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231622766839,"sku":"bkprec_1743b_new","price":790.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1743b_l.jpg?v=1735285988"},{"product_id":"1761-b-k-precision-dc-power-supply-used","title":"1761 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0-35V (A \u0026amp; B), 2-6.5 V (C)\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-3A (A \u0026amp; B), 5A (C)\u003c\/li\u003e\n\u003cli\u003eConstant voltage (CV) and constant current (CC) operation\u003c\/li\u003e\n\u003cli\u003eIndependent or series tracking\/parallel mode operation to double voltage or current\u003c\/li\u003e\n\u003cli\u003eCoarse and fine voltage controls\u003c\/li\u003e\n\u003cli\u003eAdjustable current limiting\u003c\/li\u003e\n\u003cli\u003eExcellent regulation\u003c\/li\u003e\n\u003cli\u003eVery low ripple\u003c\/li\u003e\n\u003cli\u003eDesigned to operate continuously at rated output\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection and reverse polarity protection\u003c\/li\u003e\n\u003cli\u003ecUL Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision 1761 Triple Output DC Power Supply offers outputs with two 0 to 35V, 0 to 3A and one 2 to 6.5V, 5A outputs. The 1761 includes 4 digit LED displays that are 10mV and 1mA resolution which provides higher accuracy and continuously monitors voltage and current output.\u003cbr\u003e \u003cbr\u003e With the BK 1761 you can connect two supplies in parallel to double the current output or connect two supplies in series to double the voltage output. The unit operates continuously at full load without overheating.\u003c\/p\u003e\n\u003cp\u003eThese power supplies also provide overload and reverse polarity protection.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231626666231,"sku":"bkprec_1761","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231626698999,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231626731767,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231626764535,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1761_1.jpg?v=1735285990"},{"product_id":"1660-b-k-precision-dc-power-supply-used","title":"1660 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaster and Slave Supplies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage Range: 0 V (+0\/-30 mV) to 30 V + 3% to 7%)\u003c\/li\u003e\n\u003cli\u003eOutput Current Limit Range: 0 A (+0\/-30 mA) to 2 A +(3% to 7%)\u003c\/li\u003e\n\u003cli\u003eLoad Regulation (Constant Voltage): ≤ 0.01% + 3 mV\u003c\/li\u003e\n\u003cli\u003eLine Regulation 108-132 V (Constant Voltage): ≤0.01% + 3 mV\u003c\/li\u003e\n\u003cli\u003eRipple (Constant Voltage): ≤ 1 mV RMS\u003c\/li\u003e\n\u003cli\u003eRecovery Time (Constant Voltage) 100 U S\u003c\/li\u003e\n\u003cli\u003eTemp. Coefficient (Constant Voltage): ≤ 300 ppm\/DEG C\u003c\/li\u003e\n\u003cli\u003eLoad Regulation (Constant Current); ≤ 0.2% + 3mA\u003c\/li\u003e\n\u003cli\u003eLine Regulation 108-132 V (Constant Current): ≤ 0.2% + 3mA\u003c\/li\u003e\n\u003cli\u003eRipple Current (at 108 V for Constant Current): ≤ 3 mA RMS\u003c\/li\u003e\n\u003cli\u003eTracking (Series): ±0.2% + 10 mV\u003c\/li\u003e\n\u003cli\u003ePanel Meter Accuracy (Volts): ±0.5% + 2 digits\u003c\/li\u003e\n\u003cli\u003ePanel Meter Accuracy (Current): ± 0.5% + 2 digits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4-6.5 V Supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage Range: 4 V ≤ 5% to 6.5 V ± 5%\u003c\/li\u003e\n\u003cli\u003eLoad Regulation (Constant Voltage): ≤10 mV (0 to 5 A load)\u003c\/li\u003e\n\u003cli\u003eLine Regulation 108-132 V (Constant Voltage): ≤ 10 m V\u003c\/li\u003e\n\u003cli\u003eRipple and Noise: ≤2 mV RMS\u003c\/li\u003e\n\u003cli\u003eOvervoltage Protection Threshold: 6.8 V to 7.3 V\u003c\/li\u003e\n\u003cli\u003ePanel Meter Accuracy: Same as Master Supply Meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Requirements: 110\/120\/220\/240 VAC ± 10%, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Consumption (Fully Loaded): Approximately 320 W\u003c\/li\u003e\n\u003cli\u003eProtection: Reverse polarity protection and current limiting\u003c\/li\u003e\n\u003cli\u003eDimensions: 165 x 315 x 381 mm (12.4 x 15 x 6.5\")\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe BK Precision 1660 Triple Output DC Power Supply is a high quality, general purpose dc power source. It provides two supplies with a 0-30 volt dc output and one with a 4-6.5 volt dc output. The 0-30 V supplies are adjustable with both coarse and fine voltage controls for precise settability and are capable of current output of 0-2 amps. The 4-6.5 V supply has a current output of 0-5 amps, allowing it to handle extensive digital logic circuitry. Two large panel-mounted LED meter displays can monitor either the output current or output voltage of each supply.\u003c\/p\u003e\n\u003cp\u003eThe two 0-30 volt supplies can be operated independently or in one of two tracking modes. In the series tracking mode, the Slave supply tracks the voltage of the Master supply. Maximum current setting of the two supplies can still be set independently when in the series tracking operating mode. In the series tracking mode the Master and Slave supplies are connected in series, allowing a single output of 0-60 V at up to 2 amps. In the parallel tracking mode, the two supplies are connected together in parallel, allowing a single 0-30 V output at up to 4 amps.\u003c\/p\u003e\n\u003cp\u003eBoth 0-30 volt supplies may be used in constant voltage or constant current applications. The crossover from constant voltage ot constant current modes is smooth and automatic. LED's indicate the \"CV\" (constant voltage) or \"CC\" (constant current) mode of operation. In constant voltage applications, a current limit may be preset. When load variations cause the current to reach the preset limit, the unit then regulated output current rather than output voltage. Current limits are adjustable from 5% to 100% of maximum. In constant current applications, the maximum voltage may be preset. When load variations cause current to drop below the regulated value, the unit reverts to regulated voltage operation at the preset value.\u003c\/p\u003e\n\u003cp\u003eThe 4-6.5 V supply is ideal for powering digital logic circuitry. The 0-5 amp capacity allows the supply to be used for large circuits. Built-in overload protection automatically limits to current output to a maximum of 5 amps. An indicator lights when the supply is overloaded.\u003c\/p\u003e\n\u003cp\u003eThe Model 1660 exhibits excellent regulation and low ripple characteristics. The circuit design incorporates a pre-regulator, which greatly reduces internal power dissipation at low output voltages.\u003c\/p\u003e\n\u003cp\u003eReverse polarity protection prevents accidental damage to the power supply from improper connection to an external voltage, and current limiting protects the equipment being powered, as well as the power supply.\u003c\/p\u003e\n\u003cp\u003eThe output is isolated from chassis and earth ground, which permits full flexibility of connections. When needed, the (+) or (-) polarity may be strapped to ground, or either polarity may be floated to an external voltage. Additionally, the two 0-30 volt supplies can be used as a \"split supply\" with two positive voltages and a common negative, two negative voltages and a common positive, or one positive, one negative, and a common. All of these configurations can be used with either matching (tracking) or differing (independent) voltages.\u003c\/p\u003e\n\u003cp\u003eThe features and versatility of the unit, especially the triple output and tracking features, make it an ideal general purpose power supply for engineering lab applications. It can serve as a single or multi-voltage power source, including the bias supply, for breadboard and prototype circuits and equipment. It can provide single or simultaneously varying voltages for circuit evaluation. It can provide tracking (+) and (-) voltages for evaluating differential amplifiers. It may be used as a battery eliminator, or to power individual circuit boards or cards while removed from the system. Its output cam be evaluated while powering a breadboard or prototype circuit to determine the circuit's power supply requirements. Its laboratory quality specifications will meet most engineering laboratory requirements.\u003c\/p\u003e\n\u003cp\u003eThe same features that make the Model 1660 a good choice for an engineering lab also make it a good choice for most other solid state electronic applications. These applications include service shops; industrial production testing of components, assemblies, and complete equipment; for school laboratories, and home use by electronic hobbyists.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231627026679,"sku":"bkprec_1660","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231627059447,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231627092215,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231627124983,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1660_1.jpg?v=1735285993"},{"product_id":"6035a-agilent-dc-power-supply-used","title":"Agilent 6035A 1050 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eAgilent 6035A 1050 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutoranging output delivers maximum power across a wide range of voltage and current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-output configurations covering 0–20 V to 0–500 V and currents up to 120 A across the series\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower levels from 200 W (6033A, 6038A) to 1200 W (6010A, 6012B, 6030A, 6032A) across the family\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eGPIB-equipped models (6030A–6038A) support SCPI commands and VXIPlug\u0026amp;Play drivers for system integration\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUp to 16 GPIB units can be connected through one GPIB address via serial link\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAnalog modulation input accepts 0 to 5 V or 0 to 4 kΩ for external programming of voltage and current\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote sensing supports up to 2 V drop in each lead per datasheet specifications\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEither output terminal can be grounded or floated from chassis ground within rated dc floating voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 Series Autoranging DC Power Supplies are single-output bench and system power supplies designed to deliver maximum power across a variety of operating points rather than at a single fixed voltage and current pair. The autoranging output characteristic allows one supply to cover a wide span of voltage and current combinations, which the datasheet describes as taking the place of multiple fixed-range power supplies on a test bench or in a test system. The non-GPIB 6010A, 6011A, 6012B, and 6015A models use ten-turn front panel pots for precise local control, while the GPIB-equipped 6030A through 6038A models add SCPI command compatibility and VXIPlug\u0026amp;Play drivers for integration into automated test systems.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, these supplies are intended to save rack space by using fewer outputs, reduce cost by using fewer power supplies, and — for the non-GPIB models — provide control with external voltage through the analog modulation input. The GPIB models extend this to system-level applications where the datasheet notes that up to 16 power supplies can be connected through one GPIB address via the serial link, and that the supplies have excellent electrical efficiency making them a good choice for large systems. The non-GPIB units can also be connected in auto-parallel or auto-series with their corresponding GPIB unit (6030 Series) as part of a test system.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test \u0026amp; measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement business as Keysight Technologies. Instruments originally branded HP, then Agilent, and now sold or supported by Keysight share a continuous engineering lineage across all three brand names.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 and 6030 Series Autoranging DC Power Supplies are a related family of single-output supplies sharing the same autoranging output architecture. The non-GPIB 6010A, 6011A, 6012B, and 6015A models provide front-panel control with ten-turn pots and an analog modulation input. The GPIB-equipped 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A models add SCPI command compatibility, VXIPlug\u0026amp;Play drivers, and serial-link networking for automated test system integration.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the family, models are differentiated primarily by voltage range, current range, and maximum power. The 1000 W and 1200 W class supplies (6010A, 6011A, 6012B, 6015A, 6030A, 6031A, 6032A, 6035A) cover voltage ranges from 0–20 V up to 0–500 V depending on the model, while the 200 W class supplies (6033A and 6038A) provide lower-power capability in a half-rack form factor. The 6033A and 6038A also offer the Opt 800 rack-mount kit for two half-rack units side by side.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model linked below has its own dedicated product page with pre-owned-matched pricing, current availability, and complete specifications. Click through to the specific model that matches your application's voltage, current, and power requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe primary differentiator within the family is the GPIB and SCPI capability: the 6030 Series adds remote programming, readback, and the ability to network up to 16 supplies through one GPIB address. The non-GPIB 6000 Series models can be auto-paralleled or auto-seried with their corresponding GPIB units as part of a hybrid test system. The 6030 Series also carries a three-year warranty per the datasheet, compared to a one-year warranty on the non-GPIB models.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eVoltage and current ratings vary significantly across the family. Customers needing high voltage at lower currents should consider the 0–500 V models (6015A, 6035A). Customers needing high current at lower voltages should consider the 0–20 V, 0–120 A models (6011A, 6031A). Customers needing mid-range capability with high power should consider the 0–60 V models (6012B, 6032A, 6038A) or the 0–200 V models (6010A, 6030A).\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMaximum Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6035A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 500 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 5 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,050 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6010A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6011A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6012B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e6035A\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,050 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V1, I1\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e500 V, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V2, I2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e350 V, 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V3, I3\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e200 V, 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.25% + 400 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.3% + 63 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage rms (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage p-p\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e160 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Current rms\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.5% + 300 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.5% + 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 13 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 13 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 18 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response time (10% step change)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response level\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e200 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e125 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1.25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC floating voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±550 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 100 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 120 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 220 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 240 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e16.3 kg (36 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e21.8 kg (48 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Either output terminal can be grounded or floated from chassis ground within the rated dc floating voltage of ±240 V (6011A, 6012B, 6031A, 6032A, 6033A, 6038A) or ±550 V (6010A, 6015A, 6030A, 6035A).\u003cstrong\u003eImportant:\u003c\/strong\u003e A line cord option must be specified for the 6010A, 6011A, 6012B, 6015A (and for the 6030A-32A and 6035A). See pages 93-98 of the Agilent Power Products Catalog for ordering information.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 908 and Opt 909 rack-mount kits require support rails (e.g., E3663AC for Agilent rack cabinets).\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 100 (87 to 106 Vac line input) derates the power supply output to 75%.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt J01 (stabilization for loads up to 10 Henries) is not available on the 6033A.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231625355511,"sku":"agilen_6035a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231625388279,"sku":"nist_traceable","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231625421047,"sku":"nist_traceable_data","price":0.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231625453815,"sku":"17025","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6035a.jpg?v=1735285995"},{"product_id":"9115-b-k-precision-dc-power-supply-new","title":"9115 B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput up to 1200 W within 80 V\/ 60 A rating\u003c\/li\u003e\n\u003cli\u003eCompact, high density, 1U rackmount form factor\u003c\/li\u003e\n\u003cli\u003eHigh programming and readback resolution of 1 mV\/1 mA\u003c\/li\u003e\n\u003cli\u003eAdjustable voltage rise and fall times\u003c\/li\u003e\n\u003cli\u003eSequence programming (list mode)\u003c\/li\u003e\n\u003cli\u003eStore and Recall up to 100 instrument settings\u003c\/li\u003e\n\u003cli\u003eStandard USB (USBTMC-compliant), RS-232, GPIB, and RS-485 interfaces supporting SCPI commands for remote control\u003c\/li\u003e\n\u003cli\u003eAnalog interface with control and monitoring functions\u003c\/li\u003e\n\u003cli\u003eMater\/Slave mode for parallel and series operation\u003c\/li\u003e\n\u003cli\u003eRemote sense\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection (OVP), overpower protection (OPP), overtemperature protection (OTP), and key-lock function\u003c\/li\u003e\n\u003cli\u003eSoftpanel for remote control, test sequency generation and data logging\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne Year Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Accessories:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eCertificate of calibration and test report\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 9115 can replace multiple supplies on your bench or in your rack. Unlike conventional power supplies with fixed output ratings, the 9115 automatically recalculates voltage\/current limits for each setting. The 9115 provides 1200W output power in any Volt\/Amp combination within the rated voltage (80V) and current (60A) limits. By providing greatly expanded choices of maximum power Volt\/Amp combinations, users can cut down on the number of power supplies required and free up valuable bench space.\u003c\/p\u003e\n\u003cp\u003eFor benchtop applications, this series provides a numerical keypad for direct data entry along with convenient cursors and analog style knobs to quickly make incremental voltage or current changes. System integrators benefit from the standard USB (USBTMC-compliant), RS-232, GPIB, RS-485, and LAN (9117 only) interfaces supporting SCPI commands.\u003c\/p\u003e\n\u003cp\u003eAlternatively, users can control the power supply, execute test sequences or log measurements using the provided PC software application. This software also integrates with Data Dashboard for LabVIEW apps enabling iOS, Android or Windows 8 compatible tablets or smart phones to remotely monitor select measurement indicators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Range Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe multi-ranging feature of the 9115 Series offers exceptional flexibility by providing any combination of the rated voltage and current up to the maximum output power of the supply. These wide ranges of voltage and current allow users to replace multiple supplies on a bench or system rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy-to-use interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe numeric keypad, rotary knobs, and cursors provide an easy way to set output levels quickly and precisely. With a push of a button, the display can be conveniently toggled between set and measured voltage and current values.\u003cbr\u003eAdditionally, the power supplies provide internal memory for storage of up to 100 different instrument settings that can be set and recalled via both the front panel and remote interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable voltage rise\/fall times\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power supply is capable of programming the slope of the output voltage during changes between voltage settings by allowing users to set the rising and falling edge times of the voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExternal analog control interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe power supply output voltage and current can be controlled from zero to full range by either external DC voltage sources (0-5 V or 0- 10 V) or resistances (0-5 k Ω or 0-10 k Ω). The DB25 analog control interface also provides a source for monitoring the voltage and current output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaster\/Slave operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMore than one unit of the same power supply model can be connected in parallel or series connection to increase the overall current or voltage output respectively. Using the RS-485 interface, the power supplies can operate in master\/slave mode. In this mode, the master unit can control all other power supplies connected in parallel or series. Additionally, the RS-485 interface can be used for multi-unit control of up to 31 daisy chained units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication software\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePC software is provided for front panel emulation, generating and executing test sequences or logging measurement data without the need to write source code.\u003cbr\u003eAdditionally, this application software integrates with NI Data Dashboard for LabVIEW apps which allows users to create a custom dashboard on a tablet computer or smart phone to remotely monitor 9115 Series power supplies via this PC software.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote monitoring on iOS, Android or Windows 8 compatible tablets or smart phones via NI Data Dashboard for LabVIEW apps Quickly develop a custom dashboard consisting of one (smart phone) or several (tablet) indicators, charts or gauges to monitor your power supply\u003c\/li\u003e\n\u003cli\u003eLog voltage, current and power values as well as time stamp, CV\/CC and output status\u003c\/li\u003e\n\u003cli\u003eSave and load list files to\/from the power supply’s internal memory\u003c\/li\u003e\n\u003cli\u003eCreate an unlimited number of external list files to be executed from PC memory. Save and recall list files to\/from the PC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231635284215,"sku":"bkprec_9115_new","price":2770.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_9115-new.jpg?v=1735285997"},{"product_id":"6012b-agilent-dc-power-supply-used","title":"Agilent 6012B 1200 W Single-Output Autoranging DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eAgilent 6012B 1200 W Single-Output Autoranging DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutoranging output delivers maximum power across a wide range of voltage and current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-output configurations covering 0–20 V to 0–500 V and currents up to 120 A across the series\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower levels from 200 W (6033A, 6038A) to 1200 W (6010A, 6012B, 6030A, 6032A) across the family\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eGPIB-equipped models (6030A–6038A) support SCPI commands and VXIPlug\u0026amp;Play drivers for system integration\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUp to 16 GPIB units can be connected through one GPIB address via serial link\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAnalog modulation input accepts 0 to 5 V or 0 to 4 kΩ for external programming of voltage and current\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote sensing supports up to 2 V drop in each lead per datasheet specifications\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEither output terminal can be grounded or floated from chassis ground within rated dc floating voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 Series Autoranging DC Power Supplies are single-output bench and system power supplies designed to deliver maximum power across a variety of operating points rather than at a single fixed voltage and current pair. The autoranging output characteristic allows one supply to cover a wide span of voltage and current combinations, which the datasheet describes as taking the place of multiple fixed-range power supplies on a test bench or in a test system. The non-GPIB 6010A, 6011A, 6012B, and 6015A models use ten-turn front panel pots for precise local control, while the GPIB-equipped 6030A through 6038A models add SCPI command compatibility and VXIPlug\u0026amp;Play drivers for integration into automated test systems.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, these supplies are intended to save rack space by using fewer outputs, reduce cost by using fewer power supplies, and — for the non-GPIB models — provide control with external voltage through the analog modulation input. The GPIB models extend this to system-level applications where the datasheet notes that up to 16 power supplies can be connected through one GPIB address via the serial link, and that the supplies have excellent electrical efficiency making them a good choice for large systems. The non-GPIB units can also be connected in auto-parallel or auto-series with their corresponding GPIB unit (6030 Series) as part of a test system.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test \u0026amp; measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement business as Keysight Technologies. Instruments originally branded HP, then Agilent, and now sold or supported by Keysight share a continuous engineering lineage across all three brand names.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 and 6030 Series Autoranging DC Power Supplies are a related family of single-output supplies sharing the same autoranging output architecture. The non-GPIB 6010A, 6011A, 6012B, and 6015A models provide front-panel control with ten-turn pots and an analog modulation input. The GPIB-equipped 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A models add SCPI command compatibility, VXIPlug\u0026amp;Play drivers, and serial-link networking for automated test system integration.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the family, models are differentiated primarily by voltage range, current range, and maximum power. The 1000 W and 1200 W class supplies (6010A, 6011A, 6012B, 6015A, 6030A, 6031A, 6032A, 6035A) cover voltage ranges from 0–20 V up to 0–500 V depending on the model, while the 200 W class supplies (6033A and 6038A) provide lower-power capability in a half-rack form factor. The 6033A and 6038A also offer the Opt 800 rack-mount kit for two half-rack units side by side.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model linked below has its own dedicated product page with pre-owned-matched pricing, current availability, and complete specifications. Click through to the specific model that matches your application's voltage, current, and power requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe primary differentiator within the family is the GPIB and SCPI capability: the 6030 Series adds remote programming, readback, and the ability to network up to 16 supplies through one GPIB address. The non-GPIB 6000 Series models can be auto-paralleled or auto-seried with their corresponding GPIB units as part of a hybrid test system. The 6030 Series also carries a three-year warranty per the datasheet, compared to a one-year warranty on the non-GPIB models.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eVoltage and current ratings vary significantly across the family. Customers needing high voltage at lower currents should consider the 0–500 V models (6015A, 6035A). Customers needing high current at lower voltages should consider the 0–20 V, 0–120 A models (6011A, 6031A). Customers needing mid-range capability with high power should consider the 0–60 V models (6012B, 6032A, 6038A) or the 0–200 V models (6010A, 6030A).\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMaximum Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6012B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6010A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6011A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6015A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 500 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 5 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,050 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e6012B\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V1, I1\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e60 V, 17.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V2, I2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e40 V, 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V3, I3\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e20 V, 50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage rms (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e8 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage p-p\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e40 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Current rms\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response time (10% step change)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response level\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e12.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC floating voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 100 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 120 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 220 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 240 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e16.3 kg (36 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e21.8 kg (48 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Either output terminal can be grounded or floated from chassis ground within the rated dc floating voltage of ±240 V (6011A, 6012B, 6031A, 6032A, 6033A, 6038A) or ±550 V (6010A, 6015A, 6030A, 6035A).\u003cstrong\u003eImportant:\u003c\/strong\u003e A line cord option must be specified for the 6010A, 6011A, 6012B, 6015A (and for the 6030A-32A and 6035A). See pages 93-98 of the Agilent Power Products Catalog for ordering information.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 908 and Opt 909 rack-mount kits require support rails (e.g., E3663AC for Agilent rack cabinets).\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 100 (87 to 106 Vac line input) derates the power supply output to 75%.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt J01 (stabilization for loads up to 10 Henries) is not available on the 6033A.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231615131895,"sku":"agilen_6012b","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231615164663,"sku":"nist_traceable","price":210.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231615197431,"sku":"nist_traceable_data","price":280.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231615230199,"sku":"17025","price":315.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6012b.jpg?v=1735285999"},{"product_id":"1785-b-k-precision-dc-power-supply-used","title":"1785 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNine user-programmable preset outputs\u003c\/li\u003e\n\u003cli\u003eTen step user-programmable output routine\u003c\/li\u003e\n\u003cli\u003e.02% + 5 mV regulation\u003c\/li\u003e\n\u003cli\u003e1 mV ripple and noise (RMS)\u003c\/li\u003e\n\u003cli\u003eIn-case calibration\u003c\/li\u003e\n\u003cli\u003eSerial interface cable \/ software included\u003c\/li\u003e\n\u003cli\u003e3 digit LED display volt and amp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BK Precision 1785, Programmable Power Supply, has direct key-in entry for fast, accurate voltage and current selection. Preprogram output via the keypad or PC interface. Both Windows and DOS software.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231624175863,"sku":"bkprec_1785","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231624208631,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231624241399,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231624274167,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1785_1.jpg?v=1735286000"},{"product_id":"6113a-agilent-dc-power-supply-used","title":"HP 6113A Precision Voltage Source (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eHP 6113A Precision Voltage Source (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePrecision DC voltage source with thumbwheel voltage control for convenient, precise output adjustment\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003e0.1% output voltage accuracy with 0-20V output range\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFive-decade thumbwheel voltage programmer for precise resettable output settings\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-turn current control allows full-range adjustment of the current-limit point\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eConstant Voltage \/ Constant Current Limit (CV\/CL) operation mode\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003e20 watt output at 0-20V, 0-1A — 115 V AC ± 10%, 43-63 Hz input (230V available via Option 028)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eCompact form factor at 133 H x 216 W x 318 mm D (5.25 x 8.5 x 12.5 inches)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe HP 6111A is a precision DC voltage source designed for laboratory and engineering applications requiring an accurate, stable, and easy-to-use source of DC voltage. As part of the 6111A-6116A precision voltage source family, the 6111A delivers 0-20V output at 0-1A with 0.1% output voltage accuracy, making it well-suited for applications where precise, repeatable voltage settings are required.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eOutput voltage on the 6111A is adjusted using a five-decade thumbwheel voltage programmer, which provides convenient and precise output voltage adjustment. A single-turn current control allows full-range adjustment of the current-limit point, supporting Constant Voltage \/ Constant Current Limit (CV\/CL) operation. This configuration is suitable for powering precision circuits, calibration setups, and laboratory work where settable voltage accuracy is the primary requirement.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eValueTronics International has specialized in legacy and current-generation Hewlett-Packard test and measurement equipment since 1992. Each instrument that passes through our 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois receives hands-on inspection and functional verification by our technical team — not a drop-shipped catalog listing. For an instrument family like the 6111A precision voltage sources, where HP's manufacturer support has ended, that hands-on verification is the difference between a working precision source ready for bench use and an unknown-condition unit from an unverified marketplace listing.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test and measurement business was spun out as Agilent Technologies in 1999, and Agilent's electronic measurement business was transferred to Keysight Technologies in 2014. The HP 6111A and the broader 6111A-6116A precision voltage source family are HP-era instruments that predate both transitions. Manufacturer support and current-production equivalents now reside within the Keysight catalog where applicable, though the original HP-branded units retain active demand in legacy calibration labs and bench setups built around them.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe 6111A-6116A precision voltage source family consists of six precision DC voltage sources covering a range of output voltages and currents, with two distinct performance tiers. The 6114A and 6115A are the High Performance Precision Source models, offering 0.025% output voltage accuracy and CV\/CC (Constant Voltage \/ Constant Current) operation with automatic dual range, pushbutton voltage controls, and 40 watt output capability. The 6111A, 6112A, 6113A, and 6116A models offer 0.1% output voltage accuracy and CV\/CL (Constant Voltage \/ Constant Current Limit) operation with thumbwheel voltage programmers and 20 watt output capability.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAll six models in the family share the same fundamental architecture as precision DC voltage sources designed for applications where accurate, stable, easy-to-use DC voltage is required. They differ in output voltage range, output current capability, accuracy tier, and operating mode (CV\/CC versus CV\/CL).\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach pre-owned model in the 6111A-6116A family below is its own dedicated product page with condition-matched pricing and availability. Select the page that matches the model number on the instrument you need.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the 6111A-6116A family, the 6111A specifically covers the 0-20V output range at 0-1A output current with 0.1% + 1 mV accuracy, CV\/CL operation, and the thumbwheel voltage programmer architecture. It is the 20V variant of the 20-watt CV\/CL tier in the family.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe six models in the 6111A-6116A family differ primarily by output voltage range, output current, accuracy tier, and operating mode. The 6113A covers 0-10V at 0-2A; the 6111A covers 0-20V at 0-1A; the 6112A covers 0-40V at 0-0.5A; the 6116A covers 0-100V at 0-0.2A — all at 0.1% + 1 mV accuracy with CV\/CL operation. The High Performance Precision Source models offer tighter accuracy: the 6114A covers 0-20V at 0-2A and 20-40V at 0-1A with 0.025% + 1 mV accuracy and CV\/CC operation; the 6115A covers 0-50V at 0-0.8A, 50-100V at 0-0.4A with 0.025% + 1 mV accuracy and CV\/CC operation.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe comparison table that follows lists each model's output ratings, accuracy, resolution, PARD (ripple and noise), source effect, load effect, temperature coefficient, drift, overvoltage protection, and available options as printed on the datasheet — making the within-family selection between the six models straightforward based on the application's voltage range, current requirement, and accuracy tier.\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6113A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-10 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-2 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.1% + 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6111A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-1 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.1% + 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6112A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-40 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-0.5 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.1% + 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6114A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-20 V, 20-40 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-2 A, 0-1 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.025% + 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.1% + 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e20 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003ePARD (rms\/p-p)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e40 µV \/ 100 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eSource Effect\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad Effect\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.001% + 100 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.001% + 10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDrift (Stability)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 100 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOpt 11, 3-13 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOptions Available\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e11, 28, 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eCV\/CL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e115 V ac ± 10%, 43-63 Hz, 0.5 A, 52 W (for 230 V, order Opt. 028)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eVoltage Control\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eThumbwheel, five-decade voltage programmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Maximum input rating: 115 V AC ± 10%, 43-63 Hz, 0.5 A, 52 W. For 230 V AC ± 10% single-phase operation, Option 028 must be specified (reconnects power transformer taps).\u003cstrong\u003eImportant:\u003c\/strong\u003e PARD (rms\/p-p) footnote: 200 µV p-p noise is typical with a maximum 400 µV p-p spike of less than 1 µs duration occurring at twice power line frequency under worst case conditions of high line, full output voltage. When operated at 400 Hz input, peak-to-peak ripple is less than 10 mV.\u003cstrong\u003eImportant:\u003c\/strong\u003e Drift (Stability) footnote: Specified with final decade pot set to zero. If pot is set to value other than zero, pot wiper jump effect may cause drift of 0.0015% + 200 µV (90-day).\u003cstrong\u003eImportant:\u003c\/strong\u003e For 230 V ac single-phase input on models 6111A-6113A and 6116A, order Option 028.\u003cstrong\u003eImportant:\u003c\/strong\u003e Option 011 (internal overvoltage protection crowbar) is standard on models 6114A and 6115A; for models 6111A-6113A and 6116A it must be ordered separately to protect delicate loads against power supply failure or operator error.Recommended pairing: for rack installation alongside another half-rack-width unit, the 5060-8762 adapter frame supports mounting one or two half-rack-width supplies as listed in the datasheet's accessories section.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"HP","offers":[{"title":"None","offer_id":49231633121527,"sku":"agilen_6113a","price":495.0,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49231633154295,"sku":"nist_traceable","price":588.5,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49231633187063,"sku":"nist_traceable_data","price":605.5,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49231633219831,"sku":"17025","price":648.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6113a.jpg?v=1735286002"},{"product_id":"1630-b-k-precision-dc-power-supply-used","title":"1630 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0 to 30 VDC, coarse and fine adjustment\u003c\/li\u003e\n\u003cli\u003eOutput Current: HI Range: 0 to 3A; LO Range: 0 to 1.5A\u003c\/li\u003e\n\u003cli\u003ePower Requirements: 110\/120\/220\/240 VAC +\/- 10%, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Consumption: Approximately 170W or less at full load\u003c\/li\u003e\n\u003cli\u003eProtection: Reverse polarity protection, current limiting\u003c\/li\u003e\n\u003cli\u003eTemperature Range\u003c\/li\u003e\n\u003cli\u003eOperation: 0° to +40° C\u003c\/li\u003e\n\u003cli\u003eStorage: -15° to +70° C\u003c\/li\u003e\n\u003cli\u003eDimensions: 172 x 119 x 305 mm; 6-3\/4 x 4-11\/16 x 12\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Voltage Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Regulation Line (110-130V): ≤ 0.02% + 2 mV\u003c\/li\u003e\n\u003cli\u003eLoad (no load to full load): ≤ 0.02% + 3 mV\u003c\/li\u003e\n\u003cli\u003eRecovery Time: ≤200 µs typical\u003c\/li\u003e\n\u003cli\u003eRipple Voltage\u003c\/li\u003e\n\u003cli\u003ePeak-to-Peak: ≤ 2 mV\u003c\/li\u003e\n\u003cli\u003eRMS: ≤1 mV\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient 0° to +35° C: 5 mV\/° typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstant Current Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable Current Limits: 5% to 100% (0.15 A to 3 A)\u003c\/li\u003e\n\u003cli\u003eCurrent Regulation\u003c\/li\u003e\n\u003cli\u003eLine (110-130V): ≤ 5 mA typical; ≤9 mA maximum\u003c\/li\u003e\n\u003cli\u003eLoad: ≤5 mA typical; ≤ 9 mA maximum\u003c\/li\u003e\n\u003cli\u003eCurrent Ripple: ≤ 3mA typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eVoltmeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRange: 0 to 32V\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 2.5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eAmmeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI Range: 0 to 3.2A\u003c\/li\u003e\n\u003cli\u003eLO Range: 0 to 1.6A\u003c\/li\u003e\n\u003cli\u003eAccuracy: ± 2.5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe BK Precision 1630 DC Power Supply is a high quality, general purpose dc power source. The 1630 provides 0-30 volts dc output, adjustable with both coarse and fine controls for precise settability. The current output is 0-3 amps. Two current ranges, HI and LO, provide excellent current stability and meter resolution. Two large panel-mounted meters continuously monitor the output voltage and current.\u003c\/p\u003e\n\u003cp\u003eThe 1630 exhibits excellent regulation and low ripple characteristics. The circuit design incorporates a pre-regulator, which greatly reduces internal power dissipation at low output voltages. The styling is both attractive and functional. The mechanical configuration conserves bench space and allows for easy portability.\u003c\/p\u003e\n\u003cp\u003eThese instruments may be used in constant voltage or constant current applications. The crossover from constant voltage to constant current modes is smooth and automatic. LED's indicate the \"CV\" (constant voltage) or \"CC\" (constant current) mode of operation. In constant voltage applications, a current limit may be present. When load variations cause the current to reach the preset limit, the unit then regulates output current rather than output voltage. Current limits are adjustable from 5% to 100% of maximum. In constant current applications, the maximum voltage may be preset. When load variations cause current to drop below the regulated value, the unit reverts to regulated voltage operations at the preset value.\u003c\/p\u003e\n\u003cp\u003eReverse polarity protection prevents accidental damage of the power supply from improper connection to an external voltage, as well as the power supply.\u003cbr\u003eThe output is isolated from chassis and earth ground, which permits full flexibility of connections. When needed, the + or - polarity may be strapped to ground, or either polarity may be floated to an external voltage. Two supplies may be connected in series as a 0-to-60 volt power source, or two supplies may be connected in parallel, with suitable balancing resistors, for up to twice the output current.\u003c\/p\u003e\n\u003cp\u003eThe 1630 is well suited for a wide variety of electrical and electronics applications, including service shops, engineering labs, production testing, school laboratories, and home use by hobbyists.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231620145399,"sku":"bkprec_1630","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231620178167,"sku":"nist_traceable","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231620210935,"sku":"nist_traceable_data","price":0.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231620243703,"sku":"17025","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1630_1.jpg?v=1735286004"},{"product_id":"6038a-agilent-dc-power-supply-used","title":"Agilent 6038A 240 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eAgilent 6038A 240 W Single-Output Autoranging GPIB DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAutoranging output delivers maximum power across a wide range of voltage and current combinations\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSingle-output configurations covering 0–20 V to 0–500 V and currents up to 120 A across the series\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003ePower levels from 200 W (6033A, 6038A) to 1200 W (6010A, 6012B, 6030A, 6032A) across the family\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eGPIB-equipped models (6030A–6038A) support SCPI commands and VXIPlug\u0026amp;Play drivers for system integration\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUp to 16 GPIB units can be connected through one GPIB address via serial link\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eAnalog modulation input accepts 0 to 5 V or 0 to 4 kΩ for external programming of voltage and current\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eRemote sensing supports up to 2 V drop in each lead per datasheet specifications\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eEither output terminal can be grounded or floated from chassis ground within rated dc floating voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 Series Autoranging DC Power Supplies are single-output bench and system power supplies designed to deliver maximum power across a variety of operating points rather than at a single fixed voltage and current pair. The autoranging output characteristic allows one supply to cover a wide span of voltage and current combinations, which the datasheet describes as taking the place of multiple fixed-range power supplies on a test bench or in a test system. The non-GPIB 6010A, 6011A, 6012B, and 6015A models use ten-turn front panel pots for precise local control, while the GPIB-equipped 6030A through 6038A models add SCPI command compatibility and VXIPlug\u0026amp;Play drivers for integration into automated test systems.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAccording to the datasheet, these supplies are intended to save rack space by using fewer outputs, reduce cost by using fewer power supplies, and — for the non-GPIB models — provide control with external voltage through the analog modulation input. The GPIB models extend this to system-level applications where the datasheet notes that up to 16 power supplies can be connected through one GPIB address via the serial link, and that the supplies have excellent electrical efficiency making them a good choice for large systems. The non-GPIB units can also be connected in auto-parallel or auto-series with their corresponding GPIB unit (6030 Series) as part of a test system.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eBrand Heritage\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eHewlett-Packard's test \u0026amp; measurement business was spun out as Agilent Technologies in 1999. In 2014, Agilent further separated its electronic measurement business as Keysight Technologies. Instruments originally branded HP, then Agilent, and now sold or supported by Keysight share a continuous engineering lineage across all three brand names.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe Agilent 6000 and 6030 Series Autoranging DC Power Supplies are a related family of single-output supplies sharing the same autoranging output architecture. The non-GPIB 6010A, 6011A, 6012B, and 6015A models provide front-panel control with ten-turn pots and an analog modulation input. The GPIB-equipped 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A models add SCPI command compatibility, VXIPlug\u0026amp;Play drivers, and serial-link networking for automated test system integration.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eWithin the family, models are differentiated primarily by voltage range, current range, and maximum power. The 1000 W and 1200 W class supplies (6010A, 6011A, 6012B, 6015A, 6030A, 6031A, 6032A, 6035A) cover voltage ranges from 0–20 V up to 0–500 V depending on the model, while the 200 W class supplies (6033A and 6038A) provide lower-power capability in a half-rack form factor. The 6033A and 6038A also offer the Opt 800 rack-mount kit for two half-rack units side by side.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach model linked below has its own dedicated product page with pre-owned-matched pricing, current availability, and complete specifications. Click through to the specific model that matches your application's voltage, current, and power requirements.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe primary differentiator within the family is the GPIB and SCPI capability: the 6030 Series adds remote programming, readback, and the ability to network up to 16 supplies through one GPIB address. The non-GPIB 6000 Series models can be auto-paralleled or auto-seried with their corresponding GPIB units as part of a hybrid test system. The 6030 Series also carries a three-year warranty per the datasheet, compared to a one-year warranty on the non-GPIB models.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eVoltage and current ratings vary significantly across the family. Customers needing high voltage at lower currents should consider the 0–500 V models (6015A, 6035A). Customers needing high current at lower voltages should consider the 0–20 V, 0–120 A models (6011A, 6031A). Customers needing mid-range capability with high power should consider the 0–60 V models (6012B, 6032A, 6038A) or the 0–200 V models (6010A, 6030A).\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eMaximum Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e6038A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 10 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6010A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 200 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 17 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6011A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 20 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 120 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,064 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6012B\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 50 A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e6038A\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMaximum power\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V1, I1\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e60 V, 3.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V2, I2\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e40 V, 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAutoranging output V3, I3\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e20 V, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.035% + 40 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.09% + 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage rms (20 Hz to 20 MHz)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Voltage p-p\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e30 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple and noise, Current rms\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Voltage (at 25°C ±5°C)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.07% + 50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eReadback accuracy, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.2% + 11 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine regulation, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.01% + 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response time (10% step change)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eTransient response level\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e75 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e15 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eProgramming resolution, Current\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDC floating voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 100 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 120 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e6.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 220 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e3.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAC input current at 240 Vac\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e3.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e9.6 kg (21 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eShipping weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e11.4 kg (25 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Either output terminal can be grounded or floated from chassis ground within the rated dc floating voltage of ±240 V (6011A, 6012B, 6031A, 6032A, 6033A, 6038A) or ±550 V (6010A, 6015A, 6030A, 6035A).\u003cstrong\u003eImportant:\u003c\/strong\u003e A line cord option must be specified for the 6010A, 6011A, 6012B, 6015A (and for the 6030A-32A and 6035A). See pages 93-98 of the Agilent Power Products Catalog for ordering information.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 908 and Opt 909 rack-mount kits require support rails (e.g., E3663AC for Agilent rack cabinets).\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt 100 (87 to 106 Vac line input) derates the power supply output to 75%.\u003cstrong\u003eImportant:\u003c\/strong\u003e Opt J01 (stabilization for loads up to 10 Henries) is not available on the 6033A.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231626010871,"sku":"agilen_6038a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231626043639,"sku":"nist_traceable","price":210.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231626076407,"sku":"nist_traceable_data","price":280.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231626109175,"sku":"17025","price":350.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6038a.jpg?v=1735286006"},{"product_id":"1692-b-k-precision-dc-power-supply-new","title":"1692 B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLightweight and compact\u003c\/li\u003e\n\u003cli\u003eHigh efficiency\u003c\/li\u003e\n\u003cli\u003eCurrent fold back circuitry with illuminated indicator prevents overloading the power supply\u003c\/li\u003e\n\u003cli\u003eOver temperature protection circuitry\u003c\/li\u003e\n\u003cli\u003eOver voltage protection prevents abnormal high output voltage\u003c\/li\u003e\n\u003cli\u003eHigh RFI stability\u003c\/li\u003e\n\u003cli\u003eVariable output 3V to 15V at 40A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BK Precision 1692 Switching Mode DC Power Supply provides high current output in a lightweight and compact package. It is suitable for a variety of uses, especially for powering DC operated mobile radio equipment on the bench. It provides a variable voltage output from 3V to 15V at 40A continuous operation. In addition a fixed 13.8 VDC output is also selectable by a slider switch. Switching mode power supplies have the advantage of lightweight and high efficiency when compared to traditional linear mode power supplies. The efficiency can exceed 80% under the best conditions. Advanced circuitry protects against overload and provides immunity from RFI. A bright red and green LED display provides for an accurate and highly readable indicator of settings.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231623094519,"sku":"bkprec_1692_new","price":479.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1692-new.jpg?v=1735286008"},{"product_id":"6259b-agilent-dc-power-supply-used","title":"6259B Agilent DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 10 V\u003c\/li\u003e\n\u003cli\u003eCurrent: 50A\u003c\/li\u003e\n\u003cli\u003ePower: 850W\u003c\/li\u003e\n\u003cli\u003eRegulation: 0.01%\u003c\/li\u003e\n\u003cli\u003eMetered\u003c\/li\u003e\n\u003cli\u003eCV\/CC\u003c\/li\u003e\n\u003cli\u003eProgrammable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Agilent HP 6259B is completely transistorized and suitable for either bench or relay rack operation. The Agilent HP 6259B is a well-regulated, constant voltage\/constant current supply that will furnish full rated output voltage at the maximum rated output current or can be continuously adjusted throughout the output range.\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231630369015,"sku":"agilen_6259b","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231630434551,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231630467319,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231630532855,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6259b_1.jpg?v=1735286014"},{"product_id":"6260b-agilent-dc-power-supply-used","title":"6260B Agilent DC Power Supply Used","description":"\u003cp\u003e\u003cb\u003eAdditional Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 10V\u003c\/li\u003e\n\u003cli\u003eCurrent: 100A\u003c\/li\u003e\n\u003cli\u003ePower: 1000W\u003c\/li\u003e\n\u003cli\u003eOver-voltage protection\u003c\/li\u003e\n\u003cli\u003eAnalog programmable\u003c\/li\u003e\n\u003cli\u003eRemote sensing\u003c\/li\u003e\n\u003cli\u003eAuto-series, auto-parallel, and auto-tracking operation\u003c\/li\u003e\n\u003cli\u003e\u0026lt;50us load transient recovery\u003c\/li\u003e\n\u003cli\u003eRipple and noise (20 Hz to 20 MHz): CV: 500 uV RMS, 5 mV peak-to-peak; CC: 50 mA RMS\u003c\/li\u003e\n\u003cli\u003eLoad regulation: 0.01% + 200 uV, 0.02% + 2 mA\u003c\/li\u003e\n\u003cli\u003eLine regulation: 0.01% + 200 uV, 0.02% + 2 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Agilent HP 6260B employs a transistor series-regulator\/triac-preregulator circuit to achieve high efficiency, excellent regulation, low ripple and noise, and moderate programming speeds in a compact full-rack width package. Additional features include built-in overvoltage crowbar protection: remote error sensing: and auto-series, auto-parallel, and auto-tracking operation. The crowbar trip point adjustment and associated overvoltage indicator are conveniently located on the front panel.\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231644098807,"sku":"agilen_6260b","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231644131575,"sku":"nist_traceable","price":210.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231644164343,"sku":"nist_traceable_data","price":280.0,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231644229879,"sku":"17025","price":315.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6260b_1_1.jpg?v=1735286015"},{"product_id":"1785a-b-k-precision-dc-power-supply-used","title":"B+K Precision 1785A 18V\/5A Programmable DC Power Supply (Pre-Owned)","description":"\u003ch1 style=\"display:block; clear:both; text-align:left; font-size:28px; margin:0 0 16px 0;\"\u003eB+K Precision 1785A 18V\/5A Programmable DC Power Supply (Pre-Owned)\u003c\/h1\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eKey Features At A Glance\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eProgrammable DC output up to 18V\/5A (1785A), 30V\/3A (1786A), or 60V\/1.5A (1787A)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNine user-programmable preset outputs for fast recall of frequently used voltage and current settings\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eTen-step user-programmable output routine for automated test sequences in R\u0026amp;D or production\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eIn-case calibration via integral system software for uninterrupted operation\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eMetering accuracy of ±(0.5% + 1 digit) with 1mV ripple and noise (RMS)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eLine and load regulation of 0.02% + 5mV\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eOptional RS-232 interface with included serial cable and Windows\/DOS software\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eLED voltmeter and ammeter display with direct keypad entry\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe BK Precision 1785A is a programmable DC power supply offering 0–18V output with current capability of 0–5A. It is part of a three-model family — the 1785A, 1786A, and 1787A — that shares a common control architecture and feature set while offering different voltage and current envelopes to match the application. Direct keypad entry allows voltage and current values to be selected quickly and accurately, and the unit displays measured output on integrated LED voltmeter and ammeter readouts.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eBK Precision identifies these supplies for use in electronics work, manufacturing, design labs, electronic education, and battery charging. The combination of programmability, preset memory, and in-case calibration makes them suited to environments that need repeatable voltage and current settings across multiple test cycles, whether on a single bench or as part of an automated test routine.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eCompare Other Models in This Series\u003c\/h2\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe 1785A, 1786A, and 1787A make up a three-model family of programmable DC power supplies from BK Precision, sharing the same control interface, display, programming features, and chassis. The differentiation between them is the output envelope — each model targets a different voltage and current range while preserving the same programmability, preset memory, and 10-step routine capability across the line.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eAll three models carry the same metering accuracy of ±(0.5% + 1 digit), the same 1mV RMS ripple and noise specification, and the same 0.02% + 5mV line and load regulation. The choice between them comes down to whether the application calls for higher current at lower voltage, balanced voltage and current, or higher voltage at lower current.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eEach pre-owned model below is listed on its own dedicated product page with condition-matched pricing and availability. Click through to the specific model that fits your output requirement to see the full listing details and quote options for that exact unit.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe 1785A sits at the higher-current end of this family, with 0–18V output and 0–5A current capability. This makes it the natural fit when the device under test runs at lower voltage but draws more current — typical of logic-level circuits, low-voltage analog work, and battery charging applications within the supply's voltage range.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe 1785A delivers up to 5A at 18V — the highest current in the family — and is suited to lower-voltage, higher-current loads. The 1786A doubles the voltage range to 30V while dropping current capability to 3A, giving a balanced envelope for general bench work. The 1787A extends voltage further to 60V but reduces current to 1.5A, making it the choice when the application needs the higher voltage and current demands are modest.\u003c\/p\u003e\u003cp style=\"margin:0 0 12px 0;\"\u003eThe comparison table that follows lists the headline output specifications side by side. Programmability features, accuracy, ripple, regulation, and the physical chassis are identical across the three models — only the voltage and current envelope changes.\u003c\/p\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eOutput Current\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eInterface\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e\u003cstrong\u003e1785A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 18V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 5A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRS-232 (Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1786A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 30V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 3A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRS-232 (Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1787A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 60V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 1.5A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRS-232 (Option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1770\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-17.5V; 0-35V\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0-6A; 0-3A\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eGPIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp style=\"margin:0 0 8px 0; font-size:14px; color:#555;\"\u003eAdditional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.\u003c\/p\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAccessories Supplied\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eUser Manual\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eSerial Cable\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWindows Software\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eDOS Software\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eProduct Core \u0026amp; Specifications\u003c\/h2\u003e\u003ctable style=\"border-collapse:collapse; width:100%; clear:both; text-align:left; vertical-align:top; margin:0 0 16px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc; background:#f5f5f5;\"\u003e1785A\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput (DC)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 18V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOutput Current (Amp.)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0 - 5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eMetering Accuracy\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e±(0.5% + 1 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRipple \u0026amp; Noise (RMS)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLine Regulation\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.02% + 5mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLoad Regulation\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e0.02% + 5mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eRS-232\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e120V, 60Hz (or on request 220 - 240V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDimension (WxHxD)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003e8.07 x 4.53 x 10.63 in. (205 x 115 x 270 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eAccessory Supplied\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eUser Manuals, Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eApproximately 11 lbs. (5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px; text-align:left; vertical-align:top; border:1px solid #ccc;\"\u003eLED Voltmeter \u0026amp; Ampmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Standard line input is 120V, 60Hz. 220–240V operation is available on request — confirm input voltage configuration matches your facility before connecting.\u003cstrong\u003eImportant:\u003c\/strong\u003e For the 1785A\/1786A\/1787A series, the RS-232 interface is an option (not included with the base unit).\u003cstrong\u003eImportant:\u003c\/strong\u003e Operating voltage for the 1785A\/1786A\/1787A is 120V, 60Hz standard; 220 - 240V is available on request.\u003ch2 style=\"display:block; clear:both; text-align:left; font-size:22px; margin:24px 0 12px 0;\"\u003eAbout this used unit\u003c\/h2\u003e\u003cul style=\"list-style:disc; margin:0 0 16px 22px; padding:0; clear:both;\"\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eWarranty included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eFunctional verification included\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eStandard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px 0;\"\u003eNote that unnecessary accessories may not be included (contact Test Architect to confirm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align:center; margin:32px 0 8px 0;\"\u003e\u003cstrong\u003ePlease review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.\u003c\/strong\u003e\u003c\/p\u003e","brand":"B+K Precision","offers":[{"title":"None","offer_id":49231635742967,"sku":"bkprec_1785a","price":175.0,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49231635775735,"sku":"nist_traceable","price":268.5,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49231635808503,"sku":"nist_traceable_data","price":285.5,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49231635841271,"sku":"17025","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1785a_1.jpg?v=1735286021"},{"product_id":"1791-b-k-precision-dc-power-supply-used","title":"1791 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0-64 V\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-10 A\u003c\/li\u003e\n\u003cli\u003eConstant Voltage\/Constant Current Operation\u003c\/li\u003e\n\u003cli\u003eRemote Programming Facility\u003c\/li\u003e\n\u003cli\u003eFacility for Presetting the Output Voltage and Max. Load Current Limits\u003c\/li\u003e\n\u003cli\u003eSeparate DC Output ON\/OFF Switch\u003c\/li\u003e\n\u003cli\u003eRemote Sensing Facility\u003c\/li\u003e\n\u003cli\u003eHigh Stability and Close Regulation ± 0.01%\u003c\/li\u003e\n\u003cli\u003eMeets CE Specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BK Precision 1791 High Current Linear Power Supply, 0-64 VDC- 10A, LED is a cost effective, regulated DC power supply with 640 Watt output, suitable for bench operation or standard 19\" rack operation. The BK Precision 1791 is a high power workhorse that will easily deliver clean power to your high current circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for telecom application\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince noise elimination is critical for telecom application, the 1791 DC power supply offers low noise output, so that power supply noise does not interfere with testing of telecom devices. The 1791 is ideal for manufacturers who build equipment for telecom industry that operates from 48V or higher DC rail such as: base stations, switches, public and private telecom network equipment, PBX system and DC to DC power supplies that provide power to this equipment.\u003c\/p\u003e\n\u003cp\u003eThese well-regulated constant voltage\/constant current supplies deliver 0-64 V at 0-10 A. They can be adjusted continuously throughout the output range by front panel controls. The units will automatically cross over from constant voltage to constant current mode and vice-versa if the output exceeds preset limits. Front panel LED meters are provided for monitoring voltage and current. The load terminals and remote sense terminals are located on the front panel. Either the positive or negative output terminal may be grounded or floated up to a maximum of ±300VDC above ground.\u003c\/p\u003e\n\u003cp\u003eSpecial features include the ability to set constant current with no load and remote sense to compensate for any wire loss. The 1791 is designed to meet CE specifications and has superior performance to comparable models costing 20 to 30% more.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231623389431,"sku":"bkprec_1791","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231623422199,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231623454967,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231623487735,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1791.jpg?v=1735286023"},{"product_id":"6038l-agilent-dc-power-supply-used","title":"6038L Agilent DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 60V \u003c\/li\u003e\n\u003cli\u003eCurrent: 10A\u003c\/li\u003e\n\u003cli\u003ePower: 200W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Agilent HP 6038L is an autoranging power supply for use in the 306X board test systems only.  The front panel only has a line switch, line indicator, and OVP adjust.\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231624470775,"sku":"agilen_6038l","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231624503543,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231624536311,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231624569079,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6038l.jpg?v=1735286026"},{"product_id":"1735a-b-k-precision-dc-power-supply-new","title":"1735A B\u0026K Precision DC Power Supply New","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0-30 V\u003c\/li\u003e\n\u003cli\u003eOutput Current: 0-3 A\u003c\/li\u003e\n\u003cli\u003eContinuously monitor voltage and current output on two analog meters\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in parallel to double the current output\u003c\/li\u003e\n\u003cli\u003eConnect two supplies in series to double the voltage output\u003c\/li\u003e\n\u003cli\u003eReliable, Durable\u003c\/li\u003e\n\u003cli\u003eOperate continuously at full load without overheating\u003c\/li\u003e\n\u003cli\u003eFully overload protected\u003c\/li\u003e\n\u003cli\u003eCoarse and fine voltage controls\u003c\/li\u003e\n\u003cli\u003eExcellent regulation\u003c\/li\u003e\n\u003cli\u003eVery low ripple\u003c\/li\u003e\n\u003cli\u003eConstant voltage or constant current operation\u003c\/li\u003e\n\u003cli\u003ecUL certified\u003c\/li\u003e\n\u003cli\u003eIncluded Accessories: Instruction manual \u0026amp; power cord\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTwo-Year Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Regulation: Line (120 VAC ±10%) \u0026lt;0.01% + 3 mV; Load (no load - full load) \u0026lt;0.01% + 3 mV\u003c\/li\u003e\n\u003cli\u003eRecovery Time:  \u0026lt;100 μs\u003c\/li\u003e\n\u003cli\u003eRipple \u0026amp; Noise:  \u0026lt;1 mV rms\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: \u0026lt;300 ppm\/°C\u003c\/li\u003e\n\u003cli\u003eAdjustable Current Range: 5% to 100%\u003c\/li\u003e\n\u003cli\u003eCurrent Regulation: Line (120 VAC ±10%) \u0026lt;0.2% + 3 mA; Load \u0026lt;0.2% + 3 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Ripple: \u0026lt;3 mArms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMetering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: 4-digit LED\u003c\/li\u003e\n\u003cli\u003eVoltmeter Range: 0-99.99 V (green)\u003c\/li\u003e\n\u003cli\u003eVoltmeter Accuracy: ± (0.5% rdg +9 digits)\u003c\/li\u003e\n\u003cli\u003eAmmeter Range: High: 0-9.999 A (red)\u003c\/li\u003e\n\u003cli\u003eAmmeter Accuracy: ± (0.5% rdg +9 digits)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload Protection: Current limiting, reverse polarity, overvoltage, short circuit\u003c\/li\u003e\n\u003cli\u003ePower Requirements: 120 VAC ±10%, 60 Hz only (120\/220\/230\/240 VAC ±10%, 50\/60 Hz version available)\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 180 W\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 32 to 104 °F (0 to 40 °C), \u0026lt;75% R.H.\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: 5 to 158 °F (-15 to +70 °C), \u0026lt;85% R.H.\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 6.2” x 5.5” x 12.5” (158 x 140 x 318 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe BK Precision 1735A 4 Digit Display DC Power Supply (0-30V, 0-3A) continuously monitors voltage and current output on two 4 digit LED display. The BK Precision 1735A operates continuously at full load without overheating. Connect two supplies in parallel to double the current output or connect two supplies in series to double the voltage output.\u003c\/p\u003e","brand":"B\u0026K Precision","offers":[{"title":"Default Title","offer_id":49231621390583,"sku":"bkprec_1735a_new","price":562.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1735a-new_2.jpg?v=1735286028"},{"product_id":"1686-b-k-precision-dc-power-supply-used","title":"1686 B\u0026K Precision DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 3 to 14 VDC\u003c\/li\u003e\n\u003cli\u003eOutput Current: Proportional to Output Voltage\u003c\/li\u003e\n\u003cli\u003eDCV Output - Max DCA: 3V - 2.5A, 5V - 4.5A, 9V - 7.5A, 12V - 10A, 13.8V - 12A, 14V - 12A\u003c\/li\u003e\n\u003cli\u003e12 A guaranteed @ 13.8V\u003c\/li\u003e\n\u003cli\u003eCurrent limiting overload protection\u003c\/li\u003e\n\u003cli\u003eOver voltage protection\u003c\/li\u003e\n\u003cli\u003eShort circuit protection\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection\u003c\/li\u003e\n\u003cli\u003eThermostatically controlled cooling fan\u003c\/li\u003e\n\u003cli\u003eThermal protection\u003c\/li\u003e\n\u003cli\u003eOperates continuously at full load without overheating\u003c\/li\u003e\n\u003cli\u003eConnect two in parallel for more current\u003c\/li\u003e\n\u003cli\u003eConnect two in series for higher voltage\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026K Precision","offers":[{"title":"None","offer_id":49231623586039,"sku":"bkprec_1686","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231623618807,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231623651575,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231623717111,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/bkprec_1686.jpg?v=1735286031"},{"product_id":"6263a-agilent-dc-power-supply-used","title":"6263A Agilent DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 18V\u003c\/li\u003e\n\u003cli\u003eCurrent: 10A\u003c\/li\u003e\n\u003cli\u003ePower: 200W\u003c\/li\u003e\n\u003cli\u003eRegulation: 0.02%\u003c\/li\u003e\n\u003cli\u003eMetered\u003c\/li\u003e\n\u003cli\u003eCV\/CC\u003c\/li\u003e\n\u003cli\u003eProgrammable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Agilent HP 6263A is a low voltage rack mounting supply. The instrument is a Harrison LVR Series supply that is a versatile, compact, high-performance supply designed for both lab and system use. The 6263A features Auto-Series, Auto-Parallel and Auto-Tracking operation.\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231632662775,"sku":"agilen_6263a","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231632728311,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231632761079,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231632826615,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6263a.jpg?v=1735286033"},{"product_id":"6202b-agilent-dc-power-supply-used","title":"6202B Agilent DC Power Supply Used","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage: 40V\u003c\/li\u003e\n\u003cli\u003eCurrent: 0.75A\u003c\/li\u003e\n\u003cli\u003ePower: 30W\u003c\/li\u003e\n\u003cli\u003eRegulation is 0.01%\u003c\/li\u003e\n\u003cli\u003e1\/2 Rack Width Unit\u003c\/li\u003e\n\u003cli\u003eConstant Current\/Constant Voltage Features\u003c\/li\u003e\n\u003cli\u003eFully Metered\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Agilent 6202B is a low cost, compact and reliable power supply and is designed especially for bench use. Their performance and features make them ideal for circuit development, component evaluation, and other general laboratory applications. The 6202B is packaged in 8-inch wide case which are suitable for bench use or rack installation. Standard features include Constant Voltage\/Constant Current or Constant Voltage\/Constant Limit operation, remote resistance and voltage programming, remote sensing, Auto-Series\/Auto-Parallel\/Auto-Tracking operation, and dual-function multi-range metering.\u003c\/p\u003e","brand":"Agilent","offers":[{"title":"None","offer_id":49231626305783,"sku":"agilen_6202b","price":0.0,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable","offer_id":49231626338551,"sku":"nist_traceable","price":93.5,"currency_code":"USD","in_stock":false},{"title":"NIST Traceable with Full Data","offer_id":49231626371319,"sku":"nist_traceable_data","price":110.5,"currency_code":"USD","in_stock":false},{"title":"ISO IEC 17025 Accredited","offer_id":49231626404087,"sku":"17025","price":153.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/agilen_6202b.jpg?v=1735286035"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/collections\/Power-Supplies-Loads-DC-Power-Supply_f180b924-86e1-428f-80cf-9834917c81b4.png?v=1735284273","url":"https:\/\/valuetronics.com\/collections\/power-supplies-loads-dc-power-supply.oembed?page=76","provider":"ValueTronics","version":"1.0","type":"link"}