{"title":"Fluke DMM Series and Clamp Meters","description":null,"products":[{"product_id":"fluke-325-fluke-clamp-meter-new","title":"FLUKE-325 Clamp Meter New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 A AC and DC current measurement\u003c\/li\u003e\n\u003cli\u003e600 V AC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement up to 40 k ohm with continuity detection\u003c\/li\u003e\n\u003cli\u003eTemperature and capacitance measurement\u003c\/li\u003e\n\u003cli\u003eFrequency measurement\u003c\/li\u003e\n\u003cli\u003eSlim, ergonomic design\u003c\/li\u003e\n\u003cli\u003eLarge, easy to read backlight display\u003c\/li\u003e\n\u003cli\u003eCAT IV 300V\/CAT III 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eHold button\u003c\/li\u003e\n\u003cli\u003eTwo-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 325 Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eSoft case\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTrue-RMS measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tools for commercial and residential electricians. The Fluke 325 is designed to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable compartments. The Fluke 325 also offers DC current and frequency measurements.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"None","offer_id":49232085188855,"sku":"fluke_325_new","price":359.15,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49232085221623,"sku":"nist_traceable","price":412.45,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49232085254391,"sku":"nist_traceable_data","price":424.75,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49232085287159,"sku":"17025","price":433.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_325-new.jpg?v=1735291292"},{"product_id":"fluke-323-fluke-clamp-meter-new","title":"FLUKE-323 Clamp Meter New","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 A AC current measurement\u003c\/li\u003e\n\u003cli\u003e600 V AC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement up to 40 k ohm with continuity detection\u003c\/li\u003e\n\u003cli\u003eSlim, ergonomic design\u003c\/li\u003e\n\u003cli\u003eCAT IV 300V\/CAT III 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eHold button\u003c\/li\u003e\n\u003cli\u003eTwo-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e323 Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eSoft case\u003c\/li\u003e\n\u003cli\u003eUser's manual \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTrue-RMS measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tools for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49232089809143,"sku":"fluke_323_new","price":199.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_323-new_1.jpg?v=1735291330"},{"product_id":"fluke-117-fluke-multimeter-new","title":"FLUKE-117 Fluke Multimeter New","description":"\u003cdiv style=\"overflow-y: hidden; overflow-x: auto;\"\u003e\n\u003cstyle type=\"text\/css\" xml=\"space\"\u003e\u003c!--\n\t#page1-div p {margin: 0; padding: 0;}\n\t#page1-div .ft10{font-size:22px;font-family:Times;color:#231f20;}\n\t#page1-div .ft11{font-size:52px;font-family:Times;color:#231f20;}\n\t#page1-div .ft12{font-size:34px;font-family:Times;color:#231f20;}\n\t#page1-div .ft13{font-size:19px;font-family:Times;color:#231f20;}\n\t#page1-div .ft14{font-size:13px;font-family:Times;color:#231f20;}\n\t#page1-div .ft15{font-size:19px;font-family:Times;color:#231f20;}\n\t#page1-div .ft16{font-size:14px;font-family:Times;color:#231f20;}\n\t#page1-div .ft17{font-size:11px;font-family:Times;color:#231f20;}\n\t#page1-div .ft18{font-size:7px;font-family:Times;color:#231f20;}\n\t#page1-div .ft19{font-size:8px;font-family:Times;color:#231f20;}\n\t#page1-div .ft110{font-size:15px;font-family:Times;color:#231f20;}\n\t#page1-div .ft111{font-size:12px;font-family:Times;color:#231f20;}\n\t#page1-div .ft112{font-size:15px;font-family:Times;color:#231f20;}\n\t#page1-div .ft113{font-size:10px;font-family:Times;color:#231f20;}\n\t#page1-div .ft114{font-size:7px;font-family:Times;color:#231f20;}\n\t#page1-div .ft115{font-size:0px;font-family:Times;color:#231f20;}\n\t#page1-div .ft116{font-size:25px;font-family:Times;color:#3f4c6b;}\n\t#page1-div .ft117{font-size:15px;line-height:17px;font-family:Times;color:#231f20;}\n\t#page1-div .ft118{font-size:14px;line-height:18px;font-family:Times;color:#231f20;}\n\t#page1-div .ft119{font-size:11px;line-height:14px;font-family:Times;color:#231f20;}\n\t#page1-div .ft120{font-size:11px;line-height:15px;font-family:Times;color:#231f20;}\n\t#page1-div .ft121{font-size:9px;line-height:12px;font-family:Times;color:#231f20;}\n--\u003e\u003c\/style\u003e\n\u003cdiv id=\"page1-div\" style=\"position: relative; height: 1188px;\"\u003e\n\u003cimg style=\"max-width: 891px; position: absolute;\" src=\"\/pub\/media\/vti\/dsimages\/fluke_117_001.png\" alt=\"background image\" height=\"1188\"\u003e\n\u003cp class=\"ft10\" style=\"position: absolute; top: 248px; left: 624px; white-space: nowrap;\"\u003e\u003cb\u003eTechnical Data\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft11\" style=\"position: absolute; top: 138px; left: 66px; white-space: nowrap;\"\u003e\u003cb\u003eFluke 117\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft12\" style=\"position: absolute; top: 187px; left: 66px; white-space: nowrap;\"\u003e\u003cb\u003eElectrician’s Multimeter\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft13\" style=\"position: absolute; top: 222px; left: 66px; white-space: nowrap;\"\u003e\u003cb\u003ewith Non-Contact Voltage\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft14\" style=\"position: absolute; top: 574px; left: 459px; white-space: nowrap;\"\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 593px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 596px; left: 466px; white-space: nowrap;\"\u003e \u003cb\u003eVoltAlert\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft18\" style=\"position: absolute; top: 599px; left: 529px; white-space: nowrap;\"\u003e™\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 596px; left: 536px; white-space: nowrap;\"\u003e\u003cb\u003etechnology\u003c\/b\u003e for non-contact voltage detection\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 612px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 616px; left: 466px; white-space: nowrap;\"\u003e \u003cb\u003eAutoVolt\u003c\/b\u003e automatic ac\/dc voltage selection\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 632px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 635px; left: 466px; white-space: nowrap;\"\u003e LoZ: helps prevent false readings due to ghost voltage\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 651px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 655px; left: 466px; white-space: nowrap;\"\u003e Large white LED backlight to work in poorly lit areas\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 671px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 674px; left: 466px; white-space: nowrap;\"\u003e True-rms for accurate measurements on non-linear loads\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 690px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 694px; left: 466px; white-space: nowrap;\"\u003e Measures 10 A (20 A overload for 30 seconds)\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 710px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 713px; left: 466px; white-space: nowrap;\"\u003e Resistance, continuity, frequency and capacitance\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 729px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 733px; left: 466px; white-space: nowrap;\"\u003e Min\/Max\/Average to record signal fluctuations\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 749px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 752px; left: 466px; white-space: nowrap;\"\u003e Compatible with optional magnetic hanger (ToolPak\u003c\/p\u003e\n\u003cp class=\"ft19\" style=\"position: absolute; top: 755px; left: 783px; white-space: nowrap;\"\u003e™\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 752px; left: 791px; white-space: nowrap;\"\u003e) for\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 767px; left: 472px; white-space: nowrap;\"\u003ehands free operation\u003c\/p\u003e\n\u003cp class=\"ft15\" style=\"position: absolute; top: 783px; left: 459px; white-space: nowrap;\"\u003e•\u003c\/p\u003e\n\u003cp class=\"ft16\" style=\"position: absolute; top: 787px; left: 466px; white-space: nowrap;\"\u003e CAT III 600 V safety rated\u003c\/p\u003e\n\u003cp class=\"ft117\" style=\"position: absolute; top: 349px; left: 459px; white-space: nowrap;\"\u003e\u003cb\u003eCompact true-rms meter for \u003cbr\u003ecommercial applications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft118\" style=\"position: absolute; top: 394px; left: 459px; white-space: nowrap;\"\u003eThe Fluke 117 is the ideal meter for \u003cbr\u003edemanding settings like commercial \u003cbr\u003ebuildings, hospitals and schools. The 117 \u003cbr\u003eincludes integrated non-contact voltage \u003cbr\u003edetection to help get the job done faster. \u003c\/p\u003e\n\u003cp class=\"ft112\" style=\"position: absolute; top: 851px; left: 459px; white-space: nowrap;\"\u003e\u003cb\u003eGeneral specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft120\" style=\"position: absolute; top: 875px; left: 459px; white-space: nowrap;\"\u003eAccuracy is specified for 1 year after calibration, at operating \u003cbr\u003etemperatures of 18 °C to 28 °C, with relative humidity at \u003cbr\u003e0 % to 90 %.\u003cbr\u003eThe accuracy specifications take the form of: \u003cbr\u003e± ( [ % of reading ] + [ counts ] )\u003c\/p\u003e\n\u003cp class=\"ft121\" style=\"position: absolute; top: 963px; left: 465px; white-space: nowrap;\"\u003eMaximum voltage between any \u003cbr\u003eterminal and earth ground\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 962px; left: 653px; white-space: nowrap;\"\u003e600 V\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 990px; left: 465px; white-space: nowrap;\"\u003eSurge protection\u003c\/p\u003e\n\u003cp class=\"ft121\" style=\"position: absolute; top: 989px; left: 653px; white-space: nowrap;\"\u003e6 kV peak per IEC 61010-1 600 V \u003cbr\u003eCAT III, Pollution Degree 2\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1018px; left: 465px; white-space: nowrap;\"\u003eFuse for A input\u003c\/p\u003e\n\u003cp class=\"ft121\" style=\"position: absolute; top: 1017px; left: 653px; white-space: nowrap;\"\u003e11 A, 1000 V FAST Fuse \u003cbr\u003e(Fluke PN 803293)\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1046px; left: 465px; white-space: nowrap;\"\u003eDisplay\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1045px; left: 653px; white-space: nowrap;\"\u003eDigital: 6,000 counts, updates 4\/sec\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1060px; left: 465px; white-space: nowrap;\"\u003eBar graph\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1060px; left: 653px; white-space: nowrap;\"\u003e33 segments, updates 32\/sec\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1075px; left: 465px; white-space: nowrap;\"\u003eOperating temperature\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1074px; left: 653px; white-space: nowrap;\"\u003e-10 °C to + 50 °C\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1090px; left: 465px; white-space: nowrap;\"\u003eStorage temperature\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1089px; left: 653px; white-space: nowrap;\"\u003e-40 °C to + 60 °C\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1105px; left: 465px; white-space: nowrap;\"\u003eBattery\u003c\/p\u003e\n\u003cp class=\"ft121\" style=\"position: absolute; top: 1104px; left: 653px; white-space: nowrap;\"\u003e9 volt Alkaline, NEDA 1604A\/ \u003cbr\u003eIEC 6LR61\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1133px; left: 465px; white-space: nowrap;\"\u003eBattery life\u003c\/p\u003e\n\u003cp class=\"ft113\" style=\"position: absolute; top: 1132px; left: 653px; white-space: nowrap;\"\u003e400 hours typical, without backlight\u003c\/p\u003e\n\u003cp class=\"ft114\" style=\"position: absolute; top: 1129px; left: 279px; white-space: nowrap;\"\u003e\u003cb\u003eN10140\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft115\" style=\"position: absolute; top: 1127px; left: 130px; white-space: nowrap;\"\u003e\u003cb\u003eR\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft14\" style=\"position: absolute; top: 994px; left: 66px; white-space: nowrap;\"\u003e\u003cb\u003eActual size\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle type=\"text\/css\" xml=\"space\"\u003e\u003c!--\n\t#page2-div p {margin: 0; padding: 0;}\n\t#page2-div .ft20{font-size:21px;font-family:Times;color:#ffffff;}\n\t#page2-div .ft21{font-size:11px;font-family:Times;color:#231f20;}\n\t#page2-div .ft22{font-size:7px;font-family:Times;color:#231f20;}\n\t#page2-div .ft23{font-size:12px;font-family:Times;color:#231f20;}\n\t#page2-div .ft24{font-size:12px;font-family:Times;color:#231f20;}\n\t#page2-div .ft25{font-size:12px;font-family:Times;color:#231f20;}\n\t#page2-div .ft26{font-size:12px;font-family:Times;color:#231f20;font-weight:bold}\n\t#page2-div .ft27{font-size:11px;font-family:Times;color:#231f20;font-weight:bold;}\n\t#page2-div .ft28{font-size:5px;font-family:Times;color:#231f20;}\n\t#page2-div .ft29{font-size:8px;font-family:Times;color:#231f20;}\n\t#page2-div .ft210{font-size:15px;font-family:Times;color:#ffffff;}\n\t#page2-div .ft211{font-size:13px;font-family:Times;color:#231f20;}\n\t#page2-div .ft212{font-size:11px;font-family:Times;color:#231f20;}\n\t#page2-div .ft213{font-size:11px;font-family:Times;color:#231f20;}\n\t#page2-div .ft214{font-size:25px;font-family:Times;color:#3f4c6b;}\n\t#page2-div .ft215{font-size:8px;line-height:11px;font-family:Times;color:#231f20;}\n\t#page2-div .ft216{font-size:7px;line-height:9px;font-family:Times;color:#231f20;}\n\t#page2-div .ft217{font-size:11px;line-height:12px;font-family:Times;color:#231f20;font-weight:bold;}\n\t#page2-div .ft218{font-size:11px;line-height:12px;font-family:Times;color:#231f20;}\n\t#page2-div .ft219{font-size:15px;line-height:17px;font-family:Times;color:#ffffff;}\n\t#page2-div .ft220{font-size:13px;line-height:16px;font-family:Times;color:#231f20;}\n\t#page2-div .ft221{font-size:11px;line-height:13px;font-family:Times;color:#231f20;}\n\t#page2-div .ft222{font-size:11px;line-height:15px;font-family:Times;color:#231f20;}\n--\u003e\u003c\/style\u003e\n\u003cdiv id=\"page2-div\" style=\"position: relative; height: 1188px;\"\u003e\n\u003cimg style=\"max-width: 891px; position: absolute;\" src=\"\/pub\/media\/vti\/dsimages\/fluke_117_002.png\" alt=\"background image\" height=\"1188\"\u003e\n\u003cp class=\"ft20\" style=\"position: absolute; top: 143px; left: 68px; white-space: nowrap;\"\u003e\u003cb\u003eAccuracy Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft27\" style=\"position: absolute; top: 209px; left: 72px; white-space: nowrap;\"\u003e\u003cb\u003eMeasurement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft27\" style=\"position: absolute; top: 209px; left: 180px; white-space: nowrap;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft27\" style=\"position: absolute; top: 209px; left: 288px; white-space: nowrap;\"\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft27\" style=\"position: absolute; top: 209px; left: 397px; white-space: nowrap;\"\u003e\u003cb\u003eAccuracy \u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 208px; left: 449px; white-space: nowrap;\"\u003e± ([% of reading] + [counts])\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 230px; left: 72px; white-space: nowrap;\"\u003eDC millivolts\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 229px; left: 180px; white-space: nowrap;\"\u003e600.0 mV\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 229px; left: 288px; white-space: nowrap;\"\u003e0.1 mV\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 229px; left: 397px; white-space: nowrap;\"\u003e0.5 % + 2\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 250px; left: 72px; white-space: nowrap;\"\u003eDC volts\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 249px; left: 180px; white-space: nowrap;\"\u003e6.000 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 249px; left: 288px; white-space: nowrap;\"\u003e0.001 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 269px; left: 397px; white-space: nowrap;\"\u003e0.5 % + 2\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 269px; left: 180px; white-space: nowrap;\"\u003e60.00 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 269px; left: 288px; white-space: nowrap;\"\u003e0.01 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 290px; left: 180px; white-space: nowrap;\"\u003e600.0 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 290px; left: 288px; white-space: nowrap;\"\u003e0.1 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 311px; left: 72px; white-space: nowrap;\"\u003eAuto volts\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 310px; left: 180px; white-space: nowrap;\"\u003e600.0 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 310px; left: 288px; white-space: nowrap;\"\u003e0.1 V\u003c\/p\u003e\n\u003cp class=\"ft217\" style=\"position: absolute; top: 310px; left: 397px; white-space: nowrap;\"\u003e2.0 % + 3 (dc, 45 Hz to 500 Hz) \u003cbr\u003e4.0 % + 3 (500 Hz to 1 kHz)\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 344px; left: 72px; white-space: nowrap;\"\u003eAC millivolts\u003c\/p\u003e\n\u003cp class=\"ft28\" style=\"position: absolute; top: 344px; left: 138px; white-space: nowrap;\"\u003e1\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 344px; left: 143px; white-space: nowrap;\"\u003e \u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 357px; left: 72px; white-space: nowrap;\"\u003etrue-rms\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 344px; left: 180px; white-space: nowrap;\"\u003e600.0 mV\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 344px; left: 288px; white-space: nowrap;\"\u003e0.1 mV\u003c\/p\u003e\n\u003cp class=\"ft217\" style=\"position: absolute; top: 344px; left: 397px; white-space: nowrap;\"\u003e1.0 % + 3 (dc, 45 Hz to 500 Hz) \u003cbr\u003e2.0 % + 3 (500 Hz to 1 kHz)\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 378px; left: 72px; white-space: nowrap;\"\u003eAC volts\u003c\/p\u003e\n\u003cp class=\"ft28\" style=\"position: absolute; top: 377px; left: 115px; white-space: nowrap;\"\u003e1\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 378px; left: 119px; white-space: nowrap;\"\u003e true-rms\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 377px; left: 180px; white-space: nowrap;\"\u003e6.000 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 377px; left: 288px; white-space: nowrap;\"\u003e0.001 V\u003c\/p\u003e\n\u003cp class=\"ft217\" style=\"position: absolute; top: 391px; left: 397px; white-space: nowrap;\"\u003e1.0 % + 3 (45 Hz to 500 Hz) \u003cbr\u003e2.0 % + 3 (500 Hz to 1 kHz)\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 397px; left: 180px; white-space: nowrap;\"\u003e60.00 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 397px; left: 288px; white-space: nowrap;\"\u003e0.01 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 418px; left: 180px; white-space: nowrap;\"\u003e600.0 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 418px; left: 288px; white-space: nowrap;\"\u003e0.1 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 439px; left: 72px; white-space: nowrap;\"\u003eContinuity\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 438px; left: 180px; white-space: nowrap;\"\u003e600 Ω\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 438px; left: 288px; white-space: nowrap;\"\u003e1 Ω\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 438px; left: 397px; white-space: nowrap;\"\u003eBeeper on \u0026lt; 20 Ω off \u0026gt; 250 Ω; detects\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 451px; left: 397px; white-space: nowrap;\"\u003eopens or shorts of 500 µs or longer.\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 472px; left: 72px; white-space: nowrap;\"\u003eOhms\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 471px; left: 180px; white-space: nowrap;\"\u003e600.0 Ω\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 471px; left: 288px; white-space: nowrap;\"\u003e0.1Ω\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 471px; left: 397px; white-space: nowrap;\"\u003e0.9 % + 2\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 492px; left: 180px; white-space: nowrap;\"\u003e6.000 kΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 492px; left: 288px; white-space: nowrap;\"\u003e0.001 kΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 522px; left: 397px; white-space: nowrap;\"\u003e0.9 % + 1\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 512px; left: 180px; white-space: nowrap;\"\u003e60.00 kΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 512px; left: 288px; white-space: nowrap;\"\u003e0.01 kΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 533px; left: 180px; white-space: nowrap;\"\u003e600.0 kΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 533px; left: 288px; white-space: nowrap;\"\u003e0.1 kΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 553px; left: 180px; white-space: nowrap;\"\u003e6.000 MΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 553px; left: 288px; white-space: nowrap;\"\u003e0.001 MΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 573px; left: 180px; white-space: nowrap;\"\u003e40.00 MΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 573px; left: 288px; white-space: nowrap;\"\u003e0.01 MΩ\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 573px; left: 397px; white-space: nowrap;\"\u003e1.5 % + 2\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 595px; left: 72px; white-space: nowrap;\"\u003eDiode test\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 594px; left: 180px; white-space: nowrap;\"\u003e2.000 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 594px; left: 288px; white-space: nowrap;\"\u003e0.001 V\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 594px; left: 397px; white-space: nowrap;\"\u003e0.9 % + 2\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 615px; left: 72px; white-space: nowrap;\"\u003eCapacitance\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 614px; left: 180px; white-space: nowrap;\"\u003e1000 nF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 614px; left: 288px; white-space: nowrap;\"\u003e1 nF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 635px; left: 397px; white-space: nowrap;\"\u003e1.9 % + 2\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 635px; left: 180px; white-space: nowrap;\"\u003e10.00 µF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 635px; left: 288px; white-space: nowrap;\"\u003e0.01 µF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 655px; left: 180px; white-space: nowrap;\"\u003e100.0 µF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 655px; left: 288px; white-space: nowrap;\"\u003e0.1 µF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 676px; left: 180px; white-space: nowrap;\"\u003e9999 µF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 676px; left: 288px; white-space: nowrap;\"\u003e1 µF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 696px; left: 180px; white-space: nowrap;\"\u003e100 µF to 1000 µF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 696px; left: 397px; white-space: nowrap;\"\u003e1.9 % + 2\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 716px; left: 180px; white-space: nowrap;\"\u003e\u0026gt; 1000 µF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 716px; left: 397px; white-space: nowrap;\"\u003e5 % + 20\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 738px; left: 72px; white-space: nowrap;\"\u003eLo-Z capacitance\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 737px; left: 180px; white-space: nowrap;\"\u003e1 nF to 500 µF\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 737px; left: 397px; white-space: nowrap;\"\u003e10 % + 2 typical\u003c\/p\u003e\n\u003cp class=\"ft217\" style=\"position: absolute; top: 758px; left: 72px; white-space: nowrap;\"\u003eAC amps true-rms \u003cbr\u003e(45 Hz to 500 Hz)\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 757px; left: 180px; white-space: nowrap;\"\u003e6.000 A\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 757px; left: 288px; white-space: nowrap;\"\u003e0.001 A\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 768px; left: 397px; white-space: nowrap;\"\u003e1.5 % + 3\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 778px; left: 180px; white-space: nowrap;\"\u003e10.00 A\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 778px; left: 288px; white-space: nowrap;\"\u003e0.01 A\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 798px; left: 180px; white-space: nowrap;\"\u003e20 A overload for 30 seconds max.\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 820px; left: 72px; white-space: nowrap;\"\u003eDC amps\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 819px; left: 180px; white-space: nowrap;\"\u003e6.000 A\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 819px; left: 288px; white-space: nowrap;\"\u003e0.001 A\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 829px; left: 397px; white-space: nowrap;\"\u003e1.0 % + 3\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 839px; left: 180px; white-space: nowrap;\"\u003e10.00 A\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 839px; left: 288px; white-space: nowrap;\"\u003e0.01 A\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 860px; left: 180px; white-space: nowrap;\"\u003e20 A overload for 30 seconds max.\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 881px; left: 72px; white-space: nowrap;\"\u003eHz (V or A input)\u003c\/p\u003e\n\u003cp class=\"ft28\" style=\"position: absolute; top: 881px; left: 160px; white-space: nowrap;\"\u003e2\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 880px; left: 180px; white-space: nowrap;\"\u003e99.99 Hz\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 880px; left: 288px; white-space: nowrap;\"\u003e0.01 Hz\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 911px; left: 397px; white-space: nowrap;\"\u003e0.1 % + 2\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 900px; left: 180px; white-space: nowrap;\"\u003e999.9 Hz\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 900px; left: 288px; white-space: nowrap;\"\u003e0.1 Hz\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 921px; left: 180px; white-space: nowrap;\"\u003e9.999 kHz\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 921px; left: 288px; white-space: nowrap;\"\u003e0.001 kHz\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 941px; left: 180px; white-space: nowrap;\"\u003e50.00 kHz\u003c\/p\u003e\n\u003cp class=\"ft26\" style=\"position: absolute; top: 941px; left: 288px; white-space: nowrap;\"\u003e0.01 kHz\u003c\/p\u003e\n\u003cp class=\"ft29\" style=\"position: absolute; top: 962px; left: 66px; white-space: nowrap;\"\u003e\u003cb\u003eNotes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft28\" style=\"position: absolute; top: 972px; left: 66px; white-space: nowrap;\"\u003e1\u003c\/p\u003e\n\u003cp class=\"ft218\" style=\"position: absolute; top: 973px; left: 72px; white-space: nowrap;\"\u003eAll ac voltage ranges except Auto-V\/LoZ are specified from 1 % to 100 % of range. Auto-V\/LoZ is specified from 0.0 V. \u003cbr\u003eBecause inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-\u003cbr\u003ezero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3\u003c\/p\u003e\n\u003cp class=\"ft21\" style=\"position: absolute; top: 1009px; left: 72px; white-space: nowrap;\"\u003eat 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.\u003c\/p\u003e\n\u003cp class=\"ft28\" style=\"position: absolute; top: 1020px; left: 66px; white-space: nowrap;\"\u003e2\u003c\/p\u003e\n\u003cp class=\"ft21\" style=\"position: absolute; top: 1021px; left: 72px; white-space: nowrap;\"\u003eFrequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.\u003c\/p\u003e\n\u003cp class=\"ft219\" style=\"position: absolute; top: 212px; left: 644px; white-space: nowrap;\"\u003e\u003cb\u003eOrdering  \u003cbr\u003eInformation\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"ft211\" style=\"position: absolute; top: 267px; left: 644px; white-space: nowrap;\"\u003eFluke-117\u003c\/p\u003e\n\u003cp class=\"ft220\" style=\"position: absolute; top: 266px; left: 739px; white-space: nowrap;\"\u003eElectrician’s \u003cbr\u003eMultimeter with \u003cbr\u003eNon-Contact Voltage\u003c\/p\u003e\n\u003cp class=\"ft222\" style=\"position: absolute; top: 321px; left: 644px; white-space: nowrap;\"\u003e\u003cb\u003eIncluded\u003cbr\u003e\u003c\/b\u003eTL75 Test leads, holster, User’s \u003cbr\u003emanual and 9 V battery (installed).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"None","offer_id":49232215408887,"sku":"fluke_117_new","price":271.44,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49232215441655,"sku":"nist_traceable","price":329.29,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49232215474423,"sku":"nist_traceable_data","price":342.64,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49232215507191,"sku":"17025","price":352.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_117-new_1.jpg?v=1735292779"},{"product_id":"fluke-116-fluke-multimeter-new","title":"FLUKE-116 Fluke Multimeter New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eBuilt-in thermometer for HVAC applications\u003c\/li\u003e \u003cli\u003eMicroamps to test flame sensors\u003c\/li\u003e \u003cli\u003eLow input impedance: helps prevent false readings due to ghost voltage\u003c\/li\u003e \u003cli\u003eLarge white LED backlight to work in poorly lit areas\u003c\/li\u003e \u003cli\u003eResistance, continuity, frequency and capacitance\u003c\/li\u003e \u003cli\u003eMin\/Max\/Average with elapsed time to record signal fluctuations\u003c\/li\u003e \u003cli\u003eCompact ergonomic design for one-handed operation\u003c\/li\u003e \u003cli\u003eCompatible with optional magnetic hanger (ToolPak™)\u003c\/li\u003e \u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e4 mm silicone test lead set\u003c\/li\u003e \u003cli\u003e80BK Integrated Temperature probe\u003c\/li\u003e \u003cli\u003eHolster\u003c\/li\u003e \u003cli\u003eInstalled 9 V battery\u003c\/li\u003e \u003cli\u003eUser manual\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe Fluke 116 is a true-RMS meter for HVAC (heating ventilation air conditioning) troubleshooting. The Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"None","offer_id":49232224387319,"sku":"fluke_116_new","price":275.49,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49232224420087,"sku":"nist_traceable","price":413.24,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49232224452855,"sku":"nist_traceable_data","price":422.74,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49232224485623,"sku":"17025","price":460.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_116-new_1.jpg?v=1735292798"},{"product_id":"fluke-179-esfp-fluke-multimeter-new","title":"FLUKE-179 ESFP Fluke Multimeter New","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Measuring Range DC: 600mV to 1000V\u003c\/li\u003e\n\u003cli\u003eVoltage Measuring Range AC: 600mV to 1000V\u003c\/li\u003e\n\u003cli\u003eCurrent Measuring Range, DC: 60mA to 10A\u003c\/li\u003e\n\u003cli\u003eCurrent Measuring Range, AC: 60mA to 10A\u003c\/li\u003e\n\u003cli\u003eTrue RMS voltage and current measurements\u003c\/li\u003e\n\u003cli\u003e0.09% basic accuracy\u003c\/li\u003e\n\u003cli\u003e6000 count resolution\u003c\/li\u003e\n\u003cli\u003eDigital display with analog bargraph and backlight\u003c\/li\u003e\n\u003cli\u003eManual and automatic ranging\u003c\/li\u003e\n\u003cli\u003eDisplay Hold and Auto Hold\u003c\/li\u003e\n\u003cli\u003eFrequency and capacitance measurements\u003c\/li\u003e\n\u003cli\u003eResistance, continuity and diode measurements\u003c\/li\u003e\n\u003cli\u003eTemperature measurements\u003c\/li\u003e\n\u003cli\u003eMin-max-average recording\u003c\/li\u003e\n\u003cli\u003eSmoothing mode allows filtering of rapidly changing inputs\u003c\/li\u003e\n\u003cli\u003eEasy battery exchange without opening the case\u003c\/li\u003e\n\u003cli\u003eClosed case calibration through front panel\u003c\/li\u003e\n\u003cli\u003eErgonomic case with integrated protective holster\u003c\/li\u003e\n\u003cli\u003eEN61010-1 CAT III 1000V \/ CAT IV 600V\u003c\/li\u003e\n\u003cli\u003eMeasures twice as fast as other multimeters\u003c\/li\u003e\n\u003cli\u003eIncluded Accessories: Test leads with 4 mm lantern tips and protective cap, installed 9V battery and users manual. The 179 also includes the 80BK temperature probe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Fluke 179 ESFP has the features needed to find most electrical, electronic, electro-mechanical and heating and ventilation problems. The Fluke 179 ESFP is simple to use and has significant improvements over Flukes original 70 Series like, True-RMS, frequency, capacitance, temperature, min-max record, conformance to the latest electrical safety standards, and a much larger display that is easier to view.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"None","offer_id":49232184869111,"sku":"fluke_179 esfp_new","price":451.92,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49232184901879,"sku":"nist_traceable","price":507.82,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49232184967415,"sku":"nist_traceable_data","price":520.72,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49232185032951,"sku":"17025","price":530.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_179-esfp-new_1.jpg?v=1735292825"},{"product_id":"289-fluke-multimeter-new","title":"289 Fluke Multimeter New","description":"\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth: 100 kHz\u003c\/li\u003e\n\u003cli\u003eVoltage: 1000 V (0.01 mV to 1000.0 V)\u003c\/li\u003e\n\u003cli\u003eCurrent: 10 A (0.01 A to 10 A)\u003c\/li\u003e\n\u003cli\u003eResistance: 500 MΩ  (0.01 Ω to 500 MΩ)\u003c\/li\u003e\n\u003cli\u003eContinuity\/Diode\u003c\/li\u003e\n\u003cli\u003eConductance: 0.01 nS to 50.00 nS (20 MΩ to 100 GΩ)\u003c\/li\u003e\n\u003cli\u003eCapacitance: 1 pF to 100mF (0.001 nf to 100.00mF)\u003c\/li\u003e\n\u003cli\u003eFrequency 1 MHz (0.1 Hz to 999.99 kHz)\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average, Hold, Auto and Manual Range\u003c\/li\u003e\n\u003cli\u003eTemperature: -200 ºC to +1350 ºC (Display ºC or ºF) (dBm), Selectable References or (dBV)\u003c\/li\u003e\n\u003cli\u003ePeak\/Crest Factor 250 μs Peak Min or Max (From 1.0 to 4.0)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe new 289 is the next generation high performance industrial logging multimeter designed to solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. With the ability to log data and review it graphically on-screen, you can solve problems faster and help minimize downtime. Let the new 289 be your watchdog for systems or processes while you are off solving other problems.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"None","offer_id":49232189686007,"sku":"fluke_289_new","price":959.49,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable","offer_id":49232189718775,"sku":"nist_traceable","price":1078.24,"currency_code":"USD","in_stock":true},{"title":"NIST Traceable with Full Data","offer_id":49232189751543,"sku":"nist_traceable_data","price":1092.49,"currency_code":"USD","in_stock":true},{"title":"ISO IEC 17025 Accredited","offer_id":49232189784311,"sku":"17025","price":1116.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_289-new.jpg?v=1735292883"},{"product_id":"374-fc-fluke-clamp-meter-new","title":"FLUKE-374 FC Clamp Meter New","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eConnect your meter to your smartphone with Fluke Connect Measurements\u003c\/li\u003e \u003cli\u003eRead measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks\u003c\/li\u003e \u003cli\u003eRecord results directly to your phone and the Cloud\u003c\/li\u003e \u003cli\u003eCreate and share reports from the field via email, or converse in real-time with ShareLive™ video calls\u003c\/li\u003e \u003cli\u003eCompatible with iFlex flexible current probe; use to expand the measurement range to 2500 A AC; provides access to large conductors in tight spaces\u003c\/li\u003e \u003cli\u003eCompatible with TPAK magnetic hanging strap\u003c\/li\u003e \u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e \u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e \u003cli\u003eThree-year warranty\u003c\/li\u003e \u003cli\u003eIncludes: Soft carrying case, TL75 test leads, Two AA Alkaline batteries, Coated instruction card, and Safety information sheet\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eMeasurement Capability:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e600 A AC and DC current measurement\u003c\/li\u003e \u003cli\u003e2500 A AC current measurement with (optional) iFlex flexible current probe\u003c\/li\u003e \u003cli\u003e1000 V AC and DC voltage measurement\u003c\/li\u003e \u003cli\u003eTrue-RMS voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e \u003cli\u003eResistance measurement to 6000 Ohms with continuity detection\u003c\/li\u003e \u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e \u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe Fluke 374 FC offers advanced troubleshooting performance and is now part of the Fluke Connect® family of wireless test tools.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49232547938551,"sku":"fluke_374 fc_new","price":455.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_374fc-new_1.jpg?v=1735300731"},{"product_id":"375-fc-fluke-clamp-meter-new","title":"FLUKE-375 FC Clamp Meter New","description":"\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHigh performance clamp meter that measures very low voltage and high resistance\u003c\/li\u003e \u003cli\u003eTransmits measurements to your smartphone via Fluke Connect® so you can view them at a safer distance\u003c\/li\u003e \u003cli\u003eMeasures AC and DC current to 600 A, and AC and DC voltage to 1000 V\u003c\/li\u003e \u003cli\u003eMeasures AC current to 2500 A AC with optional iFlex flexible current probe\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAC Current via Jaw\u003c\/li\u003e \u003cli\u003eRange - 600.0 A\u003c\/li\u003e \u003cli\u003eResolution - 0.1 A\u003c\/li\u003e \u003cli\u003eAccuracy - 2% ±5 digits (10 Hz to 100 Hz), 2.5% ±5 digits (100-500 Hz)\u003c\/li\u003e \u003cli\u003eCrest Factor (50 Hz\/60 Hz) - 3 @ 500 A, 2.5 @ 600 A, Add 2% for C.F. \u0026gt;2\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect. The 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlex® probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlex® flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49232555901175,"sku":"fluke_375 fc_new","price":460.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_375fc-1-new.jpg?v=1735300769"},{"product_id":"376-fc-fluke-clamp-meter-new","title":"FLUKE-376 FC Clamp Meter New","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eLog and trend measurements to pinpoint intermittent faults\u003c\/li\u003e \u003cli\u003eTransmit results wirelessly via Fluke Connect® Measurements app\u003c\/li\u003e \u003cli\u003eCreate and send reports right from the field\u003c\/li\u003e \u003cli\u003eStay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices\u003c\/li\u003e \u003cli\u003eConnect your meter to your smartphone with Fluke Connect Measurements\u003c\/li\u003e \u003cli\u003eRead measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks\u003c\/li\u003e \u003cli\u003eRecord results directly to your phone and the Cloud\u003c\/li\u003e \u003cli\u003eCapture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC\u003c\/li\u003e \u003cli\u003eCreate and share reports from the field via email, or converse in real-time with ShareLive™ video calls\u003c\/li\u003e \u003cli\u003eiFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)\u003c\/li\u003e \u003cli\u003eTPAK magnetic hanging strap (included)\u003c\/li\u003e \u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e \u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e \u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e \u003cli\u003eThree-year warranty\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eMeasurement Capability\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e1000 A ac and dc current measurement\u003c\/li\u003e \u003cli\u003e2500 A ac current measurement with iFlex flexible current probe\u003c\/li\u003e \u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e \u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e \u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e \u003cli\u003eResistance measurement to 60 k? with continuity detection\u003c\/li\u003e \u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e \u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e \u003cli\u003e1000 µF capacitance measurement\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e18-inch iFlex® Flexible Current Probe\u003c\/li\u003e \u003cli\u003eTPAK magnetic hanging strap\u003c\/li\u003e \u003cli\u003eSoft carrying case\u003c\/li\u003e \u003cli\u003eTL75 test leads\u003c\/li\u003e \u003cli\u003eTwo AA Alkaline batteries\u003c\/li\u003e \u003cli\u003eCoated instruction card\u003c\/li\u003e \u003cli\u003eSafety information sheet\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe new Fluke 376 FC Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms ac voltage and current measurements, the FlukeN 376 can read up to 1000 V and 1000 A in both ac and dc modes.\u003c\/p\u003e \u003cp\u003eAdditionally, the Fluke 376 FC includes the new iFlex™ lexible current probe expanding the measurement range to 2500 A ac while providing increased display lexibility, ability to measure around awkward sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter.\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49232547119351,"sku":"fluke_376 fc_new","price":594.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_376fc-new.jpg?v=1735300778"},{"product_id":"fluke-87v-max-fluke-multimeter-new","title":"FLUKE-87V-MAX Fluke Multimeter New","description":"\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eTrue RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e \u003cli\u003eMeasure up to 1000 V AC and DC\u003c\/li\u003e \u003cli\u003eMeasure up to 10 A (20 A for 30 seconds)\u003c\/li\u003e \u003cli\u003eFrequency to 200 kHz\u003c\/li\u003e \u003cli\u003eBuilt in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument\u003c\/li\u003e \u003cli\u003eMin\/Max\/Average recording, plus 150 μs Peak min-max to capture variations automatically\u003c\/li\u003e \u003cli\u003eUnique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs) and other electrically noisy equipment\u003c\/li\u003e \u003cli\u003eLarge display digits, 2-level bright white backlight and backlit keypad buttons for increased visibility\u003c\/li\u003e \u003cli\u003eHi resolution 20,000 count display mode\u003c\/li\u003e \u003cli\u003eLong battery life (800 hours)\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eAccessories (included):\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMultimeter\u003c\/li\u003e \u003cli\u003eTL175 Test Leads\u003c\/li\u003e \u003cli\u003eAC175 Alligator Clips\u003c\/li\u003e \u003cli\u003e80BK-A Temperature Probe\u003c\/li\u003e \u003cli\u003e3 x AA Batteries (Installed)\u003c\/li\u003e \u003cli\u003eLimited Lifetime Warranty\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMaximum Resolution 0.1 mV to 1000 V\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMaximum Resolution 0.1 mV to 1000 V\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eFeatures an IP67 rating, making this digital multimeter ideal for users that work in extreme environments such as hot, cold, wet, dirty, up ladders, and down a hole. Additionally, this instrument can troubleshoot most electrical problems. It provides a new standard for working in extreme conditions with the features and accuracy to troubleshoot a wide variety of electrical problems. This heavy-duty digital multimeter has an IP67 (waterproof and dustproof) rating, an extended operating temperature range that makes this instrument ideal in tough environments. This True RMS heavy-duty multimeter also comes equipped with a rugged case and removable holster that has been drop tested to 13.1' (4 m).\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":49232616816887,"sku":"fluke_87v-max_new","price":654.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/0443\/2631\/files\/fluke_87v-max.jpg?v=1735303567"}],"url":"https:\/\/valuetronics.com\/collections\/fluke-dmm-series-and-clamp-meters.oembed","provider":"ValueTronics","version":"1.0","type":"link"}