# Kikusui PCR36000WEA2 3P4W 400V AC/DC Power Supply NEW

**Features:**

-   Compact size: 6 kVA in 6U (PCR6000WEA2/PCR6000WEA2R)
-   Up to 36 kVA in a Single Unit
-   AC output \*1: Single-phase/Single-phase three-wire/Three-phase
-   DC output: +/-, 100% of rated power
-   [100% Regenerative-power capability](https://kikusuiamerica.com/w2-2/ac-power-supply-en-en_us/pcr-wea_wea2-en-en_us/pcr-wea-wea2-series/wea2r/)
-   Expandable up to three-phase 540 kVA※2
-   Flexible digital interface: LAN (LXI), USB, RS232C, GPIB (option)
-   Power line disturbance simulation features
-   Sequence function
-   External analog, digital control function (standard)
-   Power-saving function
-   Output frequency up to 5 kHz
-   Output rating: AC 0 to 320 Vrms, DC 0 to ±452 V

Product Images

Model

Phase

**Power capacity\[VA\]**

Phase voltage**\[V\]**

Max. current (L/H range)**\[A\]**※1

**Frequency\[Hz\]**

![PCR1000WEA](https://global.kikusui.co.jp/kiku/wp-content/uploads/2021/07/wea3000.jpg.webp)

PCR1000WEA

Single phase

1k

(The spec guaranteed voltage range)  
1 to 160/ 2 to 320  
(L/H output range)  
  
(Voltage setting range)  
0 to 161.0/ 0 to 322.0

10 / 5

1 to 5000

![PCR2000WEA](https://global.kikusui.co.jp/kiku/wp-content/uploads/2021/07/wea3000.jpg.webp)

PCR2000WEA

Single phase

2k

20 / 10

![PCR3000WEA2](https://global.kikusui.co.jp/kiku/wp-content/uploads/2021/07/wea3000.jpg.webp)

PCR3000WEA2

Single phase

3k

30 / 15

Three-phase

10 / 5

Single-phase Three-wire

2k

![PCR6000WEA](https://global.kikusui.co.jp/kiku/wp-content/uploads/2021/07/wea6000.jpg.webp)

PCR6000WEA2

Single phase

6k

60 / 30

Three-phase

20 / 10

Single-phase Three-wire

4k

![PCR1000WEA](https://global.kikusui.co.jp/kiku/wp-content/uploads/2021/07/wea12000.jpg.webp)

PCR12000WEA2

Single phase

12k

120 / 60

Three-phase

40 / 20

Single-phase Three-wire

8k

![PCR18000WEA](https://global.kikusui.co.jp/kiku/wp-content/uploads/2021/07/wea24000.jpg.webp)

PCR18000WEA2

Single phase

18k

180 / 90

Three-phase

60 / 30

Single-phase Three-wire

12k

![PCR24000WEA](https://global.kikusui.co.jp/kiku/wp-content/uploads/2021/07/wea24000.jpg.webp)

PCR24000WEA2

Single phase

24k

240 / 120

Three-phase

80 / 40

Single-phase Three-wire

16k

![PCR30000WEA](https://global.kikusui.co.jp/kiku/wp-content/uploads/2021/07/wea36000.jpg.webp)

PCR30000WEA2

Single phase

30k

300 / 150

Three-phase

100 / 50

Single-phase Three-wire

20k

![PCR36000WEA](https://global.kikusui.co.jp/kiku/wp-content/uploads/2021/07/wea36000.jpg.webp)

PCR36000WEA2

Single phase

36k

360 / 180

Three-phase

120 / 60

Single-phase Three-wire

24k

Input

Model

Single-phase output

Single-phase/three-phase switchable model

 

 

PCR1000WEA

PCR2000WEA

PCR3000WEA2

PCR6000WEA2

PCR12000WEA2

PCR18000WEA2

PCR24000WEA2

PCR30000WEA2

PCR36000WEA2

 

 

PCR6000WEA2R

PCR12000WEA2R

PCR18000WEA2R

PCR24000WEA2R

PCR30000WEA2R

PCR36000WEA2R

Nominal input voltage

1P2W input model

100 Vac to 120 Vac / 200 Vac to 240 Vac \*1

–

3P3W 200 V input model / 3P3W 400 V input model

–

200 Vac to 240 Vac (3 phase line voltage) \*2 / 380 Vac to 480 Vac (3 phase line voltage) \*2 \*6

3P4W input model

–

380 Vac to 480 Vac (3 phase line voltage) \*3

Phase

Single-phase

Three-phase

Nominal input Frequency

50 Hz to 60 Hz

Input frequency range

45 Hz to 65 Hz

Apparent power

1.4 kVA and less

2.7 kVA and less

4 kVA and less

7.8 kVA and less

15.6 kVA and less

23.4 kVA and less

31.2 kVA and less

39 kVA and less

46.8 kVA and less

Power factor \*4

0.95(TYP)

200 V: 0.97(TYP), 400 V: 0.95(TYP) 3P3W input model / 0.95(TYP) 3P4W input model

Maximum current

1P2W input model \*1

17 A / 8.5 A

32 A / 16 A

48 A / 24 A

–

3P3W 200 V input model

–

27 A

53 A

80 A

106 A

133 A

159 A

3P3W 400 V input model

 

14 A

28 A

42 A

56 A

70 A

84 A

3P4W input model

–

14 A

28 A

42 A

56 A

70 A

84 A

Hold-up time for power interruption \*4

10 ms

Protective conductor current \*5

1P2W input model

3.5 mA or less

–

3P3W 200 V input model

–

10 mA or less

15 mA or less

20 mA or less

25 mA or less

30 mA or less

35 mA or less

3P3W 400 V input model

–

10 mA or less

20 mA or less

30 mA or less

40 mA or less

50 mA or less

60 mA or less

3P4W input model

–

3.5 mA or less

\*1 100 V/200 V input system (auto select) \*2 Models with an “R” in the name (6 kVA or higher) have a three-phase, three-wire input. \*3 Models of 6 kVA or more without an “R” in the name have three-phase 4-wire input. \*4 At output voltage 100 V/200 V, rated output current, sine wave, load power factor 1, output frequency 40 Hz to 1 kHz \*5 At output voltage 100 V/200 V, rated output current, sine wave, load power factor 1, output frequency 45 Hz to 65 Hz \*6 For the 400V input model, do not connect to transformer equipment with isolation voltage exceed-ing 300 V. It cannot be connected to a delta-connected power distribution facility with one pole grounded.

Output

Model

Single-phase output

Single-phase/three-phase switchable model

 

 

PCR1000WEA

PCR2000WEA

PCR3000WEA2

PCR6000WEA2

PCR12000WEA2

PCR18000WEA2

PCR24000WEA2

PCR30000WEA2

PCR36000WEA2

 

 

PCR6000WEA2R

PCR12000WEA2R

PCR18000WEA2R

PCR24000WEA2R

PCR30000WEA2R

PCR36000WEA2R

Maximum peak current \*11

4 times the maximum output current

Inrush current capacity \*3

3 times the rated current (0.07 s) \*12  
1.4 times the rated current (0.5 s)

1.4 times the rated current (0.5 s)

Efficiency \*10

82 %(TYP)

85 %(TYP)

AC Voltage

Rating

160 V / 320 V \*2

Setting range

0 V to 161.0 V, 0 V to 322.0 V

Resolution

0.1 V

Setting accuracy (phase voltage) \*3 \*4

±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)

Setting accuracy (Line voltage) \*3 \*4

±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) \*5

Maximum current \*1 \*6

Single-phase output

10 A / 5 A

20 A / 10 A

30 A / 15 A

60 A / 30 A

120 A / 60 A

180 A / 90 A

240 A / 120 A

300 A / 150 A

360 A / 180 A

Single-phase three-wire output, Three-phase output

–

10 A / 5 A

20 A / 10 A

40 A / 20 A

60 A / 30 A

80 A / 40 A

100 A / 50 A

120 A / 60 A

Phase

1P

1P2W, 1P3W, 3P4W switchable

Power capacity

Single-phase output

1 kVA

2 kVA

3 kVA

6 kVA

12 kVA

18 kVA

24 kVA

30 kVA

36 kVA

Three-phase output

–

3 kVA

6 kVA

12 kVA

18 kVA

24 kVA

30 kVA

36 kVA

Single-phase three-wire output

–

2 kVA

4 kVA

8 kVA

12 kVA

16 kVA

20 kVA

24 kVA

Load power factor

0 to 1 (leading or lagging)

Frequency

Setting range

1 Hz to 5 kHz \*7 (5 kHz -3dB, <40 Hz derating required)

Resolution

0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)

Accuracy \*3

±0.01 %, Temperature coefficient : ±0.005 %/°C

Phase

Resolution

–

0.01\*13 , 0.1° (1 Hz to 500 Hz), 1° (500 Hz to 4 kHz), 2° (4 kHz or more)

Accuracy \*3

–

Within ±(0.4° + fo×0.9°) \*8 fo: frequency \[kHz\] \[kHz\]

DC Voltage

voltage

Rating \*1

\-226 V to +226 V, -452 V to +452 V \*2

Setting range \*1

\-227.5 V to +227.5 V, -455.0 V to +455.0 V

Resolution

0.1 V

Accuracy \*9

±（0.05 % of setting + 0.1 V）

Maximum current \*6

10 A / 5 A

20 A / 10 A

30 A / 15 A

60 A / 30 A

120 A / 60 A

180 A / 90 A

240 A / 120 A

300 A / 150 A

360 A / 180 A

Power capacity

1 kW

2 kW

3 kW

6 kW

12 kW

18 kW

24 kW

30 kW

36 kW

1 output L range, output H range \*2 Specification guaranteed voltage range is 1 V to 160 V/ 2 V to 320 V (AC) and 1.4 V to 226 V/ 2.8 V to 452 V (DC) \*3 At ambient temperature of 23 °C±5 °C. \*4 No load, output frequency 45 Hz to 65 Hz \*5 When the phase angle of 120° of each phase. \*6 For output phase voltage of 100 Vac to 160 Vac/ 200 Vac to 320 Vac and out-put voltage of 100 Vdc to 226 Vdc/ 200 Vdc to 452 Vdc, output current is reduced with output voltage.  
When the output frequency is between 1 Hz and 40 Hz, the output current is reduced by the output frequency. The output current is 70 % at 1 Hz. \*7 On the 500 Hz limit model, the frequency is limited to 1 Hz to 500.0 Hz for three-phase output. \*8 Within ±(0.4° + 2.5 μs×360°×fo×103). The following show the angles obtained by calculating the expression with the specified frequency, within ± 0.5° (at 60 Hz output), within ± 0.8° (at 400 Hz output) \*9 With no load at 23°C±5°C. \*10 When the output voltage is 100 V or 200 V, the output current is the rated value, the load power factor is 1, and the output frequency is between 40 Hz and 1 kHz. \*11 Repeated output is possible when the crest factor is 4. \*12 125 Vac/ 250 Vac (output L range/ H range) \*13 Waveform bank 0, at 1 Hz to 500 Hz.

Output Voltage Stability (Phase Voltage)

Model

Single-phase output

Single-phase/three-phase switchable model

 

PCR1000WEA

PCR2000WEA

PCR3000WEA2

PCR6000WEA2

PCR12000WEA2

PCR18000WEA2

PCR24000WEA2

PCR30000WEA2

PCR36000WEA2

 

PCR6000WEA2R

PCR12000WEA2R

PCR18000WEA2R

PCR24000WEA2R

PCR30000WEA2R

PCR36000WEA2R

Line regulation \*1

Within ±0.1 %

Load regulation \*2

Within ±0.1 V/ ±0.2 V(1 Hz to 100 Hz)  
Within ±0.3 V/ ±0.6 V(100.1 Hz to 500 Hz)  
Within ±1 V/ ±2 V(500.1 Hz to 1 kHz)

Within ±0.2 V/ ±0.4 V(1 Hz to 100 Hz)  
Within ±0.3 V/ ±0.6 V(100.1 Hz to 500 Hz)  
Within ±1 V/ ±2 V(500.1 Hz to 1 kHz)

Output frequency variation \*3

When the output voltage correction function is enabled : Within ±0.3 %(1 Hz to 1 kHz), Within ±10 %(1001 Hz to 5 kHz) When the output voltage correction function is disabled : Within -3 dB(5 kHz)

Ripple noise \*4

≤ 0.25 Vrms

Ambient temperature variation \*5

±100 ppm/ °C (TYP)

Total harmonic distortion \*6

0.3 % and less(1 Hz to 100 Hz), 0.5 % and less(100.1 Hz to 330 Hz), 1.5 %/kHz and less(330.1 Hz to 5 kHz)

Transient response \*7

Response FAST : 40 μs(TYP)

Response speed Tr/Tf \*8

Response FAST : 40 μs(TYP) Response MEDIUM : 100 μs(TYP) Response SLOW : 300 μs(TYP)

\* 1 With respect to changes in the rated range of input voltage. 2 With respect to 0 % to 100 % changes in the rating of output current. When the output phase voltage is between 80 V and 160 V (L range) or 160 V and 320 V (H range) and the load power factor is 1, and the response is FAST. At the output terminal block, when the compensation function is not used. \* 3 Voltage variation over 40 Hz to 5 kHz in AC mode with 55 Hz as the reference. When the output phase voltage is between 80 V and 160 V or 160 V and 320 V and the load power factor is 1, and the response is FAST, at the output terminal block. \* 4 5 Hz to 1 MHz components in DC mode. \* 5 With respect to changes in the operating temperature range. When the output phase voltage is 100 V or 200 V, with no load. \* 6 When the output phase voltage is between 80 V and 160 V or 160 V and 320 V and the load power factor is 1, and the response is FAST, at the output terminal block. \* 7 When the output voltage is 100 V or 200 V, the load power factor is 1, and the output current changes from 0 A to the rated value and from the rated value to 0 A. \* 8 At 10 % to 90 % of the output voltage.

The PCR6000WEA2 3P4W 400V (500Hz) from Kikusui is an ultra-compact AC/DC power supply with a power rating of 6000 watts. It operates at a voltage of 320 volts and delivers a current of 60 amperes. This model features a single output and supports remote control functionality, allowing for convenient operation. The power supply is designed to work with a three-phase, four-wire 400-volt system and can handle frequencies up to 500 hertz. Its compact design makes it suitable for applications requiring a reliable and efficient power source within a limited space. The combination of high power output and remote control capability provides flexibility for various industrial and testing environments.

**\*The image is for reference only. See product specification for details.**

## Details

- **Price:** 85000.0 USD
- **Vendor:** Kikusui
- **Type:** AC Power Sources
- **Tags:** AC & DC Power Supply Testers, AC Power Source, Buy New Eqiupment, Buy New Equipment AVADA, DC Power Supplies, DC Power Supply, Factory New, Julie's Products, Kikusui, Manufacturers, New, New Item Review, Other Equipment, product_manual_group_3, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 85000.00 USD | In stock |

## Images

- Kikusui PCR36000WEA2 3P4W 400V AC/DC Power Supply NEW

---

> Source: [ValueTronics](https://valuetronics.com/products/pcr36000wea2-3p4w-400v-new-kikusui-ac-supply-new)
> Updated: 2026-08-07