# Keysight P5004A 20 GHz 2-Port Streamline Series Vector Network Analyzer (Pre-Owned)

# Keysight P5004A 20 GHz 2-Port Streamline Series Vector Network Analyzer (Pre-Owned)

## Key Features At A Glance

-   Compact, portable vector network analyzer controlled by an external PC over USB
-   Available in 2-, 4-, and 6-port configurations across the A-model series
-   Upper frequency limits span 4.5 GHz to 53 GHz across the series (6-port models up to 20 GHz)
-   Up to 140 dB system dynamic range (150 dB typical) at the test port
-   Built for testing passive components, amplifiers, mixers, and frequency converters
-   Damage input level of +27 dBm or ±35 VDC (warranted) on all models
-   Optional spectrum analysis, pulsed-RF, and TDR time-domain software (separate license required per application)
-   USB 3.0 host link, 10 MHz reference in/out, and two SMB trigger ports for automated test setups

The Keysight P50xxA Streamline Series is a portable vector network analyzer family delivered in a compact chassis and controlled by an external computer, bringing high-end network-analysis performance to a benchtop or field footprint. The series spans 2-port models (P500xA) and 4- or 6-port models (P502xA), with coverage up to 53 GHz on 2- and 4-port models and up to 20 GHz on 6-port models. Across the family the VNA is positioned for fast, reliable, and repeatable measurements with key specifications including dynamic range, measurement speed, trace noise, and temperature stability.

As a vector network analyzer, the P50xxA characterizes how a device responds to RF stimulus across frequency — magnitude and phase of reflection and transmission. The series is intended for the complete characterization of passive components, amplifiers, mixers, and frequency converters. A portfolio of software applications extends the compact analyzer into a broader RF measurement solution, including spectrum analysis, pulsed-RF measurement, enhanced time-domain analysis with TDR, and multi-instrument or multi-site configurations.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments we list are equipment we keep on hand. Every pre-owned unit is supported by our team of test-and-measurement specialists; each used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received.

## Brand Heritage

Keysight Technologies traces its measurement heritage to Hewlett-Packard. HP's test-and-measurement business was spun out as Agilent Technologies in 1999, and that business was established as Keysight Technologies in 2014.

## Compare Other Models in This Series

The Streamline Series A-models share a common portable, PC-controlled architecture and differ primarily in port count and upper frequency limit. The 2-port P500xA models and 4-/6-port P502xA models all use the same compact chassis and external-PC control, and all carry the family's key specifications for dynamic range, measurement speed, trace noise, and temperature stability.

Within the series, 2- and 4-port models reach up to 53 GHz, while 6-port models extend the test-port count at up to 20 GHz. A second internal source is available on certain 4-port configurations, and multiple units can be combined into a single multiport analyzer with the appropriate software.

Each pre-owned model linked below is its own dedicated product page with condition-matched pricing, so you can select the exact port count and frequency tier your application requires and see the price for that specific configuration.

The models differ mainly along three axes: number of test ports (2, 4, or 6), upper frequency limit, and test-port connector type. Test-port connectors are 3.5 mm female on the lower-frequency models, 2.4 mm female on the 32 GHz and 44 GHz models, and 1.85 mm female on the 53 GHz models.

Upper frequency coverage ranges from 4.5 GHz to 53 GHz across the A-model series, and corresponding TDR step rise time, impulse width, and maximum eye-diagram data rate scale with each model's bandwidth. Consult the comparison table that follows for the per-model frequency limit, port count, and connector type.

Model

Frequency Range

Test Ports

Connector Type

**P5004A**

9 kHz to 20 GHz

2

3.5 mm female

P5000A

9 kHz to 4.5 GHz

2

3.5 mm female

P5001A

9 kHz to 6.5 GHz

2

3.5 mm female

P5002A

9 kHz to 9 GHz

2

3.5 mm female

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Product Core & Specifications

Specification

Value

Key Specifications

Frequency range

9 kHz to 20 GHz

Number of test ports

2

Test port connector type

3.5 mm female

Test port impedance

50 Ω (nominal)

Nominal (preset) power level

0 dBm

Damage input level

+27 dBm or ± 35 VDC (warranted)

System Dynamic Range at Test Port — dB (Specification)

9 kHz to 100 kHz

101

100 kHz to 300 kHz

117

300 kHz to 1 MHz

125

1 MHz to 10 MHz

130

10 MHz to 50 MHz

137

50 MHz to 3 GHz

140

3 GHz to 5 GHz

140

5 GHz to 6.5 GHz

140

6.5 GHz to 9 GHz

136

9 GHz to 14 GHz

133

14 GHz to 16 GHz

130

16 GHz to 20 GHz

126

Maximum Output Port Power — dBm (Specification)

9 kHz to 100 kHz

0

100 kHz to 10 MHz

5

10 MHz to 4.5 GHz

10

4.5 GHz to 6.5 GHz

10

6.5 GHz to 9 GHz

9

9 GHz to 16 GHz

7

16 GHz to 20 GHz

4

Test Port Noise Floor — dBm (Specification)

9 kHz to 100 kHz

\-101

100 kHz to 300 kHz

\-112

300 kHz to 1 MHz

\-120

1 MHz to 10 MHz

\-125

10 MHz to 50 MHz

\-127

50 MHz to 3 GHz

\-130

3 GHz to 4.5 GHz

\-130

4.5 GHz to 6.5 GHz

\-130

6.5 GHz to 9 GHz

\-127

9 GHz to 14 GHz

\-126

14 GHz to 16 GHz

\-123

16 GHz to 20 GHz

\-122

Enhanced Time Domain Analysis / TDR (with S97011B)

Bandwidth

20 GHz

DC damage level at test port

35 V

Maximum test port input voltage (Hot TDR)

1.5 Vpp (typical)

TDR step rise time (min, 10% to 90%)

22.3 ps

TDR step response resolution (εr = 1, min)

3.3 mm

TDR impulse width (min)

30.2 ps

DUT length (max)

13.8 μs

TDR stimulus repetition rate (max)

19.9 MHz

Eye diagram data rate (max)

16 Gb/s

Physical

Width

176 mm (6.93 in.)

Height

48 mm (1.89 in.)

Depth

333 mm (13.11 in.)

Weight

1.88 kg (4.14 lbs)

> **Important:** Damage input level: +27 dBm or ±35 VDC (warranted).

> **Important:** The P50xxA Streamline Series VNA is controlled by an external computer and is not a standalone benchtop instrument. A host PC meeting the stated system requirements (Windows 10 or 11 64-bit, USB 3.0 port directly connected to the Intel chipset, Keysight IO Libraries) is required to operate the analyzer and is not included.

> **Important:** Advanced measurement modes require separately ordered hardware options and software licenses: spectrum analysis requires Option 090/190 with S97090B software; pulsed-RF measurements require Option 021/022 with S97024B or S97025B software; enhanced time domain analysis (TDR) requires S97011B software; multi-instrument (multiport) operation requires S97551B software.

> **Important:** For multi-instrument (multiport) configuration of two P50xxA VNAs, the interconnect cables included in the Y1701A must be used; P50xxA units cannot be combined with P50xxB/P937xA/P93xxB units to configure a multiport VNA due to hardware differences.

> **Important:** If using a power sensor (wideband power detector) to measure or calibrate the power level above 45 GHz, an external filter is required to reduce sub-harmonics (applies to the 50 GHz/53 GHz models). Refer to the VNA webhelp for more details.

> Recommended pairing: use a Keysight ECal module (such as the N4691D or N4694D) or a mechanical calibration kit named in the corrected-performance tables to obtain error-corrected measurements.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Keysight
- **Type:** Net Ana
- **Tags:** product_manual_group_3

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 0.00 USD | In stock |

## Images

- Keysight P5004A 20 GHz 2-Port Streamline Series Vector Network Analyzer (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/p5004a-keysight-network-analyzer-used)
> Updated: 2026-06-20
