# Agilent N9342C 100 kHz to 7 GHz Handheld Spectrum Analyzer (Pre-Owned)

# Agilent N9342C 100 kHz to 7 GHz Handheld Spectrum Analyzer (Pre-Owned)

## Key Features At A Glance

-   100 kHz to 7 GHz frequency range, tunable down to 9 kHz (AC coupled)
-   Field-ready handheld operating from -10 to +50 °C; 3.2 kg with a 6.5 in TFT color display
-   Displayed average noise level to -142 dBm with preamp off (specified measurement conditions apply)
-   Resolution bandwidth from 10 Hz to 3 MHz in a 1-3-10 sequence
-   LAN (RJ-45, 10Base-T), USB host, and USB device interfaces standard
-   Up to 4 hours of battery operating time on a fully charged battery
-   Optional tracking generator, RF preamplifier, cable & antenna test, modulation analysis, and GPS
-   Optional task planner automates test setup and reporting, reducing setup time by 95%

The Agilent N9342C is a handheld spectrum analyzer (HSA) covering a frequency range of 100 kHz to 7 GHz, tunable down to 9 kHz, on an AC-coupled, 50 Ω Type-N input. Built for field use, it pairs benchtop measurement performance with a rugged, portable form factor: a 6.5 in (170 mm) TFT color display at 640 × 480 resolution, a weight of 3.2 kg, and battery operation, so the instrument can be carried into the environments where signals actually live.

Designed to make field measurements easier, the N9342C operates across a -10 to +50 °C temperature range and runs up to four hours on a fully charged battery, suiting it to routine field testing where bench instruments cannot go. Through its option set it extends into cable and antenna test, channel scanning, AM/FM and ASK/FSK modulation analysis, time-gated spectrum analysis, and high-accuracy power measurement, letting a single handheld cover a broad span of field tasks.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned instrument is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer, so buyers get the right instrument in the condition they expect, backed by people who know the equipment.

## Brand Heritage

The Agilent name traces to Hewlett-Packard, whose test and measurement business was spun off as Agilent Technologies in 1999. Agilent's electronic measurement division was subsequently established as Keysight Technologies in 2014.

## Product Core & Specifications

Specification

Value

Frequency

Frequency range

100 kHz to 7 GHz (tunable to 9 kHz), AC coupled

Internal 10 MHz frequency reference - aging rate

± 1 ppm/year

Internal 10 MHz frequency reference - temperature stability

± 1 ppm (referenced to frequency reading at 25 °C, temperature varied at max. 2 °C per minute)

Frequency readout marker resolution

(frequency span)/(sweep points - 1)

Frequency readout uncertainty

± (frequency indication × frequency reference uncertainty + 1% × span + 20% × resolution bandwidth + marker resolution + 1 Hz)

Marker frequency counter - resolution

1 Hz

Marker frequency counter - accuracy

± (marker frequency × frequency reference uncertainty + counter resolution)

Frequency span - range

0 Hz (zero span), 100 Hz to 7 GHz

Frequency span - resolution

1 Hz

Frequency span - accuracy

± (0.22% × span + span/(sweep points - 1))

SSB Phase Noise (Nominal, center frequency 500 MHz, 20 to 30 °C)

30 kHz offset

< -86 dBc/Hz, typical -89 dBc/Hz

100 kHz offset

< -97 dBc/Hz, typical -99 dBc/Hz

1 MHz offset

< -115 dBc/Hz, typical -119 dBc/Hz

Resolution Bandwidth (RBW)

\-3 dB bandwidth

10 Hz to 3 MHz (1-3-10 sequence)

Accuracy

± 5%, RBW = 10 Hz to 1 MHz; ± 10%, RBW = 3 MHz (nominal)

Resolution filter shape factor

< 5:1 (nominal; 60 dB/3 dB bandwidth ratio; digital, Gaussian-like)

Video Bandwidth (VBW)

\-3 dB bandwidth

1 Hz to 3 MHz (1-3-10 sequence)

Accuracy

± 10%, VBW = 1 Hz to 1 MHz (nominal)

Amplitude

Measurement range (100 kHz to 2 MHz)

Displayed average noise level (DANL) to +10 dBm (preamp off)

Measurement range (2 MHz to 7 GHz)

Displayed average noise level (DANL) to +20 dBm (preamp off)

Input attenuator range

0 to 50 dB, in 1 dB steps

Maximum safe input - average continuous power

+33 dBm, 3 minutes maximum (input attenuator setting ≥ 20 dB, 2 MHz to 7 GHz)

Maximum safe input - DC voltage

± 50 VDC maximum

Displayed Average Noise Level (DANL), Preamp Off

100 kHz to 1 MHz

\-108 dBm, typical -127 dBm

1 to 10 MHz

\-128 dBm, typical -146 dBm

10 to 500 MHz

\-142 dBm, typical -146 dBm

500 MHz to 2.5 GHz

\-141 dBm, typical -145 dBm

2.5 to 4 GHz

\-140 dBm, typical -144 dBm

4 to 6 GHz

\-138 dBm, typical -142 dBm

6 to 7 GHz

\-136 dBm, typical -140 dBm

Displayed Average Noise Level (DANL), Preamp On

100 kHz to 1 MHz

\-131 dBm, typical -150 dBm

1 to 10 MHz

\-148 dBm, typical -163 dBm

10 to 500 MHz

\-161 dBm, typical -164 dBm

500 MHz to 2.5 GHz

\-159 dBm, typical -162 dBm

2.5 to 4 GHz

\-158 dBm, typical -161 dBm

4 to 6 GHz

\-155 dBm, typical -158 dBm

6 to 7 GHz

\-150 dBm, typical -154 dBm

Amplitude Display and Detection

Level display range - log scale

10 to 100 dB, 10 divisions displayed, 1, 2, 5, 10 dB/division

Level display range - linear scale

0 to 100%, 10 divisions displayed

Scale units

dBm, dBmV, dBμV, W, V, dBmV EMF, dBμV EMF, V EMF

Sweep (trace) points

461

Marker level readout resolution - log scale

0.01 dB

Marker level readout resolution - linear scale

≤ 1% of signal level (nominal)

Detectors

Normal, positive peak, sample, negative peak, average (video, RMS, voltage)

Number of traces

4

Trace functions

Clear/write, maximum hold, minimum hold, average

Level measurement error

± 1.5 dB (excluding input VSWR mismatch; 20 to 30 °C, 30 to 70% RH, peak detector, preamp off, input signal -50 to 0 dBm, 95th percentile, Swp Time Rule set to Accuracy; adds ± 0.3 dB when Swp Time Rule set to Speed)

Reference Level

Setting range

\-100 to 30 dBm (steps of 1 dB)

Setting resolution - log scale

0.01 dB

Setting resolution - linear scale

Same as log (2.236 µV to 7.07 V)

Accuracy

0

RF Input VSWR (at tuned frequency)

10 MHz to 3 GHz

< 1.5:1 (nominal, 10 or 20 dB attenuation)

3 to 7 GHz

< 2.0:1

Spurious Response

Second harmonic distortion

< -65 dBc, 50 MHz to 3 GHz; < -70 dBc, 3 to 7 GHz (mixer signal level at -30 dBm, input attenuation 0 dB, preamp off, 20 to 30 °C)

Third order intermodulation distortion (third order intercept)

+7 dBm, 50 to 300 MHz; +10 dBm, 300 MHz to 7 GHz

Input related spurious

< -75 dBc (-30 dBm signal at input mixer)

Inherent residual response

< -90 dBm, typical -98 dBm (input terminated and 0 dB RF attenuation, preamplifier off)

Sweep

Sweep time range

2 ms to 1000 s (span ≥ 100 Hz); 600 ns to 200 s (zero span)

Sweep mode

Continuous, single

Sweep time rule

Accuracy, speed

Trigger source

Free run, video, external, RF burst

Trigger slope

Selectable positive or negative edge

Trigger delay

± 12 ms to ± 12 s (nominal, zero span)

Front Panel Input/Output

RF input - connector and impedance

Type-N female, 50 Ω (nominal)

10 MHz reference/external trigger input - reference input frequency

10 MHz

10 MHz reference/external trigger input - reference input amplitude

0 to +10 dBm

External trigger voltage

5 V TTL level (nominal)

10 MHz reference/external trigger connector

BNC female, 50 Ω (nominal)

Probe power - voltage/current

+15 Vdc, ± 7% at 0 to 150 mA (nominal); -12.6 Vdc, ± 10% at 0 to 150 mA (nominal)

Connectivity

USB host

USB Type-A female, compatible with USB 2.0 full speed

USB device

USB Type-mini AB female, compatible with USB 2.0 full speed

LAN

RJ-45, 10 Base-T

General - Display

Resolution

640 pixels x 480 pixels

Size and type

170 mm (6.5 in) TFT color display

Languages (on-screen GUI)

English, Simplified Chinese, Traditional Chinese, French, German, Italian, Japanese, Korean, Russian, Spanish, Portuguese

General - Power Requirements and Calibration

Adaptor voltage

100 to 240 V AC, 50 to 60 Hz, auto-ranging; 15 V DC, 5.3 A, 80 W max

Power consumption

15 W (typical)

Battery operating time (fully charged battery)

4 hours (tracking generator off, preamplifier on); 3 hours (tracking generator on, preamplifier on)

> **Important:** Maximum safe input level: +33 dBm average continuous power (3 minutes maximum, input attenuator setting ≥ 20 dB, 2 MHz to 7 GHz) and ±50 VDC maximum.

> **Important:** High accuracy power measurement (Option PWM) requires an Agilent U2000 Series USB power sensor; frequency range (9 kHz to 24 GHz) and dynamic range (-60 to +44 dBm) are sensor dependent.

> **Important:** Option GPS uses a built-in GPS antenna; an external GPS antenna (N934xC-GPA) is offered as an optional accessory and is connected via the SMA-F external GPS antenna connector.

> **Important:** Specifications apply to temperatures ranging from -10 to 50 °C unless otherwise noted, and require the analyzer to be within its calibration cycle and turned on at least 30 minutes.

> Recommended pairing: the optional high-accuracy power measurement capability supports the Agilent U2000 Series USB power sensor for power measurements from 9 kHz to 24 GHz.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD - 1330.0 USD
- **Vendor:** Agilent
- **Type:** Spec An
- **Tags:** Agilent, Agilent Keysight, Analyzers, Manufacturers, product_manual_group_1, Product_used, Spectrum

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 700.00 USD | In stock |
| NIST Traceable with Full Data | 1050.00 USD | In stock |
| ISO IEC 17025 Accredited | 1330.00 USD | In stock |

## Images

- N9342C Agilent Spectrum Analyzer

---

> Source: [ValueTronics](https://valuetronics.com/products/n9342c-agilent-spectrum-analyzer-used)
> Updated: 2026-07-06