# Keysight N5244B 43.5 GHz PNA-X Network Analyzer (Pre-Owned)

# Keysight N5244B 43.5 GHz PNA-X Network Analyzer (Pre-Owned)

## Key Features At A Glance

-   Frequency coverage from 10 MHz to 43.5 GHz (N5244B) or 50 GHz (N5245B) across the PNA-X series
-   Available in 2-port and 4-port test-set configurations to match channel-count needs
-   GPIB (IEEE-488), 1G/10G LAN, and USB interfaces standard for ATE and remote control
-   System IF bandwidth selectable from 1 Hz to 15 MHz (nominal)
-   Optional low frequency extension (Option 425, N5245B) reaches down to 900 Hz
-   Optional noise-figure hardware (Option 029) and licensed applications for compression, IMD, and phase noise
-   12.1 in color LCD (1280 x 800) with 2.4 mm test port connectors

The Keysight N5244B and N5245B are PNA-X microwave network analyzers offered in two- and four-port test-set configurations. The N5244B covers 10 MHz to 43.5 GHz and the N5245B covers 10 MHz to 50 GHz, with both providing 1 Hz frequency resolution and ±0.7 ppm frequency accuracy. They measure the magnitude and phase response of microwave components and form the platform for a range of source, receiver, and software configurations.

These analyzers characterize active and passive microwave components. The published specifications cover amplifier measurements — noise figure, gain compression, and swept intermodulation distortion — as well as frequency-converter (mixer) measurements including scalar mixer conversion with phase, converter noise figure, converter gain compression, and converter swept intermodulation distortion. Absolute, single-channel residual, and two-channel residual phase-noise and AM-noise sensitivity are also specified, along with group-delay measurement.

ValueTronics keeps its inventory in-house, stocking and holding test-and-measurement equipment in our own 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit is inspected and functionally verified by our technicians before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

## Brand Heritage

Keysight Technologies traces its test-and-measurement heritage to Hewlett-Packard, whose measurement business was spun off as Agilent Technologies in 1999. Agilent's electronic measurement division then became Keysight Technologies in 2014, the name under which the PNA-X analyzers are produced today.

## Compare Other Models in This Series

The PNA-X family on this page comprises two microwave network analyzers built on a common platform: the N5244B, which spans 10 MHz to 43.5 GHz, and the N5245B, which spans 10 MHz to 50 GHz. Both are offered in two-port and four-port test-set configurations and share the same receiver architecture, IF bandwidth range, display, and remote-control interfaces.

Beyond base frequency coverage, each model is available with a range of option configurations that add source and receiver attenuators for extended power range, an internal second source with combiner and mechanical switches, bias-tees, and high-accuracy noise-figure hardware (Option 029). A low frequency extension option (Option 425), available on the N5245B, lowers the start frequency to 900 Hz.

Each model linked below has its own dedicated product page with condition-matched pricing. Select the pre-owned listing that matches the model and frequency coverage your application requires; the comparison table summarizes how the models differ so you can confirm the right configuration before ordering.

The primary difference between the two models is upper frequency limit: the N5244B reaches 43.5 GHz while the N5245B reaches 50 GHz. The low frequency extension (Option 425), which lowers the start frequency to 900 Hz (500 Hz typical), is specified for the N5245B only.

Within each model, the option suffix indicates the test-set configuration: two-port options begin with 2 (for example 201, 217, 219, 222, 224) and four-port options begin with 4 (for example 401, 417, 419, 422, 423). Higher option numbers add capabilities such as source and receiver attenuators, an internal second source with combiner and switches, and bias-tees. Refer to the comparison table for the configuration and frequency details of each listing.

Model

Frequency Range

Max Frequency

Nominal (Preset) Power

**N5244B**

10 MHz to 43.5 GHz

43.5 GHz

\-5 dBm

N5245B

10 MHz to 50 GHz

50 GHz

\-15 dBm

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   Bottom feet
-   Handles
-   Front and rear panel hardware

## Product Core & Specifications

Specification

Value

Frequency Information (All Options)

N5244B frequency range

10 MHz to 43.5 GHz

Frequency resolution

1 Hz

Frequency accuracy

± 0.7 ppm

Initial frequency accuracy

± 0.2 ppm

Frequency stability

±0.05 ppm, -10° to 70° C; ±0.5 ppm (first year)

System Dynamic Range at Test Port (dB), Options 201 or 401 (Specification, Ports 1, 3)

10 MHz to 50 MHz

91

50 MHz to 100 MHz

107

100 MHz to 500 MHz

113

500 MHz to 1 GHz

130

1 GHz to 2 GHz

132

2 GHz to 3.2 GHz

129

3.2 GHz to 10 GHz

133

10 GHz to 16 GHz

130

16 GHz to 20 GHz

129

20 GHz to 26.5 GHz

130

26.5 GHz to 30 GHz

125

30 GHz to 32 GHz

126

32 GHz to 35 GHz

127

35 GHz to 40 GHz

123

40 GHz to 43.5 GHz

122

Test Port Noise Floor (dBm) @ 10 Hz IFBW, All Options (Specification, Test Port)

10 MHz to 50 MHz

\-70

50 MHz to 100 MHz

\-85

100 MHz to 500 MHz

\-90

500 MHz to 1 GHz

\-106

1 GHz to 2 GHz

\-110

2 GHz to 10 GHz

\-110

10 GHz to 26.5 GHz

\-111

26.5 GHz to 40 GHz

\-108

40 GHz to 43.5 GHz

\-109

Maximum Leveled Power (dBm), Options 201 or 401 (Specification, Ports 1, 3, Hi Power Mode)

10 MHz to 50 MHz

12

50 MHz to 500 MHz

13

500 MHz to 1 GHz

13

1 GHz to 2 GHz

13

2 GHz to 3.2 GHz

13

3.2 GHz to 10 GHz

13

10 GHz to 16 GHz

13

16 GHz to 26.5 GHz

13

26.5 GHz to 30 GHz

12

30 GHz to 32 GHz

11

32 GHz to 35 GHz

12

35 GHz to 43.5 GHz

9

0.1 dB Compression, All Options, All Ports (Typical)

10 MHz to 10 GHz

15 dBm

10 GHz to 43.5 GHz

13 dBm

Uncorrected System Performance — Directivity, All Options, All Ports (Specification, dB)

10 MHz to 50 MHz

18

50 MHz to 200 MHz

22

200 MHz to 500 MHz

23

500 MHz to 3.2 GHz

23

3.2 GHz to 10 GHz

22

10 GHz to 13.5 GHz

18

13.5 GHz to 16 GHz

18

16 GHz to 20 GHz

18

20 GHz to 24 GHz

16

24 GHz to 35 GHz

16

35 GHz to 43.5 GHz

15

Uncorrected System Performance — Source Match, Options 201/21x/22x/401/41x/42x, All Ports (Specification, dB)

10 MHz to 50 MHz

10

50 MHz to 200 MHz

18

200 MHz to 500 MHz

18

500 MHz to 3.2 GHz

16

3.2 GHz to 10 GHz

14

10 GHz to 13.5 GHz

12

13.5 GHz to 16 GHz

12

16 GHz to 20 GHz

12

20 GHz to 24 GHz

11

24 GHz to 26.5 GHz

11

26.5 GHz to 35 GHz

7

35 GHz to 43.5 GHz

7

Uncorrected System Performance — Load Match, Options 201/21x/22x/401/41x/42x, All Ports (Specification, dB)

10 MHz to 50 MHz

10

50 MHz to 200 MHz

16

200 MHz to 500 MHz

16

500 MHz to 3.2 GHz

14

3.2 GHz to 10 GHz

13

10 GHz to 13.5 GHz

11

13.5 GHz to 16 GHz

11

16 GHz to 20 GHz

11

20 GHz to 24 GHz

10

24 GHz to 26.5 GHz

10

26.5 GHz to 43.5 GHz

7

> **Important:** Published specifications and characteristics apply over a 25 °C ±5 °C temperature range (unless otherwise stated) and 90 minutes after the instrument is powered on.

> **Important:** The Corrected System Performance with Cal Kits and Dynamic Accuracy Charts apply ONLY to N5244B/45B models with serial numbers starting with MY5244/45, SG5244/45, and US5244/45, and above.

> **Important:** Corrected (calibrated) measurements assume an N4697F flexible test port cable and a full 2-port calibration; the document provides calibration-kit specifications for the 85056A, 85056D, N4693A and N4693D kits and the N4693A 2-Port ECal module. These calibration kits and the test port cable are required to make corrected measurements and are not part of the analyzer's standard delivery — order the appropriate kit and cable separately.

> **Important:** With Option 425 (low frequency extension, N5245B only) and LFE enabled, measurements from 500 Hz to 100 MHz use LFE hardware; to measure below 10 MHz, LFE must be enabled. All measurements above 100 MHz use standard hardware regardless of the LFE enabled/disabled setting.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included with every used unit.
-   Functional verification included.
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Keysight
- **Type:** Net Ana
- **Tags:** product_manual_group_3

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 0.00 USD | In stock |

## Images

- Keysight N5244B 43.5 GHz PNA-X Network Analyzer (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/n5244b-keysight-network-analyzer-used)
> Updated: 2026-06-20