# Anritsu MS9740A 600 nm to 1750 nm Optical Spectrum Analyzer (Pre-Owned)

# Anritsu MS9740A 600 nm to 1750 nm Optical Spectrum Analyzer (Pre-Owned)

## Key Features At A Glance

-   Built-in Ethernet (TCP/IP) standard; GPIB optional for remote control and automated measurement systems
-   600 nm to 1750 nm wavelength measurement range
-   Spectrum measurement at 0.2 s / 5 nm with wavelength sweep time under 0.2 s
-   –90 dBm lowest optical sensitivity and 30 pm minimum wavelength resolution
-   ±20 pm wavelength accuracy (C/L band, using wavelength calibration light source)
-   Nine application modes: DFB-LD, FP-LD, LED, PMD, Opt. Amp, Opt. Amp Multi-channel, WDM, LD Module, WDM Filter
-   8.4-inch SVGA color LCD with embedded Windows OS and dedicated front-panel function keys
-   Under 15 kg and under 75 VA; supports SM and MM fiber (MM via MS9740A-009 option)

The MS9740A is an optical spectrum analyzer with a 600 nm to 1750 nm wavelength measurement range, built as an all-in-one unit for evaluating active optical devices. It is designed to characterize devices such as SFP, XFP, and SFP+ modules, optical transceivers, and VCSEL and DFB optical sources, presenting evaluation results — center wavelength, level, spectrum, SMSR, and OSNR — together on a single screen. The instrument was developed to reduce the total time from waveform sweeping through analysis to data transfer, cutting that cycle by 80% compared to previous models.

Across its measurement applications, the MS9740A supports LD module testing — measuring center wavelength, optical level, OSNR, SMSR, side-mode peak wavelength and level, and spectrum width by the n dB, RMS, and standard-deviation methods. It evaluates WDM signals across up to 300 channels, calculates EDFA gain and noise figure characteristics, and analyzes optical bandpass filters such as FBG, AWG, OBPF, WSS, and WDM filter devices. It also measures VCSEL spectra, and for optical chip and CAN device evaluation its high-speed sweeping and low connection loss support efficient measurement of multiple devices.

ValueTronics stocks and holds its own test-and-measurement inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Because the equipment is on hand rather than sourced on demand, pre-owned units are inspected and functionally verified in-house before they ship, while new units ship factory-sealed exactly as received. That combination lets engineers source the MS9740A with confidence in both availability and condition.

## Accessories Supplied

-   MS9740A Operation Manual (CD): 1 pc
-   Power Cord: 1 pc

## Product Core & Specifications

Specification

Value

Optical Input

Supported Optical Fiber

SM fiber (ITU-T G.652), 50 µm/125 µm GI fiber, PC Connector (reflection attenuation 40 dB or more)

Optical Connector

User replaceable: FC, SC, ST, DIN (All connectors are PC polished.)

Optical Return Loss

≥35 dB (Using SM fiber with wavelength of 1300 nm and 1550 nm)

Wavelength

Wavelength Measurement Range

600 nm to 1750 nm

Wavelength Accuracy

±20 pm (1520 nm to 1620 nm, Resolution: 0.03 nm to 0.2 nm), ±100 pm (1520 nm to 1620 nm, Resolution: 0.5 nm, 1.0 nm); ±300 pm (600 nm to 1520 nm), ±200 pm (1520 nm to 1570 nm), ±300 pm (1570 nm to 1750 nm)

Wavelength Stability

±5 pm (1 min, smoothing: 11 pt, at center wavelength of half maximum, Using SM fiber)

Wavelength Linearity

±20 pm (1520 nm to 1620 nm)

Setting Resolution

0.03, 0.05, 0.07, 0.1, 0.2, 0.5, 1.0 nm (0.03 nm, 0.05 nm only 1550 nm band and room temperature)

Resolution Accuracy

±7% (Resolution: 0.1 nm), ±3% (Resolution: 0.2 nm), ±2.2% (Resolution: 0.5 nm) \[1520 nm to 1620 nm\]; ±30% (Resolution: 0.1 nm), ±15% (Resolution: 0.2 nm), ±7% (Resolution: 0.5 nm) \[600 nm to 1520 nm, 1620 nm to 1750 nm\]

Measurement Range

5° to 30°C, Optical Att: Off

–65 to +10 dBm (600 nm to 1000 nm), –85 to +10 dBm (1000 nm to 1250 nm), –90 to +10 dBm (1250 nm to 1600 nm), –85 to +10 dBm (1600 nm to 1650 nm), –65 to +10 dBm (1650 nm to 1700 nm), –55 to +10 dBm (1700 nm to 1750 nm)

30° to 45°C, Optical Att: Off

–60 to +10 dBm (600 nm to 1000 nm), –80 to +10 dBm (1000 nm to 1250 nm), –85 to +10 dBm (1250 nm to 1600 nm), –80 to +10 dBm (1600 nm to 1650 nm), –60 to +10 dBm (1650 nm to 1700 nm), –50 to +10 dBm (1700 nm to 1750 nm)

5° to 30°C, Optical Att: On

–70 to +23 dBm (1100 nm to 1600 nm)

30° to 45°C, Optical Att: On

–65 to +23 dBm (1100 nm to 1600 nm)

Level

Level Accuracy

±0.4 dB (Wavelength: 1310 nm, 1550 nm, Input: –10 dBm, Resolution: 0.1 nm to 1.0 nm)

Level Stability

±0.02 dB (1 min, Wavelength: 1550 nm, Input: –23 dBm, Resolution: 0.1 nm to 1.0 nm, no polarization fluctuation)

Level Linearity

±0.05 dB (Wavelength: 1550 nm, Input: –50 to 0 dBm, Optical Att: Off); ±0.05 dB (Wavelength: 1550 nm, Input: –30 to +20 dBm, Optical Att: On)

Level Flatness

±0.1 dB (Wavelength: 1520 nm to 1620 nm, Resolution: 0.5 nm, Optical Att: Off)

Polarization Dependency

±0.05 dB (Wavelength: 1550 nm/1600 nm), ±0.1 dB (Wavelength: 1310 nm), \[Resolution: 0.5 nm, 1.0 nm\]

Dynamic Range

High dynamic range

70 dB (1 nm from peak wavelength), 60 dB (0.4 nm from peak wavelength), 42 dB (0.2 nm from peak wavelength)

Normal dynamic range

62 dB (1 nm from peak wavelength), 58 dB (0.4 nm from peak wavelength), 42 dB (0.2 nm from peak wavelength) \[Wavelength: 1550 nm, Resolution: 0.05 nm, Optical Att: Off, 20° to 30°C\]

Sweep

Sweep width

0.2 nm to 1200 nm, 0 nm

Sweep speed

≤0.2 s (span: 5 nm, Resolution: 0.1 nm), ≤0.3 s (span: 500 nm) \[VBW: 10 kHz, Normal dynamic range, center 1550 nm (span: 5 nm), 1200 nm (span: 500 nm), sweep start to stop, no optical input, sampling point: ≤501\]

Display

Display

800 × 600 dots, 8.4 inch SVGA color LCD

Function

Measurement functions

Auto Measure, Optical pulse measurement (External trigger), Power monitor

Display functions

Normalized, Max Hold, Min Hold, Overlap, Value in Air/Vacuum, Effective Resolution, Multi fiber mode

Analysis functions

Wavelength Subtraction, Marker, Wavelength Analysis (Threshold, ndB-Loss, Envelope, RMS, SMSR, Spectrum Power), Light Source Evaluation (FP-LD, DFB-LD, LED, LD Module), Optical AMP NF Evaluation, PMD Measurement, WDM Signal Evaluation, WDM Filter Analysis

Calibration functions

Auto Align, Wavelength cal., Level offset, Wavelength offset

Memory function

Display measurement data to memory A to J (10 waveforms)

Interfaces

Ethernet, GPIB (Option)

Input/Output function

I/O

Save and read files to USB memory

Input

External trigger terminal (0 to 0.8 V/2 V to 5 V, high impedance)

Output

Measured data text file output, measurement screen file (BMP, PNG) output, VGA output

General

Operating temperature

+5° to +45°C

Storage temperature

–20° to +60°C

Relative humidity

0 to 90% (no condensation)

Power Supply

100 V(ac) to 120 V(ac)/200 V(ac) to 240 V(ac), 50 Hz to 60 Hz, ≤75 VA

Dimensions

426 (W) × 177 (H) × 350 (D) mm (excluding projections)

Mass

≤15.0 kg (without options)

CE - EMC

2014/30/EU, EN61326-1, EN61000-3-2

CE - LVD

2014/35/EU, EN61010-1

RoHS

2011/65/EU, EN50581

Remote Control Interfaces

Ethernet, GPIB (Opt-001)

> **Important:** With the MS9740A-009 Multimode Fiber Interface option installed, some specifications differ from the standard MS9740A model.

> **Important:** When ordering the mainframe, the model name and one optical connector option must be specified (FC: MS9740A-037, ST: MS9740A-038, DIN: MS9740A-039, or SC: MS9740A-040). One free specified optical connector is provided for the optical input port.

> **Important:** A wavelength accuracy of ±20 pm (1520 nm to 1620 nm, without MS9740A-009) is assured only after wavelength calibration using the Light Source for Wavelength Calibration option (MS9740A-002) following automatic optical axis alignment. The MS9740A also supports wavelength calibration with an external light source such as a DFB-LD, but the MS9740A-002 option assures higher accuracy.

> **Important:** If the Windows OS option is not specified, the built-in OS is Windows Embedded Standard 2009 (WES2009); MS9740A-007 provides an OS upgrade to Windows Embedded Standard 7 (WES7).

> **Important:** When the Light Source for Wavelength Calibration option (MS9740A-002) is selected, one additional specified optical connector is supplied free.

> Usage tip: combine the MS9740A with the Anritsu BERTWave MP2100B to support spectrum analysis of optical transceiver outputs and WDM signals.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Anritsu
- **Type:** Spec An
- **Tags:** Analyzers, Anritsu, Manufacturers, Optical, product_manual_group_2, Product_used

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 0.00 USD | In stock |

## Images

- Anritsu MS9740A 600 nm to 1750 nm Optical Spectrum Analyzer (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/ms9740a-anritsu-optical-analyzer-used)
> Updated: 2026-06-27