# Anritsu MS4630B Network Analyzer (Pre-Owned)

# Anritsu MS4630B Network Analyzer (Pre-Owned)

## Key Features At A Glance

-   Network analyzer covering 10 Hz to 300 MHz with 0.01 Hz frequency resolution
-   120 dB dynamic range (RBW: 1 kHz) for out-of-band filter measurement
-   High-speed sweep of 150 µs per measurement point via synthesizer and DSP
-   Group delay measured at a resolution of 1/10,000 of the measurement range
-   Up to 10 independent markers per channel with simultaneous marker list display
-   Filter analysis: 3 dB bandwidth, center frequency, in-band ripple, out-of-band attenuation
-   Resonator analysis for resonance frequency, impedance, and equivalence constants
-   GPIB (IEEE 488.2) and PTA standard for automation; RS-232C/Centronics optional

The Anritsu MS4630B is a network analyzer that operates from 10 Hz to 300 MHz, built for high-speed, accurate evaluation of IF filters, resonators, and similar devices on electronics production and inspection lines. It combines a high-speed synthesizer with digital signal processing to deliver fast, repeatable device measurements suited to production-throughput demands.

Its measurement work centers on the applications it was designed for: evaluating IF filter resonance and group delay characteristics, and measuring the impedance characteristics of resonators used in AV equipment and personal computers. Crystal resonators can be tested by combining the analyzer with a π-circuit jig such as the MA1506A, and filter pass/fail screening is performed in real time using the single and segmented limit-test functions.

ValueTronics keeps the MS4630B and the wider test-and-measurement catalog in stock at our own 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where we hold and manage our inventory directly. Every used unit is inspected and functionally verified in-house before it ships, while new units leave the warehouse factory-sealed exactly as received.

## Accessories Supplied

-   Power cord, 2.6 m: 1 pc
-   F0013 Fuse, 5 A: 2 pcs
-   W1534AE MS4630B operation manual (main frame): 1 copy
-   W1535AE MS4630B operation manual (remote control): 1 copy

## Product Core & Specifications

Specification

Value

Measurement items

Transmission characteristics (ratio measurement)

Amplitude, phase, group delay

Reflection/impedance characteristics

Amplitude, phase (with external transducer)

Level characteristics

Absolute amplitude

Frequency

Range

10 Hz to 300 MHz

Resolution

0.01 Hz

Accuracy (standard): Aging rate

≤1 x 10–6/day (15 minutes after power-on)

Accuracy (standard): Temperature characteristics

≤±5 x 10–6 (0° to +50°C)

Accuracy (Option 13: High-stability reference oscillator): Aging rate

≤±2 x 10–8/day (24 h after power-on)

Accuracy (Option 13): Temperature characteristics

≤±5 x 10–8 (0° to +50°C)

Input

Channel No.

Standard: 2 (R, TA); Option 12: 3 (R, TA, TB)

Impedance

50 Ω, 1 MΩ switchable (when combined with MA4605A: 75 Ω, 1 MΩ)

Input range (IRG)

0/+20 dBm

Max. input power

AC: +20 dBm; DC ±2.2 V (50 Ω); AC: 0 dBm; DC: ±20 V (1 MΩ)

Connector

BNC-J

Probe source

+12 ±1 V, 100 mA (with protective circuit for shorts)

Average noise level

≤–120 dBm (RBW: 1 kHz, 1 to 300 MHz), ≤–110 dBm (RBW: 1 kHz, 80 kHz to 1 MHz)

Crosstalk (between channels)

≥120 dB (80 kHz to 300 MHz), ≥110 dB (up to 80 kHz)

Crosstalk (between transmitter and receiver)

≥125 dB

Resolution bandwidth

3, 10, 30, 100, 500 Hz, 1, 2, 3, 4, 5, 10, 20 kHz and automatic setting

Output

Output level range (Output A)

0 to +21 dBm; Option 10: –70 to +21 dBm

Output level range (Output B)

–6 to +15 dBm (–9.5 to +11.5 dB when Option 14 added); Option 10: –76 to +15 dBm (–79.5 to +11.5 dB when Option 14 added)

Output resolution

0.01 dB

Output level accuracy

≤±1.0 dB (frequency: 100 MHz, Output A: +10 dBm)

Output level linearity

≤±0.5 dB (0 dBm reference, frequency: 100 MHz, Output A: 0 to +21 dBm)

Output level deviation

≤±1.5 dB (output A: +10 dBm, 100 MHz reference)

Step error

±0.5 dB (Option 10)

Output impedance

50 Ω (when combined with MA4605A: 75 Ω)

Connector

BNC-J

Amplitude measurement

Measurement range

≥120 dB

Measurement resolution

0.001 dB

Display scale

0.01 dB/div to 50 dB/div (1-2-5 sequence)

Dynamic accuracy, Amplitude (80 kHz to 100 MHz / 10 kHz to 300 MHz)

0 to –10 dB

±0.20 dB / ±0.20 dB

–10 to –60 dB

±0.05 dB / ±0.05 dB

–60 to –70 dB

±0.10 dB / ±0.30 dB

–70 to –80 dB

±0.30 dB / ±1.00 dB

–80 to –90 dB

±1.20 dB / ±4.00 dB

–90 to –100 dB

±4.00 dB / –

Phase measurement

Measurement range

±180°

Measurement resolution

0.001°

Display scale

0.01° to 50°/div (1-2-5 sequence)

Dynamic accuracy, Phase (80 kHz to 100 MHz / 10 kHz to 300 MHz)

0 to –10 dB

±1.5° / ±1.5°

–10 to –60 dB

±0.3° / ±0.3°

–60 to –70 dB

±0.8° / ±2.0°

–70 to –80 dB

±2.0° / ±6.0°

–80 to –90 dB

±6.0° / ±20.0°

–90 to –100 dB

±20.0° / –

Group delay measurement

DRG

∆θ/(360 x ∆F)

Measurement resolution

2.78 x 10–5/∆F

Display scale

1 ps/div to 50 ms/div

Dynamic accuracy

Phase measurement accuracy/(360 x aperture frequency)

Calibration, correction

Calibration types

Frequency response, 1 port, 1 path-2 port, frequency response/isolation calibration, π-NET calibration

Calibration data interpolation

Measurement frequency; when number of measurement points changed, new calibration data interpolation calculation based on calibration data before change (except at log frequency measurement and 1001 measurement points)

Normalize

X–S

Electrical length calibration range

0 to ±999999.9999999 m, Resolution: 100 nm

Phase offset range

±180°

Sweeping

Frequency sweep

LIN (CENTER/SPAN, START/STOP), LOG (START/STOP)

Level sweep

LIN (START/STOP/STEP)

List sweep

Frequency, level, RBW, the individual setting in the waiting time

Number of measurement points

11, 21, 51, 101, 251, 501, 1001

Break point

Anywhere between 1 and 1001

Sweep time

150 µs/point, 38 ms/250 points full sweep (RBW: 20 kHz, normalize calibration, 1 trace)

Setting range

1 ms to 27.5 h

Sweep range

Full sweep, part sweep (between markers)

Sweep control

REPEAT/SINGLE, STOP/CONT

Sweep trigger

INT/EXT (RISE, FALL, LEVEL)

Display

Max. display screens

2 channels, 4 traces

Display format

LOG MAG (M), PHASE (P), DELAY (D), M/P, M/D, LIN MAG (LIN), LIN/P, LIN/D, REAL (R), IMAG (I), R/I, Z, Z/θ, Q, Z/Q, POLAR, VSWR, IMPD (Z∠θ, Rs + Ls/Cs, Q/D, R + jx), ADMT (Y∠θ, Rp + Lp/Cp, Q/D, G + jB)

Display

640 x 480 dots, 16.5 cm color LCD

Markers

Marker functions

NORMAL MKR, ∆MKR, 0 MKR, MKR →MAX, MKR →MIN, MKR →CF, ∆→SPAN, MKR →+PEAK, MKR →–PEAK, MKR TRACK + PEAK, MKR TRACK–PEAK, MKR CHANGE, MKR OFFSET

Setting

Set marker position to frequency or point

Multi-marker

Max. 10 markers for each trace

Measurement parameters

Filter function

F0, IL, passband (L, R), attenuation band (L, R), Ripple, Q, SF

Resonator function RESON 1

Fr, Fa, Zr, Za (0 PHASE), Fm, Fn, Zm, Zn (MAX/MIN)

Resonator function RESON 2

Fs, Fr, Fa, Zr, Za, Q, equivalence constant (R1, L1, C1, C0)

Averaging functions

Method: SUM, MAX, MIN; Count: 1 to 1000

Main trace (MT) memory

2 each (XMEM) for Channel 1 and Channel 2

Calibration S memory

2 each (SMEM) for Channel 1 and Channel 2

Image memory

2 each (IMEM) for Channel 1 and Channel 2

Sub-trace (ST)

MT →ST, MT = MT–ST, MT = ST

Limit line

Single or segment (10) limit line, pass/fail evaluation against limit line

Receive bandwidth and sweep time auto-setting

Receive bandwidth set automatically for set sweep time; automatically set to give minimum sweep time at set receive bandwidth

Function memory / Auxiliary media

Saving/recalling data

Measurement parameters, measured data, calibration data, PTA application programs saved/recalled to/from FD, PMC and Internet memory

FD

100 functions max.

> **Important:** Maximum input power: AC +20 dBm / DC ±2.2 V (50 Ω); AC 0 dBm / DC ±20 V (1 MΩ).

> **Important:** Reflection and impedance characteristic measurements require an external transducer (e.g., a reflection bridge or impedance probe), which is not supplied with the main frame and must be ordered separately (see Optional accessories).

> **Important:** Crystal resonators are tested by combining the MS4630B with a π-circuit jig such as the MA1506A; the floating admittance around the jig is eliminated using the MS4630B π-network calibration function and the jig calibration standard.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   ValueTronics warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Anritsu
- **Type:** Network Analyzer
- **Tags:** Analyzers, Anritsu, Manufacturers, Network, product_manual_group_1, Product_used, Updated Item Review

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 0.00 USD | In stock |
| NIST Traceable with Full Data | 0.00 USD | In stock |
| ISO IEC 17025 Accredited | 0.00 USD | In stock |

## Images

- Anritsu MS4630B Network Analyzer (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/ms4630b-anritsu-network-analyzer-used)
> Updated: 2026-06-27