## Key Features At A Glance

-   Modular portable data logger accepting plug-in and wireless units for voltage, temperature, humidity, resistance, and strain
-   LR8450 supports up to 4 plug-in units (120 ch); LR8450-01 adds up to 7 wireless units for up to 330 channels
-   Each unit incorporates its own A/D converter, keeping the maximum sampling rate high even as channels are added
-   Sampling down to 1 ms for voltage and strain; 10 ms for temperature, humidity, and resistance measurement
-   7-inch WVGA (800x480) TFT color LCD with simultaneous waveform and numerical-value display
-   LAN (Ethernet) with HTTP/FTP servers and FTP/NTP clients, USB host and function ports, and SD memory card slot
-   8-channel alarm output and 8-channel pulse measurement, plus two switchable 5/12/24 V sensor power outputs
-   3-year product warranty; built-in buffer memory retains measurement data through power or wireless interruptions

The Hioki LR8450 Memory HiLogger is a portable, modular multi-channel data logger built around your choice of plug-in and wireless measurement units. It is offered in two models: the Standard Model LR8450, designed for use with plug-in units only, and the Wireless LAN Model LR8450-01, which adds support for wireless units. A single logger can record voltage, temperature (thermocouple and RTD), humidity, resistance, and strain, gathering all of those signals into one synchronized time sequence.

The LR8450 is applied across a range of measurement tasks. It is used for voltage measurement of pressure-sensor and vibration-sensor outputs at up to a 1 ms sampling rate, for battery temperature-rise monitoring, automotive part temperature measurement, and road testing of automobiles. It is used to measure temperature near inverters and batteries, to test hydraulic equipment, and for strain measurement on pipes, aircraft wings, brakes, and the stress and load on moving parts. With wireless units, strain gages can be placed close to the measurement point so that the long, thin gage wires that are prone to breakage are kept short.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments we list are equipment we keep on hand. That combination lets engineers source a configured LR8450 logger with confidence in both its condition and its availability.

## Compare Other Models in This Series

The Memory HiLogger LR8450 family is offered in two models that share the same instrument platform, display, and measurement-unit ecosystem. The Standard Model LR8450 is designed for use with plug-in units only, while the Wireless LAN Model LR8450-01 adds the ability to connect wireless measurement units in addition to plug-in units.

Both models accept the same plug-in measurement units and the same SD/USB storage, drive the same 7-inch color display, and provide the same LAN, USB, pulse, alarm, and voltage-output interfaces. The choice between them is driven by whether wireless measurement units and wireless LAN connectivity are needed for the application.

Each model below is its own dedicated product page with condition-matched pricing. Select the new LR8450 or LR8450-01 configuration that matches your required channel count and connectivity, and review that page for its specific availability and price.

The two models differ in connectivity and maximum channel count. The Standard LR8450 connects up to four plug-in units for as many as 120 channels. The LR8450-01 adds support for up to seven wireless units, which can be mixed with plug-in units for a maximum of 330 channels, and it includes a wireless LAN interface (IEEE 802.11b/g/n) with access point and station modes that the Standard model does not provide.

Beyond connectivity, the LR8450-01 introduces wireless-specific behavior: each wireless unit carries its own buffer memory for data retention during communication dropouts, and the logger periodically corrects the sampling-timing shift between mixed wireless and plug-in units. See the comparison table that follows for the per-model channel maximums and interface differences.

Model

Channels

Max Sampling Rate

Measurement Target

**LR8450**

120

1 ms

—

LR8450-01

330

1 ms

—

U8550

15

10 ms

Voltage, thermocouples, humidity

U8551

15

10 ms

Voltage, thermocouples, humidity, RTD, resistance

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   Quick Start Manual
-   LOGGER Application Disc (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, Communication Instruction Manual)
-   USB Cable
-   AC Adapter Z1014

## Product Core & Specifications

Specification

Value

General / Basic Specifications

Product warranty period

3 years

Accuracy guarantee period

1 year

Maximum number of connectable modules

4 plug-in modules

Connectable plug-in modules

U8550 Voltage/Temp Unit, U8551 Universal Unit, U8552 Voltage/Temp Unit, U8553 High Speed Voltage Unit, U8554 Strain Unit

Internal buffer memory

Volatile memory, 256 Mwords

Clock functionality

Auto-calendar, automatic leap year recognition, 24-hour clock

Clock precision

±1.0 s/day (at 23°C)

Time axis accuracy

±0.2 s/day (at 23°C)

Backup battery service life

At least 10 years for clock (reference value at 23°C)

Operating environment

Indoors, Pollution Degree 2, altitude up to 2000 m

Operating temperature and humidity range

−10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing); charging temperature range 5°C to 35°C

Storage temperature and humidity range

−20°C to 60°C (−4°F to 140°F), 80% RH or less (non-condensing)

Dimensions (without modules)

272W × 145H × 43D mm (10.72″W × 5.71″H × 1.69″D) (excluding protrusions)

Dimensions (with 2 modules)

272W × 198H × 63D mm (10.71″W × 7.8″H × 2.78″D) (excluding protrusions)

Dimensions (with 4 modules)

272W × 252H × 63D mm (10.71″W × 9.92″H × 2.48″D) (excluding protruding parts)

Mass

Approx. 1108 g (39.08 oz.) (excluding battery pack)

Standards

Safety: EN61010; EMC: EN61326 Class A

Vibration resistance

JIS D 1601:1995 5.3 (1) Class 1: Passenger vehicles; conditions: Class A equivalent

Display

Display

7-inch TFT color LCD (WVGA 800 × 480 dots)

Display resolution (waveform display)

Max. 20 divisions (horizontal axis) × 10 divisions (vertical axis)

Display language

Japanese, English, Chinese, Korean

Backlight service life

Approx. 100,000 h (reference value at 23°C)

Backlight brightness

5 levels (user-selectable)

Waveform colors

24 colors

Power Supply

AC adapter

Z1014 AC Adapter (12 V DC ±10%); rated supply voltage 100 V to 240 V AC; rated power supply frequency 50 Hz/60 Hz

Battery

Z1007 Battery Pack (Li-ion, 7.2 V, 2170 mAh); accommodates 2 batteries (AC adapter has priority)

External power supply

10 V to 30 V DC

Normal power consumption

LCD at maximum brightness: 8.5 VA; LCD backlight off: 7 VA (instrument only)

Maximum rated power (AC adapter)

95 VA (including AC Adapter)

Maximum rated power (30 V DC external)

28 VA (while charging battery with LCD at maximum brightness)

Maximum rated power (Z1007 battery)

20 VA (with LCD at maximum brightness)

Continuous operating time (battery)

One Z1007: approx. 2 h; two Z1007: approx. 4 h (reference value at 23°C)

Charging time

Approx. 7 h (reference value at 23°C)

Interface Specifications

LAN interface

IEEE 802.3 Ethernet, automatic 100Base-TX/1000Base-T detection, Auto MDI-X, DHCP, DNS support; Connector RJ-45; maximum cable length 100 m

USB interface (host)

USB 2.0 compliant; Series A receptacle × 2; FAT16/FAT32; connectable devices: keyboard, mouse, hub (1 layer), USB drive (1 port)

USB interface (function)

USB 2.0 compliant; Series mini-B receptacle

SD card slot

SD standard-compliant slot × 1 (SD/SDHC memory card support); FAT16/FAT32

Network server functions

HTTP server, FTP server, FTP client, NTP client, e-mail transmission

External Control Terminals

External I/O input

4 terminals, non-isolated (same GND as instrument); input voltage 0 V to 10 V DC; slope rising/falling (user-selectable)

External I/O output

Open-drain output (with 5 V voltage output); maximum switching capacity 5 V to 10 V DC, 200 mA

Alarm output

8 terminals, non-isolated; open-drain output (with 5 V voltage output); maximum switching capacity 5 V to 30 V DC, 200 mA

Voltage output

2 terminals, non-isolated; Off, 5 V, 12 V, 24 V (user-selectable; 24 V on VOUTPUT1 terminal only); supply current max. 100 mA each

GND terminal

10 terminals (common GND)

Recording

Recording mode

Normal

Recording intervals

1 ms, 2 ms, 5 ms, 10 ms, 20 ms, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s, 30 s, 1 min., 2 min., 5 min., 10 min., 20 min., 30 min., 1 h

Waveform recording

Last 256 M data points saved in internal buffer memory

Backup of recorded data

None

Triggers

Trigger method

Digital comparison method

Trigger timing

Start, stop, or start & stop

Trigger sources

Analog, pulse, logic, waveform calculations

Trigger level resolution (analog)

0.1% f.s. (f.s. = 10 divisions)

Alarms

Alarm channels

Set separately for ALM1 to ALM8

Alarm sources

Analog, pulse, logic, waveform calculations

Alarm filter

Off, 2 to 1000 samples

Pulse / Logic Input

Number of channels

8 channels (common GND, non-isolated)

Adaptive input format

Non-voltage contact, open collector (PNP open collector requires external resistor), or voltage input

Maximum input voltage

0 V to 42 V DC

Input resistance

1.1 MΩ ±5%

Pulse count range

1000 M pulse f.s., 1 pulse resolution, 0 to 1000 M pulse

Rotational speed range

5000/n (r/s) f.s.; 300,000/n (r/min.) f.s. (n = pulses per rotation, 1 to 1000)

Calculations

Numerical calculations

Up to 10 simultaneously: average, peak-to-peak, max, max time, min, min time, integration, aggregation, usage ratio, on time, off time, on count, off count

Waveform calculations

Four arithmetic operations among channels; moving average, simple average, aggregation, integration; channels W1–W30

> **Important:** The LR8450 and LR8450-01 cannot perform measurement on their own; one or more plug-in units or wireless units are required (sold separately).

> **Important:** The LR8450-01 and each wireless unit emit radio waves. Use of radio waves is subject to licensing requirements in certain countries. Using it in a country or region other than those indicated may violate the law and may result in legal penalties for the operator. For the latest information about supported countries and regions, please visit the Hioki website.

> **Important:** Always use HIOKI optional storage media. Proper operation is not guaranteed when using storage media from other manufacturers, and may prevent the product from saving and loading data properly.

> **Important:** Even in good wireless communication conditions (low interference), the sampling-timing between wireless devices may shift about 20 ms; in bad wireless conditions the shift will be much worse.

> **Important:** The wireless unit buffer memory holds up to 5 min. of measurement data during a communications interruption; however, data collected using the Logger Utility software measurement cannot be restored in this manner.

> Usage tip: pair the logger with HIOKI optional storage media (SD memory cards Z4001 or Z4003, or USB drive Z4006), as guaranteed save/load operation is specified with HIOKI media.

> **Important:** Channels are isolated from each other with semiconductor relays. Never allow a voltage exceeding the product specifications (for example a lightning surge) to be applied across channels, as doing so may cause the semiconductor relays to short.

> **Important:** Z3230 Wireless LAN Adapter: the LR8450/LR8450-01 instrument takes two adapters; each wireless unit takes one.

> Recommended pairing: humidity measurement uses the HIOKI Z2000 Humidity Sensor together with the U8550, U8551, U8552, or LR8531 units.

## About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 3094.0 USD
- **Vendor:** Hioki
- **Type:** Data Log
- **Tags:** Data Logger, Hioki, Manufacturers, Meters & DAQ, product_manual_group_3, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 3094.00 USD | In stock |

## Images

- LR8450-01 Hioki Data Logger

---

> Source: [ValueTronics](https://valuetronics.com/products/lr8450-01-hioki-data-logger-new)
> Updated: 2026-06-20