# Teledyne LeCroy HVD3220 2 kV 400 MHz High Voltage Differential Probe

# Teledyne LeCroy HVD3220 2 kV 400 MHz High Voltage Differential Probe

## Key Features At A Glance

-   1 kV, 2 kV, and 6 kV CAT-rated models spanning 120/240 V supplies through 5 kV-class electrical apparatus
-   Exceptional common-mode rejection ratio (CMRR) across a broad frequency range for noisy power-electronics environments
-   1% gain accuracy (LF, guaranteed) for precise high voltage floating measurements
-   High offset capability at both high and low attenuation, with AC and DC output coupling
-   ProBus active probe interface supplies power and communication and auto-selects attenuation by V/div setting
-   AutoZero with auto-disconnect switch calibrates out small offset drifts without removing leads from the DUT
-   Bandwidths from 25 MHz to 400 MHz across the series with wide oscilloscope compatibility

The HVD3000A series is a family of high voltage differential probes engineered to deliver high common-mode rejection ratio (CMRR) over a broad frequency range, simplifying the measurement challenges found in noisy, high common-mode power electronics environments. The probe design is easy to use and enables safe, precise high voltage floating measurements.

The series is built to cover the fullest range of power-electronics measurement tasks: 120 V and 240 V switch-mode power supplies and half-bridge circuit topologies, 600 V-class three-phase electrical apparatus, 5 kV-class electrical apparatus, single-phase and three-phase solar PV inverters including newer 1500 Vdc string inverters per IEC/EN 61010-031:2015, high-power DC-DC converters operating at 500 Vdc or higher, and upper-side MOSFET/IGBT gate-drive measurements. Multiple probes can be used together to understand complex device switching performance.

ValueTronics stocks and holds its own test-and-measurement inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Holding inventory directly lets us confirm condition and move quickly on orders.

## Brand Heritage

LeCroy Corporation, founded in 1964, was acquired by Teledyne Technologies in 2012 and has since operated as Teledyne LeCroy. The probes in this series carry the Teledyne LeCroy brand.

## Compare Other Models in This Series

The HVD3000A series brings together high voltage differential probes that share a common design — high CMRR over a broad frequency range, 1% gain accuracy, high offset capability, AutoZero, and the ProBus active probe interface — while differing in safety rating, bandwidth, and differential voltage range. The family is organized to cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V-class and 5 kV-class electrical apparatus.

Within the family, the HVD310xA models serve 1 kV-rated 600 V-class measurements, the HVD3206A and HVD3220 add a 2 kV safety rating with 1500 Vdc CAT III solar PV capability, and the HVD3605A extends coverage to 5 kV-class apparatus at a 6 kV rating. Each model is specified to provide the best available gain accuracy, widest differential and offset voltage range, and strong CMRR within its rating class.

Each new model in the series listed below is its own dedicated product page with condition-matched pricing. Select the specific model and safety rating that matches your application to see its current new availability and price.

The models differ primarily in three dimensions shown in the comparison table that follows: safety rating (1 kV for the HVD310xA models, 2 kV for the HVD3206A and HVD3220, and 6 kV for the HVD3605A), bandwidth (from 25 MHz on the HVD3102A up to 400 MHz on the HVD3220), and differential voltage range at high attenuation (from 1500 V on the HVD3102A/HVD3106A up to 7000 V DC + peak AC on the HVD3605A).

Cable length is a further differentiator: standard models ship with a 2 meter cable, while the -6M variants (HVD3106A-6M, HVD3206A-6M) and the HVD3605A use a 6 meter cable. The HVD3220 offers four switchable attenuation ratios (50x/100x/250x/500x) and the tightest guaranteed gain accuracy in the family at 0.35%–0.7%. Consult the comparison table for the exact bandwidth, rise time, voltage range, and attenuation of each model.

Model

Safety Rating

Bandwidth

Max Differential Range

**HVD3220**

2 kV

400 MHz

2000 V

HVD3102A

1 kV

25 MHz

1500 V

HVD3106A

1 kV

120 MHz

1500 V

HVD3106A-6M

1 kV

80 MHz

1500 V

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Product Core & Specifications

Specification

Value

Bandwidth

400 MHz

Rise Time (10-90)

875 ps

Differential Voltage Range (High Attenuation)

2000 V (DC + peak AC) from 35 to 500 V/div with up to 1500V offset. 1000 V (DC + peak AC) from 14 to 34.5 V/div with up to 750V offset.

Differential Voltage Range (Low Attenuation)

400 V (DC + peak AC) from 7 V/div to 13.8 V/div with up to 300V offset. 200 V (DC + peak AC) from 500 mV/div to 6.9 V/div with up to 150V offset.

Common Mode Voltage Range

±2000 V (DC + peak AC)

Maximum Input Voltage to Earth

±2000 Vpk (nominal, either input to ground)

Max Safe Input Voltage

2000 V (DC + peak AC) CAT I \*; 1500 Vdc CAT III; 1000 Vrms CAT III

Sensitivity

500 mV/div to 6.9V/div (50X); 7 V/div to 13.8V/div (100X); 14 V/div to 34.5V/div (250X); 35 V/div to 500V/div (500X)

Gain Accuracy

0.35% - 0.7% (LF, guaranteed)

Slew Rate

1300 V/ns (typical)

Attenuation

50x / 100x / 250x / 500x

Input Impedance

10 MΩ || 2 pF (between inputs); 5 MΩ || 4 pF (either input to ground)

Input Coupling

DC only

Output Coupling

DC only

Output Termination

50Ω

Interface

ProBus

Input Lead Length

27 cm

Cable Length (input lead to oscilloscope connection)

2.25 m

Noise and Rejection

CMRR (Typical)

DC - 60 Hz: 85 dB; 1 MHz: 65 dB; 5 MHz: 55 dB; 20 MHz: 50 dB; 100 MHz: 45 dB; 300 MHz: 30 dB

Noise (Probe)

50X: 180 mVrms; 100X: 180 mVrms; 250X: 280 mVrms; 500X: 300 mVrms (referred to input)

Environmental

Temperature (Operating)

0°C to 50°C

Temperature (Non-Operating)

\-40°C to 70°C

Humidity (Operating)

5% to 80% RH (Non-Condensing) up to 30°C, decreasing linearly to 45% RH at 50°C

Humidity (Non-Operating)

5% to 95% RH (Non-Condensing), 75% RH above 30°C, 45% RH above 40°C

Altitude (Operating)

3000 m maximum. When used with clip accessories, 2000 m maximum

Altitude (Non-Operating)

10,000 m

Pollution Degree

2, Indoor use only

Certifications

CE

LVD Directive 2006/95/EC; EMC Directive 2004/108/EC; IEC/EN 61010-031:2015; IEC/EN 61326-1:2013

UL Listed

–

cUL Listed

–

> **Important:** CAT I ratings marked with an asterisk in the specifications are per IEC/EN 61010-031/A1:2008; no rated measurement category applies per IEC/EN 61010-031:2015.

> **Important:** The HVD3220 and HVD3206A support 1500 Vdc solar photovoltaic (PV) measurements per the IEC/EN 61010-031:2015 standard, with a 1500 Vdc CAT III and a 2000 V (DC + peak AC) CAT I rating.

> **Important:** "No Accessory (NOACC)" probe versions (HVD3102A-NOACC, HVD3106A-NOACC) ship without tip accessories; use your existing accessories or purchase just the ones you want.

> **Important:** The ProBus interface provides power and communication to the probe, eliminating the need for a separate power supply or batteries; attenuation is automatically selected based on the oscilloscope gain range (V/div) setting.

> **Important:** Operating altitude is 3000 m maximum, reduced to 2000 m maximum when used with clip accessories.

> Recommended pairing: the PK-HV-001 High Voltage Replacement Accessories Kit supplies replacement 4 mm tip adapters, safety alligator clips, and plunger clips (two each) for these probes.

## About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 7280.0 USD
- **Vendor:** Teledyne LeCroy
- **Type:** Diff Probe
- **Tags:** Differential, Manufacturers, Other Equipment, Probe, product_manual_group_3, Product_new, Teledyne LeCroy

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 7280.00 USD | In stock |

## Images

- HVD3220 Teledyne LeCroy Differential Probe

---

> Source: [ValueTronics](https://valuetronics.com/products/hvd3220-teledyne-lecroy-differential-probe-new)
> Updated: 2026-06-20