# HT Italia HT97U AC Current Transducer Clamp, 10/100/1000 A

# HT Italia HT97U AC Current Transducer Clamp, 10/100/1000 A

## Key Features At A Glance

-   CAT III 600V overvoltage category; pollution degree 2 per IEC 1010-1
-   Three selectable AC current ranges: 10A, 100A, and 1000A
-   1V AC output with selectable ratios of 100mV/A, 10mV/A, and 1mV/A
-   Frequency range of 40Hz to 10kHz
-   Maximum error of 2% of reading
-   Cable opening diameter of 54mm; accepts 35x35mm or 50x12mm bus bars
-   Operating temperature range of -10 to +50 deg C
-   2m output cable terminated with a Hypertac connector

The HT Italia HT97U is an AC current transducer clamp that converts measured alternating current into a proportional 1V AC output signal. It offers three selectable full-scale ranges — 10A, 100A, and 1000A AC — each with its own conversion ratio of 100mV/A, 10mV/A, or 1mV/A respectively. The clamp jaw provides an opening of 54mm diameter for round conductors and accommodates bus bars sized 35x35mm or 50x12mm.

A current transducer clamp lets a measurement system sense AC current without breaking the circuit, clamping around a conductor and producing a scaled low-level signal that downstream instrumentation can read. On the HT97U, this scaled output is intended for power measurement work, where the conventional current direction P1 to P2 indicated by the arrow on the rear of the clamp must be observed.

ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive, Elgin, Illinois.

## Product Core & Specifications

Specification

Value

Specifications

Selectable ranges

10A / 100A / 1000A AC

Measuring range

0,1 ÷ 10A / 0.5A ÷ 100A / 1A ÷ 1000A AC

Output signal

1V AC

Protection

By diodes

Ratio

100mV/A – 10mV/A - 1mV/A

Accuracy

see table

Max error

2% (of reading)

Internal load

10A=100Ω; 100A=10Ω; 1000A=1Ω

External min load

100 times the internal load

Power measurement

Take care to the conventional direction P1 ⇒ P2 rear of the arrow

Frequency range

40Hz to 10kHz

Pollution degree

2 according to IEC 1010-1

Dielectric strength

5,5 KV 50 Hz 1 min

Temperature range

\-10 ÷ +50 °C

Overvoltage category

CAT III 600V

“Opening” cable

Diameter 54 mm

"Opening" bus bars

35x35mm or 50x12mm

Dimensions (mm)

105 x 225 x 31 mm

Weight

720 g

Output connection

Cable 2m with Hypertac connector

Accuracy — 10A FS

Precision in % rdg of output signal (0.1 ÷ 0.5)

±(2%rdg + 4mV)

Precision in % rdg of output signal (0.5 ÷ 2.0)

±(2%rdg + 4mV)

Precision in % rdg of output signal (2.0 ÷ 10)

±(0.5%rdg + 4mV)

Phase difference (0.1 ÷ 0.5)

Not specified

Phase difference (0.5 ÷ 2.0)

10 degrees

Phase difference (2.0 ÷ 10)

5 degrees

Accuracy — 100A FS

Precision in % rdg of output signal (0.5 ÷ 1.0)

±(2%rdg + 3mV)

Precision in % rdg of output signal (1.0 ÷ 20)

±(1%rdg + 2mV)

Precision in % rdg of output signal (20 ÷ 100)

±(1%rdg + 2mV)

Phase difference (0.5 ÷ 1.0)

2 degrees

Phase difference (1.0 ÷ 20)

1 degree

Phase difference (20 ÷ 100)

1 degree

Accuracy — 1000A FS

Precision in % rdg of output signal (1.0 ÷ 10)

±(1%lettura + 1mV)

Precision in % rdg of output signal (10 ÷ 200)

±(1%lettura + 1mV)

Precision in % rdg of output signal (200 ÷ 1000)

±(1%lettura + 1mV)

Phase difference (1.0 ÷ 10)

1 degree

Phase difference (10 ÷ 200)

1 degree

Phase difference (200 ÷ 1000)

0.5 degrees

> **Important:** For power measurement, observe the conventional current direction P1 to P2 indicated by the arrow on the rear of the clamp.

> **Important:** External minimum load must be 100 times the internal load (Internal load: 10A=100Ω; 100A=10Ω; 1000A=1Ω).

## About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 495.0 USD
- **Vendor:** HT Italia
- **Type:** Curr Probe
- **Tags:** Current Clamp, HT Instruments, Manufacturers, Other Equipment, product_manual_group_3, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 495.00 USD | In stock |

## Images

- HT Italia HT97U AC Current Transducer Clamp, 10/100/1000 A

---

> Source: [ValueTronics](https://valuetronics.com/products/ht97u-ht-instruments-current-clamp-new)
> Updated: 2026-06-20