# Rohde & Schwarz FSP40 9 kHz to 40 GHz Spectrum Analyzer (Pre-Owned)

# Rohde & Schwarz FSP40 9 kHz to 40 GHz Spectrum Analyzer (Pre-Owned)

## Key Features At A Glance

-   Five frequency tiers from 9 kHz to 40 GHz across the FSP series (FSP3, FSP7, FSP13, FSP30, FSP40)
-   Resolution bandwidths from 10 Hz to 10 MHz in 1/3 steps, plus FFT filters from 1 Hz to 30 kHz
-   EMI bandwidths of 200 Hz, 9 kHz, and 120 kHz (–6 dB)
-   IEC/IEEE-488 (IEEE 488.2) and RS-232-C interfaces standard with SCPI 1997.0 command set for ATE
-   Seven trace detectors: max peak, min peak, auto peak, sample, quasi-peak, average, and RMS
-   21 cm (8.4") TFT colour VGA display showing up to two independent diagrams
-   Optional tracking generator, OCXO reference, and integrated preamplifier (separately ordered)

The Rohde & Schwarz FSP is a family of spectrum analyzers offered in five frequency tiers — FSP3, FSP7, FSP13, FSP30, and FSP40 — each beginning at 9 kHz and extending to an upper limit of 3, 7, 13.6, 30, or 40 GHz respectively. Frequency resolution reaches 0.01 Hz, and frequencies are read out using a marker or an integrated frequency counter with selectable resolution from 0.1 Hz to 10 kHz.

Beyond general spectrum measurements, the FSP platform hosts a broad set of optional application firmware packages for specific signal standards, including GSM/EDGE, 3GPP WCDMA and TD-SCDMA, CDMA2000, Bluetooth, WLAN 802.11a, and WiBro/WiMAX (IEEE 802.16 OFDMA), as well as dedicated phase-noise and noise-figure measurement firmware. Each of these is a separately ordered software option rather than a base-unit feature.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit is inspected and functionally verified in-house before it ships, while new units leave the warehouse factory-sealed exactly as received.

## Brand Heritage

Rohde & Schwarz is a privately held German electronics company that has operated under its founders' names since its establishment, with no major corporate rebranding or acquisition changing its identity.

## Compare Other Models in This Series

The R&S FSP series comprises five spectrum analyzers that share a common architecture and differ principally in their upper frequency limit. All five models — FSP3, FSP7, FSP13, FSP30, and FSP40 — start at 9 kHz, with maximum frequencies of 3, 7, 13.6, 30, and 40 GHz respectively.

Across the series the instruments share the same resolution-bandwidth range, detector set, display, and remote-control interfaces, so the choice between models is driven primarily by the frequency coverage and RF connector system a given measurement requires.

Each pre-owned model below is its own dedicated product page with condition-matched pricing. Select the FSP model whose frequency coverage and option compatibility match your application, then choose the pre-owned listing that fits your requirements and budget.

The models differ in upper frequency limit (3 GHz to 40 GHz), RF input connector system, and input VSWR — 1.5:1 below 3 GHz rising to 3.0:1 on the higher-frequency models — as shown in the comparison table. Typical weight also ranges from 10.5 kg to 12 kg across the series.

Option availability is model-dependent: the electronic attenuator with integrated preamplifier (FSP-B25) is offered only for the FSP3 and FSP7, while the LO/IF ports for external mixers (FSP-B21) are available only on the FSP40. Consult each model's row in the comparison table for its specific frequency range and supported options.

Model

Frequency Range

RF Input

VSWR

**FSP40**

9 kHz to 40 GHz

Test port system 50 Ω, N female, K female

3.0:1 (f <40 GHz)

FSP3

9 kHz to 3 GHz

N female, 50 Ω

1.5:1 (f <3 GHz)

FSP7

9 kHz to 7 GHz

N female, 50 Ω

2.0:1 (f <7 GHz)

FSP13

9 kHz to 13.6 GHz

N female, 50 Ω

2.5:1 (f <13 GHz)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   Power cable
-   Compact manual
-   CD-ROM with operating manual and service manual
-   Test port adapter with K female (1036.4790.00) and N female (1036.4777.00) connector

## Product Core & Specifications

Specification

Value

Frequency

Frequency range

9 kHz to 40 GHz

Frequency span

0 Hz, 10 Hz to 40 GHz

Typical SSB Phase Noise vs Offset (dBc (1 Hz))

fin = 3 GHz, 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz

−74 / −100 / −108 / −108 / −118 dBc

fin = 7 GHz, 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz

−67 / −94 / −104 / −106 / −118 dBc

fin = 13 GHz, 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz

−61 / −88 / −98 / −100 / −112 dBc

fin = 22 GHz, 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz

−57 / −84 / −94 / −96 / −108 dBc

fin = 26 GHz, 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz

−55 / −82 / −92 / −94 / −106 dBc

fin = 40 GHz, 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz

−52 / −79 / −91 / −92 / −102 dBc

Maximum Input Level

DC voltage (RF attenuation 0 dB)

0 V

CW RF power (RF attenuation 0 dB)

20 dBm

Pulse spectral density (RF attenuation 0 dB)

97 dBμV (1 MHz)

CW RF power (RF attenuation ≥10 dB)

30 dBm

Max. pulse voltage (RF attenuation ≥10 dB)

50 V

Max. pulse energy, 10 μs (RF attenuation ≥10 dB)

0.5 mWs

1 dB compression of input mixer (0 dB RF attenuation, f >200 MHz)

0 dBm nominal

3rd-Order Intermodulation (level 2 × −30 dBm, ∆f >5 × RBW or 10 kHz)

20 MHz to 200 MHz

\>70 dBc, TOI >5 dBm

200 MHz to 3 GHz

\>74 dBc, TOI >7 dBm (typ. 10 dBm)

3 GHz to 7 GHz

\>80 dBc, TOI >10 dBm (typ. 15 dBm)

7 GHz to 13.6 GHz

\>80 dBc, TOI >10 dBm

13.6 GHz to 30 GHz

\>80 dBc, TOI >10 dBm

30 GHz to 40 GHz

\>80 dBc, TOI >10 dBm

Second Harmonic Intercept Point (SHI)

<100 MHz

typ. 25 dBm

100 MHz to 1.5 GHz

typ. 35 dBm

1.5 GHz to 7 GHz

typ. 80 dBm

7 GHz to 13.6 GHz

typ. 80 dBm

13.6 GHz to 30 GHz

typ. 80 dBm

30 GHz to 40 GHz

typ. 80 dBm

Displayed Average Noise Level (0 dB RF att, RBW 10 Hz, VBW 1 Hz, 20 averages, trace average, span 0 Hz, 50 Ω)

9 kHz

<−95 dBm

100 kHz

<−100 dBm

1 MHz

<−120 dBm, typ. −125 dBm

10 MHz to 1 GHz

<−140 dBm, typ. −145 dBm

1 GHz to 3 GHz

<−138 dBm, typ. −143 dBm

3 GHz to 7 GHz

<−135 dBm, typ. −140 dBm

7 GHz to 13.6 GHz

<−132 dBm, typ. −138 dBm

13.6 GHz to 20 GHz

<−120 dBm, typ. −128 dBm

20 GHz to 30 GHz

<−120 dBm, typ. −128 dBm

30 GHz to 40 GHz

<−112 dBm, typ. −120 dBm

Frequency Response

<50 kHz

<+0.5/−1.0 dB

50 kHz to 3 GHz

<0.5 dB (σ = 0.17 dB)

3 GHz to 7 GHz

<2 dB (σ = 0.7 dB)

7 GHz to 13.6 GHz

<2.5 dB (RF attenuation 10 dB, sweep time >1 s/1 GHz)

13.6 GHz to 30 GHz

<3 dB (RF attenuation 10 dB, sweep time >1 s/1 GHz)

30 GHz to 40 GHz

<4 dB (RF attenuation 10 dB, sweep time >1 s/1 GHz)

RF Input

RF input connector

Test port system 50 Ω, N female, K female

VSWR (RF attenuation >0 dB), f <40 GHz

3.0:1

General

Typical power consumption

150 VA

Weight

12 kg

> **Important:** Maximum input level: +30 dBm CW RF power with RF attenuation ≥10 dB, and 50 V DC at the RF input.

> **Important:** Specifications are valid under the following conditions: 15 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to, and total calibration performed.

> **Important:** Data without tolerances are typical values only. Data designated "nominal" applies to design parameters and is not tested. Data designated "σ = xx dB" is shown as standard deviation.

> **Important:** Recommended calibration interval: 2 years for operation with external reference, 1 year with internal reference.

> **Important:** Maximum permissible DC input voltage at the RF input is 50 V for the ¸FSP3/¸FSP7/¸FSP13 and 0 V for the microwave-input ¸FSP30/¸FSP40; with option ¸FSP-B29 (frequency range extension 20 Hz) the maximum DC input voltage is 0 V.

> **Important:** The ¸FSP30 and ¸FSP40 are supplied with test port adapters; alternate connectors (e.g. 3.5 mm male, N male, K male, 2.4 mm female) are available as recommended extras (see "Recommended extras for alternate connectors").

> Usage tip: for portable or field operation, pair the FSP with the R&S FSP-B30 DC Power Supply and the FSP-B31/-B32 Battery Pack listed in the ordering information.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   Warranty included
-   Functional verification included
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD
- **Vendor:** Rohde & Schwarz
- **Type:** Spec An
- **Tags:** Analyzers, Manufacturers, product_manual_group_1, Product_used, Rohde & Schwarz, Spectrum

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 0.00 USD | In stock |
| NIST Traceable with Full Data | 0.00 USD | In stock |
| ISO IEC 17025 Accredited | 0.00 USD | In stock |

## Images

- Rohde & Schwarz FSP40 9 kHz to 40 GHz Spectrum Analyzer (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/fsp40-rohde-schwarz-spectrum-analyzer-used)
> Updated: 2026-07-06