# Agilent E4430A Digital RF Signal Generator (Pre-Owned)

# Agilent E4430A Digital RF Signal Generator (Pre-Owned)

## Key Features At A Glance

-   Frequency range 250 kHz to 1000 MHz with 0.01 Hz frequency resolution
-   Output level from +13 to -136 dBm with 0.02 dB level resolution
-   Built-in vector (I/Q) modulation plus 50 ohm external I/Q inputs (0.5 Vrms full scale)
-   Internal AM, FM, phase, and pulse modulation from a sine/square/ramp/triangle/pulse/noise source
-   Optional I/Q baseband generator (Opt UN3/UN4): DECT, GSM, NADC, PDC, PHS, and TETRA formats
-   SSB phase noise <-120 dBc/Hz at 500 MHz, 20 kHz offset (typical)
-   Step and list sweep of frequency and power, 2 to 401 points, 2 ms to 60 s dwell
-   Optional high-stability timebase (Opt 1E5): <±0.1 ppm/yr aging rate

The Agilent E4430A — also designated the ESG-D1000A — is a digital RF signal generator that delivers a synthesized carrier from 250 kHz to 1000 MHz. It combines a frequency synthesizer, a calibrated output attenuator, and built-in analog and vector (I/Q) modulation, making it a single-box source for generating both unmodulated CW signals and complex digitally modulated waveforms.

With the optional internal I/Q baseband generator installed, the E4430A generates framed, digitally modulated signals conforming to the DECT, GSM (including DCS1800 and PCS1900), NADC, PDC, PHS, and TETRA standards. Frames and timeslots can be configured as different traffic or control channel types, and the data field of a timeslot accepts a user file, a PRBS pattern (PN9 or PN15), or external serial data supplied with the appropriate clock.

ValueTronics stocks and holds its own test and measurement inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned instrument is inspected and functionally verified in-house before it ships, while new units leave the warehouse factory-sealed exactly as received — so buyers receive equipment that has been sourced, stocked, and handled directly by our own team.

## Brand Heritage

Hewlett-Packard's test and measurement business was spun off as Agilent Technologies in 1999. That test and measurement operation was subsequently established as Keysight Technologies in 2014, the company that carries the lineage of these instruments today.

## Product Core & Specifications

Specification

Value

Frequency

Frequency Range (ESG-D1000A)

250 kHz to 1000 MHz

Resolution

0.01 Hz

Switching Speed (Modulation On)

<45 ms, typical

Switching Speed (Modulation Off)

<35 ms, typical

Accuracy

Same as timebase

Sweep Modes

Operating modes

Step: frequency & power, and arbitrary list

Dwell Time

2 ms to 60 sec

Number of Points

2 to 401

Internal Reference Oscillator

Aging Rate (Standard, typical)

<±2 ppm/yr

Aging Rate (High Stability, Opt 1E5)

<±0.1 ppm/yr or <±0.0005 ppm/day after 45 days

Temperature (Standard)

<±1 ppm

Temperature (High Stability, Opt 1E5)

<±0.05 ppm, typical (0° to 55° C)

Line Voltage (Standard)

<±0.1 ppm (+5%, -10%)

Line Voltage (High Stability, Opt 1E5)

<±0.002 ppm, typical (+5%, -10%)

Timebase Reference Output

Frequency

10 MHz

Amplitude

\>0.35 Vrms into 50 ohm load

External Reference Input

Frequency

1, 2, 5, 10 MHz ± typ. 10 ppm (Option 1E5: 1 ppm, typical)

Amplitude

\>0.15 Vrms

Input Impedance

50 ohm

Output

Range (250 kHz to 1000 MHz)

+13 to -136 dBm

Range (>1000 MHz to 3000 MHz)

+10 to -136 dBm

Range (>3000 MHz to 4000 MHz)

+7 to -136 dBm

Resolution

0.02 dB

Level Accuracy, +7 to -127 dBm (250 kHz to 2 GHz)

±0.5 dB

Level Accuracy, +7 to -127 dBm (2 GHz to 4 GHz)

±0.9 dB

Level Accuracy, <-127 dBm (250 kHz to 2 GHz)

±1.5 dB

Level Accuracy, <-127 dBm (2 GHz to 4 GHz)

±2.5 dB

Attenuator Hold Level Range

\>17 dB

Switching Speed

<25 ms typical

Switching Speed (With Power Search Mode)

<210 ms typical

Reverse Power Protection (250 kHz to 2000 MHz)

50 Watts

Reverse Power Protection (>2000 MHz to 4000 MHz)

25 Watts

Max DC Voltage

50 V

SWR (250 kHz to 2000 MHz, typical)

<1.4:1

SWR (>2000 to 4000 MHz, typical)

<1.9:1

Output Impedance

50 ohms

Level Accuracy with Digital Modulation

pi/4 DQPSK or QPSK Formats

±0.15 dB

Constant Amplitude Formats (FSK, GMSK, etc.)

no degradation in power level accuracy

Level Accuracy with ALC Off

±0.5 dB, typical

Spectral Purity

SSB Phase Noise (20 kHz offset) at 500 MHz

<-120 dBc/Hz

SSB Phase Noise (20 kHz offset) at 1000 MHz

<-116 dBc/Hz

SSB Phase Noise (20 kHz offset) at 2000 MHz

<-110 dBc/Hz

SSB Phase Noise (20 kHz offset) at 3000 MHz

<-104 dBc/Hz

SSB Phase Noise (20 kHz offset) at 4000 MHz

<-104 dBc/Hz

Residual FM (Phase Noise Mode 1, CW, 0.3-3 kHz BW, CCITT, rms)

Residual FM (Phase Noise Mode 2)

Harmonics (<=+4 dBm output level)

<-30 dBc

Nonharmonics (250 kHz to 1000 MHz)

<-65 dBc

Nonharmonics (>1000 MHz to 2000 MHz)

<-59 dBc

Nonharmonics (>2000 MHz)

<-53 dBc

Subharmonics (<=1000 MHz)

None

Subharmonics (>1000 MHz)

<-40 dBc

IQ Modulation

I&Q Inputs Input Impedance

50 ohms

Full Scale Input

\[square root of (I2 + Q2)\] = 0.5 Vrms

External Input RF Bandwidth (1 dB)

20 MHz, typical

DC Offset (I + Q independently adjustable)

±100%

I/Q Gain Ratio

±4 dB

Static EVM (rms): <0.6 GHz

<0.75%

Static EVM (rms): 0.6 to 2 GHz

<0.5%

Static EVM (rms): 2 to 3.7 GHz

0.75%

Static EVM (rms): <=4 GHz

<1%

Magnitude Error (rms): <0.6 GHz

<0.5%

Magnitude Error (rms): 0.6 to 2 GHz

<0.35%

Magnitude Error (rms): 2 to 3.7 GHz

<0.5%

Magnitude Error (rms): <=4 GHz

<0.75%

Phase Error (rms): <0.6 GHz

<0.35°

Phase Error (rms): 0.6 to 2 GHz

<0.25°

Phase Error (rms): 2 to 3.7 GHz

<0.35°

Phase Error (rms): <=4 GHz

<0.5°

Origin Offset (dBc): <0.6 GHz

<-46

Origin Offset (dBc): 0.6 to 2 GHz

<-46

Origin Offset (dBc): 2 to 3.7 GHz

<-40

Origin Offset (dBc): <=4 GHz

<-40

Frequency Modulation

Maximum Deviation

N x 10 MHz

Resolution

0.1% of deviation or 1 Hz, whichever is greater

Deviation Accuracy (1 kHz rate, dev.

<±(3.5% of FM deviation + 20 Hz)

FM1 1 dB Bandwidth

dc/20 Hz to 100 kHz

FM1 3 dB Bandwidth, typical

dc/5 Hz to 10 MHz

FM2 1 dB Bandwidth

dc/20 Hz to 100 kHz

FM2 3 dB Bandwidth, typical

dc/5 Hz to 1 MHz

Distortion (1 kHz rate, THD, dev. = N x 100 kHz)

<1%

Phase Modulation

Maximum Deviation

N x 90 radians

Resolution

0.1% of set deviation

Deviation Accuracy (1 kHz rate)

<±(5% of deviation + 0.01 radians)

Normal BW (N x 90 rad): PM1 / PM2

dc to 100 kHz / dc to 100 kHz

High BW (N x 2pi rad): PM1 / PM2

dc to 1.5 MHz (typ) / dc to 1 MHz (typ)

High BW (N x pi/2 rad): PM1 / PM2

dc to 4 MHz (typ) / dc to 0.9 MHz (typ)

Distortion (1 kHz rate, THD, dev

<1%

Amplitude Modulation (fc>500 kHz)

Range (envelope peak <=max specified power)

0 to 100%

> **Important:** Reverse power protection: 50 W from 250 kHz to 2000 MHz and 25 W from >2000 MHz to 4000 MHz; maximum DC voltage 50 V.

> **Important:** This datasheet covers the E4430A (ESG-D1000A), specified at 250 kHz to 1000 MHz; however the Output, Frequency Bands, and Spectral Purity tables list values for ranges up to 4000 MHz that apply to higher-frequency members of the ESG-D series. Verify the installed frequency range on this specific unit's configuration.

## About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

-   ValueTronics warranty included with this pre-owned unit.
-   Functional verification included.
-   Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
-   Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 0.0 USD - 560.0 USD
- **Vendor:** Agilent
- **Type:** Rf Gen
- **Tags:** Agilent, Agilent Keysight, Manufacturers, product_manual_group_1, Product_used, RF, Signal Generators

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| None | 0.00 USD | In stock |
| NIST Traceable | 455.00 USD | In stock |
| NIST Traceable with Full Data | 490.00 USD | In stock |
| ISO IEC 17025 Accredited | 560.00 USD | In stock |

## Images

- Agilent E4430A Digital RF Signal Generator (Pre-Owned)

---

> Source: [ValueTronics](https://valuetronics.com/products/e4430a-agilent-rf-generator-used)
> Updated: 2026-07-06
