## Key Features At A Glance

-   CAT IV 600 V safety rating (IEC 61010) suited to industrial applications
-   6000-count backlit digital display, updating approximately 1.5 times per second
-   True RMS readings standard on the AC functions
-   1000 V DC and 750 V AC voltage ranges, plus 10 A AC/DC current ranges
-   Resistance to 60 MΩ, capacitance to 6 mF, and frequency to 60 MHz
-   Auto-ranging with manual range button, MIN MAX capture, and data hold
-   Continuity buzzer with optical and audio indication, plus diode/junction testing
-   GS38-compliant shrouded probe tips on silicon-cable test leads

A digital multimeter measures multiple electrical parameters from a single handheld instrument, letting a technician check voltage, current, resistance and related values across a circuit. The Megger AVO410 is a digital multimeter designed for the contracting electrician, with additional features that make the instrument suitable for a wide range of applications and users. It offers AC and DC voltage and current measurements as well as resistance, frequency and capacitance ranges.

The AVO410 carries a CAT IV 600 V safety rating, meaning the instrument is suitable for industrial applications. Its slim, compact case has a tough rubberised holster that provides an extra degree of protection from the extreme conditions found in industrial environments, and the positioning of the function switch and buttons lets the unit sit comfortably in the palm for single-handed use. The backlit display allows measurements to be made in poorly lit areas.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.

## Accessories Supplied

-   Test leads and probes

## Product Core & Specifications

Specification

Value

General

Display

6000 counts updates 1.5/sec.

Polarity

Automatic, positive implied, negative indicated

Over-range indication

OL or -OL

Battery indicator

Displayed when the battery voltage drops below operating voltage

Auto power down

Approx 10 minutes

Operating ambient

Non-condensing ≤10 °C; 11 °C ~ 30 °C (≤80% R.H); 31 °C ~ 40 °C (≤75% R.H); 41 °C ~ 50 °C (≤45% R.H)

Storage temperature range and humidity

\-20 °C to 60 °C, 0 to 80% R.H. when battery removed from meter

Temperature co-efficient

0.15 x (Spec.Acc'y) / °C, <18 °C or >28 °C

Safety

Complies with IEC61010 CAT IV 600 V

Power supply

Standard 9 V battery PP3, NEDA 1604, IEC6F22, JIS006P

Battery life

Alkaline 300 hours

Dimensions

76 mm x 158 mm x 38 mm without holster; 82 mm x 164 mm x 44 mm with holster

Weight

522 g

DC/AC Voltage

600.0 mV range

DC: ±(0.5% + 2 digits); AC: ±(0.9% + 5 digits) 50 Hz ~ 500 Hz (50 Hz/60 Hz sine wave only)

6.000 V range

DC: ±(0.5% + 2 digits); AC: ±(0.9% + 5 digits) 50 Hz ~ 500 Hz

60.00 V range

DC: ±(0.5% + 2 digits); AC: ±(0.9% + 5 digits) 50 Hz ~ 500 Hz

600 V range

DC: ±(0.5% + 2 digits); AC: ±(0.9% + 5 digits) 50 Hz ~ 500 Hz

DC 1000 V / AC 750 V range

DC: ±(0.5% + 2 digits); AC: ±(0.9% + 5 digits) 50 Hz ~ 500 Hz

AC accuracy note

Basic accuracy specified for a sine wave below 4000 counts. Over 4000 counts, add 0.6% to the accuracy. For non-sine waves below 2000 counts: ±1.5% addition error for C.F from 1.4 to 3

Protection

1000 V DC or AC

Input impedance

10 MΩ // less than 100 pF

CMRR (VAC)

\>60 dB at DC, 50 Hz/60 Hz

CMRR (VDC)

\>100 dB at DC, 50 Hz/60 Hz

NMRR

\>50 dB at DC, 50 Hz/60 Hz

AC conversion type

AC coupled, True RMS responding, calibrated to the sine wave input

Crest factor

C.F. = Peak/rms

DC/AC Current

600.0 μA range

DC: ±(1.0% + 2 digits); AC: N/A; Voltage burden <4 mV/μA

6000 μA range

DC: ±(1.0% + 2 digits); AC: N/A; Voltage burden <4 mV/μA

6.000 A range

DC: ±(1.0% + 2 digits); AC: ±(1.5% + 6 dgt) 50 Hz ~ 500 Hz; 2 V max

10.00 A range

DC: ±(1.0% + 2 digits); AC: ±(1.5% + 6 dgt) 50 Hz ~ 500 Hz; 2 V max

Overload protection (A input)

10 A (500 V) fast blow fuse

Overload protection (μA input)

600 V rms

Resistance

600.0 Ω

±(0.7% + 2 digits); Overload protection 600 V rms

6.000 KΩ

±(0.7% + 2 digits); Overload protection 600 V rms

60.00 KΩ

±(0.7% + 2 digits); Overload protection 600 V rms

600.0 KΩ

±(0.7% + 2 digits); Overload protection 600 V rms

6.000 MΩ

±(1.0% + 2 digits); Overload protection 600 V rms

60.00 MΩ

±(1.5% + 2 digits); Overload protection 600 V rms

Open circuit voltage

\-1.3 V approx.

Diode Check

Diode

Resolution 10 mV; Accuracy ±1.5% + digits (for 0.4 V ~ 0.8 V)

Max. test current

1.5 mA

Max. open circuit voltage

3 V

Overload protection

600 V rms

Continuity

Continuity

Built-in buzzer will sound when the resistance is less than 500 Ω approx. Response time is 100 ms approx.

Frequency

6000 Hz

Sensitivity 100 mV rms; Accuracy 0.1% ± 1 digit

60.00 KHz

Sensitivity 100 mV rms; Accuracy 0.1% ± 1 digit

600.0 KHz

Sensitivity 100 mV rms; Accuracy 0.1% ± 1 digit

6.000 MHz

Sensitivity 250 mV rms; Accuracy 0.1% ± 1 digit

60.0 MHz

Sensitivity 1 V rms; Accuracy 0.1% ± 1 digit

Overload protection

600 V rms

Sensitivity note

Less than 20 Hz, the sensitivity is 1.5 V rms; Max. sensitivity <5 V ac rms

Capacitance

6.000 nF

±(1.9% + 8 digits); Overload protection 600 V rms

60.00 nF

±(1.9% + 8 digits); Overload protection 600 V rms

600.0 nF

±(1.9% + 8 digits); Overload protection 600 V rms

6.000 μF

±(1.9% + 8 digits); Overload protection 600 V rms

60.00 μF

±(1.9% + 8 digits); Overload protection 600 V rms

600.0 μF

±(1.9% + 8 digits); Overload protection 600 V rms

6.00 mF

±(1.9% + 8 digits); Overload protection 600 V rms

> **Important:** The RS232 feature on the AVO410 has been disabled.

> **Important:** The DCµA input terminal is protected by 3.6 kΩ PTC (600 V rated) thermistors. The loading effect of these devices may cause measurement errors on low impedance circuits (<100 kΩ).

> **Important:** When measuring current on the A current terminal the instrument has an internal impedance of 0.01 Ω at AC/DC A in series with the circuit under test; the loading effect may cause measurement errors on low impedance circuits.

## About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 240.0 USD
- **Vendor:** Megger
- **Type:** Multi Met
- **Tags:** Manufacturers, Megger, Meters & DAQ, Multimeter, product_manual_group_1, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 240.00 USD | In stock |

## Images

- AVO410 Megger Digital Multimeter

---

> Source: [ValueTronics](https://valuetronics.com/products/avo410-megger-digital-multimeter-new)
> Updated: 2026-06-27