# B&K Precision HMR80360 80V/360A 10 kW Multi-Range DC Power Supply

# B&K Precision HMR80360 80V/360A 10 kW Multi-Range DC Power Supply

## Key Features At A Glance

-   Available in 10 kW and 18 kW models with output ranges from 80 V/360 A up to 1950 V/27 A
-   Multi-range (autoranging) operation delivers maximum power across multiple voltage/current combinations, replacing several fixed-range supplies
-   Compact 3U form factor with wide 200 to 415 VAC three-phase input simplifies rack integration
-   Master/Slave parallel operation supports up to 100 units connected in parallel for up to 1.8 MW
-   SiC MOSFET design delivers efficiency up to 95% with lower switching losses and improved thermal performance
-   Configurable internal resistance simulates the output characteristics of a battery for realistic DUT testing
-   LAN (LXI-compliant 1.4) and USB standard; optional user-installable GPIB and isolated analog interface modules
-   List mode programming with save/recall of up to 16 sequences with up to 500 steps each
-   Comprehensive OVP, OCP, OPP, OTP protection plus interlock and key-lock for power supply and DUT safety

The BK Precision HMR Series is a family of multi-range DC power supplies designed for automated test equipment (ATE) applications that require a wide span of output voltage and current in a compact 3U chassis. Five models are offered: the HMR80360 (80 V/360 A, 10 kW), HMR65046 (650 V/46 A, 10 kW), HMR130023 (1300 V/23 A, 10 kW), HMR500108 (500 V/108 A, 18 kW), and HMR195027 (1950 V/27 A, 18 kW). Each supply combines a large touchscreen display, dedicated rotary knobs for voltage and current, and a safeguarded output on/off button on the front panel, with rear-panel LAN, USB, master/slave communication ports, digital I/O, and remote sense terminals for system-level integration.

A DC power supply provides controlled, regulated voltage and current to a device under test, and is one of the most universally needed instruments across electronics design, production test, and qualification environments. The HMR Series is positioned specifically for ATE and integration use: it offers fast command response, list mode programming for test sequencing, LXI-compliant LAN for straightforward system development, and LabVIEW, IVI-C, and IVI.NET drivers for software control. Typical deployments described in the datasheet include rack-based test systems, battery-powered DUT testing using the configurable internal resistance feature, and high-power applications scaled through master/slave parallel operation up to 1.8 MW.

## Brand Heritage

B&K Precision Corporation has provided test and measurement instruments for more than 70 years, with headquarters in Yorba Linda, California. The B&K Precision group includes the French subsidiary Sefram in St. Etienne and B+K Precision Taiwan in Taipei, supported by independent service centers in Singapore and Brasil. B&K Precision operates an ISO 9001:2015 registered quality management system (certification body NSF-ISR, certificate number 6Z241-IS8).

## Compare Other Models in This Series

The HMR Series is offered in five models that share the same 3U chassis, the same touchscreen front panel, the same LAN/USB interfaces, and the same protection, list mode, and master/slave feature set. The models differ primarily in maximum output voltage, maximum output current, and maximum output power. Three models — HMR80360, HMR65046, and HMR130023 — are rated at 10 kW. Two models — HMR500108 and HMR195027 — are rated at 18 kW.

Across the family, multi-range operation means that each supply is not limited to a single maximum-power voltage/current point but instead delivers its full rated wattage across a continuous curve. The choice between models is therefore driven by the maximum voltage and maximum current required for the intended DUT, with the 18 kW pair offering both higher peak voltage (HMR195027) and higher peak current at moderate voltage (HMR500108) than the 10 kW models.

Each new model below is listed on its own dedicated product page with condition-matched pricing and the specifications shown in the comparison table that follows. Use the links to navigate to the individual model page for full ordering details and current availability.

The most useful way to read the comparison table is to start with the maximum output voltage and maximum output current columns, since these define which model fits a given DUT envelope. The HMR80360 is the low-voltage, high-current member of the family at 80 V and 360 A. The HMR65046 and HMR130023 step the voltage up to 650 V and 1300 V respectively while reducing current. The HMR500108 provides 500 V at 108 A within the 18 kW class, and the HMR195027 reaches the highest voltage in the family at 1950 V and 27 A.

Several secondary specifications scale with the output rating and are worth checking against the application. Programming and readback resolution differ by model — for example, 1 mV/10 mA on the HMR80360 versus 100 mV/1 mA on the HMR130023 and HMR195027. Ripple and noise, line regulation, load regulation, and temperature coefficient also vary across the family in proportion to the output range. The configurable internal resistance adjustment range scales from 0 to 0.2222 ohm on the HMR80360 up to 0 to 72.222 ohm on the HMR195027.

Model

Max Output Voltage

Max Output Current

Max Output Power

**HMR80360**

80 V

360 A

10 kW

HMR65046

650 V

46 A

10 kW

HMR130023

1300 V

23 A

10 kW

HMR500108

500 V

108 A

18 kW

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Accessories Supplied

-   Certificate of calibration
-   Output protection cover
-   AC input cover assembly
-   Ethernet cable

## Product Core & Specifications

Specification

HMR80360

Output Rating

Output Voltage

0 to 80 V

Output Current

0 to 360 A

Output Power

10 kW

Line Regulation

Voltage

16 mV

Current

180 mA

Load Regulation

Voltage

40 mV

Current

540 mA

Ripple and Noise (20 Hz to 20 MHz)

Voltage p-p

288 mV

Voltage rms

23 mV

Current rms

144 mA

Resolution

Programming

1 mV / 10 mA

Readback

1 mV / 10 mA

Programming Accuracy

Voltage

80 mV

Current

720 mA

Readback Accuracy

Voltage

80 mV

Current

720 mA

Output Response Time

Rise Time (Full Load)

< 30 ms

Fall Time (Full Load)

< 80 ms

Fall Time (No Load)

< 5 s

Protection

OVP Range

0 to 88 V

OCP Range

0 to 396 A

Internal Resistance

Adjustment Range

0 to 0.2222 Ω

Resolution

0.1 mΩ

Accuracy

< 2.3% of maximum settable resistance

General

Remote Sense Compensation

5 V

Transient Response Time

< 1.5 ms

Command Response Time

3 ms

Efficiency

93%

I/O Interfaces

LAN (LXI-compliant 1.4), USB

AC Line Input

Nominal

200 to 415 VAC, 50 Hz/60 Hz

Operating

180 to 460 VAC, 47 Hz to 63 Hz

AC Line Phase

3-phase

Maximum Rated Input Power

12 kVA

Input Current

40 A/phase

Inrush Current

66 A/phase

Power Factor (typical)

0.95 (200 - 415 V input)

Temperature Ratings

Operation

32 °F to 122 °F (0 °C to 50 °C)

Storage

\-4 °F to 158 °F (-20 °C to 70 °C)

Temperature Coefficient

Voltage

8 mV / °C

Current

36 mA / °C

Weight

80.1 lbs (36.3 kg)

Warranty

3 Years

Dimensions (W x H x D)

17.3" x 5.2" x 26" (440 x 132 x 660 mm)

**Important:** Maximum rated AC input power is 12 kVA for the 10 kW models and 21.6 kVA for the 18 kW models, drawn from a three-phase 200 to 415 VAC line (47 to 63 Hz operating range). Inrush current is rated at 66 A per phase for the 10 kW models and 99 A per phase for the 18 kW models.**Important:** All specifications apply to the unit after a temperature stabilization time of 30 minutes over an ambient temperature range of 23 °C ± 5 °C. Specifications are valid for single unit operation only. Under 80% humidity.**Important:** When working with motors, transformers, or other inductive loads, the optional protection unit (HMRPU180 or HMRPU540) safeguards the HMR Series power supply from reverse voltage and inductive kickback. Select the appropriate protection unit per model: HMRPU540 for HMR80360; HMRPU180 for HMR65046, HMR130023, HMR500108, and HMR195027.Recommended pairing: when driving motors, transformers, or other inductive loads, pair the HMR Series with the HMRPU180 protection unit (for HMR65046, HMR130023, HMR500108, and HMR195027) or the HMRPU540 (for HMR80360) to protect against reverse voltage and inductive kickback.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 13550.0 USD
- **Vendor:** B&K Precision
- **Type:** Dc Supply
- **Tags:** BK Precision, DC Power Supply, Manufacturers, Power Supplies & Loads, product_manual_group_3, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 13550.00 USD | In stock |

## Images

- B&K Precision HMR80360 80V/360A 10 kW Multi-Range DC Power Supply

---

> Source: [ValueTronics](https://valuetronics.com/products/hmr80360-new-bkprec-dc-supply-new)
> Updated: 2026-05-30