## Key Features at a Glance

-   2 fully isolated oscilloscope channels plus integrated digital multimeter
-   350 MHz analog bandwidth; software-upgradeable up to 500 MHz
-   5 GSa/s maximum real-time sampling; 10-bit ADC, up to 16-bit with high-resolution decimation
-   Rise time < 1 ns (calculated)
-   CAT IV 600 V / CAT III 1000 V safety rating across all inputs
-   7" WVGA 800 × 480 color touch display; IP51 ingress protection
-   8 additional digital logic channels (RTH-B1 mixed-signal); 1.25 GSa/s per logic channel; ±8 V threshold range
-   ~4 h battery operating time; includes RTH-K15 history and segmented memory option

## RTH1032 MSO — Field-Grade Handheld Oscilloscope

In summary, the Rohde & Schwarz RTH1032 MSO is a 2-channel (with integrated DMM) CAT IV 600 V / CAT III 1000 V rated handheld digital oscilloscope built on the R&S Scope Rider RTH platform. 2 analog + 8 digital logic + integrated dmm, with 350 MHz analog bandwidth, 5 GSa/s peak real-time sampling, a 10-bit ADC (up to 16-bit with high-resolution decimation), and calculated rise time of < 1 ns. The R&S RTH-K15 history and segmented memory option ships with the base unit, and the platform is software-upgradeable to higher bandwidth tiers via keycode without returning the instrument. The MSO configuration adds 8 digital logic channels (RTH-B1), sampled at 1.25 GSa/s each, with threshold groups configurable across CMOS 5.0/3.3/2.5 V, TTL, ECL, PECL, and LVPECL standards — making the instrument a single-handed mixed-signal debug tool for embedded systems, industrial control, and automotive ECU work in the field.

### What is the RTH1032 MSO used for?

The RTH1032 MSO is used for waveform debug and measurement on energized industrial and electrical equipment — motor drives, switching power supplies, photovoltaic inverters, distribution panels, automotive electronics, and field service of installed systems. Its fully isolated inputs and CAT IV 600 V / CAT III 1000 V rating allow direct connection to live AC mains and three-phase distribution circuits without an isolation transformer.

### Why does 350 MHz bandwidth matter for this application?

Oscilloscope bandwidth governs the highest signal frequency that can be measured with rated accuracy. The standard rule is to choose an instrument with 3 to 5 times the bandwidth of the highest signal frequency in the device under test. At 350 MHz, the RTH1032 MSO delivers a calculated rise time of < 1 ns, suitable for the digital edges, switching transients, and PWM waveforms encountered in modern industrial and power-electronics environments.

Quantitative anchors from the datasheet: peak real-time sampling of 5 GSa/s on a single active channel, DC gain accuracy ±1.5% of reading at input sensitivities above 5 mV/div, channel-to-channel isolation greater than 40 dB (measured) at matched input sensitivity, common-mode rejection greater than 100 dB at DC and AC ≤ 100 kHz (measured), timebase accuracy ±10 ppm, and waveform acquisition rate up to 50,000 waveforms/s. Input impedance is 1 MΩ ± 1% in parallel with 12 pF ± 2 pF (measured).

The RTH1032 MSO is built and certified to IEC/EN/DIN EN 61010-1, IEC/EN/DIN EN 61010-2-030, UL/CSA 61010-1, UL/CSA 61010-2-030, plus 61010-2-033 for the integrated DMM. EMC compliance follows CISPR 11 / EN 55011 Group 1 Class A and IEC/EN 61326-1. Environmental qualification covers MIL-PRF-28800F class 3 shock and vibration and IP51 ingress protection per IEC 60529. The instrument carries VDE, CCSAUS, and KC certifications.

### Where the RTH1032 MSO fits in a fleet

-   Field service technicians who need bench-grade scope performance at the point of measurement
-   Industrial maintenance, utility, and PV-installation crews working at CAT IV mains potential
-   Pairs with R&S RT-ZI10 / RT-ZI11 isolated probes to preserve full CAT IV / CAT III rating to the tip
-   Bandwidth upgrade keycodes (RTH-B221/B222/B223/B224 for 2-ch; RTH-B241/B242/B243/B244 for 4-ch) extend the platform without instrument replacement
-   Embedded and automotive bus debug with the included RTH-B1 logic channels (I²C, SPI, UART, CAN, CAN-FD, LIN, SENT decode optional)

## Accessories Supplied

Item

Description

Voltage probes

One 500 MHz, 10:1, 600 V CAT IV passive voltage probe per oscilloscope input channel

Meter test leads

One 600 V CAT IV test lead per meter input

Logic probe set

RTH-B1 mixed-signal probe set, 8 logic channels (D0–D7)

microSD card

Installed in the instrument; user data and settings storage

Battery pack

Lithium-ion smart battery, 72 Wh, 11.25 V

Power supply

External adapter with plugs for EU, CH, UK, US, CAN, China, Australia

RTH-K15 option

History and segmented memory option installed with the base unit

Compact manual

Printed quick-start reference

## Core Specifications

### Vertical System (Analog)

Input channels

2 analog + 8 digital logic + integrated DMM; all inputs floating and fully isolated

Input impedance

1 MΩ ± 1% || 12 pF ± 2 pF (meas.)

Analog bandwidth (−3 dB)

≥ 350 MHz

Lower frequency limit (AC)

< 8 Hz (meas.)

Rise time (calculated)

< 1 ns

ADC resolution

10 bit; up to 16 bit with high-resolution decimation

DC gain accuracy

±1.5% of reading (>5 mV/div); ±2% (>2 mV/div to 5 mV/div); ±2.5% (2 mV/div)

Input sensitivity

2 mV/div to 100 V/div in 1, 2, 4, 5 steps per decade

Max input voltage (BNC)

CAT IV 300 V (RMS), 424 V (peak); derates 20 dB/decade above 500 kHz

CMRR

\> 100 dB at DC and AC ≤ 100 kHz (meas.)

### Horizontal & Acquisition

Timebase range

1 ns/div to 500 s/div

Timebase accuracy

±10 ppm

Max real-time sampling

5 GSa/s (1 active channel); 2.5 GSa/s (2 active channels)

Max acquisition length

500 ksample (1 ch, sample mode); 250 ksample (2 ch, sample mode)

Acquisition modes

Sample, high resolution, peak detect, envelope, average (2 to 8192 waveforms)

Waveform acquisition rate

Max 50,000 waveforms/s

### Trigger System

Trigger sources

CH1, CH2 + D0–D7

Trigger modes

Auto, normal, single

Base trigger types

Edge, glitch, width, TV/video (PAL/NTSC/SECAM/PAL-M)

With RTH-K19

Pattern, state, runt, slew rate, window, data2clock, serial pattern, timeout, interval, SDTV/HDTV

Hold-off

8 ns to 10 s; 1 to 1,000,000,000 events

### Integrated Digital Multimeter

Inputs

4 mm banana, fully isolated from scope inputs, interfaces, and ground

Measurements

Voltage DC/AC/AC+DC, current (with clamp or shunt), resistance, continuity, diode, temperature (PT100/PT500), frequency, capacitance

Resolution

10,000 counts, 4 digits

Max input voltage

CAT III 1000 V (RMS), CAT IV 600 V (RMS); derates 20 dB/decade above 50 kHz

DC voltage accuracy

±(0.05% + 0.05% of range) on 1 V; ±(0.05% + 0.03% of range) on 10 V / 100 V; ±(0.08% + 0.03% of range) on 1000 V

CMRR / NMRR

\> 100 dB DC and 50/60 Hz; NMRR > 60 dB at 50/60 Hz (meas.)

### Digital / Logic Channels (RTH-B1 included)

Logic channels

8 (D0–D7)

Max input frequency

250 MHz (meas.)

Sampling rate (logic)

1.25 GSa/s per channel

Threshold range

±8 V in 25 mV steps; presets CMOS 5.0/3.3/2.5 V, TTL, ECL, PECL, LVPECL

Threshold accuracy

±(100 mV + 3% of setting) within ±4 V

Max input voltage (logic)

±40 V (peak)

Input impedance (logic)

100 kΩ ± 2% || ~4 pF at probe tip

### Display, Interfaces & Environmental

Display

7.0" LC TFT, 800 × 480 (WVGA)

Interfaces

USB host (Type A, 2.0); USB device (mini-B); LAN 10/100BASE-T (RJ-45); microSD slot

Battery / operating time

Lithium-ion smart battery, 72 Wh, 11.25 V; approx. 4 h operating; approx. 4 h charging (off)

Operating temperature

0 °C to +50 °C (battery); 0 °C to +40 °C (adapter)

IP rating

IP51 per IEC 60529

Shock / vibration

40 g per MIL-STD-810E method 516.4; MIL-PRF-28800F class 3

Dimensions (W × H × D)

201 × 293 × 74 mm (7.91 × 11.54 × 2.91 in)

Weight (with battery)

2.4 kg (5.3 lb) nom.

Calibration interval

1 year

## Available Software & Hardware Options

-   Bandwidth upgrades — RTH-B221/B222/B223/B224 (2-ch) or RTH-B241/B242/B243/B244 (4-ch) to 100/200/350/500 MHz
-   RTH-K1 — I²C / SPI serial triggering and decoding
-   RTH-K2 — UART / RS-232 / RS-422 / RS-485 serial triggering and decoding
-   RTH-K3 — CAN / LIN serial triggering and decoding
-   RTH-K9 — CAN-FD (requires RTH-K3)
-   RTH-K10 — SENT serial triggering and decoding
-   RTH-K15 — History and segmented memory (included with base unit)
-   RTH-K18 — Spectrum analysis
-   RTH-K19 — Advanced triggering
-   RTH-K33 — Frequency counter (2 counters)
-   RTH-K34 — Harmonic analysis (up to 64 harmonics, 10 Hz to 1 MHz fundamental)
-   RTH-K38 — User scripting (HTML / JavaScript)
-   RTH-K200 / K200US — Wireless LAN 802.11 b/g/n
-   RTH-K201 — Web interface remote control

**Important note on probes.** Maximum input voltage at the BNC inputs derates above 500 kHz per the published input rating curve. To preserve full CAT IV 600 V / CAT III 1000 V isolation to the probe tip, use R&S RT-ZI10 or RT-ZI11 isolated probes. Standard 600 V CAT IV passive probes ship with the base unit, and the RTH-B1 logic probe set is included in MSO configurations.

**Note on calibration.** Manufacturer-recommended calibration interval is 1 year. Optional accredited calibration coverage is available via R&S extended-warranty programs (CW1/CW2, AW1/AW2) — contact your Test Architect for details.

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

## Details

- **Price:** 10515.0 USD
- **Vendor:** Rohde & Schwarz
- **Type:** Ms Oscilloscope
- **Tags:** Buy New Equipment AVADA, Handheld, Manufacturers, Mixed Signal, Mixed Signal Oscilloscope, New, Oscillioscope, Oscilloscope, Oscilloscopes, Product new, product_manual_group_3, Product_new, Rohde, Rohde & Schwarz

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 10515.00 USD | In stock |

## Images

- RTH1032MSO Rohde & Schwarz NEW

---

> Source: [ValueTronics](https://valuetronics.com/products/rth1032mso-new-rohdes-unassigned-new)
> Updated: 2026-05-21