# FPL1007-P6 Rohde & Schwarz NEW

## R&S®FPL1007 Spectrum Analyzer — 7.5 GHz

-   **Frequency range:** 5 kHz to 7.5 GHz
-   **Reference-class phase noise:** < –99 dBc/Hz at 1 kHz offset and < –130 dBc/Hz at 1 MHz offset (1 GHz carrier)
-   **DANL down to –152 dBm typ.** (1 Hz RBW, preamp off, 5 MHz to 3 GHz) for low-level signal capture
-   **Signal analysis bandwidth:** 12.8 MHz standard, extendable to 40 MHz with the R&S®FPL1-B40 option
-   **10.1-inch (21 cm) WXGA touchscreen** (1280 × 800) with multi-tile measurement view
-   **Direct-conversion front end** optimized for the AC-coupled 5 kHz to 7.5 GHz region with low-noise performance
-   **Optional internal tracking generator** (R&S®FPL1-B9) covering 5 kHz to 7.5 GHz with 115 dB dynamic range
-   **Portable form factor:** 6 kg (13.22 lb) without options; optional internal lithium-ion battery (R&S®FPL1-B31) for true field operation

In summary, the Rohde & Schwarz R&S®FPL1007 is a portable RF spectrum analyzer covering 5 kHz to 7.5 GHz, built around the FPL platform's reference-class phase noise specification and an optional 40 MHz analysis bandwidth. It is designed for engineers who need premium German-engineered measurement accuracy in a chassis compact enough for bench, rack, and field operation. It is the volume FPL configuration for general RF R&D and IoT/Wi-Fi product test labs because 7.5 GHz captures both the fundamentals and second harmonics of every sub-6 GHz wireless standard.

### What is the R&S®FPL1007 used for?

The R&S®FPL1007 is used for sub-6 GHz 5G NR characterization through the n78 band, Wi-Fi 6E coverage in the 6 GHz band including its second-harmonic content, the entire ISM band stack, lower satellite C-band uplink/downlink at 4–6 GHz, microwave-link characterization, and full EMI pre-compliance scanning to FCC Part 15 and CISPR 22/32 limits with second-harmonic verification. The instrument supports general-purpose swept spectrum analysis, FFT analysis, channel power and ACLR measurements, occupied bandwidth, spurious emissions, harmonic and intermodulation measurements, and — with the appropriate firmware options — phase noise, noise figure, vector signal analysis, and EMI pre-compliance.

### How does the R&S®FPL1007 compare to other RF analyzers in its class?

Within the R&S®FPL family the FPL1007 occupies the 7.5 GHz coverage tier. Across the industry it competes most directly with mid-tier portable and compact-bench analyzers in the same frequency band, but it carries the Rohde & Schwarz phase noise pedigree (often cited as the published reference for SSB phase noise comparisons) and the same software application ecosystem used by the higher-end R&S®FSVA, R&S®FSV3000, and R&S®FSW series. This means an engineer can develop a measurement workflow on the FPL and lift it onto a flagship analyzer without rewriting test code.

### Factual grounding and measurement performance

The FPL1007 specifies SSB phase noise of < –99 dBc/Hz at 1 kHz offset, < –110 dBc/Hz at 100 kHz offset, and < –130 dBc/Hz at 1 MHz offset (1 GHz carrier). Displayed Average Noise Level (DANL) is < –149 dBm (5 MHz to 3 GHz), < –140 dBm (5 GHz to 7.5 GHz), normalized to 1 Hz RBW with the sample detector and preamplifier off at +20 °C to +30 °C. Third-order intercept (TOI) is > +17 dBm in the 300 MHz to 3 GHz band with the preamplifier off. Total measurement uncertainty is 0.5 dB in the 1 MHz to 3 GHz region (signal level 0 dB to –50 dB below reference level, S/N > 20 dB, sweep type FFT, span/RBW < 100, +20 °C to +30 °C, 95 % confidence level). Recommended calibration interval is 1 year.

### Industry alignment and standards conformity

The FPL1007 supports measurement workflows aligned with CISPR 11, CISPR 16-1-1, IEC/EN 61326-1 and 61326-2-1, IEC/EN 61000-3-2 and 61000-3-3, FCC Part 15 (with the R&S®FPL1-K54 EMI application), 3GPP-defined modulation schemes (with the R&S®FPL1-K70 vector signal analysis option), and ISO/IEC 17025 traceable calibration practices when paired with an accredited calibration laboratory. The instrument carries CE, CCSAUS, and KCC test marks and meets EN 60068-2-6, EN 60068-2-64, and MIL-PRF-28800F mechanical resistance requirements.

### How the R&S®FPL1007 earns its place on the bench

-   **Phase noise reference:** The R&S phase noise specification (< –130 dBc/Hz at 1 MHz offset, 1 GHz carrier) makes this instrument suitable for measuring close-in phase noise on oscillators, synthesizers, and PLLs — the measurement that drives recommendation toward R&S in demanding RF labs.
-   **Portability without performance loss:** At 6 kg (13.22 lb) without options, the FPL1007 is small enough to move between labs and field locations while retaining the same touchscreen interface and software ecosystem as the larger R&S benchtop analyzers.
-   **Single-chassis upgrade path:** Most options (RF preamplifier, 40 MHz bandwidth, GPIB, DC power, OCXO, second SSD, EMI application) are user- or service-retrofittable, allowing labs to begin with a base unit and grow capability with the project.
-   **Touchscreen and multi-tile UI:** The 10.1-inch WXGA touchscreen runs the same R&S analyzer firmware paradigm as the FSVA/FSV3000/FSW, including multi-tile measurement layouts, MultiView, and SCPI compatibility for migration of automated test sequences.

### Accessories Supplied

-   R&S®FPL1007 spectrum analyzer base unit
-   Power cable
-   Quick start guide

### Product Core — The R&S®FPL1007 in Detail

A spectrum analyzer translates signal energy into a frequency-domain view: power on the vertical axis, frequency on the horizontal axis. Where an oscilloscope shows voltage versus time, a spectrum analyzer shows where energy lives across the radio-frequency landscape. The R&S®FPL1007 performs this translation across 5 kHz to 7.5 GHz, using a swept and FFT hybrid architecture that automatically switches to FFT sweep mode at resolution bandwidths of 50 kHz or below — a key contributor to the instrument's fast sweep time and accurate narrowband measurement performance.

The FPL1007 uses a direct-conversion front end across its full frequency range, optimized for fast sweep performance and low noise without the insertion loss of a preselector. This makes the instrument particularly well suited to wide-instantaneous-bandwidth measurements when combined with the R&S®FPL1-B40 40 MHz analysis bandwidth option.

#### Frequency

**Frequency range**

5 kHz to 7.5 GHz

**Frequency resolution**

0.01 Hz

**Internal reference aging (standard)**

1 × 10⁻⁶ per year

**Internal reference aging (with R&S®FPL1-B4 OCXO)**

1 × 10⁻⁷ per year

**Temperature drift (standard, 0 °C to +50 °C)**

1 × 10⁻⁶

**Temperature drift (with OCXO)**

1 × 10⁻⁷

**Marker resolution**

0.01 Hz

**Frequency counter resolution**

0.001 Hz

**Display range for frequency axis**

0 Hz, 10 Hz to maximum frequency

**Number of sweep points (default / range)**

1001 / 101 to 100001 (up to 200001 with K54 EMI active)

#### Phase Noise — 1 GHz Carrier

Carrier Offset

SSB Phase Noise

100 Hz

–88 dBc/Hz (nom.)

1 kHz

< –99 dBc/Hz

10 kHz

< –105 dBc/Hz, –108 dBc/Hz (typ.)

100 kHz

< –110 dBc/Hz, –115 dBc/Hz (typ.)

1 MHz

< –130 dBc/Hz, –135 dBc/Hz (typ.)

10 MHz

–152 dBc/Hz (nom.)

#### Sweep Time

**Range, span = 0 Hz**

1 µs to 8000 s

**Range, span ≥ 10 Hz, RBW ≥ 100 kHz**

1 ms to 8000 s

**Range, span ≥ 10 Hz, RBW < 100 kHz**

75 µs to 8000 s (FFT)

**Sweep time accuracy, span = 0 Hz**

0.1 % (nom.)

**Sweep time accuracy, span ≥ 10 Hz, RBW ≥ 100 kHz**

3 % (nom.)

#### Resolution Bandwidths

**Sweep filter RBW (–3 dB)**

100 kHz to 10 MHz, in 1/2/3/5 sequence

**FFT filter RBW (–3 dB)**

1 Hz to 50 kHz, in 1/2/3/5 sequence

**Bandwidth uncertainty**

< 3 % (nom.)

**Shape factor 60 dB:3 dB**

< 5 (nom.)

**Channel filters (–3 dB)**

100/200/300/500 Hz; 1/1.5/2/2.4/2.7/3/3.4/4/4.5/5/6/7.5/8.5/9/10/12.5/14/15/16/20/21/25/30/50/100/150/192/200/300/500 kHz; 1/1.228/1.5/2/3/3.75/5/10 MHz

**EMI filters (–6 dB, with R&S®FPL1-K54)**

10/100/200 Hz; 1/9/10/100/120 kHz; 1 MHz

**Video bandwidths**

1 Hz to 10 MHz, in 1/2/3/5 sequence

#### Signal Analysis Bandwidth

**Standard analysis bandwidth (nom.)**

12.8 MHz

**With R&S®FPL1-B40 option (nom.)**

40 MHz

#### Level Measurement

**Display range**

Displayed noise floor up to +30 dBm

**Maximum DC voltage**

50 V

**Maximum CW RF power (RF preamp off, 0 dB att.)**

+20 dBm (0.1 W)

**Maximum CW RF power (≥ 10 dB att.)**

+30 dBm (1 W)

**Maximum pulse voltage (≥ 10 dB att., preamp off)**

150 V

**Maximum pulse energy (≥ 10 dB att., 10 µs)**

1 mWs

**Reference level setting range**

–130 dBm to (–13 dBm + RF attenuation − preamp gain), in 0.01 dB steps

**Logarithmic level axis**

1 dB to 200 dB, in 1 dB steps

**Number of traces**

6

**Trace detectors**

Max peak, min peak, auto peak (normal), sample, RMS, average

**EMI detectors (with K54)**

Quasi-peak, RMS-average, CISPR-average

**Absolute level uncertainty at 50 MHz (+20 °C to +30 °C)**

< 0.3 dB (σ = 0.1 dB)

**Absolute level uncertainty at 50 MHz (0 °C to +50 °C)**

< 0.5 dB (σ = 0.17 dB)

**Attenuator switching uncertainty (50 MHz, 0 to 45 dB)**

< 0.2 dB (σ = 0.07 dB)

#### Frequency Response (RF Att. 10/20/30/40 dB, Preamp Off, +20 °C to +30 °C)

Frequency Range

Response

5 kHz ≤ f < 3 MHz

< 1 dB (nom.)

3 MHz ≤ f < 3 GHz

< 0.3 dB (σ = 0.1 dB)

3 GHz ≤ f < 7.5 GHz

< 0.6 dB (σ = 0.2 dB)

#### Intermodulation, Sensitivity and Spurious Response

**1 dB compression of input mixer (two tone, RF att. 0 dB, preamp off)**

+7 dBm (nom.)

**TOI, 10 MHz ≤ fin < 300 MHz**

\> +13 dBm, +16 dBm (typ.)

**TOI, 300 MHz ≤ fin < 3 GHz**

\> +17 dBm, +20 dBm (typ.)

**TOI, 3 GHz ≤ fin < 6 GHz**

\> +15 dBm, +18 dBm (typ.)

**SHI, 1 MHz < fin < 900 MHz**

+45 dBm (nom.)

**SHI, 900 MHz ≤ fin ≤ 13.25 GHz**

+70 dBm (nom.)

#### Displayed Average Noise Level (DANL, RF Preamp Off, 1 Hz RBW Normalized)

Frequency Range

DANL

5 kHz ≤ f < 100 kHz

–143 dBm (typ.)

100 kHz ≤ f < 5 MHz

< –140 dBm, –143 dBm (typ.)

5 MHz ≤ f < 3 GHz

< –149 dBm, –152 dBm (typ.)

3 GHz ≤ f < 5 GHz

< –143 dBm, –146 dBm (typ.)

5 GHz ≤ f ≤ 7.5 GHz

< –140 dBm, –143 dBm (typ.)

#### Measurement Speed

**Local measurement and display update rate (1001 sweep points, sweep optimization: speed)**

1 ms (1000/s) (nom.)

**Maximum sweep rate, remote, trace average on**

0.9 ms (1100/s) (nom.)

**Remote measurement and LAN transfer**

3.2 ms (357/s) (nom.)

**Marker peak search**

1.9 ms (nom.)

**Center frequency tune + sweep + sweep data transfer**

16 ms (nom.)

#### Trigger Functions

**Trigger source**

Free run, video, external, IF power, I/Q power

**Trigger offset, span ≥ 10 Hz**

0 s to 20 s

**Trigger offset, span = 0 Hz**

(−sweep time) to 20 s

**Maximum deviation of trigger offset**

± 10 ns

**IF power trigger sensitivity (min / max)**

–60 dBm / –15 dBm (+ RF att. − preamp gain)

**IF power trigger bandwidth (RBW > 5 MHz / ≤ 5 MHz)**

40 MHz / 6 MHz (nom.)

**Gate sources**

Video, external, IF power, I/Q power

**Gate delay / length**

0 s to 20 s / 10 ns to 20 s, min. resolution 10 ns

#### I/Q Data

**Interface**

GPIB or LAN

**Memory length**

25 Msample I and Q (max.)

**Word length of I/Q samples**

14 bit

**Sampling rate (standard)**

100 Hz to 16 MHz

**Sampling rate (with R&S®FPL1-B40)**

100 Hz to 100 MHz

#### Inputs and Outputs

**RF input impedance**

50 Ω

**RF input connector**

type N female

**Setting range of attenuator (standard)**

0 dB to 45 dB, in 5 dB steps

**Setting range of attenuator (with R&S®FPL1-B25)**

0 dB to 45 dB, in 1 dB steps

**RF preamplifier gain (with R&S®FPL1-B22)**

20 dB (nom.)

**USB front / rear**

2 × Type A (USB 2.0) / 2 × Type A (USB 3.1)

**Reference output**

BNC female, 50 Ω, 10 MHz, > 0 dBm (nom.)

**Reference input**

BNC female, 50 Ω, 10 MHz ± 5 ppm, > 0 dBm

**External trigger/gate input**

BNC female, 0.5 V to 3.5 V, 10 kΩ

**LAN interface**

10/100/1000BASE-T, RJ-45

**External monitor**

DisplayPort Rev. 1.3 (SN ≥ 300000); DVI-D on earlier serial numbers

#### General Data

**Display**

21 cm (10.1") LC TFT color, 1280 × 800 pixel (WXGA)

**Pixel failure rate**

< 1 × 10⁻⁵

**Internal storage (standard)**

128 GB SSD (32 GB on SN < 300000)

**External storage**

USB 2.0/3.1 memory devices

**Operating temperature range**

0 °C to +50 °C

**Storage temperature range**

–20 °C to +70 °C

**Damp heat**

+40 °C at 85 % rel. humidity, EN 60068-2-30

**Vibration (sinusoidal)**

5 Hz to 55 Hz / 55 Hz to 150 Hz, EN 60068-2-6

**Vibration (random)**

5 Hz to 500 Hz, 1.2 g RMS, EN 60068-2-64, MIL-PRF-28800F

**Shock**

40 g shock spectrum, MIL-STD-810E, method 516.4, procedure I; MIL-PRF-28800F

**EMC**

EMC Directive 2014/30/EU; IEC/EN 61326-1, 61326-2-1; CISPR 11/EN 55011; IEC/EN 61000-3-2, 61000-3-3

**AC supply**

100 V to 240 V ± 10 %, 50 Hz to 60 Hz ± 5 %

**Safety**

EN 61010-1, IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1

**Test marks**

CE, CCSAUS, KCC

**Power consumption (operating, nom.)**

65 W

**Power consumption (max., with all options)**

115 W

**Power consumption (standby, no B4)**

5 W (nom.)

**Dimensions (W × H × D)**

408 mm × 186 mm × 235 mm (16.06 in × 7.32 in × 9.25 in)

**Net weight (without options)**

6 kg (13.22 lb)

**Net weight (with internal battery)**

7.3 kg (16 lb)

**Recommended calibration interval**

1 year

#### Available Options & Upgrades

Option

Description

Order No.

R&S®FPL1-B4

OCXO reference frequency

1323.1902.02

R&S®FPL1-B5

Additional interfaces (user port, noise source ctrl, IF/Video, audio)

1323.1883.02

R&S®FPL1-B9

Internal tracking generator (5 kHz to 7.5 GHz)

1323.1925.07

R&S®FPL1-B10

GPIB interface

1323.1890.02

R&S®FPL1-B12

External generator control

1353.6660.02

R&S®FPL1-B19

Second solid-state drive (SSD)

1304.0427.02 / 1304.0427.03

R&S®FPL1-B22

3 GHz/7.5 GHz preamplifier option (R&S®FPL1-B22)

1323.1719.02

R&S®FPL1-B25

1 dB steps for electronic attenuator

1323.1990.02

R&S®FPL1-B30

DC power supply 12 V/24 V

1323.1877.02

R&S®FPL1-B31

Internal lithium-ion battery (2 packs + internal charger)

1323.1725.02

R&S®FPL1-B40

40 MHz analysis bandwidth

1323.1931.02

R&S®FPL1-K7

AM/FM/PM measurement demodulator

1323.1731.02

R&S®FPL1-K9

Power sensor measurement (R&S®NRPxx)

1323.1754.02

R&S®FPL1-K30

Noise figure and gain measurements (requires B5)

1323.1760.02

R&S®FPL1-K33

Security write protection for SSD

1323.1290.02

R&S®FPL1-K40

Phase noise measurement application

1323.1831.02

R&S®FPL1-K41R

40 MHz real-time spectrum measurements

1353.6702.02

R&S®FPL1-K54

EMI measurement application (CISPR detectors)

1323.1783.02

R&S®FPL1-K70

Vector signal analysis

1323.1748.02

R&S®FPL1-K70M

Multi-modulation analysis (requires K70)

1323.1625.02

R&S®FPL1-K70P

BER measurements with PRBS data (requires K70)

1323.1631.02

### Optional Internal Tracking Generator (R&S®FPL1-B9)

With the R&S®FPL1-B9 option, the FPL1007 adds an internal CW signal source useful for stimulus-response measurements such as filter response, amplifier gain flatness, return loss (with appropriate directional bridge), and scalar network analysis.

**Frequency range**

5 kHz to 7.5 GHz

**Setting resolution (independent CW source)**

0.01 Hz

**SSB phase noise (1 GHz, 10 kHz offset)**

< –102 dBc/Hz, –108 dBc/Hz (typ.)

**SSB phase noise (1 GHz, 100 kHz offset)**

< –105 dBc/Hz, –111 dBc/Hz (typ.)

**SSB phase noise (1 GHz, 1 MHz offset)**

< –117 dBc/Hz, –130 dBc/Hz (typ.)

**Specified level range**

–50 dBm to 0 dBm

**Setting range**

–60 dBm to +10 dBm

**Setting resolution**

0.1 dB

**Absolute level uncertainty (50 MHz, –10 dBm)**

< 0.5 dB

**Dynamic range (RBW = 1 kHz, f = 1 GHz)**

115 dB (nom.)

**GEN output connector**

Type N female, 50 Ω

**GEN output VSWR**

1.5 (nom.)

**Reverse power, DC voltage**

50 V

**Reverse power, CW RF**

+30 dBm (1 W)

#### Recommended Extras

-   **R&S®FPL1-Z1:** Protective hard cover (1323.1960.02)
-   **R&S®FPL1-Z2:** Soft carrying bag for transport and outdoor operation (1323.1977.02)
-   **R&S®FPL1-Z3:** H-style shoulder harness, requires Z2 (1323.1683.02)
-   **R&S®FPL1-Z4:** Spare lithium-ion battery pack (1323.1677.02)
-   **R&S®FSV-B34:** Lithium-ion battery charger for charging spare batteries (1321.3950.02)
-   **R&S®FPL1-Z6:** 19" rackmount kit, RAL 5014 (1323.1954.02)
-   **R&S®FPL1-Z6B:** 19" rackmount kit, RAL 5000 (1323.1954.03)

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturers Data Sheet to verify published specifications. Feedback on this webpage is always welcome, please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

## Details

- **Price:** 36935.0 USD
- **Vendor:** Rohde & Schwarz
- **Type:** Spec An
- **Tags:** Analyzer, Analyzers, Buy New Equipment AVADA, Manufacturers, New, Other, Other Equipment, Product new, product_manual_group_3, Product_new, Rohde, Rohde & Schwarz, spec ana, Spectrum, spectrum analyzers

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 36935.00 USD | In stock |

## Images

- FPL1007-P6 Rohde & Schwarz NEW

---

> Source: [ValueTronics](https://valuetronics.com/products/fpl1007-p6-new-rohdes-unassigned-new)
> Updated: 2026-05-21
