# Keysight E4980B Precision LCR Meter, 20 Hz to 2 MHz

# Keysight E4980B Precision LCR Meter, 20 Hz to 2 MHz

## Key Features At A Glance

-   Test frequency from 20 Hz to a model-dependent maximum of 300 kHz, 500 kHz, 1 MHz, or 2 MHz across the series
-   Four-terminal-pair measurement of L, C, R, Z, D, Q, G, B, Y and phase in series or parallel equivalent-circuit models
-   Basic measurement accuracy to 0.05% (varies with measurement-time mode, frequency, and signal level per accuracy tables)
-   GPIB (IEEE-488), USB (USBTMC/USB488, USB 2.0), and 10/100BaseT LAN interfaces standard; LXI Class C compliant
-   OPEN, SHORT, and LOAD compensation with auto/manual impedance ranging and up to 256-measurement averaging
-   List sweep up to 201 points plus comparator bin sort (9 BINs) for component sorting
-   Optional Power and DC Bias enhancement (Option 001) adds up to 15 Vrms signal, variable DC bias, and Vdc-Idc measurement
-   Optional handler (Option 201) and scanner (Option 301) interfaces, up to two interface slots on the rear panel

The E4980B and E4980BL are precision LCR meters that measure the impedance characteristics of passive components and materials using a four-terminal-pair configuration. The E4980B covers a test frequency range of 20 Hz to 2 MHz. The E4980BL provides the same core measurement architecture with an upper frequency limit set by its installed frequency option: 20 Hz to 300 kHz (option -032), 20 Hz to 500 kHz (option -052), or 20 Hz to 1 MHz (option -102).

An LCR meter applies a known test signal to a device under test and derives the component's inductance, capacitance, resistance, and related parameters from the resulting voltage and current. This series measures a broad parameter set, including Cp/Cs, Lp/Ls, D, Q, G, Rp, Rs, R-X, Z-phase, G-B, and Y-phase, with both parallel and series equivalent-circuit models selectable. A deviation measurement function can output the deviation from a reference value or the percentage of deviation from that reference.

We hold our inventory in our own 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, which lets us control quality and fulfillment directly rather than relaying orders to a third party.

## Brand Heritage

These instruments are manufactured by Keysight Technologies. Keysight's test and measurement heritage traces back to Hewlett-Packard, whose measurement business was spun off as Agilent Technologies in 1999; Agilent's electronic measurement division then became Keysight Technologies in 2014.

## Compare Other Models in This Series

The E4980B/E4980BL series is a family of precision LCR meters built on a common four-terminal-pair measurement architecture and parameter set, differentiated primarily by test frequency coverage. The E4980B is the 20 Hz to 2 MHz model. The E4980BL is offered with frequency options that set its upper limit to 300 kHz, 500 kHz, or 1 MHz.

Across the family, the measurement functions, compensation modes, list sweep, comparator, and interface options are shared, so the choice between models is driven by the highest test frequency an application requires and by which options (such as the Power and DC Bias enhancement) are installed.

Each new model below links to its own dedicated product page with condition-matched pricing. Select the model and frequency configuration that fits your application, then review that page for its specific new availability and configuration.

The E4980B is the top-frequency member of the series, providing test frequencies up to 2 MHz with frequency resolution down to 1 kHz in the 1 MHz to 2 MHz segment and as fine as 0.01 Hz at the low end of its range.

The defining difference among these models is the upper test frequency limit: 2 MHz for the E4980B, versus 1 MHz, 500 kHz, or 300 kHz for the E4980BL depending on its installed frequency option (-102, -052, or -032). The comparison table that follows lists each model's frequency coverage alongside the shared measurement and interface specifications.

Configuration options also distinguish individual units. The Power and DC Bias enhancement (Option 001) is installable on the E4980B but is shown as not installable on the E4980BL, while the handler (Option 201) and scanner (Option 301) interfaces are installable on both. Refer to each model's row in the table to confirm which capabilities apply to that configuration.

Model

Frequency Range

Basic Accuracy

Max Test Signal Level

**E4980B**

20 Hz to 2 MHz

0.05%

2.0 Vrms (15 Vrms with Option 001)

E4980BL-102

20 Hz to 1 MHz

0.05%

2.0 Vrms

E4980BL-052

20 Hz to 500 kHz

0.05%

2.0 Vrms

E4980BL-032

20 Hz to 300 kHz

0.05%

2.0 Vrms

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

## Product Core & Specifications

Specification

Value

Measurement Functions

Measurement parameters

Cp-D, Cp-Q, Cp-G, Cp-Rp, Cs-D, Cs-Q, Cs-Rs, Lp-D, Lp-Q, Lp-G, Lp-Rp, Lp-Rdc, Ls-D, Ls-Q, Ls-Rs, Ls-Rdc, R-X, Z-θ, G-B, Y-θ, Vdc-Idc (Vdc-Idc requires Option 001)

Equivalent circuits for measurement

Parallel, Series

Impedance range selection

Auto (auto range mode), Manual (hold range mode)

Trigger mode

Internal (INT), Manual (MAN), External (EXT), GPIB (BUS)

Trigger delay time

0 s to 999 s

Step delay time

0 s to 999 s

Measurement terminal

Four-terminal pair

Test cable length

0 m, 1 m, 2 m, 4 m

Measurement time modes

Short mode, Medium mode, Long mode

Averaging

1 to 256 measurements (resolution 1)

Test Signal

Test frequency range

20 Hz to 2 MHz (E4980B); 20 Hz to 1 MHz (E4980BL-102); 20 Hz to 500 kHz (E4980BL-052); 20 Hz to 300 kHz (E4980BL-032)

Test frequency resolution

0.01 Hz (20 Hz - 99.99 Hz), 0.1 Hz (100 Hz - 999.9 Hz), 1 Hz (1 kHz - 9.999 kHz), 10 Hz (10 kHz - 99.99 kHz), 100 Hz (100 kHz - 999.9 kHz), 1 kHz (1 MHz - 2 MHz)

Test frequency accuracy

± 0.01%

Test signal modes

Normal, Constant

Test signal voltage range

0 Vrms to 2.0 Vrms

Test signal voltage resolution

200 µVrms / 500 µVrms / 1 mVrms (by range)

Test signal voltage accuracy (Normal)

± (10% + 1 mVrms)

Test signal current range

0 Arms to 20 mArms

Test signal current resolution

2 µArms / 5 µArms / 10 µArms (by range)

Test signal voltage monitor accuracy (Vac)

± (3% of reading value + 0.5 mVrms), 5 mVrms - 2 Vrms; ± (6% of reading value + 1 mVrms) for > 1 MHz

Test signal current monitor accuracy (Iac)

± (3% of reading value + 5 µArms), 50 µArms - 20 mArms; ± (6% of reading value + 10 µArms) for > 1 MHz

Basic Accuracy

Basic accuracy Ab (MED, LONG)

0.05%

Basic accuracy Ab (SHORT)

0.10%

Calibration accuracy Acal (|Z|)

0.03% to 0.1% (frequency dependent)

DC Bias Signal (Standard)

DC bias voltage range

0 V to +2 V (0 V / 1.5 V / 2 V only)

DC bias voltage accuracy

0.1% + 2 mV (23 °C ± 5 °C); (0.1% + 2 mV) × 4 (0 to 18 °C or 28 to 55 °C)

DC bias test signal current (1.5 V/2.0 V)

Output current: Max. 20 mA

Power and DC Bias Enhancement (Option 001)

Test signal voltage range

0 Vrms to 15 Vrms

Test signal voltage setup accuracy (Normal)

± (10% + 1 mVrms)

Test signal current range

0 Arms to 100 mArms

DC bias voltage range

\-40 V to +40 V

DC bias voltage accuracy

0.1% + 2 mV (23 °C ± 5 °C); (0.1% + 2 mV) × 4 (0 to 18 °C or 28 to 55 °C)

DC bias current range

\-100 mA to 100 mA

DC source signal voltage range

\-10 V to 10 V (resolution 1 mV)

DC source signal voltage accuracy

0.1% + 3 mV (23 °C ± 5 °C); (0.1% + 3 mV) × 4 (0 to 18 °C or 28 to 55 °C)

DC source signal current range

\-45 mA to 45 mA (nominal)

Compensation

Compensation functions

OPEN compensation, SHORT compensation, LOAD compensation

List Sweep / Comparator

List sweep points

Maximum of 201 points

Bin sort

Primary parameter into 9 BINs, OUT\_OF\_BINS, AUX\_BIN, LOW\_C\_REJECT; secondary parameter into HIGH, IN, LOW

BIN count

0 to 999999

Measurement Assistance

Data buffer function

Up to 201 measurement results read out in a batch

Save/Recall

Up to 10 setup conditions to built-in non-volatile memory; up to 10 setup conditions to USB memory

I/O Interfaces

GPIB

24-pin D-Sub (Type D-24), female; complies with IEEE488.1, 2 and SCPI

USB host port

Type-A, female (for connection to USB memory only)

USB interface port

Type mini-B; complies with USBTMC-USB488 and USB 2.0; female

LAN

10/100 BaseT Ethernet, 8 pins

LXI Compliance

Class C (only applies to units with firmware revision A.02.00 or later)

General

Power source voltage range

90 to 264 VAC

Rated frequency

50 / 60 Hz

Power consumption

Max. 150 VA

Operating temperature

0 to 55 °C (no condensation)

Storage temperature

\-20 to 70 °C (no condensation)

Outer dimensions

375 (width) × 105 (height) × 390 (depth) mm (nominal)

Weight

4.9 kg (without Front, Rear Bumper, and Handle); 5.8 kg (with Front, Rear Bumper, and Handle)

Display

LCD, 320 × 240 (pixels), RGB color

Maximum discharge withstand voltage

1000 V (C < 2 µF)

Safety

IEC/EN 61010-1; INSTALLATION CATEGORY II, POLLUTION DEGREE 2, MEASUREMENT CATEGORY NONE; CSA C22.2 No. 61010-1; UL std no. 61010-1

EMC

IEC 61326-1; CISPR 11 Group 1, Class A; AS/NZS CISPR 11

> **Important:** Maximum discharge withstand voltage: 1000 V (for capacitors under 2 uF). Discharge capacitors before connecting them to the UNKNOWN terminal or a test fixture to avoid damage to the instrument.

> **Important:** Option 001 (Power and DC Bias enhancement) is installable on the E4980B only; it is not installable on the E4980BL.

> **Important:** The Vdc-Idc measurement function is available only when Option 001 is installed.

> Recommended pairing: the 16048A/D/E test leads named in the relative-accuracy conditions supply the 0 m, 1 m, 2 m, and 4 m four-terminal-pair cable lengths the specifications are based on.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

**Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.**

## Details

- **Price:** 29751.0 USD
- **Vendor:** Keysight Technologies
- **Type:** Lcr Met
- **Tags:** Agilent, E4980, E4980B, Factory New, Inc., Keysight, Keysight Technologies, Lcr Meter, Manufacturers, Model 4980, Product_new

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 29751.00 USD | In stock |

## Images

- E4980B Keysight Technologies LCR Meter

---

> Source: [ValueTronics](https://valuetronics.com/products/e4980b-keysight-lcr-meter-new)
> Updated: 2026-06-02