# SDS5104X Siglent Digital Oscilloscope New

**SDS5104X** — SDS5000X Series · Super Phosphor Oscilloscope — 350 MHz–1 GHz, 5 GSa/s

## Key Features At A Glance

-   4 analog channels, 1 GHz bandwidth
-   Sample rate 5 GSa/s
-   8-bit ADC vertical resolution
-   Record length 250 Mpts/ch, 500 Mpts total
-   Capture rate up to 110,000 wfm/s normal, 500,000 wfm/s Sequence
-   16 digital channels with 1.25 GSa/s sample rate
-   Built-in 25 MHz function/AWG
-   10.1" multi-touch display (1024×600); VGA + LAN web control
-   USB host, USB-TMC, LAN, Pass/Fail, Trigger Out, 10 MHz In/Out

## Overview

The Siglent SDS5104X is a 1 GHz, 4-channel digital oscilloscope from the SDS5000X Series — part of Siglent's Super Phosphor Oscilloscope family. In summary, this is a 8-bit-resolution, 5 GSa/s-sample-rate instrument intended for general benchtop signal capture, mixed-signal debug, serial-bus decoding, and power-supply characterization.

### What is the SDS5104X used for?

The SDS5104X is used to capture, view, measure, and analyze electrical waveforms up to 1 GHz. Typical applications: embedded system debug, power-rail characterization, motor and inverter waveform inspection, audio and sensor signal analysis, education, and serial-bus decoding for the protocols listed below.

### What can it trigger on and decode?

Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay, Video (HDTV), Trigger Zone. Serial: I2C, SPI, UART, CAN, LIN, CAN FD, CAN XL, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester, SpaceWire, ARINC429.

### Factual grounding — measurement and analysis

Data analysis functions include: Search, Navigate, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis. Acquisition and measurement: Sequence up to 100,000 segments; History up to 100,000 frames; 60+ auto measurements with histogram, trend, gating, and Math/History/Ref; 2 Mpts FFT plus formula editor. The SDS5104X delivers 5 GSa/s real-time sampling and 250 Mpts/ch, 500 Mpts total of record length — sufficient to capture long-duration events while preserving timebase resolution for zoom inspection.

### Industry positioning

The SDS5000X (8-bit) sits below the SDS5000X HD as the cost-optimized 1 GHz workhorse: same UI, same trigger and decode breadth, deeper memory than the SDS3000X HD, but without the 12-bit acquisition path. The right call when bandwidth and memory drive the decision and 8-bit dynamic range is sufficient.

## Accessories Supplied

-   Oscilloscope main unit
-   AC power cord (region-appropriate)
-   Passive probes (one per analog channel; bandwidth-matched to the unit)
-   USB cable (USB-TMC compliant)
-   Quick Start guide / Programming guide reference card
-   Certificate of calibration

## Product Core & Specifications

The SDS5104X acquisition and analysis specifications are listed below. Where the SDS5000X Series family shares architecture across its members, model-specific differences are concentrated in bandwidth, channel count, and (for HD-series) ADC vertical resolution.

### Acquisition

Specification

Value

Analog Channels

4

Bandwidth

1 GHz

Max Sample Rate

5 GSa/s

Vertical Resolution (ADC)

8-bit

Record Length

250 Mpts/ch, 500 Mpts total

### Trigger and Serial Decode

Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay, Video (HDTV), Trigger Zone. Serial: I2C, SPI, UART, CAN, LIN, CAN FD, CAN XL, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester, SpaceWire, ARINC429.

### Math, Measurement, and Analysis

Sequence up to 100,000 segments; History up to 100,000 frames; 60+ auto measurements with histogram, trend, gating, and Math/History/Ref; 2 Mpts FFT plus formula editor.

Data analysis: Search, Navigate, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis.

## Unit Options

Unit Options below are multi-select — choose any combination that applies. Some options are software-licensed; others require additional hardware (e.g., logic probe). Contact your Test Architect to confirm bundle pricing.

-   16 digital channels — included standard, 1.25 GSa/s, 62.5 Mpts (logic probe required)
-   Built-in 25 MHz function / arbitrary waveform generator (built-in)
-   Power Analysis software option
-   Bode Plot (frequency-response measurement)

## Calibration (Factory New)

All Factory New Siglent oscilloscopes ship with a factory calibration and certificate as standard. Optional upgrade calibration paths (NIST Traceable, NIST Traceable with Full Data, ISO/IEC 17025 Accredited) can be added at the time of order — please specify your required calibration tier on the order, and ValueTronics will route the unit through the appropriate calibration lab prior to shipment.

This webpage was written by a human with an A.I. 'Intern', which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

## Details

- **Price:** 8683.0 USD
- **Vendor:** Siglent
- **Type:** Dig Oscilloscope
- **Tags:** Authorized New Line, Digital, Factory New, NDAA-Non-Compliant, Oscilloscopes, Product new, product_manual_group_3, SDS5104X, Siglent, Siglent SDS5000X Series, Super Phosphor SPO, Updated Item Review, Value Tier

## Variants

| Variant | Price | Available |
|---------|-------|-----------|
| Default Title | 8683.00 USD | In stock |

## Images

- SDS5104X Siglent Digital Oscilloscope New

---

> Source: [ValueTronics](https://valuetronics.com/products/sds5104x-siglent-digital-oscilloscope-new)
> Updated: 2026-05-21